CCOPYRIGHT
<br />It is the clients responsibility prior to or during construction to notify the architect in writing
<br />of any perceived errors or omissions in the plans and specifications of which a contractor
<br />thoroughly knowledgeable with the building codes and methods of construction should
<br />reasonably be aware. Written instructions addressing such perceived errors or omissions
<br />shall be received from the architect prior to the client or clients subcontractors proceeding
<br />with the work. The client will be responsible for any defects in construction if these
<br />procedures are not followed.
<br />Zohrabians Art of Design
<br />700 Palm Drive, Suite 106
<br />Glendale, CA 91202
<br />zartofdesign.com
<br />818.300.9420
<br />2n
<br />d
<br />
<br />P
<br />l
<br />a
<br />n
<br />
<br />C
<br />h
<br />e
<br />c
<br />k
<br />
<br />S
<br />u
<br />b
<br />m
<br />i
<br />t
<br />t
<br />a
<br />l
<br />No.Date Description
<br />06/05/2024 100% DD SET
<br />06/14/2024 50% CD PROGRESS SET
<br />06/21/2024 75% CD PROGRESS SET
<br />07/02/2024 NEIGHBORHOOD REVIEW
<br />07/10/2024 1ST PLAN CHECK SUBMITTAL
<br />09/13/2024 2ND PLAN CHECK SUBMITTAL
<br />82
<br />9
<br />
<br />N
<br />.
<br />
<br />G
<br />A
<br />R
<br />F
<br />I
<br />E
<br />L
<br />D
<br />
<br />S
<br />T
<br />R
<br />E
<br />E
<br />T
<br />SA
<br />N
<br />T
<br />A
<br />
<br />A
<br />N
<br />A
<br />,
<br />
<br />C
<br />A
<br />
<br />9
<br />2
<br />7
<br />0
<br />1
<br />Santa Ana, CA 92701
<br />829 N. Garfield Street
<br />Name:
<br />Project Contact:
<br />Phone:
<br />Email:
<br />
<br />Principal:
<br />Z.AOD Project No:2024-02
<br />Arthur Zohrabians
<br />818.300.9420
<br />Arthur Zohrabians
<br />info@zartofdesign.com
<br />Phone No.:949.922.7075
<br />Email:vanitapuri@gmail.com
<br />Owner
<br />GA
<br />R
<br />F
<br />I
<br />E
<br />L
<br />D
<br />
<br />R
<br />E
<br />S
<br />T
<br />O
<br />R
<br />A
<br />T
<br />I
<br />O
<br />N
<br />
<br />/
<br />
<br />R
<br />E
<br />M
<br />O
<br />D
<br />E
<br />L
<br />Address:
<br />Ren.11/30/25
<br />A
<br />No. C37490
<br />A
<br />A FOILOFC
<br />R
<br />INTA
<br />S
<br />ET
<br />TC
<br />A RCHITE
<br />DESNECIL
<br />RTHUR
<br />HAMAYAK ZOHRABI
<br />A
<br />SN
<br />VVS Estates, LLC
<br />1
<br />Vanita Soni PuriAttn:
<br />FIRE-RESISTANCE
<br />RATED PENETRATION
<br />DETAILS
<br />A903
<br />STEEL DUCT
<br />02_H_BB_ULFC7060_STEEL DUCT 6" OR SMALLER SCALE: 1 1/2" = 1'-0"
<br />FIRE RESISTANCE LISTING:
<br />U.L. DESIGN NO.
<br />F-C-7060
<br />FIRE RATING:
<br />1 HR
<br />1.FLOOR - CEILING ASSEMBLY - THE 1 HR FIRE-RATED WOOD JOIST FLOOR-CEILING ASSEMBLY SHALL BE CONSTRUCTED OF
<br />THE MATERIALS AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL L500 DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY,
<br />AS SUMMARIZED BELOW:
<br />A.FLOORING SYSTEM - LUMBER OR PLYWOOD SUBFLOOR WITH FINISH FLOOR OF LUMBER, PLYWOOD OR FLOOR TOPPING
<br />MIXTURE* AS SPECIFIED IN THE INDIVIDUAL FLOOR-CEILING DESIGN.
<br />B.WOOD JOISTS - NOM 10 IN. (254 MM) DEEP (OR DEEPER) LUMBER, STEEL OR COMBINATION LUMBER AND STEEL JOISTS,
<br />TRUSSES OR STRUCTURAL WOOD MEMBERS* WITH BRIDGING AS REQUIRED AND WITH ENDS FIRESTOPPED.
<br />C.GYPSUM BOARD* - THICKNESS, TYPE, NUMBER OF LAYERS AND FASTENERS AS REQUIRED IN THE INDIVIDUAL
<br />FLOOR-CEILING DESIGN. DIAM OF OPENING IS TO BE MAX 1-1/2 IN. (38 MM) LARGER THAN DIAM OF STEEL DUCT.
<br />1A. CHASE WALL - (OPTIONAL, NOT SHOWN) - THE THROUGH PENETRANT (ITEM 2) MAY BE ROUTED THROUGH A 1 HR FIRE RATED
<br />SINGLE, DOUBLE OR STAGGERED WOOD STUD/GYPSUM BOARD CHASE WALL. DEPTH OF CHASE WALL STUD CAVITY TO BE
<br />MIN 1/2 IN. (13 MM) GREATER THAN DIAMETER OF OPENING CUT IN TOP PLATES TO ACCOMMODATE THE THROUGH
<br />PENETRANT (ITEM 2). THE CHASE WALL SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER SPECIFIED IN THE
<br />INDIVIDUAL U300 SERIES WALL AND PARTITION DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE
<br />FOLLOWING CONSTRUCTION FEATURES:
<br />A.STUDS - NOM 2 BY 4 IN. (51 BY 102 MM), 2 BY 6 IN. (51 BY 152 MM) OR DOUBLE NOM 2 BY 4 IN. (51 BY 102 MM) LUMBER STUDS.
<br />B.SOLE PLATE - NOM 2 BY 4 IN. (51 BY 102 MM), 2 BY 6 IN. (51 BY 152 MM)OR PARALLEL 2 BY 4 IN. (51 BY 102 MM) LUMBER
<br />PLATES, TIGHTLY BUTTED.
<br />C.TOP PLATE - THE DOUBLE TOP PLATE SHALL CONSIST OF TWO NOM 2 BY 4 IN (51 BY 102 MM)., TWO NOM 2 BY 6 IN. (51 BY
<br />152 MM) OR TWO SETS OF PARALLEL 2 BY 4 IN. (51 BY 102 MM) LUMBER PLATES, TIGHTLY BUTTED. DIAM OF OPENING IS TO
<br />BE MAX 1-1/2 IN. (38 MM) LARGER THAN DIAM OF STEEL DUCT. AS AN ALTERNATE, THE OPENING MAY BE SQUARE-CUT WITH
<br />A MAX DIMENSION 1-1/2 IN. (38 MM) GREATER THAN THE DIAM OF THE PIPE. PLATES MAY BE DISCONTINUOUS OVER
<br />OPENING, TERMINATING AT TWO OPPOSING EDGES OF OPENING. MAX LENGTH OF DISCONTINUITY IS 7-1/2 IN. (191 MM).
<br />D.STEEL PLATE - WHEN LUMBER PLATES ARE DISCONTINUOUS, NOM 1-1/2 IN. (38 MM) WIDE NO. 20 GAUGE (OR HEAVIER)
<br />GALV STEEL PLATES SHALL BE INSTALLED TO CONNECT DISCONTINUOUS LUMBER PLATES AND TO PROVIDE A FORM FOR
<br />THE FILL MATERIAL. STEEL PLATES SIZED TO LAP 2 IN. (51 MM) ONTO EACH DISCONTINUOUS LUMBER PLATE AND SECURED
<br />TO LUMBER PLATES WITH STEEL SCREWS OR NAILS.
<br />E.GYPSUM BOARD* - THICKNESS, TYPE, NUMBER OF LAYERS AND FASTENERS SHALL BE AS SPECIFIED IN THE INDIVIDUAL
<br />WALL AND PARTITION DESIGN.
<br />2.STEEL DUCT - ONE NOM 6 IN. (152 MM) DIAM (OR SMALLER) NO. 30 GA (OR HEAVIER) GALVANIZED STEEL DUCT TO BE
<br />INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE OPENING. ANNULAR SPACE TO BE MIN 0 IN. (POINT
<br />CONTACT) TO MAX 1-1/2 IN. (38 MM). STEEL DUCT TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF FLOOR-CEILING ASSEMBLY.
<br />3.FILL, VOID OR CAVITY MATERIAL* - SEALANT - MIN 5/8 IN. (16 MM) THICKNESS OF FILL MATERIAL APPLIED WITHIN THE
<br />ANNULUS, FLUSH WITH BOTTOM SURFACE OF CEILING OR TOP PLATE. MIN 1/4 IN. (6 MM) DIAM BEAD OF FILL MATERIAL
<br />APPLIED AT POINT CONTACT LOCATION AT THE PENETRANT/CEILING OR CHASE WALL TOP PLATE INTERFACE.
<br />SPECIFIED TECHNOLOGIES INC - SPECSEAL LCI SEALANT, SPECSEAL LC150 SEALANT OR TYPE WF300 CAULK
<br />*INDICATES SUCH PRODUCTS SHALL BEAR THE UL OR CUL CERTIFICATION MARK FOR JURISDICTIONS EMPLOYING THE UL
<br />OR CUL CERTIFICATION (SUCH AS CANADA), RESPECTIVELY.
<br />System No. F-C-7060
<br />ANSI/UL1479 (ASTM E814)
<br />F Rating - 1 Hr
<br />T Ratings - 1 Hr
<br />L Rating At Ambient - Less Than 1 CFM/sq ft
<br />CAN/ULC S115
<br />F Rating - 1 Hr
<br />FT Ratings - 1 Hr
<br />FH Rating - 1 Hr
<br />FTH Ratings - 1 Hr
<br />L Rating At Ambient - Less Than 1 CFM/sq ft
<br />1B
<br />3
<br />1A
<br />1C
<br />2
<br />SYSTEM NO. W-L-2241
<br />F RATINGS - 1 AND 2 HR (SEE ITEM 1)
<br />T RATINGS - 0, 1/4, 1 AND 1-3/4 HR (SEE ITEM 2)
<br />L RATING AT AMBIENT - LESS THAN 1 CFM/SQ FT
<br />L RATING AT 400 F - LESS THAN 1 CFM/SQ FT
<br />1.WALL ASSEMBLY - THE 1 OR 2 HR FIRE-RATED GYPSUM BOARD/STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE
<br />MATERIALS AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL U300 OR U400 SERIES WALL OR PARTITION DESIGN IN THE UL FIRE
<br />RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES:
<br />A.STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF
<br />NOM 2 BY 4 IN. (51 BY 102 MM) LUMBER SPACED MAX 16 IN. (406 MM) OC. STEEL STUDS TO BE MIN 3-1/2 IN. (89 MM) WIDE AND
<br />SPACED MAX 24 IN. (610 MM) OC.
<br />B.GYPSUM BOARD* - THICKNESS, TYPE, NUMBER OF LAYERS AND FASTENERS AS SPECIFIED IN THE INDIVIDUAL WALL AND
<br />PARTITION DESIGN. DIAM OF OPENING TO BE 1 IN. TO 1-1/8 IN. (25 TO 29 MM) LARGER THAN OUTSIDE DIAM OF PIPE.
<br />THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS EQUAL TO THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN
<br />WHICH IT IS INSTALLED. WHEN ITEM 2G OR 2H IS USED, THE HOURLY F RATING IS 1 HR.
<br />2.THROUGH PENETRANT - ONE NONMETALLIC PIPE, CONDUIT OR TUBE TO BE INSTALLED ECCENTRICALLY OR CONCENTRICALLY
<br />WITHIN THE FIRESTOP SYSTEM. PIPE, CONDUIT OR TUBE TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF THE WALL ASSEMBLY.
<br />THE FOLLOWING TYPES AND SIZES OF NONMETALLIC PIPES, CONDUITS AND TUBES MAY BE USED:
<br />A.POLYVINYL CHLORIDE (PVC) PIPE - NOM 2 IN. (51 MM) DIAM (OR SMALLER) SCHEDULE 40 SOLID OR CELLULAR CORE PVC PIPE
<br />FOR USE IN CLOSED (PROCESS OR SUPPLY) OR VENTED (DRAIN, WASTE OR VENT) PIPING SYSTEMS. ANNULAR SPACE SHALL
<br />BE MIN 0 IN. ( 0 MM, POINT CONTACT) TO MAX 1 IN. (25 MM).
<br />B.CHLORINATED POLYVINYL CHLORIDE (CPVC) PIPE - NOM 2 IN. (51 MM) DIAM (OR SMALLER) SDR 13.5 OR SCHEDULE 80 CPVC
<br />PIPE FOR USE IN CLOSED (PROCESS OR SUPPLY) PIPING SYSTEMS. ANNULAR SPACE SHALL BE MIN 0 IN. ( 0 MM, POINT
<br />CONTACT) TO MAX 1 IN. (25 MM).
<br />C.RIGID NONMETALLIC CONDUIT+ - NOM 2 IN. (51 MM) DIAM (OR SMALLER) SCHEDULE 40 PVC CONDUIT INSTALLED IN
<br />ACCORDANCE WITH ARTICLE 347 OF THE NATIONAL ELECTRICAL CODE (NFPA 70). ANNULAR SPACE SHALL BE MIN 0 IN. ( 0 MM,
<br />POINT CONTACT) TO MAX 1 IN. (25 MM).
<br />D.ELECTRICAL NONMETALLIC TUBING+ - NOM 2 IN. (51 MM) DIAM (OR SMALLER) PVC TUBING INSTALLED IN ACCORDANCE WITH
<br />ARTICLE 331 OF THE NATIONAL ELECTRICAL CODE (NFPA 70). ANNULAR SPACE SHALL BE MIN 0 IN. ( 0 MM, POINT CONTACT) TO
<br />MAX 1 IN. (25 MM).
<br />E.CROSS LINKED POLYETHYLENE (PEX) TUBING - NOM 1 IN. (25 MM) DIAM (OR SMALLER) SDR9 PEX TUBING FOR USE IN CLOSED
<br />(PROCESS OR SUPPLY) PIPING SYSTEMS. ANNULAR SPACE SHALL BE MIN 0 IN. ( 0 MM, POINT CONTACT) TO MAX 1 IN. (25 MM).
<br />F.ACRYLONITRILE BUTADIENE STYRENE (ABS) PIPE - NOM 1-1/2 IN. (38 MM) DIAM (OR SMALLER) SCHEDULE 40 SOLID-CORE OR
<br />CELLULAR CORE ABS PIPE FOR USE IN CLOSED (PROCESS OR SUPPLY) OR VENTED (DRAIN, WASTE OR VENT) PIPING
<br />SYSTEMS. ANNULAR SPACE SHALL BE MIN 1/4 IN. (6 MM) TO MAX 3/4 IN. (19 MM).
<br />G.POLYVINYL CHLORIDE (PVC) PIPE - NOM 3 IN. (76 MM) DIAM (OR SMALLER) SCHEDULE 40 SOLID OR CELLULAR CORE PVC PIPE
<br />FOR USE IN CLOSED (PROCESS OR SUPPLY) PIPING SYSTEMS. ANNULAR SPACE SHALL BE MIN 0 IN. (0 MM, POINT CONTACT)
<br />TO MAX 1 IN. (25 MM).
<br />H.CHLORINATED POLYVINYL CHLORIDE (CPVC) PIPE - NOM 3 IN. (76 MM) DIAM (OR SMALLER) SDR 17 CPVC PIPE FOR USE IN
<br />CLOSED (PROCESS OR SUPPLY) PIPING SYSTEMS. ANNULAR SPACE SHALL BE MIN 0 IN. (0 MM, POINT CONTACT) TO MAX 1 IN.
<br />(25 MM).
<br />WHEN ITEM 2A OR 2B IS USED, THE T RATING IS 1/4 HR. WHEN ITEM 2C, 2D, OR 2E IS USED, THE T RATING IS 1 HR AND 1-3/4 HR
<br />FOR 1 HR AND 2 HR FIRE RATED WALLS, RESPECTIVELY. WHEN ITEM 2F, 2G, OR 2H IS USED, T RATING IS 0 HR.
<br />3.FILL, VOID OR CAVITY MATERIAL* - SEALANT - MIN 5/8 IN. (16 MM) THICKNESS OF FILL MATERIAL APPLIED WITHIN ANNULUS,
<br />FLUSH WITH BOTH SURFACES OF WALL ASSEMBLY. AT POINT CONTACT LOCATION, MIN 1/4 IN. (6 MM) DIAM BEAD OF FILL
<br />MATERIAL APPLIED AT NONMETALLIC PIPE/GYPSUM BOARD INTERFACE ON BOTH SURFACES OF WALL.
<br />SPECIFIED TECHNOLOGIES INC - SPECSEAL LCI SEALANT OR TYPE WF300 FIRESTOP CAULK (FOR WOOD STUDS ONLY)
<br />*INDICATES SUCH PRODUCTS SHALL BEAR THE UL OR CUL CERTIFICATION MARK FOR JURISDICTIONS EMPLOYING THE UL OR
<br />CUL CERTIFICATION (SUCH AS CANADA), RESPECTIVELY.
<br />ONE NON-METALLIC PIPE
<br />02_H_BB_ULWL2241 _ONE NON-METALLIC PIPE_1-2HR SCALE: 1 1/2" = 1'-0"
<br />FIRE RESISTANCE LISTING:
<br />U.L. DESIGN NO.
<br />W-L-2241
<br />FIRE RATING:
<br />1-HR or 2-HR
<br />SYSTEM NO. W-L-1222
<br />F RATINGS - 1 AND 2 HR (SEE ITEM 1)
<br />T RATINGS - 1/4, 3/4 AND 1 HR (SEE ITEM 2)
<br />1.WALL ASSEMBLY - THE 1 OR 2 HR FIRE-RATED GYPSUM BOARD/STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE
<br />MATERIALS AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL U300 OR U400 SERIES WALL OR PARTITION DESIGN IN THE UL
<br />FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES:
<br />A.STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF
<br />NOM 2 BY 4 IN. (51 BY 102 MM) LUMBER SPACED 16 IN. (406 MM) OC. STEEL STUDS TO BE MIN 3-1/2 IN. (89 MM) WIDE AND
<br />SPACED MAX 24 IN. (610 MM) OC.
<br />B.GYPSUM BOARD* - THICKNESS, TYPE, NUMBER OF LAYERS AND FASTENERS AS SPECIFIED IN THE INDIVIDUAL WALL AND
<br />PARTITION DESIGN. MAX DIAM OF OPENING IS 10-5/8 IN. (270 MM).
<br />THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS EQUAL TO THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN
<br />WHICH IT IS INSTALLED.
<br />2.THROUGH PENETRANT - ONE METALLIC PIPE, CONDUIT OR TUBE TO BE INSTALLED ECCENTRICALLY OR CONCENTRICALLY
<br />WITHIN THE FIRESTOP SYSTEM. PIPE, CONDUIT OR TUBING MAY BE INSTALLED AT AN ANGLE NOT GREATER THAN 45 DEGREES
<br />FROM PERPENDICULAR. THE ANNULAR SPACE BETWEEN THE PIPE, CONDUIT OR TUBE AND THE PERIPHERY OF THE OPENING
<br />SHALL BE MIN 0 IN. (0 MM, POINT CONTACT) TO MAX 2 IN. (51 MM). PIPE, CONDUIT OR TUBE TO BE RIGIDLY SUPPORTED ON BOTH
<br />SIDES OF THE WALL ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF METALLIC PIPES, CONDUITS AND TUBES MAY BE USED:
<br />A.STEEL PIPE - NOM 8 IN. (203 MM) DIAM (OR SMALLER) SCHEDULE 5 (OR HEAVIER) STEEL PIPE.
<br />B.IRON PIPE - NOM 8 IN. (203 MM) DIAM (OR SMALLER) CAST OR DUCTILE IRON PIPE.
<br />C.CONDUIT - NOM 6 IN. (152 MM) DIAM (OR SMALLER) RIGID STEEL CONDUIT, NOM 4 IN. (102 MM) DIAM (OR SMALLER) STEEL
<br />ELECTRICAL METALLIC TUBING (EMT) OR NOM 4 IN. (102 MM) DIAM (OR SMALLER) FLEXIBLE STEEL CONDUIT.
<br />D.COPPER PIPE - NOM 4 IN. (102 MM) DIAM (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE.
<br />E.COPPER TUBE - NOM 4 IN. (102 MM) DIAM (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBE.
<br />2A. THROUGH PENETRATING PRODUCT* - FLEXIBLE METAL PIPING - AS AN ALTERNATE TO ITEM 2, ONE NOM 1-1/4 IN. (32 MM) DIAM
<br />(OR SMALLER) STEEL FLEXIBLE METAL PIPE TO BE INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE
<br />FIRESTOP SYSTEM. THE ANNULAR SPACE BETWEEN THE PIPE AND THE PERIPHERY OF THE OPENING SHALL BE MIN 0 IN. (0 MM,
<br />POINT CONTACT) TO MAX 2 IN. (51 MM). PIPE TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF THE WALL ASSEMBLY.
<br />OMEGA FLEX INC
<br />GASTITE, DIV OF TITEFLEX
<br />WARD MFG L L C
<br />3.FILL, VOID OR CAVITY MATERIAL* - SEALANT - MIN 5/8 IN. (16 MM) THICKNESS OF FILL MATERIAL APPLIED WITHIN ANNULUS,
<br />FLUSH WITH BOTH SURFACES OF WALL ASSEMBLY. AT POINT CONTACT LOCATION, MIN 1/4 IN. (6 MM) DIAM BEAD OF FILL
<br />MATERIAL APPLIED AT METALLIC PIPE/GYPSUM BOARD INTERFACE ON BOTH SURFACES OF WALL.
<br />SPECIFIED TECHNOLOGIES INC - SPECSEAL LCI SEALANT
<br />*INDICATES SUCH PRODUCTS SHALL BEAR THE UL OR CUL CERTIFICATION MARK FOR JURISDICTIONS EMPLOYING THE UL OR
<br />CUL CERTIFICATION (SUCH AS CANADA), RESPECTIVELY.
<br />ONE METALLIC PIPE
<br />02_H_BB_ULWL1222_ONE METALLIC PIPE_1-2HR SCALE: 1 1/2" = 1'-0"
<br />FIRE RESISTANCE LISTING:
<br />U.L. DESIGN NO.
<br />W-L-1222
<br />FIRE RATING:
<br />1-HR or 2-HR
<br />TYPE OF PENETRANT
<br />STEEL OR IRON PIPE, STEEL CONDUIT OR EMT
<br />T RATING
<br />1 HR
<br />3/4 HR
<br />2 IN. (51 MM)
<br />8 IN. (203 MM)STEEL OR IRON PIPE, STEEL CONDUIT OR EMT
<br />MAX DIAM
<br />4 IN. (102 MM)COPPER PIPE OR TUBE 1/4 HR
<br />1A
<br />1B
<br />2
<br />3 3
<br />SYSTEM NO. W-L-3170
<br />F RATINGS - 1 AND 2 HR (SEE ITEM 1)
<br />T RATINGS - 1/4 AND 1 HR (SEE ITEM 3A)
<br />1.WALL ASSEMBLY - THE 1 OR 2 HR FIRE-RATED GYPSUM BOARD/STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN
<br />THE MANNER SPECIFIED IN THE INDIVIDUAL U300 OR U400 SERIES WALL OR PARTITION DESIGN IN THE UL FIRE RESISTANCE DIRECTORY AND
<br />SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES:
<br />A.STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN.
<br />LUMBER SPACED 16 IN. OC. STEEL STUDS TO BE MIN 3-5/8 IN. WIDE AND SPACED MAX 24 IN. OC.
<br />B.GYPSUM BOARD* - THICKNESS, TYPE, NUMBER OF LAYERS AND FASTENERS AS SPECIFIED IN THE INDIVIDUAL WALL AND PARTITION
<br />DESIGN. MAX DIAM OF OPENING IS 6 IN.
<br />THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS EQUAL TO THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS
<br />INSTALLED.
<br />2.STEEL SLEEVE - CYLINDRICAL SLEEVE FABRICATED FROM 0.0125 IN. THICK (30 GAUGE) GALV SHEET STEEL AND HAVING A MIN 2 IN. LAP
<br />ALONG THE LONGITUDINAL SEAM. LENGTH OF THE SLEEVE TO BE EQUAL TO OR MAX 2 IN. GREATER THAN THE THICKNESS OF THE WALL.
<br />SLEEVE INSTALLED BY COILING THE SHEET STEEL TO A DIAM SMALLER THAN THE THROUGH OPENING, INSERTING THE COIL THROUGH THE
<br />OPENING AND RELEASING THE COIL TO LET IT UNCOIL AGAINST THE CIRCULAR CUTOUTS IN THE GYPSUM WALLBOARD LAYERS. THE ENDS OF
<br />THE STEEL SLEEVE SHALL BE FLUSH WITH OR EXTEND A MAX 1 IN. BEYOND EACH SURFACE OF THE WALL.
<br />AS AN ALTERNATE, STEEL SLEEVE MAY CONSIST OF NOM 6 IN. DIAM (OR SMALLER) SCHEDULE 5 (OR HEAVIER) STEEL PIPE SLEEVE
<br />FRICTION-FITTED INTO CIRCULAR CUTOUTS IN THE GYPSUM BOARD LAYERS. THE ENDS OF THE STEEL SLEEVE SHALL BE FLUSH WITH OR
<br />EXTEND A MAX 1 IN. BEYOND EACH SURFACE OF THE WALL.
<br />3.CABLES - MAX 4-1/2 IN. DIAM TIGHT BUNDLE OF CABLES TO BE INSTALLED ECCENTRICALLY OR CONCENTRICALLY WITHIN THE OPENING. THE
<br />ANNULAR SPACE BETWEEN THE CABLES AND THE PERIPHERY OF THE OPENING SHALL BE MIN 0 IN. (POINT CONTACT) TO MAX 1-1/2 IN. CABLE
<br />BUNDLE TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF THE WALL ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF CABLES MAY BE USED:
<br />A.MAX 200 PAIR NO. 24 AWG (OR SMALLER) COPPER CONDUCTOR WITH POLYVINYL CHLORIDE (PVC) INSULATION AND JACKETING MATERIAL.
<br />B.MAX 1/C NO. 350 KCMIL (OR SMALLER) COPPER CONDUCTOR CABLE WITH CROSS-LINKED POLYETHYLENE (XLPE) JACKET.
<br />C.MAX 7/C NO. 12 AWG (OR SMALLER) COPPER CONDUCTOR POWER AND CONTROL CABLES WITH XLPE OR PVC INSULATION WITH XLPE OR
<br />PVC JACKET.
<br />D.MAX 3/C NO. 2/0 AWG (OR SMALLER) COPPER OR ALUMINUM CONDUCTOR SER CABLES WITH PVC INSULATION AND JACKET.
<br />E.MAX 3/C NO. 2/0 AWG (OR SMALLER) COPPER CONDUCTOR PVC JACKETED ALUMINUM CLAD OR STEEL CLAD TEK CABLE.
<br />F.MAX 110/125 FIBER OPTIC (F.O.) CABLE WITH PVC INSULATION AND JACKET.
<br />G.MAX 3/C WITH GROUND NO. 8 AWG (OR SMALLER) COPPER CONDUCTOR NM CABLE (ROMEX) WITH PVC INSULATION AND JACKET.
<br />H.MAX RG/U COAXIAL CABLE WITH FLUORINATED ETHYLENE INSULATION AND JACKET.
<br />I.MAX 4 PAIR NO. 24 AWG (OR SMALLER) COPPER CONDUCTOR DATA CABLE WITH HYLAR JACKET AND INSULATION.
<br />3A.THROUGH PENETRATING PRODUCT* - AS AN ALTERNATE TO THE CABLES (ITEM 3), MAX 4-1/2 IN. DIAM TIGHT BUNDLE OF MAX 4/C NO. 2/0 AWG
<br />(OR SMALLER) ALUMINUM OR STEEL ARMORED CABLE+ OR METAL CLAD CABLE+ INSTALLED WITHIN THE OPENING. ANNULAR SPACE
<br />BETWEEN THROUGH-PENETRATING PRODUCTS AND PERIPHERY OF OPENING TO BE MIN 0 IN. (POINT CONTACT) TO MAX 1-1/2 IN. THROUGH
<br />PENETRATING PRODUCT RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. WHEN ARMORED CABLE OR METAL CLAD CABLE IS
<br />USED, T RATING IS 1/4 HR.
<br />AFC CABLE SYSTEMS INC
<br />4.FIRESTOP SYSTEM - THE FIRESTOP SYSTEM SHALL CONSIST OF THE FOLLOWING:
<br />A.PACKING MATERIAL - MIN 1 IN. THICKNESS OF 4 PCF MINERAL WOOL BATT INSULATION COMPRESSED AND TIGHTLY PACKED INTO EACH
<br />END OF SLEEVE. RECESS PACKING MATERIAL AS REQUIRED TO ACCOMMODATE FILL MATERIAL (ITEM 4B).
<br />B.FILL, VOID OR CAVITY MATERIAL* - SEALANT - MIN 1/2 IN. THICKNESS OF FILL MATERIAL APPLIED WITHIN ANNULUS, FLUSH WITH EACH END
<br />OF STEEL SLEEVE. AT POINT CONTACT LOCATION, MIN 1/4 IN. DIAM BEAD OF FILL MATERIAL APPLIED AT CABLE BUNDLE/STEEL SLEEVE
<br />INTERFACE ON BOTH SIDES OF WALL.
<br />SPECIFIED TECHNOLOGIES INC - SPECSEAL LCI SEALANT
<br />*INDICATES SUCH PRODUCTS SHALL BEAR THE UL OR CUL CERTIFICATION MARK FOR JURISDICTIONS EMPLOYING THE UL OR CUL
<br />CERTIFICATION (SUCH AS CANADA), RESPECTIVELY.
<br />CABLE - MAX. 4 1/2" WITH STEEL
<br />02_H_BB_ULWL3170 _CABLE 4.5 INCH WITH STEEL_1-2HR SCALE: 1 1/2" = 1'-0"
<br />FIRE RESISTANCE LISTING:
<br />U.L. DESIGN NO.
<br />W-L-3170
<br />FIRE RATING:
<br />1-HR or 2-HR
<br />A
<br />Section A-A
<br />1A
<br />1B
<br />2
<br />3
<br />3
<br />2
<br />4B 4B 4A
<br />A
<br />SYSTEM NO. W-L-3169
<br />F RATINGS - 1 AND 2 HR (SEE ITEM 1)
<br />T RATINGS - 1/4 AND 3/4 HR (SEE ITEM 2A)
<br />1.WALL ASSEMBLY - THE 1 OR 2 HR FIRE-RATED GYPSUM BOARD/STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE
<br />MATERIALS AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL U300 OR U400 SERIES WALL OR PARTITION DESIGN IN THE UL
<br />FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES:
<br />A.STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF
<br />NOM 2 BY 4 IN. (51 BY 102 MM) LUMBER SPACED 16 IN. (406 MM) OC. STEEL STUDS TO BE MIN 3-5/8 IN. (92 MM) WIDE AND
<br />SPACED MAX 24 IN. (610 MM) OC.
<br />B.GYPSUM BOARD* - THICKNESS, TYPE, NUMBER OF LAYERS AND FASTENERS AS SPECIFIED IN THE INDIVIDUAL WALL AND
<br />PARTITION DESIGN. MAX DIAM OF OPENING IS 5 IN. (127 MM).
<br />THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS EQUAL TO THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN
<br />WHICH IT IS INSTALLED.
<br />2.CABLES - MAX 4-1/2 IN. DIAM TIGHT BUNDLE OF CABLES TO BE INSTALLED ECCENTRICALLY OR CONCENTRICALLY WITHIN THE
<br />OPENING. THE ANNULAR SPACE BETWEEN THE CABLES AND THE PERIPHERY OF THE OPENING SHALL BE MIN 0 IN. (0 MM, POINT
<br />CONTACT) TO MAX 1/2 IN. (13 MM). CABLE BUNDLE TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF THE FLOOR OR WALL
<br />ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF CABLES MAY BE USED:
<br />A.MAX 200 PAIR NO. 24 AWG (OR SMALLER) COPPER CONDUCTOR WITH POLYVINYL CHLORIDE (PVC) INSULATION AND
<br />JACKETING MATERIAL.
<br />B.MAX 1/C NO. 350 KCMIL (OR SMALLER) COPPER CONDUCTOR CABLE WITH CROSS-LINKED POLYETHYLENE (XLPE) JACKET.
<br />C.MAX 7/C NO. 12 AWG (OR SMALLER) COPPER CONDUCTOR POWER AND CONTROL CABLES WITH XLPE OR PVC INSULATION
<br />WITH XLPE OR PVC JACKET.
<br />D.MAX 3/C NO. 2/0 AWG (OR SMALLER) COPPER OR ALUMINUM CONDUCTOR SER CABLES WITH PVC INSULATION AND JACKET.
<br />E.MAX 3/C NO. 2/0 AWG (OR SMALLER) COPPER CONDUCTOR PVC JACKETED ALUMINUM CLAD OR STEEL CLAD TEK CABLE.
<br />F.MAX 110/125 FIBER OPTIC (F.O.) CABLE WITH PVC INSULATION AND JACKET.
<br />G.MAX 3/C WITH GROUND NO. 8 AWG (OR SMALLER) COPPER CONDUCTOR NM CABLE (ROMEX) WITH PVC INSULATION AND
<br />JACKET.
<br />H.MAX RG/U COAXIAL CABLE WITH FLUORINATED ETHYLENE INSULATION AND JACKET.
<br />I.MAX 4 PAIR NO. 24 AWG (OR SMALLER) COPPER CONDUCTOR DATA CABLE WITH HYLAR JACKET AND INSULATION.
<br />J.MAX 4/C (WITH GROUND) NO. 300 KCMIL (OR SMALLER) ALUMINUM CONDUCTOR SER CABLES WITH PVC INSULATION AND
<br />JACKET.
<br />2A. THROUGH PENETRATING PRODUCT* - AS AN ALTERNATE TO THE CABLES (ITEM 2), MAX 4 IN. (102 MM) DIAM TIGHT BUNDLE OF
<br />MAX 4/C NO. 2/0 AWG (OR SMALLER) ALUMINUM OR STEEL ARMORED CABLE+ OR METAL CLAD CABLE+ INSTALLED WITHIN THE
<br />OPENING. ANNULAR SPACE BETWEEN THROUGH-PENETRATING PRODUCTS AND PERIPHERY OF OPENING TO BE MIN 0 IN. (0 MM,
<br />POINT CONTACT) TO MAX 1 IN. (25 MM). THROUGH PENETRATING PRODUCT RIGIDLY SUPPORTED ON BOTH SIDES OF FLOOR OR
<br />WALL ASSEMBLY. WHEN ARMORED CABLE OR METAL CLAD CABLE IS USED, T RATING IS 1/4 HR.
<br />AFC CABLE SYSTEMS INC
<br />3.FILL, VOID OR CAVITY MATERIAL* - SEALANT - MIN 5/8 IN. (16 MM) THICKNESS OF FILL MATERIAL APPLIED WITHIN ANNULUS,
<br />FLUSH WITH BOTH SURFACES OF WALL ASSEMBLY. SEALANT TO BE FORCED INTO INTERSTICES OF CABLE BUNDLE TO MAX
<br />EXTENT POSSIBLE. AT POINT CONTACT LOCATION, MIN 1/4 IN. (6 MM) DIAM BEAD OF FILL MATERIAL APPLIED AT CABLE
<br />BUNDLE/GYPSUM BOARD INTERFACE ON BOTH SURFACES OF WALL.
<br />SPECIFIED TECHNOLOGIES INC - SPECSEAL LCI SEALANT
<br />*INDICATES SUCH PRODUCTS SHALL BEAR THE UL OR CUL CERTIFICATION MARK FOR JURISDICTIONS EMPLOYING THE UL OR
<br />CUL CERTIFICATION (SUCH AS CANADA), RESPECTIVELY.
<br />CABLE - MAX. 4 1/2"
<br />02_H_BB_ULWL3169 _CABLE 4.5 INCH_1-2HR SCALE: 1 1/2" = 1'-0"
<br />FIRE RESISTANCE LISTING:
<br />U.L. DESIGN NO.
<br />W-L-3169
<br />FIRE RATING:
<br />1-HR or 2-HR
<br />A
<br />Section A-AA
<br />1B
<br />33
<br />2
<br />2
<br />1A
<br />SYSTEM NO. W-L-3171
<br />F RATINGS - 1 AND 2 HR (SEE ITEM 1)
<br />T RATINGS - 1/4 AND 3/4 HR (SEE ITEM 2A)
<br />1.WALL ASSEMBLY - THE 1 OR 2 HR FIRE-RATED GYPSUM BOARD/STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE
<br />MATERIALS AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL U300 OR U400 SERIES WALL OR PARTITION DESIGN IN THE UL
<br />FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES:
<br />A.STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF
<br />NOM 2 BY 4 IN. LUMBER SPACED 16 IN. OC. STEEL STUDS TO BE MIN 3-5/8 IN. WIDE AND SPACED MAX 24 IN. OC.
<br />B.GYPSUM BOARD* - THICKNESS, TYPE, NUMBER OF LAYERS AND FASTENERS AS SPECIFIED IN THE INDIVIDUAL WALL AND
<br />PARTITION DESIGN. MAX DIAM OF OPENING IS 1 IN. LARGER THAN OD OF CABLE (ITEM 2).
<br />THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS EQUAL TO THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN
<br />WHICH IT IS INSTALLED.
<br />2.CABLE - ONE CABLE TO BE INSTALLED ECCENTRICALLY OR CONCENTRICALLY WITHIN THE OPENING. THE ANNULAR SPACE
<br />BETWEEN THE CABLE AND THE PERIPHERY OF THE OPENING SHALL BE MIN 0 IN. (POINT CONTACT) TO MAX 1 IN. CABLE TO BE
<br />RIGIDLY SUPPORTED ON BOTH SIDES OF THE FLOOR OR WALL ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF CABLE MAY
<br />BE USED:
<br />A.MAX 200 PAIR NO. 24 AWG (OR SMALLER) COPPER CONDUCTOR WITH POLYVINYL CHLORIDE (PVC) INSULATION AND
<br />JACKETING MATERIAL.
<br />B.MAX 1/C NO. 350 KCMIL (OR SMALLER) COPPER CONDUCTOR CABLE WITH CROSS-LINKED POLYETHYLENE (XLPE) JACKET.
<br />C.MAX 7/C NO. 12 AWG (OR SMALLER) COPPER CONDUCTOR POWER AND CONTROL CABLES WITH XLPE OR PVC INSULATION
<br />WITH XLPE OR PVC JACKET.
<br />D.MAX 3/C NO. 2/0 AWG (OR SMALLER) COPPER OR ALUMINUM CONDUCTOR SER CABLES WITH PVC INSULATION AND JACKET.
<br />E.MAX 3/C NO. 2/0 AWG (OR SMALLER) COPPER CONDUCTOR PVC JACKETED ALUMINUM CLAD OR STEEL CLAD TEK CABLE.
<br />F.MAX 110/125 FIBER OPTIC (F.O.) CABLE WITH PVC INSULATION AND JACKET.
<br />G.MAX 3/C WITH GROUND NO. 8 AWG (OR SMALLER) COPPER CONDUCTOR NM CABLE (ROMEX) WITH PVC INSULATION AND
<br />JACKET.
<br />H.MAX RG/U COAXIAL CABLE WITH FLUORINATED ETHYLENE INSULATION AND JACKET.
<br />I.MAX 4 PAIR NO. 24 AWG (OR SMALLER) COPPER CONDUCTOR DATA CABLE WITH HYLAR JACKET AND INSULATION.
<br />2A. THROUGH PENETRATING PRODUCT* - AS AN ALTERNATE TO THE CABLE (ITEM 2), ONE MAX 4/C NO. 2/0 AWG (OR SMALLER)
<br />ALUMINUM OR STEEL ARMORED CABLE+ OR METAL CLAD CABLE+ INSTALLED WITHIN THE OPENING. ANNULAR SPACE
<br />BETWEEN THROUGH-PENETRATING PRODUCT AND PERIPHERY OF OPENING TO BE MIN 0 IN. (POINT CONTACT) TO MAX 1 IN.
<br />THROUGH PENETRATING PRODUCT RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. WHEN ARMORED CABLE OR
<br />METAL CLAD CABLE IS USED, T RATING IS 1/4 HR.
<br />AFC CABLE SYSTEMS INC
<br />3.FILL, VOID OR CAVITY MATERIAL* - SEALANT - MIN 5/8 IN. THICKNESS OF FILL MATERIAL APPLIED WITHIN ANNULUS, FLUSH WITH
<br />BOTH SURFACES OF WALL ASSEMBLY. AT POINT CONTACT LOCATION, MIN 1/4 IN. DIAM BEAD OF FILL MATERIAL APPLIED AT
<br />CABLE/GYPSUM BOARD INTERFACE ON BOTH SURFACES OF WALL.
<br />SPECIFIED TECHNOLOGIES INC - SPECSEAL LCI SEALANT
<br />*INDICATES SUCH PRODUCTS SHALL BEAR THE UL OR CUL CERTIFICATION MARK FOR JURISDICTIONS EMPLOYING THE UL OR
<br />CUL CERTIFICATION (SUCH AS CANADA), RESPECTIVELY.
<br />CABLE - SINGLE
<br />02_H_BB_ULWL3171 _CABLE SINGLE_1-2HR SCALE: 1 1/2" = 1'-0"
<br />FIRE RESISTANCE LISTING:
<br />U.L. DESIGN NO.
<br />W-L-3171
<br />FIRE RATING:
<br />1-HR or 2-HR
<br />A
<br />Section A-A
<br />1A
<br />2
<br />2
<br />33
<br />1BA
<br />CABLES
<br />02_H_BB_ULFC3057_CABLES_1-2HR SCALE: N.T.S.
<br />FIRE RESISTANCE LISTING:
<br />U.L. DESIGN NO.
<br />FC-3057
<br />FIRE RATING:
<br />1 - 2 HR
<br />SYSTEM NO. F-C-3057
<br />F RATINGS - 1 HR AND 2 HR (SEE ITEM 1)
<br />T RATING - 1/2 HR
<br />1.FLOOR - CEILING ASSEMBLY - THE 1 HR FIRE-RATED WOOD JOIST FLOOR-CEILING ASSEMBLY SHALL BE CONSTRUCTED OF THE
<br />MATERIALS AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL L500 DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY. THE 2
<br />HR FIRE-RATED WOOD JOIST FLOOR-CEILING ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER
<br />SPECIFIED IN DESIGN NOS. L505, L511 OR L536 IN THE UL FIRE RESISTANCE DIRECTORY. THE F RATING OF THE FIRESTOP
<br />SYSTEM IS EQUAL TO THE FIRE RATING OF THE FLOOR-CEILING ASSEMBLY. THE GENERAL CONSTRUCTION FEATURES OF THE
<br />FLOOR ASSEMBLY ARE SUMMARIZED BELOW:
<br />A.FLOORING SYSTEM - LUMBER OR PLYWOOD SUBFLOOR WITH FINISH FLOOR OF LUMBER, PLYWOOD OR FLOOR TOPPING
<br />MIXTURE* AS SPECIFIED IN THE INDIVIDUAL FLOOR-CEILING DESIGN. MAX DIAM OF OPENING IS 3 IN. (76 MM).
<br />B.WOOD JOISTS - NOM 10 IN. (254 MM) DEEP (OR DEEPER) LUMBER, STEEL OR COMBINATION LUMBER AND STEEL JOISTS,
<br />TRUSSES OR STRUCTURAL WOOD MEMBERS* WITH BRIDGING AS REQUIRED AND WITH ENDS FIRESTOPPED.
<br />C.GYPSUM BOARD* - THICKNESS, TYPE, NUMBER OF LAYERS AND FASTENERS AS REQUIRED IN THE INDIVIDUAL FLOOR-CEILING
<br />DESIGN. MAX DIAM OF OPENING IS 3 IN. (76 MM).
<br />1A. CHASE WALL - (OPTIONAL, NOT SHOWN) - THE THROUGH PENETRANT (ITEM 2) MAY BE ROUTED THROUGH A 1 OR 2 HR FIRE
<br />RATED SINGLE, DOUBLE OR STAGGERED WOOD STUD/GYPSUM BOARD CHASE WALL. DEPTH OF CHASE WALL STUD CAVITY TO
<br />BE MIN 1/2 IN. (13 MM) GREATER THAN DIAMETER OF OPENING CUT IN SOLE AND TOP PLATES TO ACCOMMODATE THE THROUGH
<br />PENETRANT (ITEM 2). THE CHASE WALL SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER SPECIFIED IN THE
<br />INDIVIDUAL U300 SERIES WALL AND PARTITION DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE
<br />FOLLOWING CONSTRUCTION FEATURES:
<br />A.STUDS - NOM 2 BY 4 IN. (51 BY 102 MM), 2 BY 6 IN. (51 BY 162 MM) OR DOUBLE NOM 2 BY 4 IN. (51 BY 102 MM) LUMBER STUDS.
<br />B.SOLE PLATE - NOM 2 BY 4 IN. (51 BY 102 MM), 2 BY 6 IN. (51 BY 152 MM)OR PARALLEL 2 BY 4 IN. (51 BY 102 MM)LUMBER PLATES,
<br />TIGHTLY BUTTED. MAX DIAM OF OPENING IS 3 IN.
<br />C.TOP PLATE - THE DOUBLE TOP PLATE SHALL CONSIST OF TWO NOM 2 BY 4 IN. (51 BY 102 MM), TWO NOM 2 BY 6 IN. (51 BY 152
<br />MM)OR TWO SETS OF PARALLEL 2 BY 4 IN. (51 BY 102 MM)LUMBER PLATES, TIGHTLY BUTTED. MAX DIAM OF OPENING IS 3 IN.
<br />(76 MM).
<br />D.GYPSUM BOARD* - THICKNESS, TYPE, NUMBER OF LAYERS AND FASTENERS SHALL BE AS SPECIFIED IN THE INDIVIDUAL
<br />WALL AND PARTITION DESIGN.
<br />2.CABLES - AGGREGATE CROSS-SECTIONAL AREA OF CABLES WITHIN OPENING TO BE MAX 54 PERCENT OF THE
<br />CROSS-SECTIONAL AREA OF THE OPENING. ANNULAR SPACE TO BE MIN 0 IN. (POINT CONTACT) TO MAX 1-1/4 IN. (32 MM).
<br />PENETRANTS TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF FLOOR-CEILING ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF
<br />CABLES MAY BE USED:
<br />A.MAX 200 PAIR NO. 24 AWG (OR SMALLER) COPPER CONDUCTOR TELECOMMUNICATION CABLE WITH PVC INSULATION AND
<br />JACKETING.
<br />B.MAX 3/C NO. 3/0 AWG (OR SMALLER) ALUMINUM OR COPPER CONDUCTOR SER CABLE WITH PVC INSULATION AND JACKETING.
<br />C.MAX 3/C WITH GROUND NO. 8 AWG (OR SMALLER) TYPE NM (ROMEX) NONMETALLIC SHEATHED CABLE WITH PVC INSULATION
<br />AND JACKETING.
<br />D.MAX 1/C - 350 KCMIL (OR SMALLER) POWER CABLES WITH XLP INSULATION AND JACKETING.
<br />E.MAX 7/C NO. 12 AWG (OR SMALLER) POWER/CONTROL CABLES WITH PVC INSULATION AND JACKETING.
<br />F.MAX RG/U (OR SMALLER) COPPER CONDUCTOR COAXIAL CABLE WITH FLUORINATED ETHYLENE INSULATION AND JACKETING
<br />MATERIALS.
<br />G.MAX 4 PAIR NO. 24 AWG (OR SMALLER) COPPER CONDUCTOR DATA CABLE WITH HYLAR INSULATION AND JACKETING.
<br />H.MAX 4 PAIR NO. 18 AWG (OR SMALLER) COPPER CONDUCTOR INSTRUMENTATION CABLE WITH PVC INSULATION AND
<br />JACKETING.
<br />I.FIBER OPTIC CABLE WITH PVC INSULATION AND JACKETING.
<br />J.MAX 4/C (WITH GROUND) NO. 300 KCMIL (OR SMALLER) ALUMINUM CONDUCTOR SER CABLES WITH PVC INSULATION AND
<br />JACKET.
<br />2A. THROUGH PENETRATING PRODUCT* - (NOT SHOWN) AS AN ALTERNATE ITEM 3), ONE OR MORE THROUGH-PENETRATING
<br />PRODUCT TO BE INSTALLED WITHIN THE OPENING. MAX AGGREGATE CROSS-SECTIONAL AREA OF CABLES TO BE 52 PERCENT
<br />OF THE CROSS-SECTIONAL AREA OF THE OPENING. ANNULAR SPACE BETWEEN THROUGH-PENETRATING PRODUCTS AND
<br />PERIPHERY OF OPENING TO BE MIN 0 IN. (POINT CONTACT) TO MAX 1-1/4 IN. (32 MM). THROUGH PENETRATING PRODUCT
<br />RIGIDLY SUPPORTED ON BOTH SIDES OF FLOOR OR WALL ASSEMBLY. THE FOLLOWING TYPES OF THROUGH-PENETRATING
<br />PRODUCTS MAY BE USED:
<br />A.MAX 4/C WITH GROUND NO. 2/0 AWG (OR SMALLER) ALUMINUM OR COPPER CONDUCTOR ALUMINUM OR STEEL JACKETED
<br />ARMORED CABLE# + OR METAL-CLAD CABLE+.
<br />AFC CABLE SYSTEMS INC
<br />ENCORE WIRE CORP
<br />B.TWO OR MORE TWISTED COPPER CONDUCTORS NO. 6 AWG (OR SMALLER) POWER LIMITED CIRCUIT CABLE+ WITH OR
<br />WITHOUT A JACKET UNDER A METAL ARMOR.
<br />AFC CABLE SYSTEMS INC
<br />C.TWO OR MORE TWISTED COPPER CONDUCTORS NO. 10 AWG (OR SMALLER) POWER LIMITED FIRE ALARM CABLE+ WITH OR
<br />WITHOUT A JACKET UNDER A METAL ARMOR.
<br />AFC CABLE SYSTEMS INC
<br />D.MAX TWO TWISTED COPPER CONDUCTORS NO. 12 AWG (OR SMALLER) NON POWER LIMITED FIRE ALARM CABLE+ WITH OR
<br />WITHOUT A JACKET UNDER A METAL ARMOR.
<br />AFC CABLE SYSTEMS INC
<br />3.FILL, VOID OR CAVITY MATERIAL* - SEALANT - MIN 3/4 IN. (19 MM) THICKNESS OF FILL MATERIAL APPLIED WITHIN THE ANNULUS,
<br />FLUSH WITH THE TOP SURFACE OF THE FLOOR OR CHASE WALL SOLE PLATE. MIN 5/8 IN. (16 MM) THICKNESS OF FILL MATERIAL
<br />APPLIED WITHIN THE ANNULUS, FLUSH WITH BOTTOM SURFACE OF CEILING OR CHASE WALL TOP PLATE. AT POINT CONTACT,
<br />MIN 1/4 IN. (6 MM) DIAM BEAD OF FILL MATERIAL APPLIED AT CABLE BUNDLE/SUBFLOOR OR CHASE WALL SOLE PLATE
<br />INTERFACE AND AT CABLE BUNDLE/CEILING OR CHASE WALL TOP PLATE INTERFACE.
<br />SPECIFIED TECHNOLOGIES INC - SPECSEAL LCI SEALANT
<br />+BEARING THE UL LISTING MARK
<br />**INDICATES SUCH PRODUCTS SHALL BEAR THE UL OR CUL CERTIFICATION MARK FOR JURISDICTIONS EMPLOYING THE UL OR
<br />CUL CERTIFICATION (SUCH AS CANADA), RESPECTIVELY.
<br />3
<br />Section A-A
<br />2 1A3
<br />1C
<br />3
<br />2
<br />1B
<br />A
<br />A
<br />SYSTEM NO. F-C-2032
<br />F RATING - 1 HR
<br />T RATINGS - 0, 1/4, 3/4 AND 1 HR (SEE ITEM 2)
<br />L RATING AT AMBIENT - LESS THAN 1 CFM/SQ FT
<br />L RATING AT 400 F - LESS THAN 1 CFM/SQ FT
<br />1.FLOOR - CEILING ASSEMBLY - THE 1 HR FIRE-RATED SOLID OR TRUSSED LUMBER JOIST FLOOR-CEILING ASSEMBLY SHALL BE
<br />CONSTRUCTED OF THE MATERIALS AND IN THE MANNER SPECIFIED IN INDIVIDUAL L500 SERIES FLOOR-CEILING DESIGNS IN THE
<br />UL FIRE RESISTANCE DIRECTORY. THE GENERAL CONSTRUCTION DETAILS OF THE FLOOR-CEILING ASSEMBLY ARE
<br />SUMMARIZED BELOW:
<br />A.FLOORING SYSTEM - LUMBER OR PLYWOOD SUBFLOOR WITH FINISH FLOOR OF LUMBER, PLYWOOD OR FLOOR TOPPING
<br />MIXTURE* AS SPECIFIED IN THE INDIVIDUAL FLOOR-CEILING DESIGN. MAX DIAM OF FLOOR OPENING IS 4 IN. (102 MM).
<br />B.WOOD JOISTS - NOM 2 BY 10 IN. (51 BY 254 MM) LUMBER JOISTS SPACED 16 IN. (406 MM) OC WITH NOM 1 BY 3 IN. (25 BY 76
<br />MM) LUMBER BRIDGING AND WITH ENDS FIRESTOPPED. AS AN ALTERNATE TO LUMBER JOISTS, NOM 10 IN. (254 MM) DEEP
<br />(OR DEEPER) LUMBER, STEEL OR COMBINATION LUMBER AND STEEL JOISTS, TRUSSES OR STRUCTURAL WOOD MEMBERS*
<br />WITH BRIDGING AS REQUIRED AND WITH ENDS FIRESTOPPED.
<br />C.FURRING CHANNELS - (NOT SHOWN) - RESILIENT GALV STEEL FURRING INSTALLED PERPENDICULAR TO WOOD JOISTS (ITEM
<br />1B) BETWEEN GYPSUM BOARD (ITEM 1D) AND WOOD JOISTS AS REQUIRED IN THE INDIVIDUAL FLOOR-CEILING DESIGN.
<br />D.GYPSUM BOARD* - NOM 4 FT (1.2 M) WIDE BY 5/8 IN. (16 MM) THICK AS SPECIFIED IN THE INDIVIDUAL FLOOR-CEILING DESIGN.
<br />GYPSUM BOARD SECURED TO WOOD JOISTS OR FURRING CHANNELS AS SPECIFIED IN THE INDIVIDUAL FLOOR-CEILING
<br />DESIGN. MAX DIAM OF CEILING OPENING IS 4 IN. (102 MM).
<br />1.1 CHASE WALL - (OPTIONAL. NOT SHOWN) - THE THROUGH PENETRANT (ITEM NO. 2) MAY BE ROUTED THROUGH A FIRE RATED OR
<br />NON FIRE RATED SINGLE, DOUBLE OR STAGGERED WOOD STUD/GYPSUM BOARD CHASE WALL. WHEN FIRE RATED THE CHASE
<br />WALL SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL U300 SERIES WALL AND
<br />PARTITION DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION
<br />FEATURES:
<br />A.STUDS - NOM 2 BY 4 IN. (51 BY 102 MM), 2 BY 6 IN. (51 BY 152 MM) OR DOUBLE 2 BY 4 IN. (51 BY 102 MM) LUMBER STUDS.
<br />B.SOLE PLATE - NOM 2 BY 4 IN. (51 BY 102 MM), 2 BY 6 IN. (51 BY 152 MM) OR PARALLEL 2 BY 4 IN. (51 BY 102 MM) LUMBER
<br />PLATES, TIGHTLY BUTTED.
<br />C.TOP PLATE - THE DOUBLE TOP PLATE SHALL CONSIST OF TWO NOM 2 BY 4 IN. (51 BY 102 MM) OR 2 BY 6 IN. (51 BY 152 MM) OR
<br />TWO SETS OF PARALLEL 2 BY 4 IN. (51 BY 102 MM) LUMBER PLATES, TIGHTLY BUTTED. MAX DIAM OF OPENING IS 4 IN. (102
<br />MM).
<br />D.GYPSUM BOARD* - THICKNESS, TYPE, NUMBER OF LAYERS AND FASTENERS SHALL BE AS SPECIFIED IN INDIVIDUAL WALL
<br />AND PARTITION DESIGN.
<br />2.THROUGH-PENETRANTS - ONE NONMETALLIC PIPE, CONDUIT OR TUBING TO BE INSTALLED WITHIN THE FIRESTOP SYSTEM.
<br />DIAM OF OPENINGS HOLE-SAWED THROUGH FLOORING SYSTEM AND THROUGH GYPSUM BOARD CEILING TO BE 1/4 TO 1-5/8 IN.
<br />(6 TO 41 MM) LARGER THAN THE OUTSIDE DIAM OF THROUGH-PENETRANT. PIPE, CONDUIT OR TUBING TO BE RIGIDLY
<br />SUPPORTED ON BOTH SIDES OF THE FLOOR-CEILING ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF NONMETALLIC PIPES,
<br />CONDUITS OR TUBING MAY BE USED:
<br />A.POLYVINYL CHLORIDE (PVC) PIPE - NOM 2 IN. (51 MM) DIAM (OR SMALLER) SCHEDULE 40 SOLID OR CELLULAR CORE PVC PIPE
<br />FOR USE IN CLOSED (PROCESS OR SUPPLY) OR VENTED (DRAIN, WASTE OR VENT) PIPING SYSTEMS. THE T RATING FOR THE
<br />FIRESTOP SYSTEM WHEN THIS PENETRANT IS USED IS 1 HR EXCEPT THAT WHEN NOM DIAM OF PIPE EXCEEDS 1 IN. (25 MM),
<br />THE T RATING IS 1/4 HR.
<br />B.RIGID NONMETALLIC CONDUIT (RNC)+ - NOM 2 IN. (51 MM) DIAM (OR SMALLER) SCHEDULE 40 PVC CONDUIT INSTALLED IN
<br />ACCORDANCE WITH ARTICLE 347 OF THE NATIONAL ELECTRICAL CODE (NFPA NO. 70). THE T RATING FOR THE FIRESTOP
<br />SYSTEM WHEN THIS PENETRANT IS USED IS 1 HR EXCEPT THAT WHEN NOM DIAM OF PIPE EXCEEDS 1 IN. (25 MM), THE T
<br />RATING IS 1/4 HR.
<br />C.CHLORINATED POLYVINYL CHLORIDE (CPVC) PIPE - NOM 2 IN. (51 MM) DIAM (OR SMALLER) SDR 17 CPVC PIPE FOR USE IN
<br />CLOSED (PROCESS OR SUPPLY) OR VENTED (DRAIN, WASTE OR VENT) PIPING SYSTEMS. THE T RATING FOR THE FIRESTOP
<br />SYSTEM WHEN THIS PENETRANT IS USED IS 1 HR EXCEPT THAT WHEN NOM DIAM OF PIPE EXCEEDS 1 IN. (25 MM), THE T
<br />RATING IS 1/4 HR.
<br />D.ACRYLONITRILE BUTADIENE STYRENE (ABS) PIPE - NOM 2 IN. (51 MM) DIAM (OR SMALLER) SCHEDULE 40 CELLULAR OR SOLID
<br />CORE ABS PIPE FOR USE IN CLOSED (PROCESS OR SUPPLY) OR VENTED (DRAIN, WASTE OR VENT) PIPING SYSTEMS. THE T
<br />RATING FOR THE FIRESTOP SYSTEM WHEN THIS PENETRANT IS USED IS 0 HR.
<br />E.POLYBUTYLENE (PB) PIPE - NOM 1 IN. (25 MM) DIAM (OR SMALLER) SDR 11 PB PIPE FOR USE IN CLOSED (PROCESS OR
<br />SUPPLY) PIPING SYSTEMS. THE T RATING FOR THE FIRESTOP SYSTEM WHEN THIS PENETRANT IS USED IS 1 HR.
<br />F.CROSS LINKED POLYETHYLENE ALUMINUM-CROSS LINKED POLYETHYLENE (PEX AL-PEX) TUBING - NOM 1 IN. (25 MM) DIAM
<br />(OR SMALLER) SDR 5 PEX-AL-PEX TUBING FOR USE IN CLOSED (PROCESS OR SUPPLY) PIPING SYSTEMS. THE T RATING FOR
<br />THE FIRESTOP SYSTEM WHEN THIS PENETRANT IS USED IS 3/4 HR.
<br />G.CROSS LINKED POLYETHYLENE (PEX) TUBING - NOM 2 IN. (51 MM) DIAM (OR SMALLER) SDR 9 PEX TUBING FOR USE IN
<br />CLOSED (PROCESS OR SUPPLY) PIPING SYSTEMS. THE T RATING FOR THE FIRESTOP SYSTEM WHEN THIS PENETRANT IS
<br />USED IS 1 HR.
<br />H.ELECTRICAL NONMETALLIC TUBING (ENT)+ - NOM 2 IN. (51 MM) DIAM (OR SMALLER) PVC TUBING INSTALLED IN ACCORDANCE
<br />WITH ARTICLE 331 OF THE NATIONAL ELECTRICAL CODE (NFPA NO. 70). THE T RATING FOR THE FIRESTOP SYSTEM WHEN
<br />THIS PENETRANT IS USED IS 1 HR EXCEPT THAT WHEN NOM DIAM OF TUBE EXCEEDS 1 IN. (25 MM), THE T RATING IS 1/4 HR.
<br />I.CHLORINATED POLYVINYL CHLORIDE (CPVC) PIPE - NOM 2 IN. (51 MM) DIAM (OR SMALLER) SCHEDULE 80 CPVC PIPE FOR USE
<br />IN CLOSED (PROCESS OR SUPPLY) PIPING SYSTEMS.
<br />WHEN 2A, 2B, 2C, 2E, 2F, 2G, 2H OR 2I IS USED, THE ANNULAR SPACE SHALL BE MIN 0 IN. (POINT CONTACT) TO MAX 1-5/8 IN. (41
<br />MM). WHEN 2D IS USED, THE ANNULAR SPACE SHALL BE MIN 0 IN. (POINT CONTACT) TO MAX 1 IN. (25 MM) EXCEPT THAT
<br />WHEN NOM PIPE DIAM EXCEEDS 1-1/2 IN. (38 MM), THE MAX ANNULAR SPACE IS 5/8 IN. (16 MM).
<br />3.FILL, VOID OR CAVITY MATERIAL* - SEALANT - MIN 3/4 IN. (19 MM) THICKNESS OF FILL MATERIAL APPLIED WITHIN ANNULUS ON
<br />TOP SURFACE OF FLOOR. MIN 5/8 IN. (16 MM) THICKNESS OF FILL MATERIAL APPLIED WITHIN ANNULUS ON BOTTOM SURFACE OF
<br />CEILING OR LOWER TOP PLATE OF CHASE WALL ASSEMBLY. ADDITIONAL FILL MATERIAL TO BE INSTALLED SUCH THAT A MIN 1/8
<br />IN. (3 MM) CROWN IS FORMED AROUND THE THROUGH PENETRANT ON BOTTOM SURFACE OF CEILING OR LOWER PLATE OF
<br />CHASE WALL ASSEMBLY.
<br />SPECIFIED TECHNOLOGIES INC - SPECSEAL SERIES SSS SEALANT, R SPECSEAL LCI SEALANT, OR TYPE WF300 FIRESTOP CAULK
<br />+BEARING THE UL LISTING MARK
<br />*BEARING THE UL CLASSIFICATION MARKING
<br />PIPE, CONDUIT, ALUMINUM OR TUBING
<br />02_H_BB_ULFC2032 _SINGLE NON-METALLIC 2" PIPE_1HR SCALE: 1 1/2" = 1'-0"
<br />FIRE RESISTANCE LISTING:
<br />U.L. DESIGN NO.
<br />F-C-2032
<br />FIRE RATING:
<br />1-HR
<br />2
<br />3
<br />1A
<br />1B
<br />3 2
<br />1C 3
<br />1.FLOOR - CEILING ASSEMBLY - THE 1 HR FIRE-RATED WOOD JOIST FLOOR-CEILING ASSEMBLY SHALL BE CONSTRUCTED OF THE
<br />MATERIALS AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL L500 DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY. THE 2
<br />HR FIRE-RATED WOOD JOIST FLOOR-CEILING ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER
<br />SPECIFIED IN DESIGN NOS. L505, L511 OR L536 IN THE UL FIRE RESISTANCE DIRECTORY. THE F AND FH RATINGS OF THE
<br />FIRESTOP SYSTEM ARE EQUAL TO THE FIRE RATING OF THE FLOOR-CEILING ASSEMBLY. THE GENERAL CONSTRUCTION
<br />FEATURES OF THE FLOOR ASSEMBLY ARE SUMMARIZED BELOW:
<br />A.FLOORING SYSTEM - LUMBER OR PLYWOOD SUBFLOOR WITH FINISH FLOOR OF LUMBER, PLYWOOD OR FLOOR TOPPING
<br />MIXTURE* AS SPECIFIED IN THE INDIVIDUAL FLOOR-CEILING DESIGN. DIAM OF OPENING TO BE MAX 1 IN. (25 MM) LARGER
<br />THAN DIAM OF PIPE. AS AN ALTERNATE, THE OPENING MAY BE SQUARE-CUT WITH A MAX DIMENSION 1 IN. (25 MM) GREATER
<br />THAN THE DIAM OF THE PIPE.
<br />B.WOOD JOISTS - NOM 10 IN. (254 MM) DEEP (OR DEEPER) LUMBER, STEEL OR COMBINATION LUMBER AND STEEL JOISTS,
<br />TRUSSES OR STRUCTURAL WOOD MEMBERS* WITH BRIDGING AS REQUIRED AND WITH ENDS FIRESTOPPED.
<br />C.GYPSUM BOARD* - THICKNESS, TYPE, NUMBER OF LAYERS AND FASTENERS AS REQUIRED IN THE INDIVIDUAL
<br />FLOOR-CEILING DESIGN. DIAM OF OPENING TO BE MAX 1 IN. (25 MM) GREATER THAN DIAM OF PIPE.
<br />D.FURRING CHANNEL - (NOT SHOWN) - IN 2 HR FIRE-RATED ASSEMBLIES, RESILIENT GALV STEEL FURRING CHANNELS
<br />INSTALLED PERPENDICULAR TO WOOD JOISTS BETWEEN BASE AND FACE LAYERS OF GYPSUM BOARD (ITEM C). FURRING
<br />CHANNELS SPACED MAX 24 IN. (610 MM) OC WITH ADDITIONAL SHORT LENGTHS OF FURRING CHANNEL INSTALLED ADJACENT
<br />TO AND MAX 3 IN. (76 MM) FROM TWO OPPOSING SIDES OF PENETRANT.
<br />1A. CHASE WALL - (OPTIONAL, NOT SHOWN) - THE THROUGH PENETRANT (ITEM 2) MAY BE ROUTED THROUGH A SINGLE, DOUBLE
<br />OR STAGGERED WOOD STUD/GYPSUM BOARD CHASE WALL. DEPTH OF CHASE WALL STUD CAVITY TO BE MIN 1 IN. (25 MM)
<br />GREATER THAN THE DIAMETER OF THE THROUGH PENETRANT (ITEM 2). THE CHASE WALL SHALL INCLUDE THE FOLLOWING
<br />CONSTRUCTION FEATURES:
<br />A.STUDS - NOM 2 BY 4 IN. (51 BY 102 MM), 2 BY 6 IN. (51 BY 152 MM) OR DOUBLE NOM 2 BY 4 IN. (51 BY 102 MM) LUMBER STUDS.
<br />B.SOLE PLATE - NOM 2 BY 4 IN. (51 BY 102 MM), 2 BY 6 IN. (51 BY 152 MM) OR PARALLEL 2 BY 4 IN. (51 BY 102 MM) LUMBER
<br />PLATES, TIGHTLY BUTTED. DIAM OF OPENING IS TO BE MAX 1 IN. (25 MM) LARGER THAN DIAM OF PIPE. AS AN ALTERNATE,
<br />THE OPENING MAY BE SQUARE-CUT WITH A MAX DIMENSION 1 IN. (25 MM) GREATER THAN THE DIAM OF THE PIPE. PLATES
<br />MAY BE DISCONTINUOUS OVER OPENING, TERMINATING AT TWO OPPOSING EDGES OF OPENING. MAX LENGTH OF
<br />DISCONTINUITY IS 5-1/2 IN. (140 MM).
<br />C.TOP PLATE - THE SINGLE OR DOUBLE TOP PLATE SHALL CONSIST OF TWO NOM 2 BY 4 IN. (51 BY 102 MM), OR ONE OR TWO
<br />NOM 2 BY 6 IN. (51 BY 152 MM), OR ONE OR TWO SETS OF PARALLEL 2 BY 4 IN. (51 BY 102 MM), LUMBER PLATES, TIGHTLY
<br />BUTTED. DIAM OF OPENING IS TO BE MAX 1 IN. (25 MM) LARGER THAN DIAM OF PIPE. AS AN ALTERNATE, THE OPENING MAY
<br />BE SQUARE-CUT WITH A MAX DIMENSION 1 IN. (25 MM) GREATER THAN THE DIAM OF THE PIPE. PLATES MAY BE
<br />DISCONTINUOUS OVER OPENING, TERMINATING AT TWO OPPOSING EDGES OF OPENING. MAX LENGTH OF DISCONTINUITY IS
<br />5-1/2 IN. (140 MM).
<br />D.STEEL PLATE - WHEN LUMBER PLATES ARE DISCONTINUOUS, NOM 1-1/2 IN. (38 MM) WIDE NO. 20 GAUGE (OR HEAVIER) GALV
<br />STEEL PLATES SHALL BE INSTALLED TO CONNECT DISCONTINUOUS LUMBER PLATES AND TO PROVIDE A FORM FOR THE FILL
<br />MATERIAL. STEEL PLATES SIZED TO LAP 2 IN. (51 MM) ONTO EACH DISCONTINUOUS LUMBER PLATE AND SECURED TO
<br />LUMBER PLATES WITH STEEL SCREWS OR NAILS.
<br />E.GYPSUM BOARD* - MIN. 1./2 IN. THICK RATED OR NON-RATED GYPSUM BOARD.
<br />2.THROUGH PENETRANT - ONE METALLIC PIPE, CONDUIT OR TUBING TO BE INSTALLED EITHER CONCENTRICALLY OR
<br />ECCENTRICALLY WITHIN THE OPENING. ANNULAR SPACE TO BE MIN 0 IN. (POINT CONTACT) TO MAX 1 IN. (0 TO 25 MM).
<br />PENETRANT TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF FLOOR-CEILING ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF
<br />METALLIC PIPE, CONDUIT OR TUBING MAY BE USED:
<br />A.STEEL PIPE - NOM 4 IN. (102 MM) DIAM (OR SMALLER) SCHEDULE 5 (OR HEAVIER) STEEL PIPE.
<br />B.IRON PIPE - NOM 4 IN. (102 MM) DIAM (OR SMALLER) CAST OR DUCTILE IRON PIPE.
<br />C.CONDUIT - NOM 4 IN. (102 MM) DIAM (OR SMALLER) STEEL CONDUIT, STEEL ELECTRICAL METALLIC TUBING OR FLEXIBLE
<br />STEEL CONDUIT.
<br />D.COPPER PIPE OR TUBE - NOM 4 IN. (102 MM) DIAM (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE OR TYPE L (OR
<br />HEAVIER) COPPER TUBE.
<br />THE T, FT AND FTH RATINGS ARE 1/4 HR WHEN COPPER PIPE OR TUBE IS USED IN 1 HR FIRE-RATED ASSEMBLIES. THE T, FT
<br />AND FTH RATINGS ARE 1/2 HR WHEN COPPER PIPE OR TUBE IS USED IN 2 HR FIRE-RATED ASSEMBLIES. WHEN STEEL PIPE,
<br />IRON PIPE, STEEL CONDUIT OR FLEXIBLE METAL PIPING (ITEM 2A) IS USED, T, FT AND FTH RATINGS ARE 1 HR.
<br />2A. THROUGH PENETRATING PRODUCT* - FLEXIBLE METAL PIPING - AS AN ALTERNATE TO ITEM 2, ONE NOM 2 IN. (51 MM) DIAM (OR
<br />SMALLER) STEEL FLEXIBLE METAL PIPE TO BE INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP
<br />SYSTEM. ANNULAR SPACE TO BE MIN 0 IN. (POINT CONTACT) TO MAX 1 IN. (0 TO 25 MM). PENETRANT TO BE RIGIDLY SUPPORTED
<br />ON BOTH SIDES OF FLOOR-CEILING ASSEMBLY.
<br />OMEGA FLEX INC
<br />GASTITE, DIV OF TITEFLEX
<br />WARD MFG L L C
<br />3.FILL, VOID OR CAVITY MATERIAL* - SEALANT - MIN 3/4 IN. (19 MM) THICKNESS OF FILL MATERIAL APPLIED WITHIN THE ANNULUS,
<br />FLUSH WITH THE TOP SURFACE OF THE FLOOR OR SOLE PLATE. MIN 5/8 IN. (16 MM) THICKNESS OF FILL MATERIAL APPLIED
<br />WITHIN THE ANNULUS, FLUSH WITH BOTTOM SURFACE OF CEILING OR TOP PLATE. MIN 1/4 IN. (6 MM) DIAM BEAD OF FILL
<br />MATERIAL APPLIED AT POINT CONTACT LOCATION ON THE TOP SURFACE OF FLOOR OR SOLE PLATE AND AT THE
<br />PENETRANT/CEILING OR TOP PLATE INTERFACE.
<br />SPECIFIED TECHNOLOGIES INC - SPECSEAL LCI SEALANT OR TYPE WF300 FIRESTOP CAULK
<br />*INDICATES SUCH PRODUCTS SHALL BEAR THE UL OR CUL CERTIFICATION MARK FOR JURISDICTIONS EMPLOYING THE UL OR
<br />CUL CERTIFICATION (SUCH AS CANADA), RESPECTIVELY.
<br />PIPE, CONDUIT, OR TUBING
<br />02_H_BB_ULFC1074 _SINGLE METALLIC 4" OR SCALE: 1 1/2" = 1'-0"
<br />FIRE RESISTANCE LISTING:
<br />U.L. DESIGN NO.
<br />F-C-1074
<br />FIRE RATING:
<br />1-2HR
<br />FLEX PIPE_1-2HR
<br />System No. F-C-1074
<br />ANSI/UL1479 (ASTM E814)
<br />F Ratings - 1 Hr and 2 Hr (See Item 1)
<br />T Ratings - 1/4, 1/2 and 1 Hr (See Item 2)
<br />L Rating At Ambient - Less Than 1 CFM/sq ft
<br />L Rating At 400 F - Less Than 1 CFM/sq ft
<br />CAN/ULC S115
<br />F Ratings - 1 Hr and 2 Hr (See Item 1)
<br />FT Ratings - 1/4, 1/2 and 1 Hr (See Item 2)
<br />FH Ratings - 1 Hr and 2 Hr (See Item 1)
<br />FTH Ratings - 1/4, 1/2 and 1 Hr (See Item 2)
<br />L Rating At Ambient - Less Than 5.1 L/s/m2
<br />L Rating At 400 F - Less Than 5.1 L/s/m2
<br />DRAIN PIPE
<br />02_H_BB_ULFC7060_STEEL DUCT 6" OR SMALLER SCALE: 1 1/2" = 1'-0"
<br />FIRE RESISTANCE LISTING:
<br />U.L. DESIGN NO.
<br />F-C-2156
<br />FIRE RATING:
<br />1 HR
<br />SYSTEM NO. F-C-2156
<br />F RATING - 1 HR
<br />T RATING - 1 HR
<br />1.FLOOR-CEILING ASSEMBLY - THE 1 HR FIRE-RATED SOLID OR TRUSSED LUMBER JOIST FLOOR-CEILING ASSEMBLY SHALL BE
<br />CONSTRUCTED OF THE MATERIALS AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL L500 SERIES FLOOR-CEILING DESIGNS
<br />IN THE UL FIRE RESISTANCE DIRECTORY. THE GENERAL CONSTRUCTION FEATURES OF THE FLOOR-CEILING ASSEMBLY ARE
<br />SUMMARIZED BELOW:
<br />A.FLOORING SYSTEM - LUMBER OR PLYWOOD SUBFLOOR WITH FINISH FLOOR OF LUMBER, PLYWOOD OR FLOOR
<br />TOPPING MIXTURE* AS SPECIFIED IN THE INDIVIDUAL FLOOR-CEILING DESIGN. RECTANGULAR CUTOUT IN FLOORING TO
<br />ACCOMODATE THE BATHTUB DRAIN PIPING (ITEM 2) TO BE MAX 8 IN. BY 12 IN. CUTOUT TO BE PATCHED ON UNDERSIDE OF
<br />SUBFLOOR USING ONE LAYER OF MIN 3/4 IN. THICK PLYWOOD OR MIN 5/8 IN. THICK GYPSUM WALLBOARD (ITEM 1C) SIZED
<br />TO LAP MIN 2 IN. BEYOND EACH EDGE OF RECTANGULAR CUTOUT. DIAM OF OPENING HOLE-SAWED THROUGH PATCH TO
<br />ACCOMODATE DRAIN PIPING (ITEM 2) TO BE 1 IN. LARGER THAN OUTSIDE DIAM OF DRAIN PIPING AND POSITIONED SUCH
<br />THAT DRAIN PIPING IS CENTERED IN OPENING. PATCH SPLIT INTO TWO PIECES AT OPENING HOLE-SAWED FOR BATHTUB
<br />DRAIN PIPING. TWO PIECES POSITIONED AROUND DRAIN PIPING, WITH CUT EDGES TIGHTLY BUTTED, AND
<br />SCREW-ATTACHED TO UNDERSIDE OF SUBFLOOR WITH 1-1/4 IN. LONG TYPE S STEEL SCREWS SPACED MAX 6 IN. OC.
<br />B.WOOD JOISTS* - NOM 10 IN. DEEP (OR DEEPER) LUMBER, STEEL OR COMBINATION LUMBER AND STEEL JOISTS,
<br />TRUSSES OR STRUCTURAL WOOD MEMBERS* WITH BRIDGING AS REQUIRED AND WITH ENDS FIRESTOPPED.
<br />C.GYPSUM BOARD* - NOM 4 FT. WIDE BY 5/8 IN. THICK, ATTACHED AS DESCRIBED IN THE INDIVIDUAL FLOOR-CEILING
<br />DESIGN.
<br />2.DRAIN PIPING - NOM 1-1/2 IN. DIAM (OR SMALLER) SCHEDULE 40 CELLULAR OR SOLID CORE POLYVINYL CHLORIDE (PVC)
<br />ACRYLONITRILE BUTADIENE STYRENE (ABS), OR SDR17 CHLORINATED POLYVINYL CHLORIDE (CPVC) PIPE AND DRAIN FITTINGS
<br />CEMENTED TOGETHER AND PROVIDED WITH PVC, ABS OR CPVC BATHTUB WASTE/OVERFLOW FITTINGS. THE ANNULAR SPACE
<br />SHALL BE A MIN 3/8 IN. TO MAX 5/8 IN.
<br />3.FILL, VOID OR CAVITY MATERIAL* - SEALANT - MIN 5/8 IN. DEPTH OF FILL MATERIAL APPLIED WITHIN ANNULAR SPACE,
<br />FLUSH WITH BOTH SURFACES OF PLYWOOD OR GYPSUM WALLBOARD PATCH.
<br />SPECIFIED TECHNOLOGIES INC - SPECSEAL SERIES SSS SEALANT OR SPECSEAL LCI SEALANT
<br />* BEARING THE UL CLASSIFICATION MARK
<br />1C
<br />1A 3
<br />1B
<br />2
<br />1
<br />37111519
<br />1721
<br />23
<br />13 9 5STEEL DUCT
<br />02_H_BB_ULCAJ7040_STEEL DUCT_2HR_Concrete SCALE: N.T.S.
<br />FIRE RESISTANCE LISTING:
<br />U.L. DESIGN NO.
<br />C-AJ-7040
<br />FIRE RATING:
<br />2-HR
<br />SYSTEM NO. C-AJ-7040
<br />F RATING - 2 HR
<br />T RATING - 1/4 HR
<br />1. FLOOR ASSEMBLY - MIN 4-1/2 IN. (114 MM) THICK REINFORCED LIGHTWEIGHT OR NORMAL WEIGHT (100-150 PCF OR 1600-2400 KG/M3)
<br />CONCRETE FLOOR. FLOOR MAY ALSO BE CONSTRUCTED OF ANY MIN 6 IN. (152 MM) THICK HOLLOW-CORE PRECAST CONCRETE UNITS*. WALL
<br />MAY ALSO BE CONSTRUCTED OF ANY UL CLASSIFIED CONCRETE BLOCKS*. MAX DIAM OF OPENING IS 10 IN. (254 MM). MAX DIAM OF OPENING IN
<br />FLOORS CONSTRUCTED OF HOLLOW-CORE CONCRETE IS 7 IN. (178 MM).
<br />SEE CONCRETE BLOCKS (CAZT) OR PRECAST CONCRETE UNITS (CFTV) CATEGORIES IN THE FIRE RESISTANCE DIRECTORY FOR NAMES OF
<br />MANUFACTURERS.
<br />2. STEEL SLEEVE - (OPTIONAL) - NOM 14 IN. (356 MM) DIAM (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL PIPE CAST OR GROUTED INTO FLOOR
<br />OR WALL ASSEMBLY. STEEL SLEEVE MAY BE INSTALLED FLUSH OR MAY PROJECT A MAX OF 2 IN. (51 MM) BEYOND THE FLOOR OR WALL
<br />SURFACES.
<br />3. STEEL DUCT - ONE NOM 12 IN. (305 MM) DIAM (OR SMALLER) GALV STEEL DUCT. STEEL GAUGE OF DUCT SHALL CONFORM WITH SMACNA
<br />REQUIREMENTS. STEEL DUCT TO BE INSTALLED ECCENTRICALLY OR CONCENTRICALLY WITHIN THE FIRESTOP SYSTEM. THE ANNULAR SPACE
<br />BETWEEN THE STEEL DUCT AND THE PERIPHERY OF THE OPENING SHALL BE MIN 0 IN. (POINT CONTACT) TO MAX 2 IN. (51 MM). STEEL DUCT TO
<br />BE RIGIDLY SUPPORTED ON BOTH SIDES OF THE FLOOR OR WALL ASSEMBLY.
<br />4. FIRESTOP SYSTEM - THE FIRESTOP SYSTEM SHALL CONSIST OF THE FOLLOWING:
<br />A. PACKING MATERIAL - MIN 3 IN. (76 MM) THICKNESS OF MIN 4 PCF (64 KG/M3) MINERAL WOOL BATT INSULATION COMPRESSED AND TIGHTLY
<br />PACKED INTO OPENING. PACKING MATERIAL RECESSED FROM TOP SURFACE OF FLOOR OR BOTH SURFACES OF WALL OR PRECAST
<br />CONCRETE UNITS TO ACCOMMODATE THE REQUIRED THICKNESS OF FILL MATERIAL. WHEN STEEL SLEEVE PROJECTS FROM TOP OF FLOOR
<br />OR FROM BOTH SIDES OF WALL, THE THICKNESS OF MINERAL WOOL BATT PACKING MATERIAL SHOULD BE INCREASED BY AN AMOUNT
<br />EQUAL TO THE DISTANCE THAT THE SLEEVE EXTENDS PAST THE FLOOR OR WALL SURFACE.
<br />B. FILL, VOID OR CAVITY MATERIAL* - SEALANT - MIN 1/2 IN. (13 MM) THICKNESS OF FILL MATERIAL APPLIED WITHIN ANNULUS, FLUSH WITH TOP
<br />SURFACE OF FLOOR ASSEMBLY OR TOP EDGE OF STEEL SLEEVE. IN WALLS, MIN 1/2 IN. (13 MM) THICKNESS OF FILL MATERIAL APPLIED
<br />FLUSH WITH BOTH SURFACES OF WALL ASSEMBLY OR BOTH ENDS OF STEEL SLEEVE. IN FLOORS CONSTRUCTED OF HOLLOW-CORE
<br />PRECAST CONCRETE UNITS, FILL MATERIAL INSTALLED SYMMETRICALLY ON BOTH SIDES OF FLOOR. AT POINT CONTACT LOCATION, MIN 1/4
<br />IN. (6 MM) DIAM BEAD OF FILL MATERIAL INSTALLED AT STEEL DUCT/CONCRETE OR STEEL DUCT/STEEL SLEEVE INTERFACE ON TOP
<br />SURFACE OF FLOOR OR BOTH SURFACES OF WALL OR PRECAST CONCRETE UNITS.
<br />SPECIFIED TECHNOLOGIES INC - SPECSEAL LCI SEALANT
<br />*INDICATES SUCH PRODUCTS SHALL BEAR THE UL OR CUL CERTIFICATION MARK FOR JURISDICTIONS EMPLOYING THE UL OR CUL
<br />CERTIFICATION (SUCH AS CANADA), RESPECTIVELY.
<br />3
<br />4B 12
<br />4A
<br />3
<br />2 4A
<br />4B
<br />STEEL DUCT
<br />02_H_BB_ULCAJ7041_STEEL DUCT_2HR_Concrete SCALE: N.T.S.
<br />FIRE RESISTANCE LISTING:
<br />U.L. DESIGN NO.
<br />C-AJ-7041
<br />FIRE RATING:
<br />2-HR
<br />2
<br />3C
<br />3B 1
<br />3A
<br />2
<br />3C
<br />3A
<br />3B
<br />SYSTEM NO. C-AJ-7041
<br />F RATING - 2 HR
<br />T RATING - 0 HR
<br />L RATING AT AMBIENT - LESS THAN 1 CFM/SQ FT.
<br />L RATING AT 400 F - LESS THAN 1 CFM/SQ FT.
<br />1. FLOOR OR WALL ASSEMBLY - MIN 4-1/2 IN. (114 MM) THICK REINFORCED LIGHTWEIGHT OR NORMAL WEIGHT (100-150 PCF OR
<br />1600-2400 KG/M3) CONCRETE FLOOR. WHEN LC150 OR LE600 SEALANT (ITEM 3B) IS USED, THE MIN WALL THICKNESS IS 5 IN. (127
<br />MM). WALL MAY ALSO BE CONSTRUCTED OF ANY UL CLASSIFIED CONCRETE BLOCKS* MAX AREA OF OPENING IS 1024 SQ IN. (0.66
<br />M3) WITH A MAX DIMENSION OF 32 IN. (81 CM).
<br />SEE CONCRETE BLOCKS (CAZT) CATEGORY IN THE FIRE RESISTANCE DIRECTORY FOR NAMES OF MANUFACTURERS.
<br />2. STEEL DUCT - NOM 30 BY 30 IN. (76 BY 76 CM) (OR SMALLER) NO. 24 GA (OR HEAVIER) GALV STEEL DUCT INSTALLED
<br />ECCENTRICALLY OR CONCENTRICALLY WITHIN OPENING. STEEL GAUGE OF DUCT SHALL CONFORM WITH SMACNA
<br />REQUIREMENTS. ANNULAR SPACE BETWEEN DUCT AND PERIPHERY OF OPENING TO BE MIN 1/4 IN. TO MAX 1-3/4 IN. DUCT TO BE
<br />RIGIDLY SUPPORTED ON BOTH SIDES OF THE FLOOR OR WALL ASSEMBLY.
<br />3. FIRESTOP SYSTEM - THE FIRESTOP SYSTEM SHALL CONSIST OF THE FOLLOWING:
<br />A. PACKING MATERIAL - MIN 4 PCF (64 KG/M3) MINERAL WOOL BATT INSULATION COMPRESSED AND TIGHTLY PACKED TO MIN 3
<br />IN. (76 MM) THICKNESS. PACKING MATERIAL RECESSED FROM TOP SURFACE OF FLOOR OR BOTH SURFACES OF WALL AS
<br />REQUIRED TO ACCOMMODATE FILL MATERIAL (ITEM 3B).
<br />B. FILL VOID OR CAVITY MATERIALS* - SEALANT - MIN 1/2 IN. (13 MM) THICKNESS OF FILL MATERIAL APPLIED WITHIN THE
<br />ANNULUS, FLUSH WITH TOP SURFACE OF FLOOR ASSEMBLY OR BOTH SURFACES OF WALL ASSEMBLY. WHEN LC150 OR LE600
<br />SEALANT IS USED, THE MIN SEALANT THICKNESS IS 1 IN. (25 MM).
<br />SPECIFIED TECHNOLOGIES INC - SPECSEAL LCI SEALANT, SPECSEAL LC150 SEALANT, OR SPECSEAL LE600 SEALANT.
<br />C. RETAINING ANGLES - MIN 16 GA (0.059 IN. OR 1.5 MM) GALV STEEL ANGLES SIZED TO LAP DUCT A MIN OF 2 IN. (51 MM) AND LAP
<br />PERIPHERY OF OPENING A MIN OF 1 IN. (25 MM). ANGLES ATTACHED TO ALL FOUR SIDES OF STEEL DUCT ON TOP SURFACE OF
<br />FLOOR OR BOTH SURFACES OF WALL WITH NO. 10 (OR LARGER) STEEL SHEET METAL SCREWS SPACED 1 IN. (25 MM) FROM
<br />EACH END AND MAX 4 IN. (102 MM) OC.
<br />*INDICATES SUCH PRODUCTS SHALL BEAR THE UL OR CUL CERTIFICATION MARK FOR JURISDICTIONS EMPLOYING THE UL OR
<br />CUL CERTIFICATION (SUCH AS CANADA), RESPECTIVELY.
<br />1
<br />1
<br />HOLD- 829 N
<br />Garfield St1/15/2025
|