My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
HOLD- 829 N Garfield St - Plan
PBA
>
Building
>
ProjectDox
>
G
>
Garfield St
>
829 N Garfield St
>
HOLD- 829 N Garfield St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:11:36 PM
Creation date
6/1/2025 12:11:15 PM
Metadata
Fields
Template:
Plan
Permit Number
20583473
20583704
30547537
40539325
105120166
Full Address
829 N Garfield St
829 N Garfield St Unit# 1
Permit Number (Not in SAPIN)
20583408
20583409
20583410
20583411
20583412
20583413
20583414
20583416
20583417
Rectangle
ID:
1
Creator:
Import Agent
Created:
6/1/2025 12:11 PM
Modified:
5/30/2025 5:25 PM
ID:
2
Creator:
Import Agent
Created:
6/1/2025 12:11 PM
Modified:
5/30/2025 5:25 PM
ID:
3
Creator:
Import Agent
Created:
6/1/2025 12:11 PM
Modified:
5/30/2025 5:25 PM
ID:
4
Creator:
Import Agent
Created:
6/1/2025 12:11 PM
Modified:
5/30/2025 5:25 PM
ID:
5
Creator:
Import Agent
Created:
6/1/2025 12:11 PM
Modified:
5/30/2025 5:25 PM
ID:
6
Creator:
Import Agent
Created:
6/1/2025 12:11 PM
Modified:
5/30/2025 5:25 PM
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
93
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CCOPYRIGHT <br />It is the clients responsibility prior to or during construction to notify the architect in writing <br />of any perceived errors or omissions in the plans and specifications of which a contractor <br />thoroughly knowledgeable with the building codes and methods of construction should <br />reasonably be aware. Written instructions addressing such perceived errors or omissions <br />shall be received from the architect prior to the client or clients subcontractors proceeding <br />with the work. The client will be responsible for any defects in construction if these <br />procedures are not followed. <br />Zohrabians Art of Design <br />700 Palm Drive, Suite 106 <br />Glendale, CA 91202 <br />zartofdesign.com <br />818.300.9420 <br />No.Date Description <br />06/05/2024 100% DD SET <br />06/14/2024 50% CD PROGRESS SET <br />06/21/2024 75% CD PROGRESS SET <br />07/02/2024 NEIGHBORHOOD REVIEW <br />07/10/2024 1ST PLAN CHECK SUBMITTAL <br />82 <br />9 <br /> <br />N <br />. <br /> <br />G <br />A <br />R <br />F <br />I <br />E <br />L <br />D <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />Santa Ana, CA 92701 <br />829 N. Garfield Street <br />Name: <br />Project Contact: <br />Phone: <br />Email: <br /> <br />Principal: <br />Z.AOD Project No:2024-02 <br />Arthur Zohrabians <br />818.300.9420 <br />Arthur Zohrabians <br />info@zartofdesign.com <br />Phone No.:949.922.7075 <br />Email:vanitapuri@gmail.com <br />Owner <br />GA <br />R <br />F <br />I <br />E <br />L <br />D <br /> <br />R <br />E <br />S <br />T <br />O <br />R <br />A <br />T <br />I <br />O <br />N <br /> <br />/ <br /> <br />R <br />E <br />M <br />O <br />D <br />E <br />L <br />Address: <br />Ren.11/30/25 <br />A <br />No. C37490 <br />A <br />A FOILOFC <br />R <br />INTA <br />S <br />ET <br />TC <br />A RCHITE <br />DESNECIL <br />RTHUR <br />HAMAYAK ZOHRABI <br />A <br />SN <br />VVS Estates, LLC <br />Vanita Soni PuriAttn: <br />5 <br />6 <br />8 <br />1913 <br />18 <br />17 <br />EXTERIOR DETAILS <br />A910 <br />14 <br />3 <br />4 <br />REINFORCED @ REENTRANT CORNERS <br />SCALE: 3"=1'-0"FILE NAME: <br />EXTERIOR CEMENT PLASTER O/ WIRE <br />LATH O/ W.R.B. <br />FLASHING SCREED OR SOFFIT DRIP AS <br />REQUIRED AT OPENING; SEE <br />REFERENCED DOOR, WINDOW OR <br />WALL OPENING DETAIL FOR TYPE. <br />EXTEND SCREED OR DRIP 2" PAST <br />OPENING UNLESS NOTED OTHERWISE. <br />MINIMUM 12" SQUARE EXPANDED <br />METAL LATH REINFORCEMENT AT <br />OPENING. PROVIDE AT ALL DOOR, <br />WINDOW AND OPENING CORNERS <br />WHERE CONTROL JOINTS DO NOT <br />OCCUR. WIRE TIE PATCHING LATH TO <br />WIRE LATH AT 4" O.C. INCREMENTS <br />DOOR, <br />WINDOW <br />OR WALL <br />OPENING <br />2"1' <br />- <br />0 <br />" <br /> <br />S <br />Q <br /> <br />E <br />X <br />P <br />A <br />N <br />D <br />E <br />D <br /> <br />M <br />E <br />T <br />A <br />L <br /> <br />L <br />A <br />T <br />H <br />6" <br />1'-0" <br />EXTERIOR DETAIL NOTES <br />SCALE: N.T.S.FILE NAME: <br />NOTE: <br />EXPANSION / CONTROL JOINTS SHALL BE INSTALLED TO COMPLY WITH ASTM C1063. JOINTS IN WALLS <br />SHALL DELINEATE AREAS NOT MORE THAN 144 SQUARE FEET AND CEILINGS NOT MORE THAN 100 <br />SQUARE FEET. THE MAXIMUM DISTANCE BETWEEN JOINTS SHALL BE 18 FEET IN EITHER DIRECTION OR <br />A LENGTH TO WIDTH RATIO NOT EXCEEDING 2 1/2 : 1. LATH SHALL NOT BE CONTINUOUS THROUGH <br />CONTROL JOINTS BUT SHALL BE STOPPED AND WIRE TIED AT EACH SIDE. <br />W.R.B.WEATHER RESISTIVE BARRIER (W.R.B.) BY HENRY CO. BUILDING ENVELOPE SYSTEMS. <br />SUPER JUMBO TEX 60 MIN BLDG. PAPER O/ WEATHERSMART HOUSEWRAP AIR BARRIER. <br />PER 2022 CRC SEC. R703.7.3.1, MIN. REQ. SHALL BE 2 LAYERS OF 10-MIN. GRADE "D" PAPER. <br />FLASHING MULTI-LAYERED COMPOSITE POLYOLEFIN FLASHING 12" WIDE (U.N.O.) <br />FORTIFIBER MOISTOP NEXT OR APPROVED EQUAL <br />SEALANT POLYURETHANE SEALANT FORTIFIBER MOISTOP SEALANT OR APPROVED EQUAL. <br />AT A MINIMUM, EXPOSED SEALANT SHALL BE CHECKED ANNUALLY AND MAINTAINED <br />PER MANUFACTURERS RECOMMENDATION TO MAINTAIN A WATER TIGHT SEAL. <br />SELF ADHESIVE, HEALING FLASHING (S.A.F.) 12" WIDE (U.N.O.) 25 MIL (U.N.O.) <br />FORTIFIBER FORTIFLASH OR APPROVED EQUAL. ADHERE S.A.F. TO CLEAN, DUST <br />FREE BACKING USING CHEMICALLY COMPATIBLE MATERIALS AND/OR PRIMERS. <br />PROVIDE SOLID WOOD BACKING OR SHEATHING BEHIND ALL AREAS TO RECEIVE <br />SELF ADHESIVE, HEALING FLASHING. <br />WIRE LATH HEXAGONAL WOVEN-WIRE-FABRIC LATH WITH 1 1/2" OPENINGS OF 17-GAGE <br />GALVANIZED WIRE OR 1" OPENINGS OF 18-GAGE WIRE. USE SELF-FURRING RUST <br />RESISTANT NAILS OR SELF-FURRING DEVICES TO KEEP REINFORCING LATH AT <br />LEAST 1/4" AWAY FROM THE SUPPORTS. USE POWER ACTUATED FASTENERS WHEN <br />LATH IS APPLIED TO CONCRETE OR C.M.U. WALLS. <br />EXPANDED <br />METAL LATH <br />WITH DIAMOND-MESH TO WEIGH A MINIMUM 1.5 LB. PER YARD FOR USE ON WALLS <br />AND A MINIMUM 3.4 LB. PER YARD FOR USE ON CEILINGS. <br />GSM FLASHING GSM FLASHING METAL SHALL BE SHOP FABRICATED USING A MINIMUM 26 GA. <br />BONDERIZED GALVANIZED SHEET METAL WITH SOLDERED JOINTS U.N.O.. STUCCO <br />ACCESSORIES SHALL BE CEMCO WATER MANAGEMENT SERIES, 25 GA. MATERIAL <br />WITH A G-90 GALVANIZED COATING OR ARCHITECT APPROVED EQUAL, UNLESS <br />NOTED OTHERWISE. <br />BOND BREAKER POLYETHYLENE TAPE TO BE USED AS BOND BREAKER, REQUIRED BETWEEN <br />ACRYLIC PLASTER AND PAINT FINISHES AND ALL WEEPING SOLID LEG FLASHING. <br />TAPE SHOULD RUN FROM THE SOLID VERTICAL LEG TO 1/8" FROM FRONT EDGE. <br />ANY APPLIED FINISHE THAT CREATES A BOND BETWEEN THE PLASTER AND METAL <br />SHALL BE BROKEN WITH UTILITY KNIFE AND SHALL BE MAINTAINED AS SUCH. <br />S.A.F. <br />2 <br />TYPICAL EXTERIOR CEMENT PLASTER <br />SCALE: 3"=1'-0"FILE NAME: <br />SOFFIT <br />WALL <br />GALVANIZED EXPANDED METAL LATH APPROVED <br />FOR USE ON HORIZONTAL SURFACES, SPAN <br />RATED FOR STRUCTURAL MEMBER SPACING <br />WEATHER BARRIER / UNDERLAYMENT (W.R.B.) * : <br />1 LAYER BUILDING PAPER O/ 1 LAYER AIR BARRIER. <br />REFER TO DETAIL 4 ON THIS SHEET & NOTE BELOW. <br />EXTERIOR CEMENT PLASTER ASSEMBLY: <br />3 COAT PORTLAND CEMENT PLASTER <br />PER CBC CHAPTER 25. <br />WEATHER BARRIER / UNDERLAYMENT * : <br />1 LAYER BUILDING PAPER O/ 1 LAYER <br />AIR BARRIER. REFER TO DETAIL 4 / -. <br />GALVANIZED METAL LATH APPROVED <br />FOR USE ON VERTICAL SURFACES. <br />VERIFY PLASTER FINISH w/ <br />ARCHITECT. TEXTURE TO MATCH <br />PLASTER OF (E) S.F. RESIDENCE. <br />SCRATCH COAT <br />BROWN COAT <br />FINISH COAT <br />LINE OF FRAMING / <br />SUBSTRATE <br />THIS DETAIL DESCRIBES TYPICAL GENERAL <br />ASSEMBLY COMPONENTS & INSTALLATION <br />PROCEDURE. REFER TO ACTUAL CONDITIONS & <br />KEYED DETAILS FOR DIMENSIONS, CONFIGURATIONS <br />& OTHER SPECIFICS OF THE WORK. <br />* NOTE RE: WEATHER RESISTIVE BARRIER (W.R.B.) <br />W.R.B. ( AS SPECIFIED ) IS INTENDED TO DELIVER <br />GREATER WATER RESISTANCE THAN REQ. BY CODE. <br />PER 2022 CRC SEC. R703.7.3.1, MIN. REQ. W.R.B. <br />SHALL BE 2 LAYERS OF 10-MIN. GRADE 'D' PAPER. <br />TYPICAL EXTERIOR PLASTER SYSTEM COMPONENTS <br />SCALE: 3" = 1'-0"FILE NAME: <br />SELF ADHESIVE FLASHING (S.A.F.) <br />BEHIND SHEET METAL FLASHING <br />FOR INTEGRATION WITH <br />ADJACENT WATERPROOFING/ <br />ROOFING CONDITIONS <br />EXTERIOR GYPSUM SHEATHING <br />AND SHEAR PANELS PER WALL <br />TYPES AND STRUCTURAL <br />DRAWINGS <br />DRIP / WEEP SCREED <br />FINISH COATING SYSTEM <br />7/8" EXTERIOR CEMENT <br />PLASTER PER DETAIL 1 / - <br />WIRE METAL LATH <br />CONT SHEET METAL DRIP FLASHING, <br />PROVIDE END DAMS AT ALL DRIP <br />FLASHING TERMINATIONS UNO <br />W.R.B. (SEE DETAILS 1 & 4) <br />1 LAYER BUILDING PAPER <br />O/ 1 LAYER AIR BARRIER <br />3" <br />20 <br />22 <br />STUCCO WEEP SCREED <br />SCALE: 3"=1'-0"FILE NAME: <br />GYP. BD. <br />(WHERE <br />OCCURS) <br />SELF ADHERED FLEXIBLE <br />FLASHING O/ NO. 26 GA. G.S.M. <br />WEEP SCREED W/ 3-1/2" <br />FLANGE AT EXT. CEM. PLASTER <br />WALL FRAM'G <br />INSULATION <br />(WHERE OCCURS) <br />3-COAT EXTERIOR <br />CEMENT PLASTER <br />O/ WIRE LATH O/ W.R.B. <br />W.R.B. (MIN. 2 LAYERS OF <br />GRADE "D" BLDG. PAPER) <br />CONC. <br />SLAB <br />BLDG. SHT'G <br />(WHERE <br />OCCURS) <br />2" <br />MI <br />N <br />. <br />6" <br /> <br />M <br />I <br />N <br />. <br /> <br />T <br />O <br /> <br />G <br />R <br />A <br />D <br />E <br />8" <br /> <br />M <br />I <br />N <br />. <br /> <br />T <br />O <br /> <br />G <br />R <br />A <br />D <br />E <br />PRIMED BLDG. <br />SHT'G <br />G.S.M. FLASHING O/ <br />PRE STRIP W/ S.A.F. BUTYL. <br />2" <br />CONCRETE PAVING <br />MI <br />N <br />. <br />SEAL STRIP <br />SLOPE <br />1/4" = 1'-0" MAX <br />1 <br />- <br />STUCCO CONTROL JOINTS <br />SCALE: 3"=1'-0"FILE NAME: <br />2x SOLID BACKING REQUIRED WHEN <br />SHEATHING NOT PROVIDED WHERE <br />S.A.F. IS REQUIRED. <br />EXTERIOR CEMENT PLASTER <br />O/ WIRE LATH O/ W.R.B. <br />WALL FRAMING PER STRUCTURAL <br />DRAWINGS <br />SHEATHING MAY OCCUR <br />WIRE LATH O/ W.R.B. O/ 9" WIDE S.A.F. <br />O/ CEMCO #15 SOLID LEG CONTROL <br />JOINT OVER 9" WIDE FLASHING O/ W.R.B <br />CEMCO #15 SOLID LEG CONTROL <br />JOINT AT EACH FLOOR LEVEL, TYP. <br />CONTROL JOINT SHALL BE <br />CONTINUOUS, NOT INTERRUPTED BY <br />VERTICAL CONTROL JOINTS. <br />TOP OF FLOOR SHEATHING TYP. <br />2x SOLID BACKING REQUIRED AT <br />S.A.F. WHEN SHEATHING NOT <br />PROVIDED AT FLASHING <br />EXTERIOR CEMENT PLASTER <br />O/ WIRE LATH O/ W.R.B. <br />FLOOR FRAMING PER STRUCTURAL <br />DRAWINGS <br />WIRE TIE WIRE LATH TO BOTTOM <br />FLANGE OF CEMCO #15 JOINT; NO <br />NAILS, SCREWS OR STAPLES. WIRE <br />LATH TO BE CUT AND INSTALLED <br />WITHOUT CONNECTION TO WIRE <br />LATH ABOVE THE CONTROL JOINT. <br />CEMCO DOUBLE "J" CONTROL JOINT <br />(#XJ-15), TYPICAL AT ALL VERTICAL <br />LOCATIONS. INSTALL #XJ-15 OVER <br />THE CONTINUOUS SOLID LEG OF THE <br />CEMCO #15 JOINT. <br />CUT WIRE LATH AND WIRE TIE WIRE <br />LATH TO EACH FLANGE OF THE CEMCO <br />DOUBLE "J" CONTROL JOINT; NO NAILS, <br />SCREWS OR STAPLES ALLOWED SO <br />THAT THE CONTROL JOINT CAN EXPAND <br />AND CONTRACT. <br />CEMCO DOUBLE "J" CONTROL JOINT <br />(#XJ-15). INSTALL #XJ-15 OVER THE <br />CONTINUOUS LEG OF THE V VERTICAL <br />DOUBLE "J" CONTROL JOINT. <br />THE HORIZONTAL JOINT SHALL STAND <br />OFF 1/4" FROM THE VERTICAL JOINT ON <br />EACH SIDE TO ALLOW FOR MOVEMENT, <br />CAULK EACH SEPARATION <br />W.R.B. SHALL RUN CONTINUOUS <br />BEHIND ALL CEMCO DOUBLE "J" <br />CONTROL JOINTS. <br />FOR ADDITIONAL INFORMATION SEE DETAIL <br />BLOCKING AS REQUIRED TO PROVIDE <br />REQUIRED LATH ATTACHMENT TO <br />STRUCTURE <br />1/4" <br />4 <br />- <br />1 <br />- <br />EXTERIOR CEMENT PLASTER <br />O/ WIRE LATH O/ W.R.B. <br />CEILING FRAMING PER STRUCTURAL <br />DRAWINGS * <br />SHEATHING MAY OCCUR <br />WIRE TIE WIRE LATH TO CEMCO #30 <br />CORNER EXPANSION JOINT O/ W.R.B <br />AND EXPANDED METAL LATH * <br />EXTERIOR CEMENT PLASTER <br />O/ WIRE LATH O/ W.R.B. <br />WALL FRAMING PER STRUCTURAL <br />DRAWINGS <br />SHEATHING MAY OCCUR <br />WIRE TIE WIRE LATH TO CEMCO #30 <br />CORNER EXPANSION JOINT O/ W.R.B <br />EXPANDED METAL LATH * <br />WALL FRAMING PER STRUCTURAL <br />DRAWINGS <br />SHEATHING MAY OCCUR <br />EXTERIOR CEMENT PLASTER <br />O/ WIRE LATH O/ W.R.B. <br />WALL FRAMING PER STRUCTURAL <br />DRAWINGS <br />SHEATHING MAY OCCUR <br />CEMCO NO. 1-A CORNER BEAD <br />* IF SHEATHING IS APPLIED TO THE CEILING FRAMING, APPLY W.R.B BETWEEN THE SHEATHING AND <br />EXPANDED METAL LATH. CONTINUE CEILING W.R.B. DOWN AND OVER THE WALL W.R.B 2" MINIMUM. <br />FOR ADDITIONAL INFORMATION SEE DETAILS <br />STUCCO CORNERS <br />SCALE: 3"=1'-0"FILE NAME: <br />WALL/CEILING <br />INSIDE CORNER <br />WALL/WALL <br />OUTSIDE CORNER <br />WALL/WALL <br />INSIDE CORNER <br />4 <br />- <br />2 <br />- <br />SHEATHING PROTECTION <br />SCALE: 3"=1'-0"FILE NAME: <br />HARDSCAPE, SLOPE AWAY FROM <br />BUILDING, MAX 2% CROSS SLOPE <br />BUILDING SLAB / FOUNDATION <br />FRAMING PER STRUCTURAL <br />DRAWINGS (DOOR JAMB STUD) <br />CEMCO #7 EXTENDED FOUNDATION <br />SCREED, APPLY SEALANT BETWEEN <br />SCREED AND J-SERIES CASING BEAD <br />SHEATHING PER STRUCTURAL <br />SET PRESERVATIVE TREATED SILL <br />PLATE ON 3 CONTINUOUS BEADS OF <br />NON HARDENING CAULK <br />CEMCO J-SERIES CASING BEAD <br />(SHEATHING PROTECTION), HOLD 1/8" <br />OFF DOOR FRAME AND APPLY <br />SEALANT ALL AROUND BEAD TO <br />FRAME <br />2 CONTINUOUS BEADS OF SEALANT <br />2 <br />1 <br />/ <br />2 <br />" <br />1/2" <br />1/ <br />2 <br />" <br />1/2 <br />" <br />1/4 <br />" <br /> <br /> <br /> <br /> <br /> <br />L <br />A <br />N <br />D <br />I <br />N <br />G <br /> <br />S <br />L <br />O <br />P <br />E <br /> <br />1 <br />/ <br />4 <br />" <br /> <br />= <br /> <br />1 <br />' <br />- <br />0 <br />" <br /> <br />M <br />A <br />X <br />PRO <br />V <br />I <br />D <br />E <br /> <br />S <br />H <br />E <br />A <br />T <br />H <br />I <br />N <br />G <br />PRO <br />T <br />E <br />C <br />T <br />I <br />O <br />N <br /> <br />U <br />N <br />T <br />I <br />L <br /> <br />S <br />H <br />E <br />A <br />T <br />H <br />I <br />N <br />G <br /> <br />I <br />S <br />2" A <br />B <br />O <br />V <br />E <br /> <br /> <br />A <br />D <br />J <br />A <br />C <br />E <br />N <br />T <br /> <br />H <br />A <br />R <br />D <br />S <br />C <br />A <br />P <br />E <br />2" <br />A <br />T <br />HA <br />R <br />D <br />S <br />C <br />A <br />P <br />E <br />14 <br />- <br />WALL PENETRATION w/ QUICKFLASH <br />SCALE: 3"=1'-0"FILE NAME: <br />SHEATHING MAY OCCUR <br />W.R.B. O/ "FLASHING PANEL" O/ W.R.B. <br />TUCKED BEHIND "FLASHING PANEL", <br />PROVIDE MINIMUM CUT OUT IN W.R.B. <br />AROUND PENETRATING ITEM. <br />EXTERIOR CEMENT PLASTER <br />O/ WIRE LATH O/ W.R.B. <br />WALL FRAMING PER STRUCTURAL <br />DRAWINGS <br />PENETRATING ELEMENT SEE MEP <br />AND/OR OTHER CONSTRUCTION <br />DOCUMENTS TO IDENTIFY NEED <br />W.R.B. FROM ABOVE O/ "FLASHING <br />PANEL" O/ W.R.B. TUCKED BEHIND <br />PANEL UP TO PENETRATING ITEM <br />2x SOLID BACKING REQUIRED AT <br />S.A.F. WHEN SHEATHING NOT <br />PROVIDED AT FLASHING <br />QUICKFLASH WEATHERPROOFING <br />PRODUCTS "FLASHING PANEL", <br />IDENTIFY THE PENETRATING ITEM <br />AND PROVIDE APPLICABLE FLASHING <br />PANEL. USE NON-CORRODING <br />ANCHORS <br />iF SQUARE OR RECTANGULAR PENETRATING ITEM CANNOT BE FLASHED USING <br />QUICKFLASH, FLASH PENITRATING ITEM USING COLLAR FLASHING PER DETAIL <br />WALL PENETRATION WITH COLLAR <br />SCALE: 3"=1'-0"FILE NAME: <br />PROVIDE 3/16" ROLLED OR ANGLED <br />STUCCO GROUND EDGE TO PERMIT <br />PLASTER TO KEY UNDERNEATH THE <br />EDGE FOR ADDED ADHESION <br />G.S.M. FLASHING METAL <br />INTEGRAL 7/8" STUCCO SCREED ALL <br />FOUR SIDES <br />4" <br />4" <br />4" <br />4" <br />PENETRATION OPENING TO BE 1" <br />WIDER AND TALLER THAN THE <br />PENETRATING ITEM TO ALLOW 1/2" <br />WIDE SEALANT JOINT ON ALL SIDES <br />OF PENETRATING ITEM <br />PENETR <br />A <br />T <br />I <br />N <br />G <br /> <br />I <br />T <br />E <br />M <br /> <br />( <br />W <br />I <br />D <br />T <br />H <br /> <br />O <br />R <br /> <br />H <br />E <br />I <br />G <br />H <br />T <br />) <br /> <br />P <br />L <br />U <br />S <br /> <br />9 <br />" <br />1/ <br />2 <br />" <br />1/ <br />2 <br />" <br />G.S.M. FLASHING COLLAR <br />W.R.B. O/ 9" WIDE S.A.F. O/ W.R.B <br />WIRE LATH O/ W.R.B. O/ COLLAR O/ 9" <br />WIDE S.A.F. <br />EXTERIOR CEMENT PLASTER <br />O/ WIRE LATH O/ W.R.B. <br />SHEATHING MAY OCCUR <br />2x SOLID BACKING REQUIRED WHEN <br />SHEATHING NOT PROVIDED WHERE <br />S.A.F. IS REQUIRED. <br />W.R.B. O/ 9" WIDE S.A.F. O/ FLASHING <br />COLLAR <br />SEALANT AND BACKER ROD; ALL <br />SIDES <br />PENETRATING ELEMENT SEE MEP <br />AND/OR OTHER CONSTRUCTION <br />DOCUMENTS TO IDENTIFY <br />PENETRATING ITEMS <br />WALL FRAMING PER STRUCTURAL <br />DRAWINGS <br />EXTERIOR WALL PENETRATION FLASHING COLLAR <br />EXTERIOR SIDE <br />7/8" <br />EXTERIOR LIGHT FIXTURE AT STUCCO <br />SCALE: 3"=1'-0"FILE NAME: <br />EXTERIOR CEMENT PLASTER <br />O/ WIRE LATH O/ W.R.B. <br />2x SOLID BACKING REQUIRED WHEN <br />SHEATHING NOT PROVIDED WHERE S.A.F. IS <br />REQUIRED. <br />W.R.B. O/ 9" WIDE S.A.F. O/ W.R.B. <br />SHEATHING MAY OCCUR <br />WALL SCONCE <br />LIGHT FIXTURE. <br />REFER TO <br />KEYNOTE U1 <br />ON SHEET A210. <br />WIRE LATH <br />O/ W.R.B. <br />O/ COLLAR <br />O/ 9" WIDE S.A.F. <br />W.R.B. O/ 9" WIDE <br />S.A.F. O/ FLASHING <br />AT TOP & SIDES OF <br />QUICKFLASH COLLAR <br /> ELECTRICAL <br />BOX W/ <br />QUICKFLASH <br />COLLAR FOR <br />STUCCO <br />APPLICATION <br />1923 <br />NOT USED <br />NOT USED <br />VENT HOOD AT 1HR EXTERIOR WALL <br />SCALE: 3"=1'-0"FILE NAME: <br />POWER VENT PVC <br />3 1/2" <br />SELF ADHERED FLASHING <br />(2) 2x BLOCKING T&B OF OPENING <br />PVC VENT PIPE TERMINAL W/ WIRE <br />SCREEN FABRIC PER POWER <br />VENT SUPPLIER <br />SELF ADHERED FLASHING <br />INSTALL ALL AROUND OPENING <br />BLDG. PAPER <br />5/8" "TYPE "X" 1-HR GYP. BD. <br />FIRESTOP SEALANT ALL AROUND <br />2" <br />1/ <br />8 <br />" <br /> <br />M <br />A <br />X <br />. <br />1" <br />MILCOR PLASTER STOP CONT. <br />BETWEEN SIDE WALLS OF HOOD <br />TACK WELD TO HOOD COLLAR <br />1" <br />1" <br />METAL PLATE COLLAR CONTINOUS <br />AROUND VENT PIPE SUPPLIED BY <br />POWER VENT SUPPLIER <br />1 1/2" <br />PER MANUF. REQ. <br />EXTERIOR CEMENT PLASTER <br />O/ WIRE LATH O/ W.R.B. <br />FIRESTOP SEALANT ALL AROUND <br />BLDG. PAPER <br />3" ALL AROUND <br />1" H ARCH FROM SPRING <br />POINT <br />HOOD WIDTH 4" <br />HOOD COLLAR <br />22 GA. MTL. HOOD PRIME <br />& PAINT <br />3 1/2" <br />5 1/2" ARCH <br />SPRING POINT TO <br />BOTTOM OF HOOD <br />MILCOR PLASTER STOP <br />BEYOND HOOD <br />MECHANICALLY FASTEN <br />AND SOLDER ALL JOINTS <br />WATERTIGHT TYP. <br />1 <br />- <br />FOR ADDITIONAL INFORMATION SEE DETAILS 4 <br />- <br />VENT PIPE THROUGH COMPOSITION ROOF <br />SCALE: 1 1/2"=1'-0"FILE NAME:SCALE: 1 1/2"=1'-0"FILE NAME: <br />1 LAYER OF 30# ROOF FELT, <br />2 LAYERS IF LESS THAN 4:12 <br />SLOPE. <br />PREFABRICATED PIPE <br />FLASHING W/ GASKET AT TOP <br />& G.S.M. FLASH'G AT BASE. <br />WEATHERBOARD LAP W/ <br />ROOFING. SEAL TO ROOFING <br />W/ ROOFER'S MASTIC - PER <br />CLASS 'A' ROOFING MFG. <br />RECOMMENDATIONS. <br />ROOF FRAM'G <br />(PER STRUCT.) <br />CLASS 'A' COMPOSITION <br />ROOFING <br />VENT PIPE <br />PROVIDE SEALANT IN ROOF <br />SHT'G AROUND VENT <br />INSTRUCTIONS FOR <br />PROPER INSTALLATION <br />REFER TO MANUFACTURER <br />24NOT USED NOT USED <br />HOLD- 829 N <br />Garfield St1/15/2025
The URL can be used to link to this page
Your browser does not support the video tag.