Laserfiche WebLink
CCOPYRIGHT <br />It is the clients responsibility prior to or during construction to notify the architect in writing <br />of any perceived errors or omissions in the plans and specifications of which a contractor <br />thoroughly knowledgeable with the building codes and methods of construction should <br />reasonably be aware. Written instructions addressing such perceived errors or omissions <br />shall be received from the architect prior to the client or clients subcontractors proceeding <br />with the work. The client will be responsible for any defects in construction if these <br />procedures are not followed. <br />Zohrabians Art of Design <br />700 Palm Drive, Suite 106 <br />Glendale, CA 91202 <br />zartofdesign.com <br />818.300.9420 <br />2n <br />d <br /> <br />P <br />l <br />a <br />n <br /> <br />C <br />h <br />e <br />c <br />k <br /> <br />S <br />u <br />b <br />m <br />i <br />t <br />t <br />a <br />l <br />No.Date Description <br />06/05/2024 100% DD SET <br />06/14/2024 50% CD PROGRESS SET <br />06/21/2024 75% CD PROGRESS SET <br />07/02/2024 NEIGHBORHOOD REVIEW <br />07/10/2024 1ST PLAN CHECK SUBMITTAL <br />09/13/2024 2ND PLAN CHECK SUBMITTAL <br />82 <br />9 <br /> <br />N <br />. <br /> <br />G <br />A <br />R <br />F <br />I <br />E <br />L <br />D <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />Santa Ana, CA 92701 <br />829 N. Garfield Street <br />Name: <br />Project Contact: <br />Phone: <br />Email: <br /> <br />Principal: <br />Z.AOD Project No:2024-02 <br />Arthur Zohrabians <br />818.300.9420 <br />Arthur Zohrabians <br />info@zartofdesign.com <br />Phone No.:949.922.7075 <br />Email:vanitapuri@gmail.com <br />Owner <br />GA <br />R <br />F <br />I <br />E <br />L <br />D <br /> <br />R <br />E <br />S <br />T <br />O <br />R <br />A <br />T <br />I <br />O <br />N <br /> <br />/ <br /> <br />R <br />E <br />M <br />O <br />D <br />E <br />L <br />Address: <br />Ren.11/30/25 <br />A <br />No. C37490 <br />A <br />A FOILOFC <br />R <br />INTA <br />S <br />ET <br />TC <br />A RCHITE <br />DESNECIL <br />RTHUR <br />HAMAYAK ZOHRABI <br />A <br />SN <br />VVS Estates, LLC <br />1 <br />Vanita Soni PuriAttn: <br />FIRE-RESISTANCE <br />RATED PENETRATION <br />DETAILS <br />A903 <br />STEEL DUCT <br />02_H_BB_ULFC7060_STEEL DUCT 6" OR SMALLER SCALE: 1 1/2" = 1'-0" <br />FIRE RESISTANCE LISTING: <br />U.L. DESIGN NO. <br />F-C-7060 <br />FIRE RATING: <br />1 HR <br />1.FLOOR - CEILING ASSEMBLY - THE 1 HR FIRE-RATED WOOD JOIST FLOOR-CEILING ASSEMBLY SHALL BE CONSTRUCTED OF <br />THE MATERIALS AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL L500 DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY, <br />AS SUMMARIZED BELOW: <br />A.FLOORING SYSTEM - LUMBER OR PLYWOOD SUBFLOOR WITH FINISH FLOOR OF LUMBER, PLYWOOD OR FLOOR TOPPING <br />MIXTURE* AS SPECIFIED IN THE INDIVIDUAL FLOOR-CEILING DESIGN. <br />B.WOOD JOISTS - NOM 10 IN. (254 MM) DEEP (OR DEEPER) LUMBER, STEEL OR COMBINATION LUMBER AND STEEL JOISTS, <br />TRUSSES OR STRUCTURAL WOOD MEMBERS* WITH BRIDGING AS REQUIRED AND WITH ENDS FIRESTOPPED. <br />C.GYPSUM BOARD* - THICKNESS, TYPE, NUMBER OF LAYERS AND FASTENERS AS REQUIRED IN THE INDIVIDUAL <br />FLOOR-CEILING DESIGN. DIAM OF OPENING IS TO BE MAX 1-1/2 IN. (38 MM) LARGER THAN DIAM OF STEEL DUCT. <br />1A. CHASE WALL - (OPTIONAL, NOT SHOWN) - THE THROUGH PENETRANT (ITEM 2) MAY BE ROUTED THROUGH A 1 HR FIRE RATED <br />SINGLE, DOUBLE OR STAGGERED WOOD STUD/GYPSUM BOARD CHASE WALL. DEPTH OF CHASE WALL STUD CAVITY TO BE <br />MIN 1/2 IN. (13 MM) GREATER THAN DIAMETER OF OPENING CUT IN TOP PLATES TO ACCOMMODATE THE THROUGH <br />PENETRANT (ITEM 2). THE CHASE WALL SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER SPECIFIED IN THE <br />INDIVIDUAL U300 SERIES WALL AND PARTITION DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE <br />FOLLOWING CONSTRUCTION FEATURES: <br />A.STUDS - NOM 2 BY 4 IN. (51 BY 102 MM), 2 BY 6 IN. (51 BY 152 MM) OR DOUBLE NOM 2 BY 4 IN. (51 BY 102 MM) LUMBER STUDS. <br />B.SOLE PLATE - NOM 2 BY 4 IN. (51 BY 102 MM), 2 BY 6 IN. (51 BY 152 MM)OR PARALLEL 2 BY 4 IN. (51 BY 102 MM) LUMBER <br />PLATES, TIGHTLY BUTTED. <br />C.TOP PLATE - THE DOUBLE TOP PLATE SHALL CONSIST OF TWO NOM 2 BY 4 IN (51 BY 102 MM)., TWO NOM 2 BY 6 IN. (51 BY <br />152 MM) OR TWO SETS OF PARALLEL 2 BY 4 IN. (51 BY 102 MM) LUMBER PLATES, TIGHTLY BUTTED. DIAM OF OPENING IS TO <br />BE MAX 1-1/2 IN. (38 MM) LARGER THAN DIAM OF STEEL DUCT. AS AN ALTERNATE, THE OPENING MAY BE SQUARE-CUT WITH <br />A MAX DIMENSION 1-1/2 IN. (38 MM) GREATER THAN THE DIAM OF THE PIPE. PLATES MAY BE DISCONTINUOUS OVER <br />OPENING, TERMINATING AT TWO OPPOSING EDGES OF OPENING. MAX LENGTH OF DISCONTINUITY IS 7-1/2 IN. (191 MM). <br />D.STEEL PLATE - WHEN LUMBER PLATES ARE DISCONTINUOUS, NOM 1-1/2 IN. (38 MM) WIDE NO. 20 GAUGE (OR HEAVIER) <br />GALV STEEL PLATES SHALL BE INSTALLED TO CONNECT DISCONTINUOUS LUMBER PLATES AND TO PROVIDE A FORM FOR <br />THE FILL MATERIAL. STEEL PLATES SIZED TO LAP 2 IN. (51 MM) ONTO EACH DISCONTINUOUS LUMBER PLATE AND SECURED <br />TO LUMBER PLATES WITH STEEL SCREWS OR NAILS. <br />E.GYPSUM BOARD* - THICKNESS, TYPE, NUMBER OF LAYERS AND FASTENERS SHALL BE AS SPECIFIED IN THE INDIVIDUAL <br />WALL AND PARTITION DESIGN. <br />2.STEEL DUCT - ONE NOM 6 IN. (152 MM) DIAM (OR SMALLER) NO. 30 GA (OR HEAVIER) GALVANIZED STEEL DUCT TO BE <br />INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE OPENING. ANNULAR SPACE TO BE MIN 0 IN. (POINT <br />CONTACT) TO MAX 1-1/2 IN. (38 MM). STEEL DUCT TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF FLOOR-CEILING ASSEMBLY. <br />3.FILL, VOID OR CAVITY MATERIAL* - SEALANT - MIN 5/8 IN. (16 MM) THICKNESS OF FILL MATERIAL APPLIED WITHIN THE <br />ANNULUS, FLUSH WITH BOTTOM SURFACE OF CEILING OR TOP PLATE. MIN 1/4 IN. (6 MM) DIAM BEAD OF FILL MATERIAL <br />APPLIED AT POINT CONTACT LOCATION AT THE PENETRANT/CEILING OR CHASE WALL TOP PLATE INTERFACE. <br />SPECIFIED TECHNOLOGIES INC - SPECSEAL LCI SEALANT, SPECSEAL LC150 SEALANT OR TYPE WF300 CAULK <br />*INDICATES SUCH PRODUCTS SHALL BEAR THE UL OR CUL CERTIFICATION MARK FOR JURISDICTIONS EMPLOYING THE UL <br />OR CUL CERTIFICATION (SUCH AS CANADA), RESPECTIVELY. <br />System No. F-C-7060 <br />ANSI/UL1479 (ASTM E814) <br />F Rating - 1 Hr <br />T Ratings - 1 Hr <br />L Rating At Ambient - Less Than 1 CFM/sq ft <br />CAN/ULC S115 <br />F Rating - 1 Hr <br />FT Ratings - 1 Hr <br />FH Rating - 1 Hr <br />FTH Ratings - 1 Hr <br />L Rating At Ambient - Less Than 1 CFM/sq ft <br />1B <br />3 <br />1A <br />1C <br />2 <br />SYSTEM NO. W-L-2241 <br />F RATINGS - 1 AND 2 HR (SEE ITEM 1) <br />T RATINGS - 0, 1/4, 1 AND 1-3/4 HR (SEE ITEM 2) <br />L RATING AT AMBIENT - LESS THAN 1 CFM/SQ FT <br />L RATING AT 400 F - LESS THAN 1 CFM/SQ FT <br />1.WALL ASSEMBLY - THE 1 OR 2 HR FIRE-RATED GYPSUM BOARD/STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE <br />MATERIALS AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL U300 OR U400 SERIES WALL OR PARTITION DESIGN IN THE UL FIRE <br />RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES: <br />A.STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF <br />NOM 2 BY 4 IN. (51 BY 102 MM) LUMBER SPACED MAX 16 IN. (406 MM) OC. STEEL STUDS TO BE MIN 3-1/2 IN. (89 MM) WIDE AND <br />SPACED MAX 24 IN. (610 MM) OC. <br />B.GYPSUM BOARD* - THICKNESS, TYPE, NUMBER OF LAYERS AND FASTENERS AS SPECIFIED IN THE INDIVIDUAL WALL AND <br />PARTITION DESIGN. DIAM OF OPENING TO BE 1 IN. TO 1-1/8 IN. (25 TO 29 MM) LARGER THAN OUTSIDE DIAM OF PIPE. <br />THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS EQUAL TO THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN <br />WHICH IT IS INSTALLED. WHEN ITEM 2G OR 2H IS USED, THE HOURLY F RATING IS 1 HR. <br />2.THROUGH PENETRANT - ONE NONMETALLIC PIPE, CONDUIT OR TUBE TO BE INSTALLED ECCENTRICALLY OR CONCENTRICALLY <br />WITHIN THE FIRESTOP SYSTEM. PIPE, CONDUIT OR TUBE TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF THE WALL ASSEMBLY. <br />THE FOLLOWING TYPES AND SIZES OF NONMETALLIC PIPES, CONDUITS AND TUBES MAY BE USED: <br />A.POLYVINYL CHLORIDE (PVC) PIPE - NOM 2 IN. (51 MM) DIAM (OR SMALLER) SCHEDULE 40 SOLID OR CELLULAR CORE PVC PIPE <br />FOR USE IN CLOSED (PROCESS OR SUPPLY) OR VENTED (DRAIN, WASTE OR VENT) PIPING SYSTEMS. ANNULAR SPACE SHALL <br />BE MIN 0 IN. ( 0 MM, POINT CONTACT) TO MAX 1 IN. (25 MM). <br />B.CHLORINATED POLYVINYL CHLORIDE (CPVC) PIPE - NOM 2 IN. (51 MM) DIAM (OR SMALLER) SDR 13.5 OR SCHEDULE 80 CPVC <br />PIPE FOR USE IN CLOSED (PROCESS OR SUPPLY) PIPING SYSTEMS. ANNULAR SPACE SHALL BE MIN 0 IN. ( 0 MM, POINT <br />CONTACT) TO MAX 1 IN. (25 MM). <br />C.RIGID NONMETALLIC CONDUIT+ - NOM 2 IN. (51 MM) DIAM (OR SMALLER) SCHEDULE 40 PVC CONDUIT INSTALLED IN <br />ACCORDANCE WITH ARTICLE 347 OF THE NATIONAL ELECTRICAL CODE (NFPA 70). ANNULAR SPACE SHALL BE MIN 0 IN. ( 0 MM, <br />POINT CONTACT) TO MAX 1 IN. (25 MM). <br />D.ELECTRICAL NONMETALLIC TUBING+ - NOM 2 IN. (51 MM) DIAM (OR SMALLER) PVC TUBING INSTALLED IN ACCORDANCE WITH <br />ARTICLE 331 OF THE NATIONAL ELECTRICAL CODE (NFPA 70). ANNULAR SPACE SHALL BE MIN 0 IN. ( 0 MM, POINT CONTACT) TO <br />MAX 1 IN. (25 MM). <br />E.CROSS LINKED POLYETHYLENE (PEX) TUBING - NOM 1 IN. (25 MM) DIAM (OR SMALLER) SDR9 PEX TUBING FOR USE IN CLOSED <br />(PROCESS OR SUPPLY) PIPING SYSTEMS. ANNULAR SPACE SHALL BE MIN 0 IN. ( 0 MM, POINT CONTACT) TO MAX 1 IN. (25 MM). <br />F.ACRYLONITRILE BUTADIENE STYRENE (ABS) PIPE - NOM 1-1/2 IN. (38 MM) DIAM (OR SMALLER) SCHEDULE 40 SOLID-CORE OR <br />CELLULAR CORE ABS PIPE FOR USE IN CLOSED (PROCESS OR SUPPLY) OR VENTED (DRAIN, WASTE OR VENT) PIPING <br />SYSTEMS. ANNULAR SPACE SHALL BE MIN 1/4 IN. (6 MM) TO MAX 3/4 IN. (19 MM). <br />G.POLYVINYL CHLORIDE (PVC) PIPE - NOM 3 IN. (76 MM) DIAM (OR SMALLER) SCHEDULE 40 SOLID OR CELLULAR CORE PVC PIPE <br />FOR USE IN CLOSED (PROCESS OR SUPPLY) PIPING SYSTEMS. ANNULAR SPACE SHALL BE MIN 0 IN. (0 MM, POINT CONTACT) <br />TO MAX 1 IN. (25 MM). <br />H.CHLORINATED POLYVINYL CHLORIDE (CPVC) PIPE - NOM 3 IN. (76 MM) DIAM (OR SMALLER) SDR 17 CPVC PIPE FOR USE IN <br />CLOSED (PROCESS OR SUPPLY) PIPING SYSTEMS. ANNULAR SPACE SHALL BE MIN 0 IN. (0 MM, POINT CONTACT) TO MAX 1 IN. <br />(25 MM). <br />WHEN ITEM 2A OR 2B IS USED, THE T RATING IS 1/4 HR. WHEN ITEM 2C, 2D, OR 2E IS USED, THE T RATING IS 1 HR AND 1-3/4 HR <br />FOR 1 HR AND 2 HR FIRE RATED WALLS, RESPECTIVELY. WHEN ITEM 2F, 2G, OR 2H IS USED, T RATING IS 0 HR. <br />3.FILL, VOID OR CAVITY MATERIAL* - SEALANT - MIN 5/8 IN. (16 MM) THICKNESS OF FILL MATERIAL APPLIED WITHIN ANNULUS, <br />FLUSH WITH BOTH SURFACES OF WALL ASSEMBLY. AT POINT CONTACT LOCATION, MIN 1/4 IN. (6 MM) DIAM BEAD OF FILL <br />MATERIAL APPLIED AT NONMETALLIC PIPE/GYPSUM BOARD INTERFACE ON BOTH SURFACES OF WALL. <br />SPECIFIED TECHNOLOGIES INC - SPECSEAL LCI SEALANT OR TYPE WF300 FIRESTOP CAULK (FOR WOOD STUDS ONLY) <br />*INDICATES SUCH PRODUCTS SHALL BEAR THE UL OR CUL CERTIFICATION MARK FOR JURISDICTIONS EMPLOYING THE UL OR <br />CUL CERTIFICATION (SUCH AS CANADA), RESPECTIVELY. <br />ONE NON-METALLIC PIPE <br />02_H_BB_ULWL2241 _ONE NON-METALLIC PIPE_1-2HR SCALE: 1 1/2" = 1'-0" <br />FIRE RESISTANCE LISTING: <br />U.L. DESIGN NO. <br />W-L-2241 <br />FIRE RATING: <br />1-HR or 2-HR <br />SYSTEM NO. W-L-1222 <br />F RATINGS - 1 AND 2 HR (SEE ITEM 1) <br />T RATINGS - 1/4, 3/4 AND 1 HR (SEE ITEM 2) <br />1.WALL ASSEMBLY - THE 1 OR 2 HR FIRE-RATED GYPSUM BOARD/STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE <br />MATERIALS AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL U300 OR U400 SERIES WALL OR PARTITION DESIGN IN THE UL <br />FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES: <br />A.STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF <br />NOM 2 BY 4 IN. (51 BY 102 MM) LUMBER SPACED 16 IN. (406 MM) OC. STEEL STUDS TO BE MIN 3-1/2 IN. (89 MM) WIDE AND <br />SPACED MAX 24 IN. (610 MM) OC. <br />B.GYPSUM BOARD* - THICKNESS, TYPE, NUMBER OF LAYERS AND FASTENERS AS SPECIFIED IN THE INDIVIDUAL WALL AND <br />PARTITION DESIGN. MAX DIAM OF OPENING IS 10-5/8 IN. (270 MM). <br />THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS EQUAL TO THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN <br />WHICH IT IS INSTALLED. <br />2.THROUGH PENETRANT - ONE METALLIC PIPE, CONDUIT OR TUBE TO BE INSTALLED ECCENTRICALLY OR CONCENTRICALLY <br />WITHIN THE FIRESTOP SYSTEM. PIPE, CONDUIT OR TUBING MAY BE INSTALLED AT AN ANGLE NOT GREATER THAN 45 DEGREES <br />FROM PERPENDICULAR. THE ANNULAR SPACE BETWEEN THE PIPE, CONDUIT OR TUBE AND THE PERIPHERY OF THE OPENING <br />SHALL BE MIN 0 IN. (0 MM, POINT CONTACT) TO MAX 2 IN. (51 MM). PIPE, CONDUIT OR TUBE TO BE RIGIDLY SUPPORTED ON BOTH <br />SIDES OF THE WALL ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF METALLIC PIPES, CONDUITS AND TUBES MAY BE USED: <br />A.STEEL PIPE - NOM 8 IN. (203 MM) DIAM (OR SMALLER) SCHEDULE 5 (OR HEAVIER) STEEL PIPE. <br />B.IRON PIPE - NOM 8 IN. (203 MM) DIAM (OR SMALLER) CAST OR DUCTILE IRON PIPE. <br />C.CONDUIT - NOM 6 IN. (152 MM) DIAM (OR SMALLER) RIGID STEEL CONDUIT, NOM 4 IN. (102 MM) DIAM (OR SMALLER) STEEL <br />ELECTRICAL METALLIC TUBING (EMT) OR NOM 4 IN. (102 MM) DIAM (OR SMALLER) FLEXIBLE STEEL CONDUIT. <br />D.COPPER PIPE - NOM 4 IN. (102 MM) DIAM (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE. <br />E.COPPER TUBE - NOM 4 IN. (102 MM) DIAM (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBE. <br />2A. THROUGH PENETRATING PRODUCT* - FLEXIBLE METAL PIPING - AS AN ALTERNATE TO ITEM 2, ONE NOM 1-1/4 IN. (32 MM) DIAM <br />(OR SMALLER) STEEL FLEXIBLE METAL PIPE TO BE INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE <br />FIRESTOP SYSTEM. THE ANNULAR SPACE BETWEEN THE PIPE AND THE PERIPHERY OF THE OPENING SHALL BE MIN 0 IN. (0 MM, <br />POINT CONTACT) TO MAX 2 IN. (51 MM). PIPE TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF THE WALL ASSEMBLY. <br />OMEGA FLEX INC <br />GASTITE, DIV OF TITEFLEX <br />WARD MFG L L C <br />3.FILL, VOID OR CAVITY MATERIAL* - SEALANT - MIN 5/8 IN. (16 MM) THICKNESS OF FILL MATERIAL APPLIED WITHIN ANNULUS, <br />FLUSH WITH BOTH SURFACES OF WALL ASSEMBLY. AT POINT CONTACT LOCATION, MIN 1/4 IN. (6 MM) DIAM BEAD OF FILL <br />MATERIAL APPLIED AT METALLIC PIPE/GYPSUM BOARD INTERFACE ON BOTH SURFACES OF WALL. <br />SPECIFIED TECHNOLOGIES INC - SPECSEAL LCI SEALANT <br />*INDICATES SUCH PRODUCTS SHALL BEAR THE UL OR CUL CERTIFICATION MARK FOR JURISDICTIONS EMPLOYING THE UL OR <br />CUL CERTIFICATION (SUCH AS CANADA), RESPECTIVELY. <br />ONE METALLIC PIPE <br />02_H_BB_ULWL1222_ONE METALLIC PIPE_1-2HR SCALE: 1 1/2" = 1'-0" <br />FIRE RESISTANCE LISTING: <br />U.L. DESIGN NO. <br />W-L-1222 <br />FIRE RATING: <br />1-HR or 2-HR <br />TYPE OF PENETRANT <br />STEEL OR IRON PIPE, STEEL CONDUIT OR EMT <br />T RATING <br />1 HR <br />3/4 HR <br />2 IN. (51 MM) <br />8 IN. (203 MM)STEEL OR IRON PIPE, STEEL CONDUIT OR EMT <br />MAX DIAM <br />4 IN. (102 MM)COPPER PIPE OR TUBE 1/4 HR <br />1A <br />1B <br />2 <br />3 3 <br />SYSTEM NO. W-L-3170 <br />F RATINGS - 1 AND 2 HR (SEE ITEM 1) <br />T RATINGS - 1/4 AND 1 HR (SEE ITEM 3A) <br />1.WALL ASSEMBLY - THE 1 OR 2 HR FIRE-RATED GYPSUM BOARD/STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN <br />THE MANNER SPECIFIED IN THE INDIVIDUAL U300 OR U400 SERIES WALL OR PARTITION DESIGN IN THE UL FIRE RESISTANCE DIRECTORY AND <br />SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES: <br />A.STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN. <br />LUMBER SPACED 16 IN. OC. STEEL STUDS TO BE MIN 3-5/8 IN. WIDE AND SPACED MAX 24 IN. OC. <br />B.GYPSUM BOARD* - THICKNESS, TYPE, NUMBER OF LAYERS AND FASTENERS AS SPECIFIED IN THE INDIVIDUAL WALL AND PARTITION <br />DESIGN. MAX DIAM OF OPENING IS 6 IN. <br />THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS EQUAL TO THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS <br />INSTALLED. <br />2.STEEL SLEEVE - CYLINDRICAL SLEEVE FABRICATED FROM 0.0125 IN. THICK (30 GAUGE) GALV SHEET STEEL AND HAVING A MIN 2 IN. LAP <br />ALONG THE LONGITUDINAL SEAM. LENGTH OF THE SLEEVE TO BE EQUAL TO OR MAX 2 IN. GREATER THAN THE THICKNESS OF THE WALL. <br />SLEEVE INSTALLED BY COILING THE SHEET STEEL TO A DIAM SMALLER THAN THE THROUGH OPENING, INSERTING THE COIL THROUGH THE <br />OPENING AND RELEASING THE COIL TO LET IT UNCOIL AGAINST THE CIRCULAR CUTOUTS IN THE GYPSUM WALLBOARD LAYERS. THE ENDS OF <br />THE STEEL SLEEVE SHALL BE FLUSH WITH OR EXTEND A MAX 1 IN. BEYOND EACH SURFACE OF THE WALL. <br />AS AN ALTERNATE, STEEL SLEEVE MAY CONSIST OF NOM 6 IN. DIAM (OR SMALLER) SCHEDULE 5 (OR HEAVIER) STEEL PIPE SLEEVE <br />FRICTION-FITTED INTO CIRCULAR CUTOUTS IN THE GYPSUM BOARD LAYERS. THE ENDS OF THE STEEL SLEEVE SHALL BE FLUSH WITH OR <br />EXTEND A MAX 1 IN. BEYOND EACH SURFACE OF THE WALL. <br />3.CABLES - MAX 4-1/2 IN. DIAM TIGHT BUNDLE OF CABLES TO BE INSTALLED ECCENTRICALLY OR CONCENTRICALLY WITHIN THE OPENING. THE <br />ANNULAR SPACE BETWEEN THE CABLES AND THE PERIPHERY OF THE OPENING SHALL BE MIN 0 IN. (POINT CONTACT) TO MAX 1-1/2 IN. CABLE <br />BUNDLE TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF THE WALL ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF CABLES MAY BE USED: <br />A.MAX 200 PAIR NO. 24 AWG (OR SMALLER) COPPER CONDUCTOR WITH POLYVINYL CHLORIDE (PVC) INSULATION AND JACKETING MATERIAL. <br />B.MAX 1/C NO. 350 KCMIL (OR SMALLER) COPPER CONDUCTOR CABLE WITH CROSS-LINKED POLYETHYLENE (XLPE) JACKET. <br />C.MAX 7/C NO. 12 AWG (OR SMALLER) COPPER CONDUCTOR POWER AND CONTROL CABLES WITH XLPE OR PVC INSULATION WITH XLPE OR <br />PVC JACKET. <br />D.MAX 3/C NO. 2/0 AWG (OR SMALLER) COPPER OR ALUMINUM CONDUCTOR SER CABLES WITH PVC INSULATION AND JACKET. <br />E.MAX 3/C NO. 2/0 AWG (OR SMALLER) COPPER CONDUCTOR PVC JACKETED ALUMINUM CLAD OR STEEL CLAD TEK CABLE. <br />F.MAX 110/125 FIBER OPTIC (F.O.) CABLE WITH PVC INSULATION AND JACKET. <br />G.MAX 3/C WITH GROUND NO. 8 AWG (OR SMALLER) COPPER CONDUCTOR NM CABLE (ROMEX) WITH PVC INSULATION AND JACKET. <br />H.MAX RG/U COAXIAL CABLE WITH FLUORINATED ETHYLENE INSULATION AND JACKET. <br />I.MAX 4 PAIR NO. 24 AWG (OR SMALLER) COPPER CONDUCTOR DATA CABLE WITH HYLAR JACKET AND INSULATION. <br />3A.THROUGH PENETRATING PRODUCT* - AS AN ALTERNATE TO THE CABLES (ITEM 3), MAX 4-1/2 IN. DIAM TIGHT BUNDLE OF MAX 4/C NO. 2/0 AWG <br />(OR SMALLER) ALUMINUM OR STEEL ARMORED CABLE+ OR METAL CLAD CABLE+ INSTALLED WITHIN THE OPENING. ANNULAR SPACE <br />BETWEEN THROUGH-PENETRATING PRODUCTS AND PERIPHERY OF OPENING TO BE MIN 0 IN. (POINT CONTACT) TO MAX 1-1/2 IN. THROUGH <br />PENETRATING PRODUCT RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. WHEN ARMORED CABLE OR METAL CLAD CABLE IS <br />USED, T RATING IS 1/4 HR. <br />AFC CABLE SYSTEMS INC <br />4.FIRESTOP SYSTEM - THE FIRESTOP SYSTEM SHALL CONSIST OF THE FOLLOWING: <br />A.PACKING MATERIAL - MIN 1 IN. THICKNESS OF 4 PCF MINERAL WOOL BATT INSULATION COMPRESSED AND TIGHTLY PACKED INTO EACH <br />END OF SLEEVE. RECESS PACKING MATERIAL AS REQUIRED TO ACCOMMODATE FILL MATERIAL (ITEM 4B). <br />B.FILL, VOID OR CAVITY MATERIAL* - SEALANT - MIN 1/2 IN. THICKNESS OF FILL MATERIAL APPLIED WITHIN ANNULUS, FLUSH WITH EACH END <br />OF STEEL SLEEVE. AT POINT CONTACT LOCATION, MIN 1/4 IN. DIAM BEAD OF FILL MATERIAL APPLIED AT CABLE BUNDLE/STEEL SLEEVE <br />INTERFACE ON BOTH SIDES OF WALL. <br />SPECIFIED TECHNOLOGIES INC - SPECSEAL LCI SEALANT <br />*INDICATES SUCH PRODUCTS SHALL BEAR THE UL OR CUL CERTIFICATION MARK FOR JURISDICTIONS EMPLOYING THE UL OR CUL <br />CERTIFICATION (SUCH AS CANADA), RESPECTIVELY. <br />CABLE - MAX. 4 1/2" WITH STEEL <br />02_H_BB_ULWL3170 _CABLE 4.5 INCH WITH STEEL_1-2HR SCALE: 1 1/2" = 1'-0" <br />FIRE RESISTANCE LISTING: <br />U.L. DESIGN NO. <br />W-L-3170 <br />FIRE RATING: <br />1-HR or 2-HR <br />A <br />Section A-A <br />1A <br />1B <br />2 <br />3 <br />3 <br />2 <br />4B 4B 4A <br />A <br />SYSTEM NO. W-L-3169 <br />F RATINGS - 1 AND 2 HR (SEE ITEM 1) <br />T RATINGS - 1/4 AND 3/4 HR (SEE ITEM 2A) <br />1.WALL ASSEMBLY - THE 1 OR 2 HR FIRE-RATED GYPSUM BOARD/STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE <br />MATERIALS AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL U300 OR U400 SERIES WALL OR PARTITION DESIGN IN THE UL <br />FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES: <br />A.STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF <br />NOM 2 BY 4 IN. (51 BY 102 MM) LUMBER SPACED 16 IN. (406 MM) OC. STEEL STUDS TO BE MIN 3-5/8 IN. (92 MM) WIDE AND <br />SPACED MAX 24 IN. (610 MM) OC. <br />B.GYPSUM BOARD* - THICKNESS, TYPE, NUMBER OF LAYERS AND FASTENERS AS SPECIFIED IN THE INDIVIDUAL WALL AND <br />PARTITION DESIGN. MAX DIAM OF OPENING IS 5 IN. (127 MM). <br />THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS EQUAL TO THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN <br />WHICH IT IS INSTALLED. <br />2.CABLES - MAX 4-1/2 IN. DIAM TIGHT BUNDLE OF CABLES TO BE INSTALLED ECCENTRICALLY OR CONCENTRICALLY WITHIN THE <br />OPENING. THE ANNULAR SPACE BETWEEN THE CABLES AND THE PERIPHERY OF THE OPENING SHALL BE MIN 0 IN. (0 MM, POINT <br />CONTACT) TO MAX 1/2 IN. (13 MM). CABLE BUNDLE TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF THE FLOOR OR WALL <br />ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF CABLES MAY BE USED: <br />A.MAX 200 PAIR NO. 24 AWG (OR SMALLER) COPPER CONDUCTOR WITH POLYVINYL CHLORIDE (PVC) INSULATION AND <br />JACKETING MATERIAL. <br />B.MAX 1/C NO. 350 KCMIL (OR SMALLER) COPPER CONDUCTOR CABLE WITH CROSS-LINKED POLYETHYLENE (XLPE) JACKET. <br />C.MAX 7/C NO. 12 AWG (OR SMALLER) COPPER CONDUCTOR POWER AND CONTROL CABLES WITH XLPE OR PVC INSULATION <br />WITH XLPE OR PVC JACKET. <br />D.MAX 3/C NO. 2/0 AWG (OR SMALLER) COPPER OR ALUMINUM CONDUCTOR SER CABLES WITH PVC INSULATION AND JACKET. <br />E.MAX 3/C NO. 2/0 AWG (OR SMALLER) COPPER CONDUCTOR PVC JACKETED ALUMINUM CLAD OR STEEL CLAD TEK CABLE. <br />F.MAX 110/125 FIBER OPTIC (F.O.) CABLE WITH PVC INSULATION AND JACKET. <br />G.MAX 3/C WITH GROUND NO. 8 AWG (OR SMALLER) COPPER CONDUCTOR NM CABLE (ROMEX) WITH PVC INSULATION AND <br />JACKET. <br />H.MAX RG/U COAXIAL CABLE WITH FLUORINATED ETHYLENE INSULATION AND JACKET. <br />I.MAX 4 PAIR NO. 24 AWG (OR SMALLER) COPPER CONDUCTOR DATA CABLE WITH HYLAR JACKET AND INSULATION. <br />J.MAX 4/C (WITH GROUND) NO. 300 KCMIL (OR SMALLER) ALUMINUM CONDUCTOR SER CABLES WITH PVC INSULATION AND <br />JACKET. <br />2A. THROUGH PENETRATING PRODUCT* - AS AN ALTERNATE TO THE CABLES (ITEM 2), MAX 4 IN. (102 MM) DIAM TIGHT BUNDLE OF <br />MAX 4/C NO. 2/0 AWG (OR SMALLER) ALUMINUM OR STEEL ARMORED CABLE+ OR METAL CLAD CABLE+ INSTALLED WITHIN THE <br />OPENING. ANNULAR SPACE BETWEEN THROUGH-PENETRATING PRODUCTS AND PERIPHERY OF OPENING TO BE MIN 0 IN. (0 MM, <br />POINT CONTACT) TO MAX 1 IN. (25 MM). THROUGH PENETRATING PRODUCT RIGIDLY SUPPORTED ON BOTH SIDES OF FLOOR OR <br />WALL ASSEMBLY. WHEN ARMORED CABLE OR METAL CLAD CABLE IS USED, T RATING IS 1/4 HR. <br />AFC CABLE SYSTEMS INC <br />3.FILL, VOID OR CAVITY MATERIAL* - SEALANT - MIN 5/8 IN. (16 MM) THICKNESS OF FILL MATERIAL APPLIED WITHIN ANNULUS, <br />FLUSH WITH BOTH SURFACES OF WALL ASSEMBLY. SEALANT TO BE FORCED INTO INTERSTICES OF CABLE BUNDLE TO MAX <br />EXTENT POSSIBLE. AT POINT CONTACT LOCATION, MIN 1/4 IN. (6 MM) DIAM BEAD OF FILL MATERIAL APPLIED AT CABLE <br />BUNDLE/GYPSUM BOARD INTERFACE ON BOTH SURFACES OF WALL. <br />SPECIFIED TECHNOLOGIES INC - SPECSEAL LCI SEALANT <br />*INDICATES SUCH PRODUCTS SHALL BEAR THE UL OR CUL CERTIFICATION MARK FOR JURISDICTIONS EMPLOYING THE UL OR <br />CUL CERTIFICATION (SUCH AS CANADA), RESPECTIVELY. <br />CABLE - MAX. 4 1/2" <br />02_H_BB_ULWL3169 _CABLE 4.5 INCH_1-2HR SCALE: 1 1/2" = 1'-0" <br />FIRE RESISTANCE LISTING: <br />U.L. DESIGN NO. <br />W-L-3169 <br />FIRE RATING: <br />1-HR or 2-HR <br />A <br />Section A-AA <br />1B <br />33 <br />2 <br />2 <br />1A <br />SYSTEM NO. W-L-3171 <br />F RATINGS - 1 AND 2 HR (SEE ITEM 1) <br />T RATINGS - 1/4 AND 3/4 HR (SEE ITEM 2A) <br />1.WALL ASSEMBLY - THE 1 OR 2 HR FIRE-RATED GYPSUM BOARD/STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE <br />MATERIALS AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL U300 OR U400 SERIES WALL OR PARTITION DESIGN IN THE UL <br />FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES: <br />A.STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF <br />NOM 2 BY 4 IN. LUMBER SPACED 16 IN. OC. STEEL STUDS TO BE MIN 3-5/8 IN. WIDE AND SPACED MAX 24 IN. OC. <br />B.GYPSUM BOARD* - THICKNESS, TYPE, NUMBER OF LAYERS AND FASTENERS AS SPECIFIED IN THE INDIVIDUAL WALL AND <br />PARTITION DESIGN. MAX DIAM OF OPENING IS 1 IN. LARGER THAN OD OF CABLE (ITEM 2). <br />THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS EQUAL TO THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN <br />WHICH IT IS INSTALLED. <br />2.CABLE - ONE CABLE TO BE INSTALLED ECCENTRICALLY OR CONCENTRICALLY WITHIN THE OPENING. THE ANNULAR SPACE <br />BETWEEN THE CABLE AND THE PERIPHERY OF THE OPENING SHALL BE MIN 0 IN. (POINT CONTACT) TO MAX 1 IN. CABLE TO BE <br />RIGIDLY SUPPORTED ON BOTH SIDES OF THE FLOOR OR WALL ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF CABLE MAY <br />BE USED: <br />A.MAX 200 PAIR NO. 24 AWG (OR SMALLER) COPPER CONDUCTOR WITH POLYVINYL CHLORIDE (PVC) INSULATION AND <br />JACKETING MATERIAL. <br />B.MAX 1/C NO. 350 KCMIL (OR SMALLER) COPPER CONDUCTOR CABLE WITH CROSS-LINKED POLYETHYLENE (XLPE) JACKET. <br />C.MAX 7/C NO. 12 AWG (OR SMALLER) COPPER CONDUCTOR POWER AND CONTROL CABLES WITH XLPE OR PVC INSULATION <br />WITH XLPE OR PVC JACKET. <br />D.MAX 3/C NO. 2/0 AWG (OR SMALLER) COPPER OR ALUMINUM CONDUCTOR SER CABLES WITH PVC INSULATION AND JACKET. <br />E.MAX 3/C NO. 2/0 AWG (OR SMALLER) COPPER CONDUCTOR PVC JACKETED ALUMINUM CLAD OR STEEL CLAD TEK CABLE. <br />F.MAX 110/125 FIBER OPTIC (F.O.) CABLE WITH PVC INSULATION AND JACKET. <br />G.MAX 3/C WITH GROUND NO. 8 AWG (OR SMALLER) COPPER CONDUCTOR NM CABLE (ROMEX) WITH PVC INSULATION AND <br />JACKET. <br />H.MAX RG/U COAXIAL CABLE WITH FLUORINATED ETHYLENE INSULATION AND JACKET. <br />I.MAX 4 PAIR NO. 24 AWG (OR SMALLER) COPPER CONDUCTOR DATA CABLE WITH HYLAR JACKET AND INSULATION. <br />2A. THROUGH PENETRATING PRODUCT* - AS AN ALTERNATE TO THE CABLE (ITEM 2), ONE MAX 4/C NO. 2/0 AWG (OR SMALLER) <br />ALUMINUM OR STEEL ARMORED CABLE+ OR METAL CLAD CABLE+ INSTALLED WITHIN THE OPENING. ANNULAR SPACE <br />BETWEEN THROUGH-PENETRATING PRODUCT AND PERIPHERY OF OPENING TO BE MIN 0 IN. (POINT CONTACT) TO MAX 1 IN. <br />THROUGH PENETRATING PRODUCT RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. WHEN ARMORED CABLE OR <br />METAL CLAD CABLE IS USED, T RATING IS 1/4 HR. <br />AFC CABLE SYSTEMS INC <br />3.FILL, VOID OR CAVITY MATERIAL* - SEALANT - MIN 5/8 IN. THICKNESS OF FILL MATERIAL APPLIED WITHIN ANNULUS, FLUSH WITH <br />BOTH SURFACES OF WALL ASSEMBLY. AT POINT CONTACT LOCATION, MIN 1/4 IN. DIAM BEAD OF FILL MATERIAL APPLIED AT <br />CABLE/GYPSUM BOARD INTERFACE ON BOTH SURFACES OF WALL. <br />SPECIFIED TECHNOLOGIES INC - SPECSEAL LCI SEALANT <br />*INDICATES SUCH PRODUCTS SHALL BEAR THE UL OR CUL CERTIFICATION MARK FOR JURISDICTIONS EMPLOYING THE UL OR <br />CUL CERTIFICATION (SUCH AS CANADA), RESPECTIVELY. <br />CABLE - SINGLE <br />02_H_BB_ULWL3171 _CABLE SINGLE_1-2HR SCALE: 1 1/2" = 1'-0" <br />FIRE RESISTANCE LISTING: <br />U.L. DESIGN NO. <br />W-L-3171 <br />FIRE RATING: <br />1-HR or 2-HR <br />A <br />Section A-A <br />1A <br />2 <br />2 <br />33 <br />1BA <br />CABLES <br />02_H_BB_ULFC3057_CABLES_1-2HR SCALE: N.T.S. <br />FIRE RESISTANCE LISTING: <br />U.L. DESIGN NO. <br />FC-3057 <br />FIRE RATING: <br />1 - 2 HR <br />SYSTEM NO. F-C-3057 <br />F RATINGS - 1 HR AND 2 HR (SEE ITEM 1) <br />T RATING - 1/2 HR <br />1.FLOOR - CEILING ASSEMBLY - THE 1 HR FIRE-RATED WOOD JOIST FLOOR-CEILING ASSEMBLY SHALL BE CONSTRUCTED OF THE <br />MATERIALS AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL L500 DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY. THE 2 <br />HR FIRE-RATED WOOD JOIST FLOOR-CEILING ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER <br />SPECIFIED IN DESIGN NOS. L505, L511 OR L536 IN THE UL FIRE RESISTANCE DIRECTORY. THE F RATING OF THE FIRESTOP <br />SYSTEM IS EQUAL TO THE FIRE RATING OF THE FLOOR-CEILING ASSEMBLY. THE GENERAL CONSTRUCTION FEATURES OF THE <br />FLOOR ASSEMBLY ARE SUMMARIZED BELOW: <br />A.FLOORING SYSTEM - LUMBER OR PLYWOOD SUBFLOOR WITH FINISH FLOOR OF LUMBER, PLYWOOD OR FLOOR TOPPING <br />MIXTURE* AS SPECIFIED IN THE INDIVIDUAL FLOOR-CEILING DESIGN. MAX DIAM OF OPENING IS 3 IN. (76 MM). <br />B.WOOD JOISTS - NOM 10 IN. (254 MM) DEEP (OR DEEPER) LUMBER, STEEL OR COMBINATION LUMBER AND STEEL JOISTS, <br />TRUSSES OR STRUCTURAL WOOD MEMBERS* WITH BRIDGING AS REQUIRED AND WITH ENDS FIRESTOPPED. <br />C.GYPSUM BOARD* - THICKNESS, TYPE, NUMBER OF LAYERS AND FASTENERS AS REQUIRED IN THE INDIVIDUAL FLOOR-CEILING <br />DESIGN. MAX DIAM OF OPENING IS 3 IN. (76 MM). <br />1A. CHASE WALL - (OPTIONAL, NOT SHOWN) - THE THROUGH PENETRANT (ITEM 2) MAY BE ROUTED THROUGH A 1 OR 2 HR FIRE <br />RATED SINGLE, DOUBLE OR STAGGERED WOOD STUD/GYPSUM BOARD CHASE WALL. DEPTH OF CHASE WALL STUD CAVITY TO <br />BE MIN 1/2 IN. (13 MM) GREATER THAN DIAMETER OF OPENING CUT IN SOLE AND TOP PLATES TO ACCOMMODATE THE THROUGH <br />PENETRANT (ITEM 2). THE CHASE WALL SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER SPECIFIED IN THE <br />INDIVIDUAL U300 SERIES WALL AND PARTITION DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE <br />FOLLOWING CONSTRUCTION FEATURES: <br />A.STUDS - NOM 2 BY 4 IN. (51 BY 102 MM), 2 BY 6 IN. (51 BY 162 MM) OR DOUBLE NOM 2 BY 4 IN. (51 BY 102 MM) LUMBER STUDS. <br />B.SOLE PLATE - NOM 2 BY 4 IN. (51 BY 102 MM), 2 BY 6 IN. (51 BY 152 MM)OR PARALLEL 2 BY 4 IN. (51 BY 102 MM)LUMBER PLATES, <br />TIGHTLY BUTTED. MAX DIAM OF OPENING IS 3 IN. <br />C.TOP PLATE - THE DOUBLE TOP PLATE SHALL CONSIST OF TWO NOM 2 BY 4 IN. (51 BY 102 MM), TWO NOM 2 BY 6 IN. (51 BY 152 <br />MM)OR TWO SETS OF PARALLEL 2 BY 4 IN. (51 BY 102 MM)LUMBER PLATES, TIGHTLY BUTTED. MAX DIAM OF OPENING IS 3 IN. <br />(76 MM). <br />D.GYPSUM BOARD* - THICKNESS, TYPE, NUMBER OF LAYERS AND FASTENERS SHALL BE AS SPECIFIED IN THE INDIVIDUAL <br />WALL AND PARTITION DESIGN. <br />2.CABLES - AGGREGATE CROSS-SECTIONAL AREA OF CABLES WITHIN OPENING TO BE MAX 54 PERCENT OF THE <br />CROSS-SECTIONAL AREA OF THE OPENING. ANNULAR SPACE TO BE MIN 0 IN. (POINT CONTACT) TO MAX 1-1/4 IN. (32 MM). <br />PENETRANTS TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF FLOOR-CEILING ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF <br />CABLES MAY BE USED: <br />A.MAX 200 PAIR NO. 24 AWG (OR SMALLER) COPPER CONDUCTOR TELECOMMUNICATION CABLE WITH PVC INSULATION AND <br />JACKETING. <br />B.MAX 3/C NO. 3/0 AWG (OR SMALLER) ALUMINUM OR COPPER CONDUCTOR SER CABLE WITH PVC INSULATION AND JACKETING. <br />C.MAX 3/C WITH GROUND NO. 8 AWG (OR SMALLER) TYPE NM (ROMEX) NONMETALLIC SHEATHED CABLE WITH PVC INSULATION <br />AND JACKETING. <br />D.MAX 1/C - 350 KCMIL (OR SMALLER) POWER CABLES WITH XLP INSULATION AND JACKETING. <br />E.MAX 7/C NO. 12 AWG (OR SMALLER) POWER/CONTROL CABLES WITH PVC INSULATION AND JACKETING. <br />F.MAX RG/U (OR SMALLER) COPPER CONDUCTOR COAXIAL CABLE WITH FLUORINATED ETHYLENE INSULATION AND JACKETING <br />MATERIALS. <br />G.MAX 4 PAIR NO. 24 AWG (OR SMALLER) COPPER CONDUCTOR DATA CABLE WITH HYLAR INSULATION AND JACKETING. <br />H.MAX 4 PAIR NO. 18 AWG (OR SMALLER) COPPER CONDUCTOR INSTRUMENTATION CABLE WITH PVC INSULATION AND <br />JACKETING. <br />I.FIBER OPTIC CABLE WITH PVC INSULATION AND JACKETING. <br />J.MAX 4/C (WITH GROUND) NO. 300 KCMIL (OR SMALLER) ALUMINUM CONDUCTOR SER CABLES WITH PVC INSULATION AND <br />JACKET. <br />2A. THROUGH PENETRATING PRODUCT* - (NOT SHOWN) AS AN ALTERNATE ITEM 3), ONE OR MORE THROUGH-PENETRATING <br />PRODUCT TO BE INSTALLED WITHIN THE OPENING. MAX AGGREGATE CROSS-SECTIONAL AREA OF CABLES TO BE 52 PERCENT <br />OF THE CROSS-SECTIONAL AREA OF THE OPENING. ANNULAR SPACE BETWEEN THROUGH-PENETRATING PRODUCTS AND <br />PERIPHERY OF OPENING TO BE MIN 0 IN. (POINT CONTACT) TO MAX 1-1/4 IN. (32 MM). THROUGH PENETRATING PRODUCT <br />RIGIDLY SUPPORTED ON BOTH SIDES OF FLOOR OR WALL ASSEMBLY. THE FOLLOWING TYPES OF THROUGH-PENETRATING <br />PRODUCTS MAY BE USED: <br />A.MAX 4/C WITH GROUND NO. 2/0 AWG (OR SMALLER) ALUMINUM OR COPPER CONDUCTOR ALUMINUM OR STEEL JACKETED <br />ARMORED CABLE# + OR METAL-CLAD CABLE+. <br />AFC CABLE SYSTEMS INC <br />ENCORE WIRE CORP <br />B.TWO OR MORE TWISTED COPPER CONDUCTORS NO. 6 AWG (OR SMALLER) POWER LIMITED CIRCUIT CABLE+ WITH OR <br />WITHOUT A JACKET UNDER A METAL ARMOR. <br />AFC CABLE SYSTEMS INC <br />C.TWO OR MORE TWISTED COPPER CONDUCTORS NO. 10 AWG (OR SMALLER) POWER LIMITED FIRE ALARM CABLE+ WITH OR <br />WITHOUT A JACKET UNDER A METAL ARMOR. <br />AFC CABLE SYSTEMS INC <br />D.MAX TWO TWISTED COPPER CONDUCTORS NO. 12 AWG (OR SMALLER) NON POWER LIMITED FIRE ALARM CABLE+ WITH OR <br />WITHOUT A JACKET UNDER A METAL ARMOR. <br />AFC CABLE SYSTEMS INC <br />3.FILL, VOID OR CAVITY MATERIAL* - SEALANT - MIN 3/4 IN. (19 MM) THICKNESS OF FILL MATERIAL APPLIED WITHIN THE ANNULUS, <br />FLUSH WITH THE TOP SURFACE OF THE FLOOR OR CHASE WALL SOLE PLATE. MIN 5/8 IN. (16 MM) THICKNESS OF FILL MATERIAL <br />APPLIED WITHIN THE ANNULUS, FLUSH WITH BOTTOM SURFACE OF CEILING OR CHASE WALL TOP PLATE. AT POINT CONTACT, <br />MIN 1/4 IN. (6 MM) DIAM BEAD OF FILL MATERIAL APPLIED AT CABLE BUNDLE/SUBFLOOR OR CHASE WALL SOLE PLATE <br />INTERFACE AND AT CABLE BUNDLE/CEILING OR CHASE WALL TOP PLATE INTERFACE. <br />SPECIFIED TECHNOLOGIES INC - SPECSEAL LCI SEALANT <br />+BEARING THE UL LISTING MARK <br />**INDICATES SUCH PRODUCTS SHALL BEAR THE UL OR CUL CERTIFICATION MARK FOR JURISDICTIONS EMPLOYING THE UL OR <br />CUL CERTIFICATION (SUCH AS CANADA), RESPECTIVELY. <br />3 <br />Section A-A <br />2 1A3 <br />1C <br />3 <br />2 <br />1B <br />A <br />A <br />SYSTEM NO. F-C-2032 <br />F RATING - 1 HR <br />T RATINGS - 0, 1/4, 3/4 AND 1 HR (SEE ITEM 2) <br />L RATING AT AMBIENT - LESS THAN 1 CFM/SQ FT <br />L RATING AT 400 F - LESS THAN 1 CFM/SQ FT <br />1.FLOOR - CEILING ASSEMBLY - THE 1 HR FIRE-RATED SOLID OR TRUSSED LUMBER JOIST FLOOR-CEILING ASSEMBLY SHALL BE <br />CONSTRUCTED OF THE MATERIALS AND IN THE MANNER SPECIFIED IN INDIVIDUAL L500 SERIES FLOOR-CEILING DESIGNS IN THE <br />UL FIRE RESISTANCE DIRECTORY. THE GENERAL CONSTRUCTION DETAILS OF THE FLOOR-CEILING ASSEMBLY ARE <br />SUMMARIZED BELOW: <br />A.FLOORING SYSTEM - LUMBER OR PLYWOOD SUBFLOOR WITH FINISH FLOOR OF LUMBER, PLYWOOD OR FLOOR TOPPING <br />MIXTURE* AS SPECIFIED IN THE INDIVIDUAL FLOOR-CEILING DESIGN. MAX DIAM OF FLOOR OPENING IS 4 IN. (102 MM). <br />B.WOOD JOISTS - NOM 2 BY 10 IN. (51 BY 254 MM) LUMBER JOISTS SPACED 16 IN. (406 MM) OC WITH NOM 1 BY 3 IN. (25 BY 76 <br />MM) LUMBER BRIDGING AND WITH ENDS FIRESTOPPED. AS AN ALTERNATE TO LUMBER JOISTS, NOM 10 IN. (254 MM) DEEP <br />(OR DEEPER) LUMBER, STEEL OR COMBINATION LUMBER AND STEEL JOISTS, TRUSSES OR STRUCTURAL WOOD MEMBERS* <br />WITH BRIDGING AS REQUIRED AND WITH ENDS FIRESTOPPED. <br />C.FURRING CHANNELS - (NOT SHOWN) - RESILIENT GALV STEEL FURRING INSTALLED PERPENDICULAR TO WOOD JOISTS (ITEM <br />1B) BETWEEN GYPSUM BOARD (ITEM 1D) AND WOOD JOISTS AS REQUIRED IN THE INDIVIDUAL FLOOR-CEILING DESIGN. <br />D.GYPSUM BOARD* - NOM 4 FT (1.2 M) WIDE BY 5/8 IN. (16 MM) THICK AS SPECIFIED IN THE INDIVIDUAL FLOOR-CEILING DESIGN. <br />GYPSUM BOARD SECURED TO WOOD JOISTS OR FURRING CHANNELS AS SPECIFIED IN THE INDIVIDUAL FLOOR-CEILING <br />DESIGN. MAX DIAM OF CEILING OPENING IS 4 IN. (102 MM). <br />1.1 CHASE WALL - (OPTIONAL. NOT SHOWN) - THE THROUGH PENETRANT (ITEM NO. 2) MAY BE ROUTED THROUGH A FIRE RATED OR <br />NON FIRE RATED SINGLE, DOUBLE OR STAGGERED WOOD STUD/GYPSUM BOARD CHASE WALL. WHEN FIRE RATED THE CHASE <br />WALL SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL U300 SERIES WALL AND <br />PARTITION DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION <br />FEATURES: <br />A.STUDS - NOM 2 BY 4 IN. (51 BY 102 MM), 2 BY 6 IN. (51 BY 152 MM) OR DOUBLE 2 BY 4 IN. (51 BY 102 MM) LUMBER STUDS. <br />B.SOLE PLATE - NOM 2 BY 4 IN. (51 BY 102 MM), 2 BY 6 IN. (51 BY 152 MM) OR PARALLEL 2 BY 4 IN. (51 BY 102 MM) LUMBER <br />PLATES, TIGHTLY BUTTED. <br />C.TOP PLATE - THE DOUBLE TOP PLATE SHALL CONSIST OF TWO NOM 2 BY 4 IN. (51 BY 102 MM) OR 2 BY 6 IN. (51 BY 152 MM) OR <br />TWO SETS OF PARALLEL 2 BY 4 IN. (51 BY 102 MM) LUMBER PLATES, TIGHTLY BUTTED. MAX DIAM OF OPENING IS 4 IN. (102 <br />MM). <br />D.GYPSUM BOARD* - THICKNESS, TYPE, NUMBER OF LAYERS AND FASTENERS SHALL BE AS SPECIFIED IN INDIVIDUAL WALL <br />AND PARTITION DESIGN. <br />2.THROUGH-PENETRANTS - ONE NONMETALLIC PIPE, CONDUIT OR TUBING TO BE INSTALLED WITHIN THE FIRESTOP SYSTEM. <br />DIAM OF OPENINGS HOLE-SAWED THROUGH FLOORING SYSTEM AND THROUGH GYPSUM BOARD CEILING TO BE 1/4 TO 1-5/8 IN. <br />(6 TO 41 MM) LARGER THAN THE OUTSIDE DIAM OF THROUGH-PENETRANT. PIPE, CONDUIT OR TUBING TO BE RIGIDLY <br />SUPPORTED ON BOTH SIDES OF THE FLOOR-CEILING ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF NONMETALLIC PIPES, <br />CONDUITS OR TUBING MAY BE USED: <br />A.POLYVINYL CHLORIDE (PVC) PIPE - NOM 2 IN. (51 MM) DIAM (OR SMALLER) SCHEDULE 40 SOLID OR CELLULAR CORE PVC PIPE <br />FOR USE IN CLOSED (PROCESS OR SUPPLY) OR VENTED (DRAIN, WASTE OR VENT) PIPING SYSTEMS. THE T RATING FOR THE <br />FIRESTOP SYSTEM WHEN THIS PENETRANT IS USED IS 1 HR EXCEPT THAT WHEN NOM DIAM OF PIPE EXCEEDS 1 IN. (25 MM), <br />THE T RATING IS 1/4 HR. <br />B.RIGID NONMETALLIC CONDUIT (RNC)+ - NOM 2 IN. (51 MM) DIAM (OR SMALLER) SCHEDULE 40 PVC CONDUIT INSTALLED IN <br />ACCORDANCE WITH ARTICLE 347 OF THE NATIONAL ELECTRICAL CODE (NFPA NO. 70). THE T RATING FOR THE FIRESTOP <br />SYSTEM WHEN THIS PENETRANT IS USED IS 1 HR EXCEPT THAT WHEN NOM DIAM OF PIPE EXCEEDS 1 IN. (25 MM), THE T <br />RATING IS 1/4 HR. <br />C.CHLORINATED POLYVINYL CHLORIDE (CPVC) PIPE - NOM 2 IN. (51 MM) DIAM (OR SMALLER) SDR 17 CPVC PIPE FOR USE IN <br />CLOSED (PROCESS OR SUPPLY) OR VENTED (DRAIN, WASTE OR VENT) PIPING SYSTEMS. THE T RATING FOR THE FIRESTOP <br />SYSTEM WHEN THIS PENETRANT IS USED IS 1 HR EXCEPT THAT WHEN NOM DIAM OF PIPE EXCEEDS 1 IN. (25 MM), THE T <br />RATING IS 1/4 HR. <br />D.ACRYLONITRILE BUTADIENE STYRENE (ABS) PIPE - NOM 2 IN. (51 MM) DIAM (OR SMALLER) SCHEDULE 40 CELLULAR OR SOLID <br />CORE ABS PIPE FOR USE IN CLOSED (PROCESS OR SUPPLY) OR VENTED (DRAIN, WASTE OR VENT) PIPING SYSTEMS. THE T <br />RATING FOR THE FIRESTOP SYSTEM WHEN THIS PENETRANT IS USED IS 0 HR. <br />E.POLYBUTYLENE (PB) PIPE - NOM 1 IN. (25 MM) DIAM (OR SMALLER) SDR 11 PB PIPE FOR USE IN CLOSED (PROCESS OR <br />SUPPLY) PIPING SYSTEMS. THE T RATING FOR THE FIRESTOP SYSTEM WHEN THIS PENETRANT IS USED IS 1 HR. <br />F.CROSS LINKED POLYETHYLENE ALUMINUM-CROSS LINKED POLYETHYLENE (PEX AL-PEX) TUBING - NOM 1 IN. (25 MM) DIAM <br />(OR SMALLER) SDR 5 PEX-AL-PEX TUBING FOR USE IN CLOSED (PROCESS OR SUPPLY) PIPING SYSTEMS. THE T RATING FOR <br />THE FIRESTOP SYSTEM WHEN THIS PENETRANT IS USED IS 3/4 HR. <br />G.CROSS LINKED POLYETHYLENE (PEX) TUBING - NOM 2 IN. (51 MM) DIAM (OR SMALLER) SDR 9 PEX TUBING FOR USE IN <br />CLOSED (PROCESS OR SUPPLY) PIPING SYSTEMS. THE T RATING FOR THE FIRESTOP SYSTEM WHEN THIS PENETRANT IS <br />USED IS 1 HR. <br />H.ELECTRICAL NONMETALLIC TUBING (ENT)+ - NOM 2 IN. (51 MM) DIAM (OR SMALLER) PVC TUBING INSTALLED IN ACCORDANCE <br />WITH ARTICLE 331 OF THE NATIONAL ELECTRICAL CODE (NFPA NO. 70). THE T RATING FOR THE FIRESTOP SYSTEM WHEN <br />THIS PENETRANT IS USED IS 1 HR EXCEPT THAT WHEN NOM DIAM OF TUBE EXCEEDS 1 IN. (25 MM), THE T RATING IS 1/4 HR. <br />I.CHLORINATED POLYVINYL CHLORIDE (CPVC) PIPE - NOM 2 IN. (51 MM) DIAM (OR SMALLER) SCHEDULE 80 CPVC PIPE FOR USE <br />IN CLOSED (PROCESS OR SUPPLY) PIPING SYSTEMS. <br />WHEN 2A, 2B, 2C, 2E, 2F, 2G, 2H OR 2I IS USED, THE ANNULAR SPACE SHALL BE MIN 0 IN. (POINT CONTACT) TO MAX 1-5/8 IN. (41 <br />MM). WHEN 2D IS USED, THE ANNULAR SPACE SHALL BE MIN 0 IN. (POINT CONTACT) TO MAX 1 IN. (25 MM) EXCEPT THAT <br />WHEN NOM PIPE DIAM EXCEEDS 1-1/2 IN. (38 MM), THE MAX ANNULAR SPACE IS 5/8 IN. (16 MM). <br />3.FILL, VOID OR CAVITY MATERIAL* - SEALANT - MIN 3/4 IN. (19 MM) THICKNESS OF FILL MATERIAL APPLIED WITHIN ANNULUS ON <br />TOP SURFACE OF FLOOR. MIN 5/8 IN. (16 MM) THICKNESS OF FILL MATERIAL APPLIED WITHIN ANNULUS ON BOTTOM SURFACE OF <br />CEILING OR LOWER TOP PLATE OF CHASE WALL ASSEMBLY. ADDITIONAL FILL MATERIAL TO BE INSTALLED SUCH THAT A MIN 1/8 <br />IN. (3 MM) CROWN IS FORMED AROUND THE THROUGH PENETRANT ON BOTTOM SURFACE OF CEILING OR LOWER PLATE OF <br />CHASE WALL ASSEMBLY. <br />SPECIFIED TECHNOLOGIES INC - SPECSEAL SERIES SSS SEALANT, R SPECSEAL LCI SEALANT, OR TYPE WF300 FIRESTOP CAULK <br />+BEARING THE UL LISTING MARK <br />*BEARING THE UL CLASSIFICATION MARKING <br />PIPE, CONDUIT, ALUMINUM OR TUBING <br />02_H_BB_ULFC2032 _SINGLE NON-METALLIC 2" PIPE_1HR SCALE: 1 1/2" = 1'-0" <br />FIRE RESISTANCE LISTING: <br />U.L. DESIGN NO. <br />F-C-2032 <br />FIRE RATING: <br />1-HR <br />2 <br />3 <br />1A <br />1B <br />3 2 <br />1C 3 <br />1.FLOOR - CEILING ASSEMBLY - THE 1 HR FIRE-RATED WOOD JOIST FLOOR-CEILING ASSEMBLY SHALL BE CONSTRUCTED OF THE <br />MATERIALS AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL L500 DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY. THE 2 <br />HR FIRE-RATED WOOD JOIST FLOOR-CEILING ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER <br />SPECIFIED IN DESIGN NOS. L505, L511 OR L536 IN THE UL FIRE RESISTANCE DIRECTORY. THE F AND FH RATINGS OF THE <br />FIRESTOP SYSTEM ARE EQUAL TO THE FIRE RATING OF THE FLOOR-CEILING ASSEMBLY. THE GENERAL CONSTRUCTION <br />FEATURES OF THE FLOOR ASSEMBLY ARE SUMMARIZED BELOW: <br />A.FLOORING SYSTEM - LUMBER OR PLYWOOD SUBFLOOR WITH FINISH FLOOR OF LUMBER, PLYWOOD OR FLOOR TOPPING <br />MIXTURE* AS SPECIFIED IN THE INDIVIDUAL FLOOR-CEILING DESIGN. DIAM OF OPENING TO BE MAX 1 IN. (25 MM) LARGER <br />THAN DIAM OF PIPE. AS AN ALTERNATE, THE OPENING MAY BE SQUARE-CUT WITH A MAX DIMENSION 1 IN. (25 MM) GREATER <br />THAN THE DIAM OF THE PIPE. <br />B.WOOD JOISTS - NOM 10 IN. (254 MM) DEEP (OR DEEPER) LUMBER, STEEL OR COMBINATION LUMBER AND STEEL JOISTS, <br />TRUSSES OR STRUCTURAL WOOD MEMBERS* WITH BRIDGING AS REQUIRED AND WITH ENDS FIRESTOPPED. <br />C.GYPSUM BOARD* - THICKNESS, TYPE, NUMBER OF LAYERS AND FASTENERS AS REQUIRED IN THE INDIVIDUAL <br />FLOOR-CEILING DESIGN. DIAM OF OPENING TO BE MAX 1 IN. (25 MM) GREATER THAN DIAM OF PIPE. <br />D.FURRING CHANNEL - (NOT SHOWN) - IN 2 HR FIRE-RATED ASSEMBLIES, RESILIENT GALV STEEL FURRING CHANNELS <br />INSTALLED PERPENDICULAR TO WOOD JOISTS BETWEEN BASE AND FACE LAYERS OF GYPSUM BOARD (ITEM C). FURRING <br />CHANNELS SPACED MAX 24 IN. (610 MM) OC WITH ADDITIONAL SHORT LENGTHS OF FURRING CHANNEL INSTALLED ADJACENT <br />TO AND MAX 3 IN. (76 MM) FROM TWO OPPOSING SIDES OF PENETRANT. <br />1A. CHASE WALL - (OPTIONAL, NOT SHOWN) - THE THROUGH PENETRANT (ITEM 2) MAY BE ROUTED THROUGH A SINGLE, DOUBLE <br />OR STAGGERED WOOD STUD/GYPSUM BOARD CHASE WALL. DEPTH OF CHASE WALL STUD CAVITY TO BE MIN 1 IN. (25 MM) <br />GREATER THAN THE DIAMETER OF THE THROUGH PENETRANT (ITEM 2). THE CHASE WALL SHALL INCLUDE THE FOLLOWING <br />CONSTRUCTION FEATURES: <br />A.STUDS - NOM 2 BY 4 IN. (51 BY 102 MM), 2 BY 6 IN. (51 BY 152 MM) OR DOUBLE NOM 2 BY 4 IN. (51 BY 102 MM) LUMBER STUDS. <br />B.SOLE PLATE - NOM 2 BY 4 IN. (51 BY 102 MM), 2 BY 6 IN. (51 BY 152 MM) OR PARALLEL 2 BY 4 IN. (51 BY 102 MM) LUMBER <br />PLATES, TIGHTLY BUTTED. DIAM OF OPENING IS TO BE MAX 1 IN. (25 MM) LARGER THAN DIAM OF PIPE. AS AN ALTERNATE, <br />THE OPENING MAY BE SQUARE-CUT WITH A MAX DIMENSION 1 IN. (25 MM) GREATER THAN THE DIAM OF THE PIPE. PLATES <br />MAY BE DISCONTINUOUS OVER OPENING, TERMINATING AT TWO OPPOSING EDGES OF OPENING. MAX LENGTH OF <br />DISCONTINUITY IS 5-1/2 IN. (140 MM). <br />C.TOP PLATE - THE SINGLE OR DOUBLE TOP PLATE SHALL CONSIST OF TWO NOM 2 BY 4 IN. (51 BY 102 MM), OR ONE OR TWO <br />NOM 2 BY 6 IN. (51 BY 152 MM), OR ONE OR TWO SETS OF PARALLEL 2 BY 4 IN. (51 BY 102 MM), LUMBER PLATES, TIGHTLY <br />BUTTED. DIAM OF OPENING IS TO BE MAX 1 IN. (25 MM) LARGER THAN DIAM OF PIPE. AS AN ALTERNATE, THE OPENING MAY <br />BE SQUARE-CUT WITH A MAX DIMENSION 1 IN. (25 MM) GREATER THAN THE DIAM OF THE PIPE. PLATES MAY BE <br />DISCONTINUOUS OVER OPENING, TERMINATING AT TWO OPPOSING EDGES OF OPENING. MAX LENGTH OF DISCONTINUITY IS <br />5-1/2 IN. (140 MM). <br />D.STEEL PLATE - WHEN LUMBER PLATES ARE DISCONTINUOUS, NOM 1-1/2 IN. (38 MM) WIDE NO. 20 GAUGE (OR HEAVIER) GALV <br />STEEL PLATES SHALL BE INSTALLED TO CONNECT DISCONTINUOUS LUMBER PLATES AND TO PROVIDE A FORM FOR THE FILL <br />MATERIAL. STEEL PLATES SIZED TO LAP 2 IN. (51 MM) ONTO EACH DISCONTINUOUS LUMBER PLATE AND SECURED TO <br />LUMBER PLATES WITH STEEL SCREWS OR NAILS. <br />E.GYPSUM BOARD* - MIN. 1./2 IN. THICK RATED OR NON-RATED GYPSUM BOARD. <br />2.THROUGH PENETRANT - ONE METALLIC PIPE, CONDUIT OR TUBING TO BE INSTALLED EITHER CONCENTRICALLY OR <br />ECCENTRICALLY WITHIN THE OPENING. ANNULAR SPACE TO BE MIN 0 IN. (POINT CONTACT) TO MAX 1 IN. (0 TO 25 MM). <br />PENETRANT TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF FLOOR-CEILING ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF <br />METALLIC PIPE, CONDUIT OR TUBING MAY BE USED: <br />A.STEEL PIPE - NOM 4 IN. (102 MM) DIAM (OR SMALLER) SCHEDULE 5 (OR HEAVIER) STEEL PIPE. <br />B.IRON PIPE - NOM 4 IN. (102 MM) DIAM (OR SMALLER) CAST OR DUCTILE IRON PIPE. <br />C.CONDUIT - NOM 4 IN. (102 MM) DIAM (OR SMALLER) STEEL CONDUIT, STEEL ELECTRICAL METALLIC TUBING OR FLEXIBLE <br />STEEL CONDUIT. <br />D.COPPER PIPE OR TUBE - NOM 4 IN. (102 MM) DIAM (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE OR TYPE L (OR <br />HEAVIER) COPPER TUBE. <br />THE T, FT AND FTH RATINGS ARE 1/4 HR WHEN COPPER PIPE OR TUBE IS USED IN 1 HR FIRE-RATED ASSEMBLIES. THE T, FT <br />AND FTH RATINGS ARE 1/2 HR WHEN COPPER PIPE OR TUBE IS USED IN 2 HR FIRE-RATED ASSEMBLIES. WHEN STEEL PIPE, <br />IRON PIPE, STEEL CONDUIT OR FLEXIBLE METAL PIPING (ITEM 2A) IS USED, T, FT AND FTH RATINGS ARE 1 HR. <br />2A. THROUGH PENETRATING PRODUCT* - FLEXIBLE METAL PIPING - AS AN ALTERNATE TO ITEM 2, ONE NOM 2 IN. (51 MM) DIAM (OR <br />SMALLER) STEEL FLEXIBLE METAL PIPE TO BE INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP <br />SYSTEM. ANNULAR SPACE TO BE MIN 0 IN. (POINT CONTACT) TO MAX 1 IN. (0 TO 25 MM). PENETRANT TO BE RIGIDLY SUPPORTED <br />ON BOTH SIDES OF FLOOR-CEILING ASSEMBLY. <br />OMEGA FLEX INC <br />GASTITE, DIV OF TITEFLEX <br />WARD MFG L L C <br />3.FILL, VOID OR CAVITY MATERIAL* - SEALANT - MIN 3/4 IN. (19 MM) THICKNESS OF FILL MATERIAL APPLIED WITHIN THE ANNULUS, <br />FLUSH WITH THE TOP SURFACE OF THE FLOOR OR SOLE PLATE. MIN 5/8 IN. (16 MM) THICKNESS OF FILL MATERIAL APPLIED <br />WITHIN THE ANNULUS, FLUSH WITH BOTTOM SURFACE OF CEILING OR TOP PLATE. MIN 1/4 IN. (6 MM) DIAM BEAD OF FILL <br />MATERIAL APPLIED AT POINT CONTACT LOCATION ON THE TOP SURFACE OF FLOOR OR SOLE PLATE AND AT THE <br />PENETRANT/CEILING OR TOP PLATE INTERFACE. <br />SPECIFIED TECHNOLOGIES INC - SPECSEAL LCI SEALANT OR TYPE WF300 FIRESTOP CAULK <br />*INDICATES SUCH PRODUCTS SHALL BEAR THE UL OR CUL CERTIFICATION MARK FOR JURISDICTIONS EMPLOYING THE UL OR <br />CUL CERTIFICATION (SUCH AS CANADA), RESPECTIVELY. <br />PIPE, CONDUIT, OR TUBING <br />02_H_BB_ULFC1074 _SINGLE METALLIC 4" OR SCALE: 1 1/2" = 1'-0" <br />FIRE RESISTANCE LISTING: <br />U.L. DESIGN NO. <br />F-C-1074 <br />FIRE RATING: <br />1-2HR <br />FLEX PIPE_1-2HR <br />System No. F-C-1074 <br />ANSI/UL1479 (ASTM E814) <br />F Ratings - 1 Hr and 2 Hr (See Item 1) <br />T Ratings - 1/4, 1/2 and 1 Hr (See Item 2) <br />L Rating At Ambient - Less Than 1 CFM/sq ft <br />L Rating At 400 F - Less Than 1 CFM/sq ft <br />CAN/ULC S115 <br />F Ratings - 1 Hr and 2 Hr (See Item 1) <br />FT Ratings - 1/4, 1/2 and 1 Hr (See Item 2) <br />FH Ratings - 1 Hr and 2 Hr (See Item 1) <br />FTH Ratings - 1/4, 1/2 and 1 Hr (See Item 2) <br />L Rating At Ambient - Less Than 5.1 L/s/m2 <br />L Rating At 400 F - Less Than 5.1 L/s/m2 <br />DRAIN PIPE <br />02_H_BB_ULFC7060_STEEL DUCT 6" OR SMALLER SCALE: 1 1/2" = 1'-0" <br />FIRE RESISTANCE LISTING: <br />U.L. DESIGN NO. <br />F-C-2156 <br />FIRE RATING: <br />1 HR <br />SYSTEM NO. F-C-2156 <br />F RATING - 1 HR <br />T RATING - 1 HR <br />1.FLOOR-CEILING ASSEMBLY - THE 1 HR FIRE-RATED SOLID OR TRUSSED LUMBER JOIST FLOOR-CEILING ASSEMBLY SHALL BE <br />CONSTRUCTED OF THE MATERIALS AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL L500 SERIES FLOOR-CEILING DESIGNS <br />IN THE UL FIRE RESISTANCE DIRECTORY. THE GENERAL CONSTRUCTION FEATURES OF THE FLOOR-CEILING ASSEMBLY ARE <br />SUMMARIZED BELOW: <br />A.FLOORING SYSTEM - LUMBER OR PLYWOOD SUBFLOOR WITH FINISH FLOOR OF LUMBER, PLYWOOD OR FLOOR <br />TOPPING MIXTURE* AS SPECIFIED IN THE INDIVIDUAL FLOOR-CEILING DESIGN. RECTANGULAR CUTOUT IN FLOORING TO <br />ACCOMODATE THE BATHTUB DRAIN PIPING (ITEM 2) TO BE MAX 8 IN. BY 12 IN. CUTOUT TO BE PATCHED ON UNDERSIDE OF <br />SUBFLOOR USING ONE LAYER OF MIN 3/4 IN. THICK PLYWOOD OR MIN 5/8 IN. THICK GYPSUM WALLBOARD (ITEM 1C) SIZED <br />TO LAP MIN 2 IN. BEYOND EACH EDGE OF RECTANGULAR CUTOUT. DIAM OF OPENING HOLE-SAWED THROUGH PATCH TO <br />ACCOMODATE DRAIN PIPING (ITEM 2) TO BE 1 IN. LARGER THAN OUTSIDE DIAM OF DRAIN PIPING AND POSITIONED SUCH <br />THAT DRAIN PIPING IS CENTERED IN OPENING. PATCH SPLIT INTO TWO PIECES AT OPENING HOLE-SAWED FOR BATHTUB <br />DRAIN PIPING. TWO PIECES POSITIONED AROUND DRAIN PIPING, WITH CUT EDGES TIGHTLY BUTTED, AND <br />SCREW-ATTACHED TO UNDERSIDE OF SUBFLOOR WITH 1-1/4 IN. LONG TYPE S STEEL SCREWS SPACED MAX 6 IN. OC. <br />B.WOOD JOISTS* - NOM 10 IN. DEEP (OR DEEPER) LUMBER, STEEL OR COMBINATION LUMBER AND STEEL JOISTS, <br />TRUSSES OR STRUCTURAL WOOD MEMBERS* WITH BRIDGING AS REQUIRED AND WITH ENDS FIRESTOPPED. <br />C.GYPSUM BOARD* - NOM 4 FT. WIDE BY 5/8 IN. THICK, ATTACHED AS DESCRIBED IN THE INDIVIDUAL FLOOR-CEILING <br />DESIGN. <br />2.DRAIN PIPING - NOM 1-1/2 IN. DIAM (OR SMALLER) SCHEDULE 40 CELLULAR OR SOLID CORE POLYVINYL CHLORIDE (PVC) <br />ACRYLONITRILE BUTADIENE STYRENE (ABS), OR SDR17 CHLORINATED POLYVINYL CHLORIDE (CPVC) PIPE AND DRAIN FITTINGS <br />CEMENTED TOGETHER AND PROVIDED WITH PVC, ABS OR CPVC BATHTUB WASTE/OVERFLOW FITTINGS. THE ANNULAR SPACE <br />SHALL BE A MIN 3/8 IN. TO MAX 5/8 IN. <br />3.FILL, VOID OR CAVITY MATERIAL* - SEALANT - MIN 5/8 IN. DEPTH OF FILL MATERIAL APPLIED WITHIN ANNULAR SPACE, <br />FLUSH WITH BOTH SURFACES OF PLYWOOD OR GYPSUM WALLBOARD PATCH. <br />SPECIFIED TECHNOLOGIES INC - SPECSEAL SERIES SSS SEALANT OR SPECSEAL LCI SEALANT <br />* BEARING THE UL CLASSIFICATION MARK <br />1C <br />1A 3 <br />1B <br />2 <br />1 <br />37111519 <br />1721 <br />23 <br />13 9 5STEEL DUCT <br />02_H_BB_ULCAJ7040_STEEL DUCT_2HR_Concrete SCALE: N.T.S. <br />FIRE RESISTANCE LISTING: <br />U.L. DESIGN NO. <br />C-AJ-7040 <br />FIRE RATING: <br />2-HR <br />SYSTEM NO. C-AJ-7040 <br />F RATING - 2 HR <br />T RATING - 1/4 HR <br />1. FLOOR ASSEMBLY - MIN 4-1/2 IN. (114 MM) THICK REINFORCED LIGHTWEIGHT OR NORMAL WEIGHT (100-150 PCF OR 1600-2400 KG/M3) <br />CONCRETE FLOOR. FLOOR MAY ALSO BE CONSTRUCTED OF ANY MIN 6 IN. (152 MM) THICK HOLLOW-CORE PRECAST CONCRETE UNITS*. WALL <br />MAY ALSO BE CONSTRUCTED OF ANY UL CLASSIFIED CONCRETE BLOCKS*. MAX DIAM OF OPENING IS 10 IN. (254 MM). MAX DIAM OF OPENING IN <br />FLOORS CONSTRUCTED OF HOLLOW-CORE CONCRETE IS 7 IN. (178 MM). <br />SEE CONCRETE BLOCKS (CAZT) OR PRECAST CONCRETE UNITS (CFTV) CATEGORIES IN THE FIRE RESISTANCE DIRECTORY FOR NAMES OF <br />MANUFACTURERS. <br />2. STEEL SLEEVE - (OPTIONAL) - NOM 14 IN. (356 MM) DIAM (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL PIPE CAST OR GROUTED INTO FLOOR <br />OR WALL ASSEMBLY. STEEL SLEEVE MAY BE INSTALLED FLUSH OR MAY PROJECT A MAX OF 2 IN. (51 MM) BEYOND THE FLOOR OR WALL <br />SURFACES. <br />3. STEEL DUCT - ONE NOM 12 IN. (305 MM) DIAM (OR SMALLER) GALV STEEL DUCT. STEEL GAUGE OF DUCT SHALL CONFORM WITH SMACNA <br />REQUIREMENTS. STEEL DUCT TO BE INSTALLED ECCENTRICALLY OR CONCENTRICALLY WITHIN THE FIRESTOP SYSTEM. THE ANNULAR SPACE <br />BETWEEN THE STEEL DUCT AND THE PERIPHERY OF THE OPENING SHALL BE MIN 0 IN. (POINT CONTACT) TO MAX 2 IN. (51 MM). STEEL DUCT TO <br />BE RIGIDLY SUPPORTED ON BOTH SIDES OF THE FLOOR OR WALL ASSEMBLY. <br />4. FIRESTOP SYSTEM - THE FIRESTOP SYSTEM SHALL CONSIST OF THE FOLLOWING: <br />A. PACKING MATERIAL - MIN 3 IN. (76 MM) THICKNESS OF MIN 4 PCF (64 KG/M3) MINERAL WOOL BATT INSULATION COMPRESSED AND TIGHTLY <br />PACKED INTO OPENING. PACKING MATERIAL RECESSED FROM TOP SURFACE OF FLOOR OR BOTH SURFACES OF WALL OR PRECAST <br />CONCRETE UNITS TO ACCOMMODATE THE REQUIRED THICKNESS OF FILL MATERIAL. WHEN STEEL SLEEVE PROJECTS FROM TOP OF FLOOR <br />OR FROM BOTH SIDES OF WALL, THE THICKNESS OF MINERAL WOOL BATT PACKING MATERIAL SHOULD BE INCREASED BY AN AMOUNT <br />EQUAL TO THE DISTANCE THAT THE SLEEVE EXTENDS PAST THE FLOOR OR WALL SURFACE. <br />B. FILL, VOID OR CAVITY MATERIAL* - SEALANT - MIN 1/2 IN. (13 MM) THICKNESS OF FILL MATERIAL APPLIED WITHIN ANNULUS, FLUSH WITH TOP <br />SURFACE OF FLOOR ASSEMBLY OR TOP EDGE OF STEEL SLEEVE. IN WALLS, MIN 1/2 IN. (13 MM) THICKNESS OF FILL MATERIAL APPLIED <br />FLUSH WITH BOTH SURFACES OF WALL ASSEMBLY OR BOTH ENDS OF STEEL SLEEVE. IN FLOORS CONSTRUCTED OF HOLLOW-CORE <br />PRECAST CONCRETE UNITS, FILL MATERIAL INSTALLED SYMMETRICALLY ON BOTH SIDES OF FLOOR. AT POINT CONTACT LOCATION, MIN 1/4 <br />IN. (6 MM) DIAM BEAD OF FILL MATERIAL INSTALLED AT STEEL DUCT/CONCRETE OR STEEL DUCT/STEEL SLEEVE INTERFACE ON TOP <br />SURFACE OF FLOOR OR BOTH SURFACES OF WALL OR PRECAST CONCRETE UNITS. <br />SPECIFIED TECHNOLOGIES INC - SPECSEAL LCI SEALANT <br />*INDICATES SUCH PRODUCTS SHALL BEAR THE UL OR CUL CERTIFICATION MARK FOR JURISDICTIONS EMPLOYING THE UL OR CUL <br />CERTIFICATION (SUCH AS CANADA), RESPECTIVELY. <br />3 <br />4B 12 <br />4A <br />3 <br />2 4A <br />4B <br />STEEL DUCT <br />02_H_BB_ULCAJ7041_STEEL DUCT_2HR_Concrete SCALE: N.T.S. <br />FIRE RESISTANCE LISTING: <br />U.L. DESIGN NO. <br />C-AJ-7041 <br />FIRE RATING: <br />2-HR <br />2 <br />3C <br />3B 1 <br />3A <br />2 <br />3C <br />3A <br />3B <br />SYSTEM NO. C-AJ-7041 <br />F RATING - 2 HR <br />T RATING - 0 HR <br />L RATING AT AMBIENT - LESS THAN 1 CFM/SQ FT. <br />L RATING AT 400 F - LESS THAN 1 CFM/SQ FT. <br />1. FLOOR OR WALL ASSEMBLY - MIN 4-1/2 IN. (114 MM) THICK REINFORCED LIGHTWEIGHT OR NORMAL WEIGHT (100-150 PCF OR <br />1600-2400 KG/M3) CONCRETE FLOOR. WHEN LC150 OR LE600 SEALANT (ITEM 3B) IS USED, THE MIN WALL THICKNESS IS 5 IN. (127 <br />MM). WALL MAY ALSO BE CONSTRUCTED OF ANY UL CLASSIFIED CONCRETE BLOCKS* MAX AREA OF OPENING IS 1024 SQ IN. (0.66 <br />M3) WITH A MAX DIMENSION OF 32 IN. (81 CM). <br />SEE CONCRETE BLOCKS (CAZT) CATEGORY IN THE FIRE RESISTANCE DIRECTORY FOR NAMES OF MANUFACTURERS. <br />2. STEEL DUCT - NOM 30 BY 30 IN. (76 BY 76 CM) (OR SMALLER) NO. 24 GA (OR HEAVIER) GALV STEEL DUCT INSTALLED <br />ECCENTRICALLY OR CONCENTRICALLY WITHIN OPENING. STEEL GAUGE OF DUCT SHALL CONFORM WITH SMACNA <br />REQUIREMENTS. ANNULAR SPACE BETWEEN DUCT AND PERIPHERY OF OPENING TO BE MIN 1/4 IN. TO MAX 1-3/4 IN. DUCT TO BE <br />RIGIDLY SUPPORTED ON BOTH SIDES OF THE FLOOR OR WALL ASSEMBLY. <br />3. FIRESTOP SYSTEM - THE FIRESTOP SYSTEM SHALL CONSIST OF THE FOLLOWING: <br />A. PACKING MATERIAL - MIN 4 PCF (64 KG/M3) MINERAL WOOL BATT INSULATION COMPRESSED AND TIGHTLY PACKED TO MIN 3 <br />IN. (76 MM) THICKNESS. PACKING MATERIAL RECESSED FROM TOP SURFACE OF FLOOR OR BOTH SURFACES OF WALL AS <br />REQUIRED TO ACCOMMODATE FILL MATERIAL (ITEM 3B). <br />B. FILL VOID OR CAVITY MATERIALS* - SEALANT - MIN 1/2 IN. (13 MM) THICKNESS OF FILL MATERIAL APPLIED WITHIN THE <br />ANNULUS, FLUSH WITH TOP SURFACE OF FLOOR ASSEMBLY OR BOTH SURFACES OF WALL ASSEMBLY. WHEN LC150 OR LE600 <br />SEALANT IS USED, THE MIN SEALANT THICKNESS IS 1 IN. (25 MM). <br />SPECIFIED TECHNOLOGIES INC - SPECSEAL LCI SEALANT, SPECSEAL LC150 SEALANT, OR SPECSEAL LE600 SEALANT. <br />C. RETAINING ANGLES - MIN 16 GA (0.059 IN. OR 1.5 MM) GALV STEEL ANGLES SIZED TO LAP DUCT A MIN OF 2 IN. (51 MM) AND LAP <br />PERIPHERY OF OPENING A MIN OF 1 IN. (25 MM). ANGLES ATTACHED TO ALL FOUR SIDES OF STEEL DUCT ON TOP SURFACE OF <br />FLOOR OR BOTH SURFACES OF WALL WITH NO. 10 (OR LARGER) STEEL SHEET METAL SCREWS SPACED 1 IN. (25 MM) FROM <br />EACH END AND MAX 4 IN. (102 MM) OC. <br />*INDICATES SUCH PRODUCTS SHALL BEAR THE UL OR CUL CERTIFICATION MARK FOR JURISDICTIONS EMPLOYING THE UL OR <br />CUL CERTIFICATION (SUCH AS CANADA), RESPECTIVELY. <br />1 <br />1 <br />HOLD- 829 N <br />Garfield St1/15/2025