My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2727 N Main Place Dr #MTR01 - Plan
PBA
>
Building
>
ProjectDox
>
M
>
Main Place Dr
>
2727 N Main Place Dr Unit# MTR01
>
2727 N Main Place Dr #MTR01 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:06:22 PM
Creation date
6/1/2025 12:06:17 PM
Metadata
Fields
Template:
Plan
Permit Number
20182155
Full Address
2727 N Main Place Dr Unit# MTR01
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CONTRACTOR <br />SHEET DESCRIPTION: <br />PLACARD <br />DRAWN DATE 10.01.2025 <br />DRAWN BY EMMANUEL <br />REVIEWED BY DESIGN TEAM <br />REVISIONS <br />REV DESCRIPTION DATE <br />SHEET INDEX <br />UTILITY : SCE <br />PROJECT INFORMATION <br />AHJ : SANTA ANA <br />ADDRESS : 2727 N MAINPLACE DR, <br />SANTA ANA, CA 92705 <br />NAME : PALOMA AT MAIN PLACE <br />APN : 002-221-52,002-221-46 <br />SYSTEM INFORMATION: <br />(75)LITEON <br />CHARGING STATIONS <br />PROJECT INFORMATION: <br />CHARGIE TO DESIGN AND <br />INSTALL THE CHARGING <br />SYSTEM. <br />Δ AHJ CORRECTIONS 04.08.24A <br />Δ Site Plan details update 05.28.24B <br />ΔC AHJ CORRECTIONS 07.22.24 <br />ΔD AHJ CORRECTIONS 10.09.24 <br />ΔE AHJ CORRECTIONS 10.22.24 <br />ΔF AHJ CORRECTIONS 11.22.24 <br />Δ AHJ CORRECTIONS 01.10.25G <br />WARNING PLACARDS: <br />DEDICATED TO EV ONLY <br />OTHER LOADS MUST <br />NOT BE CONNECTED <br />LABEL LOCATION: <br />TO BE PLACED IN DEDICATED EV SUB PANEL <br />& NEXT TO THE EV BREAKER IN THE <br />DISTRIBUTION PANEL <br />SIZE: 4" X 2" QTY:1 <br />LABEL LOCATION: <br />TO BE PLACED IN DEDICATED EV SUB PANEL <br />& NEXT TO THE EV BREAKER IN THE <br />DISTRIBUTION PANEL <br />SIZE: 4" X 2" QTY:1 <br />SIGNAGE REQUIREMENTS AND NOTES: <br />1. ACCESSIBLE SIGNAGE IS NOT REQUIRED WHERE A TOTAL OF FOUR OF FEWER EV SPACES ARE PROVIDED. <br />2. FIVE TO TWENTY-FIVE TOTAL EV SPACES ARE PROVIDED: <br />A - ONE VAN ACCESSIBLE EV SPACE SHALL BE IDENTIFIED BY ISA SIGNAGE <br />B - ACCESSIBLE SIGNAGE IS NOT REQUIRED AT THE STANDARD ACCESSIBLE EV SPACES <br />3. TWENTY-SIX OR MORE EV SPACES ARE PROVIDED <br />4. ALL REQUIRED VAN ACCESSIBLE AND STANDARD ACCESSIBLE EV SPACES SHALL BE IDENTIFIED BY ISA <br />SIGNAGE <br />5. IDENTIFICATION SIGNS SHALL BE REFLECTORIZED WITH MINIMUM AREA OF 70 SQUARE INCHES. (11B-812.8.7) <br />6. THE IDENTIFICATION SIGN SHALL BE VISIBLE FROM THE EV SPACE IT SERVES <br />7. SIGNS IDENTIFYING VAN ACCESSIBLE EV SPACES SHALL CONTAIN THE WORDS "VAN ACCESSIBLE" <br />8. IDENTIFICATION SIGNS SHALL BE PERMANENTLY POSTED EITHER IMMEDIATELY ADJACENT TO THE VEHICLE <br />SPACE OF WITHIN THE PROJECTED VEHICLE SPACE WIDTH AT THE FRONT END OF VEHICLE SPACE. <br />(11B-812.8.7) <br />9. MOUNTING HEIGHT OF IDENTIFICATION SIGNS SHALL BE: <br />A - 60 INCHES MINIMUM ABOVE THE FINISH FLOOR OF GROUND SURFACE MEASURED TO THE BOTTOM OF <br />THE SIGN, ORB - 80 INCHES MINIMUM ABOVE THE FINISH FLOOR OR GROUND SURFACE MEASURED TO THE <br />BOTTOM OF THE SIGN, WHEN THE SIGN PROJECTS OVER THE ACCESS AISLE OR OTHER CIRCULATION PATH. <br />GV1 <br />LABEL LOCATION: <br />TO BE PLACED ON THE CIRCUITS ON MSP - EV <br />SIZE: 1'6" X 1" QTY:1 <br />CAUTION <br />EXISTING SERVICE PANELS LOCATION IS <br />SHOWN <br />2727 N MAINPLACE DRIVE, <br />SANTA ANA, CA 92705 <br />SERVICE 1 <br />SERVICE 2GV2 <br />LABEL LOCATION: <br />TO BE PLACED ON THE CIRCUITS ON MSP - EV <br />SIZE: 1'6" X 1" QTY:1 <br />GV3 <br />LABEL LOCATION: <br />TO BE PLACED ON THE CIRCUITS ON MSP - EV <br />SIZE: 1'6" X 1" QTY:1 <br />G3V1 <br />LABEL LOCATION: <br />TO BE PLACED ON THE CIRCUITS ON MSP - EV <br />SIZE: 1'6" X 1" QTY:1 <br />GV4 <br />LABEL LOCATION: <br />TO BE PLACED ON THE CIRCUITS ON MSP - EV <br />SIZE: 1'6" X 1" QTY:1 <br />PROJECT INFORMATION: <br />CHARGIE WILL DESIGN AND INSTALL THE ENTIRE EV CHARGING SYSTEM. <br />GV5 <br />LABEL LOCATION: <br />TO BE PLACED ON THE CIRCUITS ON MSP - EV <br />SIZE: 1'6" X 1" QTY:1 <br />00-EV-14 <br />LABEL LOCATION: <br />TO BE PLACED IN DEDICATED EV SUB PANEL <br />& NEXT TO THE EV BREAKER IN THE <br />DISTRIBUTION PANEL <br />SIZE: 4" X 2" QTY:1 <br />LABEL LOCATION: <br />TO BE PLACED IN DEDICATED EV SUB PANEL <br />& NEXT TO THE EV BREAKER IN THE <br />DISTRIBUTION PANEL <br />SIZE: 4" X 2" QTY:1 <br />LABEL LOCATION: <br />TO BE PLACED IN DEDICATED EV SUB PANEL <br />& NEXT TO THE EV BREAKER IN THE <br />DISTRIBUTION PANEL <br />SIZE: 4" X 2" QTY:1 <br />G5V1 <br />LABEL LOCATION: <br />TO BE PLACED ON THE CIRCUITS ON MSP - EV <br />SIZE: 1'6" X 1" QTY:1 <br />2727 N Mainplace Dr, <br />Santa Ana, CA 92705 <br />208Y/120V 2000A 3Ø 4W <br />2727 N Mainplace Dr, <br />Santa Ana, CA 92705 <br />208Y/120V 600A 3Ø 4W <br />2727 N Mainplace Dr, <br />Santa Ana, CA 92705 <br />208Y/120V 400A 3Ø 4W <br />2727 N Mainplace Dr, <br />Santa Ana, CA 92705 <br />208Y/120V 225A 3Ø 4W <br />2727 N Main Place Dr <br />#MTR011/28/2025
The URL can be used to link to this page
Your browser does not support the video tag.