DIVISION 1 - GENERAL REQUIREMENTS <br />SECTION 01 1100 - SUMMARY OF WORK <br />- THIS PROJECT INVOLVES THE RELOCATION OF AN EXISTING IMAGING RADIOLOGY ROOM INTO <br />AN EXISTING CONTROL ROOM. THE EXISTING DRESSING ROOMS WILL BE DEMOLISHED AND <br />REBUILT TO ACCOMODATE THE NEW LOCATION OF THE IMAGING RADIOLOGY ROOM. THE <br />EXISTING LOCATION OF THE IMAGING RADIOLOGY ROOM WILL BE CONVERTED INTO A SHELL <br />SPACE. <br />SECTION 01 2500 - SUBSTITUTIONS <br />- NO PRODUCT MAY BE SUBSTITUTED WITHOUT A PRIOR SUBMITTAL TO AND <br />APPROVAL BY THE ARCHITECT. <br />- PRODUCTS DEEMED NOT AS AN "EQUAL"OR "BETTER" THAN THE SPECIFIED <br />PRODUCT MAY NOT BE SUBSTITUTED. <br />- IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THAT SUCH <br />SUBSTITUTION IS "EQUAL" OR "BETTER" PRIOR TO THE SUBMITTAL. <br />- THE ARCHITECT/ ENGINEER TIME AND FEES REQUIRED TO REVIEW SUBSTITUTIONS <br />SHALL BE PAID BY THE CONTRACTOR. <br />- REVIEW OF SUBSTITUTION SHALL PROCEED UPON AGREEMENT AND APPROVAL OF FEES. <br />- SUBSTITUTION SUBMITTALS CONSTITUTE USING UNNAMED MANUFACTURERS AS <br />'OR EQUALS" <br />- REQUEST FOR SUBSTITUTION SHALL BE REVIEWED BY THE CONTRACTOR AS EQUAL <br />OR BETTER THAN SPECIFIED PRODUCT PRIOR TO SUBMITTAL. <br />- ANY ADDITIONAL COST AS A RESULT OF A SUBSTITUTION SHALL BE BORNE BY THE <br />CONTRACTOR. <br />- UNAUTHORIZED AND UNAPPROVED SUBSTITUTION MATERIAL SHALL BE REMOVED <br />FROM THE SITE AND REPLACED WITH SPECIFIED MATERIAL AT NO ADDITIONAL COST <br />TO THE OWNER. <br />SECTION 01 3119 - PROJECT MEETINGS <br />- UNLESS OTHERWISE REQUIRED BY THE OWNER, BI-WEEKLY CONSTRUCTION <br />MEETINGS SHALL BE ATTENDED BY THE OWNER, ARCHITECT AND CONTRACTOR. <br />- THE CONTRACTOR SHALL WRITE THE MEETING RECORDS. <br />- THE PURPOSE OF THE MEETING INCLUDES PROJECT PROGRESS, REVIEW OF <br />SCHEDULE AND PROJECT VALUES, INSPECTION PROGRESS <br />SECTION 01 3200 - CONSTRUCTION PROGRESS DOCUMENTATION <br />- WITHIN 5 DAYS OF CONTRACT AWARD, THE CONTRACTOR SHALL <br />PROVIDED PROJECT SCHEDULE IDENTIFYING THE FOLLOWING: <br />- SEQUENCE OF CONSTRUCTION <br />- LONG LEAD ITEMS <br />- CONSTRUCTION START DATE <br />- SUBMITTAL DATES <br />- DELIVERY DATES <br />- PERCENT OF COMPLETION <br />- FINAL COMPLETION DATE <br />- THE SCHEDULE SHALL BE REVIEWED AT EACH CONSTRUCTION MEETING <br />SECTION 01 3300 - SUBMITTAL PROCEDURES <br />- CONTRACTOR SHALL LABEL, REVIEW AND NOTE CHANGES ON SUBMITTALS PRIOR TO <br />SUBMITTING TO THE ARCHITECT. <br />- WHEN POSSIBLE, SUBMITTAL SHALL BE SUBMITTED DIGITALLY. IF SUBMITTALS <br />CANNOT BE SUBMITTED DIGITALLY THEN: <br />- SUBMIT SIX (6) SETS OF MANUFACTURER'S PRODUCT DATA, MATERIAL SAFETY <br />DATA SHEETS (MSDS), SHOP DRAWINGS AND SAMPLES FOR ARCHITECT'S APPROVAL. <br />- THE ARCHITECT SHALL PROCESS SUBMITTAL WITHIN 10 (TEN) DAYS OF SUBMITTAL <br />RECEIPT. <br />SECTION 01 3543 - ENVIRONMENTAL PROCEDURES <br />- COMPLY WITH ALL FEDERAL, STATE AND LOCAL REGULATIONS PERTAINING TO <br />WATER, AIR, SOLID WASTE AND NOISE POLLUTION. <br />SECTION 01 4100 - REGULATORY REQUIREMENTS <br />- PERFORM ALL WORK IN ACCORDANCE TO THE LATEST ENFORCED STATUTES, <br />ORDINANCES, LAWS, RULES, CODES, REGULATIONS STANDARDS AND LAWFUL <br />ORDERS OF ALL PUBLIC AUTHORITIES HAVING JURISDICTION. <br />SECTION 01 4500 - QUALITY CONTROL <br />- PRIOR TO INSTALLATION OF ANY WORK, THE CONTRACTOR SHALL INSPECT THE <br />WORK CONDITIONS AND ARRANGE FOR CORRECTION AS REQUIRED OF DEFECTIVE <br />WORKMANSHIP OR MATERIAL THAT MAY AFFECT THE WORK TO BE INSTALLED. <br />- INSTALLATION OF NEW WORK CONSTITUTES ACCEPTANCE THAT THE WORK IN PLACES <br />IS IN PROPER CONDITIONS AND WAIVER OF CLAIM THAT THE WORK IN PLACE IS DEFECTIVE. <br />- ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE ATTACHED <br />SPECIFICATIONS AND CONSTRUCTION DOCUMENTS. <br />- UNLESS OTHERWISE NOTED, ALL MATERIALS AND PRODUCTS SHALL BE NEW AND <br />SPECIFICALLY FOR THE USE IN THIS PROJECT. <br />- UNLESS OTHERWISE NOTED, CONSTRUCTION COST SHALL INCLUDE LABOR AND <br />MATERIALS. <br />SECTION 01 4523 - TESTING AND INSPECTING SERVICES <br />- THE OWNER WILL EMPLOY AND PAY FOR INDEPENDENT TESTING SERVICES. <br />- TESTING AND INSPECTING SERVICES ARE REQUIRED TO VERIFY COMPLIANCE WITH <br />REQUIREMENTS SPECIFIED OR INDICATED. THESE SERVICES DO NOT RELIEVE <br />CONTRACTOR OF RESPONSIBILITY FOR COMPLIANCE WITH THE CONTRACT DOCUMENT <br />REQUIREMENTS. <br />- SPECIFIED TESTS, INSPECTIONS, AND RELATED ACTIONS DO NOT LIMIT CONTRACTOR'S <br />OTHER QUALITY-ASSURANCE AND -CONTROL PROCEDURES THAT FACILITATE <br />COMPLIANCE WITH THE CONTRACT DOCUMENT REQUIREMENTS. <br />- THE CONTRACTOR SHALL REIMBURSE THE OWNER FOR EXCESSIVE INSPECTION <br />COSTS INCURRED BY THE CONTRACTOR'S FAILURE TO COMPLETE THE WORK TIMELY, <br />DEFECTIVE WORK, OVERTIME FOR THE CONTRACTOR'S CONVENIENCE. <br />- THE CONTRACTOR SHALL PAY INSPECTION COSTS FOR ADDITIONAL TESTING DUE TO <br />FAILURE OF MATERIALS, TESTING TO SUBSTANTIATE PROPOSED SUBSTITUTIONS, <br />AND IF APPLICABLE, TESTING TO DETERMINE CODE COMPLIANCE FOR CONCRETE <br />MIX DESIGNS. <br />- THE CONTRACTOR SHALL FURNISH ALL SAMPLES FOR TESTING AS REQUIRED. INITIATE <br />AND COORDINATE ALL TESTING INSPECTIONS AS REQUIRED IN THE CBC, TITLE 24 AND <br />CONSTRUCTION DOCUMENTS. <br />- EACH SIGNED AND CERTIFIED TESTING REPORT SHALL BE COPIED TO THE OWNER, <br />CONTRACTOR AND INSPECTOR OF RECORD. <br />- THE OWNER RESERVES THE RIGHT TO REJECT MATERIALS AND WORKMANSHIP WHICH <br />ARE DEEMED DEFECTIVE OR REQUIRE CORRECTION. <br />SECTION 01 5000 - TEMPORARY FACILITIES <br />- REFER TO THE GENERAL CONDITIONS OR COORDINATE WITH THE OWNER FOR <br />TEMPORARY FACILITIES SUCH AS POWER, WATER, TELEPHONE, SANITARY FACILITIES, <br />FIRE AND SAFETY REQUIREMENTS, GUARDS AND BARRICADES. <br />SECTION 01 6600 - PRODUCT STORAGE AND HANDLING REQUIREMENTS <br />- TRANSPORT, DELIVER, HANDLE AND STORE MATERIALS AND EQUIPMENT AT THE <br />JOB SITE IN A MANNER THAT WILL PREVENT DAMAGE, INCLUDING INTRUSIONS <br />FROM FOREIGN MATTER AND MOISTURE. <br />- MAINTAIN PACKAGED MATERIALS FROM MANUFACTURER'S ORIGINAL CONTAINER <br />UNTIL SUCH TIME WHEN THEY WILL BE INSTALLED. <br />- PROVIDE BARRICADE AND SECURITY AS REQUIRED TO PROTECT PRODUCT. <br />- LOCAL REPRESENTATIVE FOR MAINTENANCE, REPAIR, REPLACEMENT. <br />SECTION 01 7329 - CUTTING AND PATCHING <br />- EXECUTE ALL CUTTING (INCLUDING EXCAVATION ), FITTING OR PATCHING TO MAKE <br />PARTS FIT PROPERLY, TO MATCH EXISTING WHERE APPLICABLE, TO REMOVE AND/ OR <br />REPLACE WORK NOT CONFORMING TO REQUIREMENTS OF THE CONTRACT DOCUMENTS. <br />SECTION 01 7400 - CLEANING AND WASTE MANAGEMENT <br />- PREMISES SHALL BE MAINTAINED CLEAN OF WASTE, DEBRIS AND RUBBISH AT ALL TIMES. <br />- PROVIDE ON-SITE DUMP CONTAINERS DURING THE COURSE OF CONSTRUCTION. <br />- AT FINAL CLEANING REMOVE ALL DEBRIS FROM SITE, REMOVE ALL STAINS, MARKS, <br />PAINT SPOTS, DUST, AND OTHER BLEMISHES AND DEFECTS. <br />- USE ONLY CLEANING MATERIALS RECOMMENDED BY MANUFACTURERS. <br />SECTION 01 7800 - CLOSEOUT SUBMITTALS <br />- SUBMIT WRITTEN NOTICE TO THE ARCHITECT WHEN THE PROJECT IS SUBSTANTIALLY <br />COMPLETED WITH A LIST OF PENDING ITEMS. <br />- THE ARCHITECT WILL THEN MAKE INSPECTION AND DETERMINE THE EXTENT OF THE <br />SUBSTANTIAL COMPLETION. <br />- ANY DEFICIENCIES AND / OR INCOMPLETE WORK SHALL BE CORRECTED PRIOR TO <br />REQUEST OF FINAL COMPLETION. <br />- WHEN THE WORK IS CONSIDERED COMPLETE, THE CONTRACTOR SHALL SUBMIT A <br />WRITTEN CERTIFICATION THAT THE CONTRACT DOCUMENTS HAVE BEEN REVIEWED, <br />THE WORK HAS BEEN INSPECTED AND COMPLETED FOR COMPLIANCE WITH THE <br />CONTRACT DOCUMENTS. <br />- WHEN ACCEPTABLE, THE ARCHITECT WILL REQUEST THE CONTRACTOR TO SUBMIT <br />PROJECT CLOSE-OUT. <br />- FINAL CERTIFICATE OF PAYMENT WILL BE APPROVED AFTER THE CONTRACTOR <br />DELIVERS THE REQUIRED WARRANTIES / GUARANTEES, FINAL CLEAN UP, PROJECT <br />RECORD DOCUMENTS, OPERATION AND MAINTENANCE MANUALS, WATER PURITY <br />REPORT AND CERTIFICATE OF OCCUPANCY. <br />SECTION 01 78 23 - OPERATION AND MAINTENANCE DATA <br />- THE CONTRACTOR SHALL PROVIDE THE OWNER WITH A BINDER WHICH INCLUDES <br />ALL OPERATION MAINTENANCE MANUALS OF ALL PRODUCTS USED IN THE PROJECT. <br />- DELIVER ALL SPECIAL TOOLS, INSTRUMENTS, ACCESSORIES AND SPARE PARTS <br />FOR THE MAINTENANCE OF ALL PRODUCTS TO THE OWNER. <br />SECTION 01 7836 - WARRANTIES <br />- THE CONTRACTOR SHALL COLLECT ALL WRITTEN WARRANTIES AND GUARANTIES <br />AND GUARANTEES INTO A BOUND BOOK AND DELIVER TO THE ARCHITECT FOR <br />THE OWNER'S FINAL APPROVAL. <br />- ASSEMBLE ALL MANUFACTURERS' WARRANTIES AND GUARANTEES WITH THE <br />OWNER'S NAME AS THE BENEFICIARY , INCLUDING ALL EXTENDED WARRANTIES. <br />- ALL WARRANTEES AND GUARANTEES, OTHER THAN MANUFACTURER'S PRINTED <br />WARRANTEES AND GUARANTEES, SHALL BE SUBMITTED IN THE CONTRACTOR'S, <br />SUB-CONTRACTOR, MATERIALS, SUPPLIER OR MANUFACTURER'S LETTERHEAD, <br />STATING THE FOLLOWING INFORMATION: <br />- WARRANTY / GUARANTEE FOR <br />- NAME OF THE OWNER <br />- CONTRACTOR / SUBCONTRACT / SUPPLIER / MFR'S NAME <br />- CONTACT NAME <br />- STATE LICENSE NO. <br />- LOCAL REPRESENTATIVE FOR MAINTENANCE, REPAIR, REPLACEMENT <br />SECTION 01 7839 - PROJECT RECORD DOCUMENTS <br />- THE CONTRACTOR SHALL MAINTAIN ON SITE A SET OF CONSTRUCTION DOCUMENTS <br />FOR THE PURPOSE OF RECORDING AS-BUILT CONDITIONS. <br />- AT THE END OF THE PROJECT, ALL AS-BUILT DRAWINGS SHALL BE TURNED OVER <br />TO THE ARCHITECT FOR THE PRODUCTION OF RECORD DRAWINGS. <br />- THE ARCHITECT WILL ISSUE TO THE OWNER ONE (1) ELECTRONIC FILE OF THE <br />RECORD DRAWINGS. <br />DIVISION 2 - EXISTING CONDITIONS <br />SECTION 02 4119 - SELECTIVE DEMOLITION <br />- EXAMINE THE AREA AND CONDITIONS WHERE DEMOLITION IS TO OCCUR. <br />- IDENTIFY EXTENT OF SELECTIVE DEMOLITION AND ORGANIZE PLAN FOR DEMOLITION <br />AND REMOVAL. <br />- CORRECT ANY UNSATISFACTORY CONDITIONS PRIOR TO PROCEEDING WITH WORK. <br />- ANY UTILITY SHUT OFF SHALL BE COORDINATED WITH THE OWNER AND NOTIFY THE OWNER <br />IN WRITING A MIN. OF 7 DAYS IN ADVANCE. <br />- MATERIALS RESULTING FROM DEMOLITION THAT ARE NOT WANTED BY THE OWNER <br />BECOME THE PROPERTY OF THE CONTRACTOR, EXCEPT AS FOLLOWS, AND SHALL BE <br />PROMPTLY REMOVED FROM THE PROJECT SITE. STORAGE OR SALE OF REMOVED <br />MATERIALS WILL NOT BE PERMITTED ON PROJECT SITE OR WITHIN BUILDING. ITEMS NOT <br />BECOMING PROPERTY OF THE CONTRACTOR INCLUDE, BUT ARE NOT NECESSARILY <br />LIMITED TO THE FOLLOWING: <br />- OWNER HAS FIRST SALVAGE RIGHTS TO FIXTURES, EQUIPMENT, ACCESSORIES <br />AND DOORS REMOVED. ITEMS NOT WANTED BY THE OWNER ARE TO BE <br />DISCARDED OFF-SITE BY CONTRACTOR. <br />- EQUIPMENT BELONGING TO UTILITY OR PUBLIC SERVICE COMPANIES UNLESS <br />ABANDONED BY SUCH COMPANIES. <br />- HIDDEN VALUABLE ITEMS, BURIED ITEMS AND PROPERTY OF THIRD PERSONS. <br />- SALVAGED EQUIPMENT AND MATERIALS NOTED FOR REUSE. <br />OTHER ITEMS INDICATED OR OTHERWISE IDENTIFIED BY OWNER OR ARCHITECT <br />- DURING DEMOLITION OPERATIONS, SHOULD SUSPECT ASBESTOS OR ASBESTOS-CONTAINING <br />MATERIALS, OR OTHER MATERIAL LISTED AS A HAZARDOUS MATERIAL BY THE <br />ENVIRONMENTAL PROTECTION AGENCY (EPA) BE DISCOVERED, NOTIFY THE OWNER AND <br />ARCHITECT AND DISCONTINUE THAT PORTION OF WORK UNTIL FURTHER INSTRUCTED. <br />- CONDUCT DEMOLITION OPERATIONS AND THE REMOVAL OF DEBRIS TO ENSURE MINIMUM <br />INTERFERENCE WITH ROADS, STREETS, WALKS AND ADJACENT FACILITIES. <br />- DO NO CLOSE OR OBSTRUCT STREETS OR WALKS WITHOUT PERMISSION FROM AUTHORITIES <br />HAVING JURISDICTION. PROVIDE FLAGMAN WHERE PUBLIC THOROUGHFARES ARE USED FOR <br />DEBRIS REMOVAL. MAINTAIN THOROUGHFARES FREE OF DIRT AND DEBRIS CAUSED BY <br />DEMOLITION OR HAULING OPERATIONS. <br />- PROTECT PORTIONS OF EXISTING BUILDING INDICATED TO REMAIN. REPAIR OR REPLACE <br />PORTIONS OF BUILDING DAMAGED BY THIS WORK, AT NO ADDITIONAL COST. <br />- PROVIDE TEMPORARY ENCLOSURES OR OTHER METHODS TO LIMIT DUST TRANSMISSION TO <br />ADJACENT AREAS. PROVIDE TEMPORARY NOISE REDUCTION BARRIERS TO SEPARATE <br />WORK AREAS FROM ADJACENT OCCUPIED ARES. <br />- ITEMS TO BE REMOVED AND STORED DURING THE CONSTRUCTION PROCESS AS INDICATED <br />ON THE DRAWINGS SHALL BE STORED AT THE DIRECTION OF THE OWNER. <br />- REMOVE CONSTRUCTION AND FINISHES AS REQUIRED FOR NEW CONSTRUCTION AND <br />TO LIMITS INDICATED ON DRAWINGS. <br />- DURING DEMOLITION, PROTECT ADJOINING WORK FROM DAMAGE. OBSERVE AND MONITOR <br />ADJACENT STRUCTURAL ELEMENTS. STOP WORK AND NOTIFY ARCHITECT FOR <br />INSTRUCTIONS IF CHANGES ARE NOTED. CRACKS OR STRUCTURAL DAMAGE RESULTING <br />FROM DEMOLITION SHALL BE REPAIRED AT NO EXPENSE TO THE OWNER AND TO THE <br />ARCHITECT'S/ENGINEER'S SATISFACTION. <br />- REMOVE EXISTING FINISHES TO LIMITS INDICATED ON THE DRAWINGS WITHOUT DAMAGES <br />TO SUBSTRATES OR ADJACENT SURFACES. INCLUDE REMOVAL OF MECHANICAL AND <br />ELECTRICAL WORK AS APPLICABLE. <br />- REMOVAL OF EXISTING RESILIENT FLOOR COVERINGS: REMOVE FLOOR COVERINGS AND <br />ADHESIVE ACCORDING TO RECOMMENDATIONS IN RFCI'S "RECOMMENDED WORK <br />PRACTICES FOR THE REMOVAL OF RESILIENT FLOOR COVERS." DO NOT USE METHODS <br />REQUIRING SOLVENT-BASED ADHESIVE STRIPPERS. <br />- WHERE WORK IS TO BE CUT OR REMOVED TO ACCOMMODATE NEW WORK, FORM NEAT, <br />UNIFORM AND SMOOTH EDGES OR TERMINATIONS. <br />- PREPARE AN ITEMIZED LIST OF MATERIAL OR EQUIPMENT FOR REUSE OR STORAGE. LIST <br />QUANTITIES, CONDITION AND LOCATION. SUBMIT COPIES TO OWNER WITHIN <br />SEVEN (7) DAYS OF REMOVAL OF ITEM. <br />- REMOVE AND STORE (WHERE NOTED ON DRAWINGS) EXISTING MECHANICAL AND <br />ELECTRICAL EQUIPMENT, INCLUDING PLUMBING FIXTURES, AS INDICATED AND REQUIRED <br />TO COMPLETE WORK. <br />- REMOVE DEBRIS, RUBBISH AND OTHER MATERIALS RESULTING FROM DEMOLITION <br />OPERATIONS FROM PROJECT SITE. DO NOT STOCKPILE DEBRIS ON PROJECT SITE. <br />- BURNING OF REMOVED MATERIALS FROM DEMOLISHED STRUCTURES WILL NOT BE PERMITTED <br />ON THE PROJECT SITE. <br />- COMPLY WITH THE CITY'S REQUIREMENT FOR CONSTRUCTION WASTE RECYCLING. <br />- REPAIR DENTS, CRACKS, SCRATCHES AND HOLES IN EXISTING FINISHES TO REMAIN AS PART <br />OF THE FINISHED WORK. <br />DIVISION 3 - CONCRETE <br />(NO SECTIONS REQUIRED) <br />DIVISION 4 - MASONRY <br />(NO SECTIONS REQUIRED) <br />DIVISION 5 - METALS <br />(NO SECTIONS REQUIRED) <br />SECTION 06 2000 - FINISH CARPENTRY AND MILLWORK <br />PART 1 - GENERAL <br />1.1 SUMMARY: <br />A. WORK OF THIS SECTION INCLUDES FACTORY-FABRICATED WOODWORK AS FOLLOWS: <br />1. PLASTIC LAMINATE-SURFACED COUNTERS, BASE CABINETS, LOW WALLS, <br />WALL CABINETS, AND OPEN SHELVING. <br />2. ROUGH AND FINISHED HARDWARE FOR THIS WORK. <br />1.2 SUBMITTALS: <br />A. GENERAL: IN COMPLIANCE WITH SECTION 01 3300 AND AS SPECIFIED HEREIN. <br />B. SHOP DRAWINGS: SUBMIT FOR ARCHITECTURAL WOODWORK. INDICATE CONSTRUCTION <br />AND INSTALLATION DETAILS, SPECIES AND GRADES OF MATERIALS, FINISHES, AND <br />CABINET HARDWARE SELECTIONS. <br />C. PRODUCT DATA: SUBMIT FOR CABINET HARDWARE AND SIMILAR MANUFACTURED ITEMS. <br />SUBMIT WITH SHOP DRAWINGS. <br />D. SAMPLES; SUBMIT AS FOLLOWS: <br />1. FINISH SAMPLES: SUBMIT ONE SAMPLE OF EACH TYPE OF SELECTED FINISH ON <br />SAMPLES OF SPECIES AND GRADE MATERIAL SPECIFIED. <br />2. HARDWARE ITEMS: SUBMIT IF REQUESTED BY ARCHITECT. SAMPLES WILL BE <br />RETURNED TO SUPPLIER. <br />E. FIRE-RETARDANT TREATMENT CERTIFICATION: SUBMIT FOR ARCHITECT'S INFORMATION <br />ONLY. SUBMIT CERTIFICATION BY TREATING PLANT THAT FIRE RETARDANT TREATMENT <br />MATERIALS COMPLY WITH GOVERNING ORDINANCES AND THAT TREATMENT WILL NOT <br />BLEED THROUGH FINISHED SURFACES. <br />F. AWI CERTIFICATION: SUBMIT AWI QUALITY CERTIFICATION PROGRAM CERTIFICATES <br />INDICATING THAT THE WOODWORK PROVIDED FOR THIS PROJECT COMPLIES WITH THE <br />REQUIREMENTS OF THE AWI GRADES SPECIFIED. <br />1.3 QUALITY ASSURANCE: <br />A. APPLICABLE STANDARDS; COMPLY WITH THE FOLLOWING: <br />1. STANDARDS OF THE FOLLOWING, AS REFERENCED HEREIN: <br />A. AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI). <br />B. APA THE ENGINEERED WOOD ASSOCIATION (APA). <br />C. ASTM INTERNATIONAL (ASTM). <br />D. AMERICAN WOOD PROTECTION ASSOCIATION (AWPA). <br />E. HARDWOOD PLYWOOD AND VENEER ASSOCIATION (HPVA). <br />F. NATIONAL ELECTRIC MANUFACTURERS ASSOCIATION (NEMA). <br />G. NATIONAL FIRE PROTECTION ASSOCIATION (NFPA). <br />H. UNDERWRITERS LABORATORIES, INC., (UL). <br />2. WOOD PRODUCTS; STANDARDS OF THE U.S. DEPARTMENT OF COMMERCE, <br />NATIONAL INSTITUTE OF STANDARDS AND TESTING: <br />A. LUMBER: PS 20-10. <br />B. CONSTRUCTION AND INDUSTRIAL PLYWOOD: PS 1-95 <br />3. STANDARDS FOR ARCHITECTURAL WOODWORK: ARCHITECTURAL WOODWORK <br />INSTITUTE (AWI), "ARCHITECTURAL WOODWORK QUALITY STANDARDS, GUIDE <br />SPECIFICATIONS AND QUALITY CERTIFICATION PROGRAM," 2005 EDITION, <br />HEREIN REFERRED TO AS AWI STANDARDS. WORK SHALL COMPLY WITH <br />APPLICABLE PORTIONS OF AWI STANDARDS. <br />B. GRADE MARKS: IDENTIFY LUMBER AND PLYWOOD BY OFFICIAL GRADE MARK. <br />1. LUMBER: GRADE STAMP SHALL CONTAIN SYMBOL OF GRADING AGENCY, MILL <br />NUMBER OR NAME, GRADE OF LUMBER, SPECIES OR SPECIES GROUPING OR <br />COMBINATION DESIGNATION, RULES UNDER WHICH GRADED WHERE <br />APPLICABLE, AND CONDITION OF SEASONING AT TIME OF MANUFACTURE. <br />2. PLYWOOD: APPROPRIATE GRADE TRADEMARK OF THE APA. INDICATE TYPE, <br />GRADE, CLASS, IDENTIFICATION INDEX AND INSPECTION AND TESTING <br />AGENCY MARK. <br />3. PRESERVATIVE-TREATED WOOD PRODUCTS: PRESERVATIVE-TREATED LUMBER <br />AND PLYWOOD SHALL BEAR THE QUALITY STANDARD STAMP OF THE <br />APPLICATOR, INDICATING PRESERVATIVE TYPE, EXPOSURE CONDITIONS, YEAR <br />OF TREATMENT, TREATMENT PLANT AND TREATMENT SUPERVISING AGENCY. <br />4. FIRE-RETARDANT-TREATED WOOD PRODUCTS: FIRE-RETARDANT-TREATED <br />LUMBER AND PLYWOOD SHALL BEAR UL STAMP OR STAMP OF OTHER <br />APPROVED INDEPENDENT INSPECTION AGENCY, INDICATING TREATMENT <br />TYPE OR NAME, FLAME SPREAD AND TREATMENT PLANT. <br />5. ON COMPONENTS TO BE EXPOSED TO VIEW, GRADE MARKS SHALL BE LOCATED <br />SO AS TO BE CONCEALED IN FINISHED WORK. <br />C. FABRICATOR/INSTALLER QUALIFICATIONS: <br />1. ARCHITECTURAL WOODWORK SHALL BE FABRICATED AND INSTALLED BY A <br />SINGLE MANUFACTURER. <br />A. FABRICATOR/INSTALLER SHALL HAVE AT LEAST FIVE YEARS <br />SUCCESSFUL EXPERIENCE IN THE FABRICATION, FINISHING AND <br />INSTALLATION OF ARCHITECTURAL WOODWORK OF THE TYPE AND <br />QUANTITY REQUIRED AND, IF REQUESTED BY ARCHITECT, SHALL <br />SUBMIT EVIDENCE OF SUCH EXPERIENCE. <br />B. FABRICATOR/INSTALLER SHALL SUBMIT NEUTRAL PREQUALIFICATION <br />FORM FOUND IN APPENDIX IN AWI QUALITY STANDARDS. <br />2. FABRICATOR/INSTALLER SHALL BE A MEMBER OF AWI <br />3. CERTIFICATION SHALL BE EVIDENCED THROUGH APPLICATION OF AWI/QUALITY <br />CERTIFICATION PROGRAM LABELS AND/OR ISSUANCE OF AN AWI LETTER OF <br />LICENSING FOR THE PROJECT. <br />2.6 ADHESIVES: <br />A. ADHESIVES, GENERAL: ADHESIVES SHALL NOT CONTAIN UREA FORMALDEHYDE. <br />B. VOC LIMITS FOR INSTALLATION ADHESIVES: INSTALLATION ADHESIVES SHALL HAVE <br />A VOC CONTENT LESS THAN THE CURRENT VOC CONTENT LIMITS OF SOUTH COAST <br />AIR QUALITY MANAGEMENT DISTRICT (SCAQMD) RULE #1113, ARCHITECTURAL <br />COATINGS, RULES IN EFFECT JANUARY 1, 2004. <br />2.7 FABRICATION: <br />A. GENERAL: <br />1. QUALITY GRADE FOR ARCHITECTURAL WOODWORK SHALL BE AWI PREMIUM <br />GRADE, EXCEPT THAT OPAQUE-FINISHED WOODWORK SHALL BE CUSTOM <br />GRADE. <br />2. FABRICATE ARCHITECTURAL WOODWORK IN ACCORD WITH APPROVED <br />SHOP DRAWINGS. <br />3. SEAL FACES AND EDGES OF MEDIUM DENSITY FIBERBOARD INDICATED TO BE <br />SEALED OR FINISHED. <br />4. PERFORM VENEER OPERATIONS USING HOT PRESS METHOD USING <br />MOISTURE-RESISTANT, FIRE-RETARDANT ADHESIVES. <br />5. SHOP-ASSEMBLE FOR DELIVERY TO SITE IN UNITS EASILY HANDLED AND TO <br />PERMIT PASSAGE THROUGH BUILDINGS OPENINGS. ITEMS WHICH CANNOT <br />BE MANUFACTURED IN ONE PIECE SHALL HAVE JOINTS AT LOGICAL BREAKING <br />POINTS AND SHALL BE SO NOTED ON SHOP DRAWINGS. <br />6. WHEN NECESSARY TO CUT AND FIT ON SITE, PROVIDE MATERIALS WITH <br />AMPLE ALLOWANCE FOR CUTTING. PROVIDE TRIM FOR SCRIBING AND SITE <br />CUTTING. <br />7. SCRIBE, MITER AND ACCURATELY JOIN MEMBERS. <br />8. FINISH WORK SHALL BE SMOOTH, FREE FROM ABRASIOIN, TOOL MARKS, <br />OPEN JOINTS OR RAISED GRAIN ON EXPOSED SURFACES. <br />B. CASEWORK: <br />1. FIT SHELVES, DOORS AND EXPOSED EDGES WITH MATCHING VENEER EDGING. <br />USE ONE PIECE FOR FULL LENGTH ONLY. <br />2. WHERE COUNTERTOPS CAN NOT BE PROVIDED IN SINGLE LENGTH, JOIN <br />JOIN USING COMPRESSION TYPE FASTENERS. <br />3. PROVIDE CUTOUTS FOR PLUMBING FIXTURES, INSERTS, APPLIANCES, OUTLET <br />BOXES, FIXTURES AND FITTINGS. VERIFY LOCATIONS OF CUTOUTS FROM <br />ONSITE DIMENSIONS. SEAL CONTACT SURFACES OF CUT EDGES. <br />PART 3 - EXECUTION <br />3.1 PREPARATION: <br />A. PRIOR TO PRE-INSTALLATION CONFERENCE, EXAMINE SUBSTRATES AND CONDITIONS <br />TO RECEIVE WORK. CHECK THAT FLOORS AND WALL SUBSTRATES ARE LEVEL, PLUMB <br />AND WITHIN TOLERANCES TO RECEIVE WORK SPECIFIED IN THIS SECTION. <br />B. VERIFY MECHANICAL, ELECTRICAL AND BUILDING ITEMS AFFECTING WORK OF THIS <br />SECTION ARE PLACED AND READY TO RECEIVE ARCHITECTURAL WOODWORK. <br />C. DO NOT BEGIN WORK UNTIL UNSATISFACTORY SUBSTRATES OR CONDITIONS HAVE <br />BEEN CORRECTED. <br />D. PRE-INSTALLATION CONFERENCE: <br />1. PRIOR TO BEGINNING WORK, A PRE-INSTALLATION CONFERENCE WILL BE <br />HELD TO REVIEW WORK TO BE ACCOMPLISHED. <br />2. CONTRACTOR, FABRICATOR/INSTALLER AND ARCHITECT SHALL BE PRESENT. <br />3. CONTRACTOR'S SUBMITTALS WILL BE REVIEWED. <br />4. SUBSTRATES AND CONDITIONS UNDER WHICH WOODWORK SHALL BE <br />INSTALLED WILL BE REVIEWED. <br />5. CONTRACTOR SHALL NOTIFY ALL PARTIES AT LEAST SEVEN DAYS PRIOR TO <br />TIME OF CONFERENCE. <br />6. CONTRACTOR SHALL RECORD MINUTES OF MEETING AND DISTRIBUTE TO <br />ALL PARTIES IN ATTENDANCE. <br />3.2 GENERAL WORKMANSHIP: <br />A. INSTALL WOODWORK IN A MANNER CONSISTENT WITH THE SPECIFIED QUALITY GRADE, <br />PLUMB, LEVEL, TRUE AND STRAIGHT WITHIN 1/8" IN 10'-0". SHIM AS REQUIRED USING <br />CONCEALED SHIMS. <br />B. SECURE TO GROUNDS, STRIPPING AND BLOCKING WITH COUNTERSUNK, CONCEALED <br />FASTENERS AND BLIND NAILING. <br />1. USE FIXTURE ATTACHMENTS IN CONCEALED LOCATIONS FOR WALL MOUNTED <br />COMPONENTS. <br />2. SECURE CABINET AND COUNTER BASE TO FLOOR USING ANGLES AND <br />ANCHORAGES. <br />C. SCRIBE AND CUT FOR ACCURATE FIT TO OTHER FINISHED WORK, WITH MAXIMUM GAP <br />OF 1/32". DO NOT USE ADDITION OVERLAY TRIM TO CONCEAL LARGER GAPS. <br />D. USE CONCEALED JOINT FASTENERS TO ALIGN AND SECURE ADJOINING CABINET UNITS <br />AND COUNTERTOPS. <br />E. BEFORE MAKING CUTOUTS, DRILL PILOT HOLES AT CORNERS. <br />F. FINISH WORK SHALL BE SMOOTH, FREE FROM ABRASION, TOOL MARKS, RAISED GRAIN <br />GRADE MARKINGS OR SIMILAR DEFECTS ON EXPOSED SURFACES. <br />G. DISTRIBUTE DEFECTS ALLOWED IN THE QUALITY GRADE SPECIFIED TO THE BEST <br />OVERALL ADVANTAGE WHEN INSTALLING JOB ASSEMBLED WORK. INSTALL WORK IN <br />ACCORD WITH APPROVED SHOP DRAWINGS. <br />H. TOUCH UP MILL FINISHED ITEMS, INCLUDING REFINISHING NECESSITATED BY JOB <br />FITTING OR ATTACHING AND REPAIR OF SCRATCHES AND SIMILAR DAMAGES. TOUCH <br />UP REPAIRS SHALL BE INDISCERNIBLE IN THE FINISHED WORK. <br />3.3 CLEANING AND PROTECTION: <br />A. PROTECT FINISHED AND PREFINISHED SURFACES FROM WORK OF OTHER TRADES. <br />B. PRIOR TO DATE OF SUBSTANTIAL COMPLETION, EXAMINE WORK FOR DAMAGES. <br />REPAIR OR REPLACE SUCH DAMAGED WORK TO ORIGINAL CONDITION. <br />C. CLEAN WOOD, METAL AND ACCESSORY ITEMS USING A NEUTRAL CLEANER. CHECK <br />AND CORRECT OPERATING MECHANISM FOR PROPER OPERATION. ADJUST AND <br />LUBRICATE HINGES, CATCHES AND OTHER OPERATING HARDWARE. <br />END OF SECTION <br />SECTION 06 6OOO - PLASTIC FABRICATIONS <br />PART 1 - GENERAL <br />1.1 RELATED DOCUMENTS: <br />A. DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL AND <br />SUPPLEMENTARY CONDITIONS AND OTHER DIVISION 1 SPECIFICATION SECTION, <br />APPLY TO THIS SECTION. <br />1.2 SUMMARY: <br />A. THIS SECTION INCLUDES THE PLASTIC FABRICATION AS SHOWN AND SPECIFIED IN <br />THE DESCRIBED SYSTEM: <br />1. LOW WALL PARTITIONS <br />B. RELATED SECTIONS INCLUDE THE FOLLOWING: <br />1. SECTION 05 5000 METAL FABRICATIONS <br />2. SECTION 06 2000 FINISH CARPENTRY AND MILLWORK <br />3. SECTION 06 6116 SOLID SURFACING FABRICATIONS <br />1.3 SUBMITTALS: <br />A. GENERAL: SUBMIT THE FOLLOWING IN ACCORDANCE WITH CONDITIONS OF CONTACT <br />AND DIVISION 1 SPECIFICATIONS. <br />B. PRODUCT DATA: SUBMIT MANUFACTURER'S PRODUCT DATA; INCLUDE PRODUCT <br />DESCRIPTION, FABRICATION INFORMATION, AND COMPLIANCE WITH SPECIFIED <br />PERFORMANCE REQUIREMENTS. <br />C. SUBMIT PRODUCT TEST REPORTS FROM A QUALIFIED INDEPENDENT 3RD PARTY <br />TESTING AGENCY INDICATING EACH TYPE AND CLASS OF PANEL SYSTEM COMPLIES <br />WITH THE PROJECT PERFORMANCE REQUIREMENTS, BASED ON COMPREHENSIVE <br />TESTING OF CURRENT PROJECTS. PREVIOUSLY COMPLETED TEST REPORTS WILL BE <br />ACCEPTABLE IF FOR CURRENT MANUFACTURER AND INDICATIVE OF PRODUCTS USED <br />ON THIS PROJECT. <br />1. TEST REPORTS REQUIRED ARE: <br />A. RATE OF BURNING (ASTM D 635). <br />B. SELF-IGNITION TEMPERATURE (ASTM D 1929). <br />C. DENSITY OF SMOKE (ASTM D 2843). <br />D. FLAME SPREAD AND SMOKE DEVELOPED TESTING (ASTM E 84). <br />E. ROOM CORNER BURN TEST (NFPA 286). <br />F. EXTENT OF BURNING (UL 94). <br />G. IMPACT STRENGTH (ASTM D 3763). <br />H. SAFETY GLAZING IMPACT RESISTANCE (ANSI Z97.1-2004). <br />I. UPITT TEST FOR COMBUSTION PRODUCT TOXICITY. <br />J. DYNAMIC ENVIRONMENTAL TESTING (ASTM STANDARDS D 5116 AND <br />D 6670). <br />D. BUILDING APPROVALS: PLASTIC FABRICATIONS ARE TO HAVE BEEN EVALUATED AND <br />MUST BE REGISTERED WITH AND COMPLY TO REQUIREMENTS OF THE FOLLOWING <br />JURISDICTIONS: <br />1. NEW YORK DEPARTMENT OF BUILDINGS (PRODUCT MUST HAVE AN MEA <br />[MATERIALS AND EQUIPMENT ACCEPTANCE] NUMBER) FOR USE AS INTERIOR <br />FINISHES. <br />2. LOS ANGELES DEPARTMENT OF BUILDING AND SAFETY (PRODUCT MUST <br />HAVE A LARR [ LOS ANGELES RESEARCH REPORT] NUMBER) FOR USE AS <br />LIGHT-TRANSMITTING PANELS. <br />E. SHOP DRAWINGS: INCLUDE PLANS, ELEVATIONS, SECTIONS, PANEL DIMENSIONS, <br />DETAILS, AND ATTACHMENTS TO OTHER WORK. <br />D. SAMPLES FOR VERIFICATION: <br />1. SUBMIT MINIMUM 4-INCH BY 4-INCH SAMPLE FOR EACH TYPE, TEXTURE, <br />PATTERN AND COLOR OF SOLID PLASTIC FABRICATION. <br />H. MOCKUPS: <br />1. BUILD MOCKUPS TO VERIFY SELECTIONS MADE UNDER SAMPLE SUBMITTALS <br />AND TO DEMONSTRATE AESTHETIC EFFECTS. <br />2. BUILD MOCKUP OF EACH TYPE OF PLASTIC FABRICATION. <br />3. APPROVED MOCKUPS MAY BECOME PART OF THE COMPLETED WORK IF <br />UNDISTURBED AT TIME OF SUBSTANTIAL COMPLETION. <br />I. MAINTENANCE DATA: SUBMIT MANUFACTURER'S CARE AND MAINTENANCE DATA, <br />INCLUDING CARE, REPAIR AND CLEANING INSTRUCTIONS. INCLUDE IN PROJECT <br />CLOSEOUT DOCUMENTS. <br />1.4 QUALITY ASSURANCE: <br />A. MANUFACTURERS QUALIFICATIONS: <br />1. MATERIALS AND SYSTEMS SHALL BE MANUFACTURED BY A COMPANY <br />CONTINUOUSLY AND REGULARLY EMPLOYED IN THE MANUFACTURE OF <br />SPECIFIED MATERIALS FOR A PERIOD OF AT LEAST FIVE (5) CONSECUTIVE <br />YEARS AND WHICH CAN SHOW EVIDENCE OF THOSE MATERIALS BEING <br />SATISFACTORILY USED ON AT LEAST SIX (6) PROJECTS OF SIMILAR SIZE, <br />SCOPE AND LOCATION. AT LEAST THREE (3) OF THE PROJECTS SHALL HAVE <br />BEEN SUCCESSFUL FOR USE FIVE (5) YEARS OF LONGER. <br />2. MANUFACTURED PANELS MUST BE PRODUCED FROM A MINIMUM OF 40% <br />POST-INDUSTRIAL RECYCLE CONTENT. THIS RECYCLE CONTENT MUST BE <br />CERTIFIED BY A RECOGNIZED 3RD PARTY CERTIFICATION GROUP, SUCH AS <br />SCIENTIFIC CERTIFICATION SYSTEMS (SCS). <br />3. MANUFACTURER MUST OFFER A DOCUMENTED RECLAIM PROCESS THAT WILL <br />TAKE BACK, AT THE MANUFACTURERS COST, PANELS THAT ARE AT THEIR <br />END-OF LIFE CYCLE. <br />1.5 DELIVERY, STORAGE AND HANDLING <br />A. DELIVER PLASTIC FABRICATIONS, SYSTEMS AND SPECIFIED ITEMS IN <br />MANUFACTURER'S STANDARD PROTECTIVE PACKAGING. <br />B. DO NOT DELIVER PLASTIC FABRICATIONS, SYSTEMS, AND COMPONENTS AND <br />ACCESSORIES TO PROJECT SITE UNTIL AREAS ARE READY FOR INSTALLATION. <br />C. STORE MATERIALS IN A FLAT ORIENTATION IN A DRY PLACE THAT IS NOT EXPOSED TO <br />EXTERIOR ELEMENTS. <br />D. HANDLE MATERIALS TO PREVENT DAMAGE TO FINISHED SURFACES. PROVIDE <br />PROTECTIVE COVERINGS TO PREVENT DAMAGE OR STAINING FOLLOWING <br />INSTALLATION FOR DURATION OF PROJECT. <br />E. BEFORE INSTALLING PLASTIC FABRICATIONS, PERMIT THEM TO REACH ROOM <br />TEMPERATURE. <br />1.6 PROJECT CONDITIONS <br />A. ENVIRONMENTAL LIMITATIONS: DO NOT INSTALL SOLID POLYMER FABRICATIONS UNTIL <br />SPACES ARE ENCLOSED AND WEATHERPROOF, AND AMBIENT TEMPERATURES AND <br />HUMIDITY CONDITIONS ARE MAINTAINED AT THE LEVELS INDICATED FOR PROJECT <br />WHEN OCCUPIED FOR ITS INTENDED USE. <br />1.7 WARRANTY: <br />A. MANUFACTURER'S SPECIAL WARRANTY ON PLASTIC FABRICATIONS: MANUFACTURER'S <br />STANDARD FORM AGREEING TO REPAIR OR REPLACE UNITS THAT FAIL IN MATERIAL <br />OR WORKMANSHIP WITHIN THE SPECIFIED WARRANTY PERIOD. <br />B. WARRANTY PERIOD: 2 YEAR AFTER THE DATE OF SUBSTANTIAL COMPLETION. <br />C. THE WARRANTY SHALL NOT DEPRIVE THE OWNER OF OTHER RIGHTS OR REMEDIES <br />THE OWNER MAY HAVE UNDER OTHER PROVISIONS OF THE CONTRACT DOCUMENTS, <br />AND IS IN ADDITION TO AND RUNS CONCURRENT WITH OTHER WARRANTIES MADE BY <br />THE CONTRACTOR UNDER THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. <br />PART 2 - PRODUCTS <br />2.1 MANUFACTURER: <br />A. MANUFACTURER: 3FORM, INC., SALT LAKE CITY, UTAH, USA / TELEPHONE 801-649-2500. <br />2.2 MATERIALS: <br />A. VARIA™ PRODUCED FROM ECORESING™ SHEET. <br />1. BASIS OF DESIGN PRODUCT: THE DESIGN OF PLASTIC FABRICATION IS BASED <br />ON VARIA™ PRODUCED WITH ECORESIN™ AS PROVIDED BY 3FORM, INC. <br />PRODUCTS FROM OTHER MANUFACTURERS MUST BE APPROVED BY THE <br />ARCHITECT OR DESIGNER. <br />2. ENGINEERED POLYESTER RESIN. <br />3. SHEET SIZE: 4' X 8'. <br />C. RESIN PANEL <RS-1> CHARACTERISTICS: <br />1. TYPE: STRATA WATER <br />2. GAUGE: 1/2" <br />3. FINISH: FRONT- SANDSTONE, BACK - SANDSTONE <br />4. EDGES: FLAME-POLISHED ON THE 3 VISIBLE SIDES WITH ROUNDED EDGES <br />5. ORIENTATION: VERTICAL <br />B. RESIN PANEL <RS-2> CHARACTERISTICS: <br />1. TYPE: TRIBE SEAGRASS+PUREWHITE+TRIBE SEAGRASS <br />2. GAUGE: 1/2" <br />3. FINISH: FRONT- SANDSTONE, BACK - SANDSTONE <br />4. EDGES: FLAME-POLISHED ON THE 3 VISIBLE SIDES WHT ROUNDED EDGES <br />5. ORIENTATION: VERTICAL <br />D. INTERLAYER MATERIALS: COMPATIBLE WITH POLYESTERS AND BONDING PROCESS TO <br />CREATE A MONOLITHIC SHEET OF MATERIAL WHEN COMPLETE. <br />E. SHEET MINIMUM PERFORMANCE ATTRIBUTES: <br />1. RATE OF BURNING (ASTM D 635). MATERIAL MUST ATTAIN CC1 RATING FOR A <br />NOMINAL THICKNESS OF 1.5mm (0.060 IN.) AND GREATER. <br />2. SELF-IGNITION TEMPERATURE GREATER THAN 650 DEGREES F. <br />3. DENSITY OF SMOKE (ASTM D 2843). MATERIAL MUST HAVE A SMOKE DENSITY <br />LESS THAN 75%. <br />4. FLAME SPREAD AND SMOKE DEVELOPED TESTING (ASTM E 84). MATERIAL MUST <br />BE ABLE TO MEET A LEVEL OF CLASS A (FLAME SPREAD LESS THAN 25 AND <br />SMOKE LESS THAN 450) AT THICKNESS OF 1". <br />5. ROOM CORNER BURN TEST (NFPA 286). MATERIAL MUST MEET CLASS A <br />CRITERIA AT 1/4" THICKNESS AS DESCRIBED BY THE 2003 INTERNATIONAL <br />BUILDING CODE. <br />6. EXTENT OF BURNING (UL 94). MUST SUBMIT UL CARD. <br />7. IMPACT STRENGTH. MINIMUM IMPACT STRENGTH TEST AS MEASURED BY <br />ASTM D 3763 OF 20 FT. LBS. (FOR DURABILITY, SHIPPING, INSTALLATION, AND <br />USE). <br />8. SAFETY GLAZING. MATERIAL MUST ATTAIN A CLASS A IMPACT RATING IN <br />ACCORDANCE WITH ANSI Z97.1-2004 AT 1/8" THICKNESS. <br />9. UPITT TEST FOR COMBUSTION PRODUCT TOXICITY: PRODUCT MUST BE <br />RECORDED AS "NOT MORE TOXIC THAN WOOD". <br />10. DYNAMIC ENVIRONMENTAL TESTING (ASTM STANDARDS D 5116 AND D 6670). <br />PANELS MUST NOT HAVE DETECTABLE VOC OFF-GASSING AGENTS. <br />11. PANELS MUST BE PRODUCED FROM A MINIMUM OF 40% POST-INDUSTRIAL <br />RECYCLE CONTENT. THIS RECYCLE CONTENT MUST BE CERTIFIED BY A <br />RECOGNIZED 3RD PARTY CERTIFICATION GROUP, SUCH AS SCIENTIFIC <br />CERTIFICATION SYSTEMS (SCS). <br />12. BUILDING APPROVALS: PLASTIC FABRICATIONS ARE TO HAVE BEEN EVALUATED <br />AND MUST BE REGISTERED WITH AND COMPLY TO REQUIREMENTS OF THE <br />FOLLOWING JURISDICTIONS: <br />a. LOS ANGELES DEPARTMENT OF BUILDING AND SAFETY (PRODUCT <br />MUST HAVE <br />A LARR [LOS ANGELES RESEARCH REPORT] NUMBER) FOR USE AS <br />LIGHT-TRANSMITTING PANELS. <br />2.3 FABRICATION: <br />A. GENERAL: FABRICATE PLASTIC FABRICATIONS TO DESIGNS, SIZES AND THICKNESSES <br />INDICATED AND TO COMPLY WITH INDICATED STANDARDS. SIZES, PROFILES AND OTHER <br />CHARACTERISTICS ARE INDICATED ON THE DRAWINGS. <br />B. COMPLY WITH MANUFACTURER'S WRITTEN RECOMMENDATIONS FOR FABRICATION. <br />C. MACHINING: ACCEPTABLE MEANS OF MACHINING ARE LISTED BELOW. ENSURE THAT <br />MATERIAL IS NOT CHIPPED OR WARPED BY MACHINING OPERATIONS. <br />1. SAWING: SELECT EQUIPMENT AND BLADES SUITABLE FOR TYPE OF CUT <br />REQUIRED. <br />2. DRILLING: DRILLS SPECIFICALLY DESIGNED FOR USE WITH PLASTIC PRODUCTS. <br />3. MILLING: CLIMB CUT WHERE POSSIBLE. <br />4. ROUTING. <br />5. TAPPING. <br />D. FORMING: FORM PRODUCTS TO SHAPES INDICATED USING THE APPROPRIATE METHOD <br />LISTED BELOW. COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS. <br />1. COLD BENDING. <br />2. HOT BENDING. <br />3. THERMOFORMING: ACCEPTABLE ONLY ON UNCOATED MATERIAL. <br />4. DRAPE FORMING. <br />5. MATCHED MOLD FORMING. <br />6. MECHANICAL FORMING. <br />E. LAMINATING: LAMINATE TO SUBSTRATES INDICATED USING ADHESIVES AND TECHNIQUES <br />RECOMMENDED BY MANUFACTURER. <br />2.4 MISCELLANEOUS MATERIALS: <br />A. GENERAL: PROVIDE PRODUCTS OF MATERIAL, SIZE, AND SHAPE REQUIRED FOR <br />APPLICATION INDICATES, AND WITH A PROVEN RECORD OF COMPATIBILITY WITH <br />SURFACES <br />CONTACTED IN INSTALLATION. <br />B. CLEANER: TYPE RECOMMENDED BY MANUFACTURER. <br />C. FASTENERS: USE SCREWS DESIGNED SPECIFICALLY FOR PLASTICS. SELF-THREADING <br />SCREWS ARE ACCEPTABLE FOR PERMANENT INSTALLATIONS. <br />D. BONDING CEMENTS: MAY BE ACHIEVED WITH SOLVENTS OR ADHESIVES, SUITABLE FOR <br />USE <br />WITH PRODUCT AND APPLICATION. <br />PART 3 - EXECUTION <br />3.1 EXAMINATION: <br />A. EXAMINE SUBSTRATES, AREAS, AND CONDITIONS WHERE INSTALLATION OF PLASTIC <br />FABRICATIONS WILL OCCUR, WITH INSTALLER PRESENT, FOR COMPLIANCE WITH <br />MANUFACTURER'S REQUIREMENTS. VERIFY THAT SUBSTRATES AND CONDITIONS ARE <br />SATISFACTORY FOR INSTALLATION AND COMPLY WITH REQUIREMENTS SPECIFIED. <br />3.2 INSTALLATION: <br />A. GENERAL: COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS FOR THE <br />INSTALLATION OF PLASTIC FABRICATIONS. <br />B. MANUFACTURER'S SHOP TO FABRICATE ITEMS TO THE GREATEST DEGREE POSSIBLE. <br />C. UTILIZE FASTENERS, ADHESIVES AND BONDING AGENTS RECOMMENDED BY <br />MANUFACTURER FOR TYPE OF INSTALLATION INDICATED. MATERIAL THAT IS CHIPPED, <br />WARPED, HAZED OR DISCOLORED AS A RESULT OF INSTALLATION OR FABRICATION <br />METHODS WILL BE REJECTED. <br />D. INSTALL COMPONENTS PLUMB, LEVEL AND RIGID, SCRIBED TO ADJACENT FINISHES, <br />IN ACCORDANCE WITH APPROVED SHOP DRAWINGS AND PRODUCT DATA. <br />E. FORM FIELD JOINTS MANUFACTURER'S RECOMMENDED PROCEDURES. LOCATE SEAMS <br />IN PANELS SO THAT THEY ARE NOT DIRECTLY IN LINE WITH SEAMS IN SUBSTRATES. <br />3.3 CLEANING AND PROTECTION: <br />A. PROTECT SURFACES FROM DAMAGE UNTIL DATE OF SUBSTANTIAL COMPLETION. REPAIR <br />WORK OR REPLACE DAMAGED WORK, WHICH CANNOT BE REPAIRED TO ARCHITECT'S <br />SATISFACTION. <br />END OF SECTION <br />SECTION 06 6116 - SOLID SURFACING FABRICATIONS <br />PART 1 - GENERAL <br />1.1 REFERENCES: <br />A. APPLICABLE STANDARDS: STANDARDS OF THE FOLLOWING, AS REFERENCED HEREIN: <br />1. AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI). <br />2. ASTM INTERNATIONAL (ASTM). <br />1.2 ACTION SUBMITTALS: <br />A. SHOP DRAWINGS: INDICATE DIMENSIONS, COMPONENT SIZES, FABRICATION DETAILS <br />ATTACHMENT PROVISIONS AND COORDINATION REQUIREMENTS WITH ADJACENT <br />WORK. <br />B. SAMPLES: SUBMIT MINIMUM 6" BY 6" SAMPLES. INDICATE FULL RANGE OF COLOR AND <br />PATTERN VARIATION. APPROVED SAMPLES WILL BE RETAINED AS A STANDARD FOR <br />WORK. <br />C. PRODUCT DATA: INDICATE PRODUCT DESCRIPTION, FABRICATION INFORMATION AND <br />COMPLIANCE WITH SPECIFIED PERFORMANCE REQUIREMENT. <br />1.3 CLOSEOUT SUBMITTALS: <br />A. MAINTENANCE DATA: SUBMIT MANUFACTURER'S CARE AND MAINTENANCE DATA, <br />INCLUDING REPAIR AND CLEANING INSTRUCTIONS. INCLUDE IN PROJECT CLOSEOUT <br />DOCUMENTS. <br />1.4 DELIVERY, STORAGE AND HANDLING: <br />A. DELIVER NO COMPONENTS TO PROJECT SITE UNTIL AREAS ARE READY FOR <br />INSTALLATION. STORE INDOORS. <br />B. HANDLE MATERIALS TO PREVENT DAMAGE TO FINISHED SURFACES. PROVIDE <br />PROTECTIVE COVERINGS TO PREVENT PHYSICAL DAMAGE OR STAINING FOLLOWING <br />INSTALLATION FOR DURATION OF PROJECT. <br />1.5 WARRANTY: <br />A. PROVIDE MANUFACTURER'S WARRANTY AGAINST DEFECTS IN MATERIALS. WARRANTY <br />SHALL PROVIDE FOR REPLACEMENT MATERIAL AND LABOR FOR A PERIOD OF FIVE <br />YEARS, BEGINNING AT DATE OF SUBSTANTIAL COMPLETION. <br />PART 2 - PRODUCTS <br />2.1 CAST ACRYLIC SURFACING MATERIAL: <br />A. ACCEPTABLE PRODUCTS: <br />1. BASIS OF DESIGN: E. I. DU PONT DE NEMOURS & CO., INC., CORIAN. <br />2. INPRO CORPORATION. <br />B. MATERIAL: CAST, 100% ACRYLIC RESIN, SOLID, STRUCTURAL SURFACING MATERIAL. <br />1. MATERIAL SHALL BE THROUGH-PATTERNED AND HOMOGENEOUS. NO <br />COATED MATERIALS NOR NON-HOMOGENEOUS MATERIALS ALLOWED. <br />2. HARDNESS: MINIMUM 55 BARCOL HARDNESS, TESTED IN ACCORD WITH ASTM <br />D2583-07, OR INIMUM 90 ROCKWELL HARDNESS, TESTED IN ACCORD WITH <br />ASTM D785-08. <br />3. TENSILE STRENGTH: MINIMUM 4,200 PSI, TESTED IN ACCORD WITH ASTM <br />D638-10. <br />4. ABRASION RESISTANCE: MAXIMUM 0.4 GRAMS AT 1,000 CYCLES, TESTED IN <br />ACCORD WITH ASTM C501-84(2009). <br />5. FIRE-RESISTANCE: FLAME SPREAD AND SMOKE DEVELOPED MEETING ASTM <br />E84-12C, CLASS I RATING. <br />6. COLOR STABILITY: NO CHANGE IN 200 HOURS, TESTED IN ACCORD WITH <br />NEMA LD3-2005. <br />7. WATER ABSORPTION: MAXIMUM 0.04% FOR 3/4" THICKNESS AND 0.06% FOR <br />1/2" THICKNESS, TESTED IN ACCORD WITH ASTM D570-98(2010). <br />8. FUNGAL RESISTANCE: NO ATTACK WHEN TESTED IN ACCORD WITH ASTM <br />G21-09. <br />9. BACTERIAL RESISTANCE: NO ATTACK WHEN TESTED IN ACCORD WITH ASTM <br />G22-76(1996)(WITHDRAWN 2002). <br />10. IMPACT RESISTANCE: NO FRACTURE WHEN TESTED IN ACCORD WITH NEMA <br />LD3-2005; SECTION 3.3, 144" DROP FOR 1/2" THICKNESS AND 204" DROP FOR <br />3/4" THICKNESS. <br />11. SUPERFICIAL DAMAGE TO A DEPTH OF 0.10" SHALL BE REPAIRABLE BY <br />SANDING AND POLISHING. <br />12. SURFACES SHALL BE UN AFFECTED BY CLASS I REAGENTS AND SHALL BE <br />REPAIRABLE AFTER EXPOSURE TO CLASS II REAGENTS. CLASS I AND II <br />REAGENTS SHALL BE AS IDENTIFIED IN BASIS OF DESIGN MANUFACTURER'S <br />PRODUCT DATA. <br />13. SURFACES AT DRUG COMPOUNDING COUNTER IN THE PHARMACY ARE TO BE <br />CHEMICAL RESISTANT. <br />C. FINISH: MATTE (GLOSS RATING OF 5-20). <br />D. COLOR: AS SELECTED BY ARCHITECT. <br />E. THICKNESS: AS INDICATED IN DRAWINGS. <br />2.2 ACCESSORY PRODUCTS: <br />A. JOINT ADHESIVE: MANUFACTURER'S STANDARD, TWO-PART ADHESIVE KIT TO CREATE <br />INCONSPICUOUS, NON-POROUS JOINTS, WITH A CHEMICAL BOND. <br />B. SEALANT: MANUFACTURER'S STANDARD MILDEW-RESISTANT, USDA/UL RECOGNIZED <br />SILICONE SEALANT IN COLOR MATCHING SURFACING OR CLEAR FORMULATIONS. <br />C. ADHESIVES AND SEALANTS VOC CONTENT: ADHESIVE AND SEALANTS SHALL HAVE A <br />VOC CONTENT LESS THAN THE CURRENT VOC CONTENT LIMITS OF SOUTH COAST <br />AIR QUALITY MANAGEMENT DISTRICT (SCAQMD) RULE #1168, ADHESIVES AND <br />SEALANTS, AMENDED JANUARY 7, 2005. <br />2.3 FABRICATION: <br />A. FACTORY-FABRICATE COMPONENTS TO GREATEST EXTENT PRACTICABLE, TO SIZES <br />AND SHAPES INDICATED, IN ACCORD WITH APPROVED SHOP DRAWINGS. <br />B. FORM JOINTS BETWEEN COMPONENTS USING MANUFACTURER'S STANDARD JOINT <br />ADHESIVE; WITHOUT CONSPICUOUS JOINTS AND WITHOUT VOIDS. ATTACH A 2" WIDE <br />REINFORCING STRIP OF SOLID SURFACING UNDER EACH JOINT. <br />C. PROVIDE FACTORY CUTOUTS FOR PLUMBING FITTINGS AND ACCESSORIES AS INDICATED. <br />D. ROUT AND FINISH COMPONENT EDGES TO A SMOOTH, UNIFORM FINISH. ROUT CUTOUTS <br />AND SAND EDGES SMOOTH. MACHINE RADII AND CONTOURS TO TEMPLATE. REPAIR OR <br />REJECT DEFECTIVE AND INACCURATE WORK. <br />E. EDGE TREATMENT FOR TOPS: AS INDICATED ON DRAWINGS. <br />2.4 SOURCE QUALITY CONTROL: <br />A. ALLOWABLE TOLERANCES: <br />1. VARIATION IN COMPONENT SIZE: + -1/8". <br />2. LOCATION OF OPENINGS: + -1/8" FROM INDICATED LOCATION. <br />PART 3 - EXECUTION <br />3.1 INSTALLATION: <br />A. INSTALL COMPONENTS PLUMB, LEVEL AND RIGID, SCRIBED TO ADJACENT FINISHES, <br />IN ACCORD WITH APPROVED SHOP DRAWINGS AND PRODUCT DATA. <br />B. FORM FIELD JOINTS USING SPECIFIED ADHESIVE, WITH JOINTS INCONSPICUOUS IN <br />FINISHED WORK. <br />C. PROVIDE BACK AND END SPLASHES AS INDICATED. ADHERE TO COUNTERTOPS USING <br />SPECIFIED COLOR-MATCHED SILICONE ADHESIVE. <br />D. KEEP COMPONENTS CLEAN DURING INSTALLATION. REMOVE ADHESIVES, SEALANTS AND <br />OTHER STAINS. KEEP CLEAN UNTIL DATE OF SUBSTANTIAL COMPLETION. REPLACE <br />STAINED COMPONENTS. <br />E. MAKE PLUMBING CONNECTIONS TO SINKS IN ACCORD WITH DIVISION 22, PLUMBING. <br />3.2 PROTECTION: <br />A. PROTECT SURFACES FROM DAMAGE UNTIL DATE OF SUBSTANTIAL COMPLETION. REPAIR <br />OR REPLACE DAMAGED WORK WHICH CANNOT BE REPAIRED. <br />1.4 DELIVERY, STORAGE AND HANDLING: <br />A. DELIVER NO WOODWORK TO PROJECT SITE UNTIL AREAS ARE READY FOR WOODWORK <br />INSTALLATION. <br />B. IMMEDIATELY UPON DELIVERY TO JOB SITE, PLACE WOODWORK INDOORS, PROTECTED <br />FROM WEATHER. <br />C. STORE WOODWORK A MINIMUM OF 6" ABOVE FLOOR ON BLOCKING AND COVER WITH <br />WATERPROOF COVERING. PROVIDE FOR AIR CIRCULATION AND VENTILATION. <br />STORE IN DRY, CONDITIONED SPACE. <br />D. WRAP PREFINISHED WOODWORK IN PROTECTIVE COVERING FOR SHIPPING AND <br />STORAGE. PROTECT FROM SUNLIGHT EXPOSURE. <br />1.5 PROJECT CONDITIONS: <br />A. FIELD MEASUREMENTS: TAKE FIELD MEASUREMENTS TO ASCERTAIN EXACT WOODWORK <br />SIZES. INDICATE EXACT DIMENSIONS ON SHOP DRAWINGS. <br />B. INSTALL NO INTERIOR WOODWORK UNTIL SPACES ARE ENCLOSED, DRY AND <br />CONDITIONED. MAINTAIN TEMPERATURE BETWEEN 55 DEGREES F. AND 80 DEGREES F. <br />FOR 72 HOURS BEFORE BEGINNING INSTALLATION AND AFTERWARDS UNTIL DATE OF <br />SUBSTANTIAL COMPLETION. <br />C. MAINTAIN INTERIOR RELATIVE HUMIDITY AT THE SITE BETWEEN 25% AND 55% BEFORE, <br />DURING, AND AFTER INSTALLATION. <br />PART 2 - PRODUCTS <br />2.1 BASIC MATERIALS: <br />A. GENERAL: PROVIDE MATERIALS THAT COMPLY WITH REQUIREMENTS OF AWI'S QUALITY <br />STANDARD FOR EACH TYPE OF WOODWORK AND QUALITY GRADE SPECIFIED, <br />UNLESS OTHERWISE INDICATED. <br />B. WOOD PRODUCTS: COMPLY WITH THE FOLLOWING: <br />1. RECYCLED CONTENT OF MEDIUM-DENSITY FIBERBOARD AND PARTICLEBOARD: <br />POSTCONSUMER RECYCLED CONTENT PLUS ONE-HALF OF PRECONSUMER <br />RECYCLED CONTENT NOT LESS THAN 30 PERCENT. <br />2. LOW-EMITTING MATERIALS: <br />A. HARDBOARD: AHA A135.4; 1/4" THICKNESS. <br />B. MEDIUM-DENSITY FIBERBOARD: MEETING ANSI A208.2, GRADE MD; <br />CLASS "C" FIRE HAZARD CLASSIFICATION FOR 3/4" THICKNESS, <br />MADE WITH BINDER CONTAINING NO UREA FORMALDEHYDE. <br />C. PARTICLEBOARD: MEETING ANSI A208.1, GRADE M-2 EXTERIOR GLUE; <br />MAT-FORMED, MANUFACTURED OF LONG FIBERED CUTTINGS, <br />WEIGHING MINIMUM OF 40 LBS./CU. FT.; FIRE-RETARDANT-TREATED <br />(FR), MEETING NFPA 101; MOISTURE-RESISTANT (MR); FILLED ON <br />FACES TO BE PAINTED, MADE WITH BINDER CONTAINING NO UREA <br />FORMALDEHYDE. <br />D. PLYWOOD: <br />1) VENEER-FACED PRODUCTS (HARDWOOD PLYWOOD): <br />HPVA HP-1 AND AWPA P17-02, MADE WITH ADHESIVE <br />CONTAINING NO UREA FORMALDEHYDE. <br />2) SOFTWOOD PLYWOOD: DOC PS 1, MEDIUM DENSITY <br />OVERLAY. <br />C. PLASTIC LAMINATES: <br />1. ACCEPTABLE PRODUCTS: <br />A. BASIS OF DESIGN: ARBORITE <br />B. BASIS OF DESIGN: WILSONART INTERNATIONAL, INC., WILSONART <br />2. CONFORMING TO NEMA STANDARD LD3-2005, AS FOLLOWS: <br />A. HORIZONTAL APPLICATIONS: GRADE HGS. <br />B. VERTICAL APPLICATIONS: GRADE VGS. <br />C. CABINET-LINER: GRADE CL-20. <br />D. BACKING SHEET: GRADE BKH, UNDECORATED PLASTIC LAMINATE. <br />E. POST-FORMING APPLICATIONS: GRADE VGP. <br />F. CHEMICAL RESISTANT APPLICATIONS: GRADE VGP. <br />G. SOLID COLOR APPLICATIONS: GRADE HGS. <br />H. PROVIDE ABUSE-RESISTANT LAMINATES FOR EXPOSED PORTIONS <br />OF THE WORK. <br />3. COLORS, TEXTURES AND PATTERNS: AS INDICATED IN FINISH SCHEDULE <br />IN DRAWINGS. <br />2.2 ARCHITECTURAL CABINETS: <br />A. ARCHITECTURAL CABINETS SHALL COMPLY WITH AWI STANDARDS, SECTION 400 <br />B. PLASTIC LAMINATE CLAD CABINETS: <br />1. AWI QUALITY GRADE: CUSTOM. <br />2. PANEL CORE: PARTICLEBOARD OR HARDWOOD PLYWOOD. <br />3. FINISH ON EXPOSED SURFACES: PLASTIC LAMINATE AS SPECIFIED HEREIN. <br />4. FINISH ON SEMI-EXPOSED SURFACES: MELAMINE SPECIFIED HEREIN. <br />5. COMPONENT EDGES: PLASTIC LAMINATE FACED. <br />6. CABINET CONSTRUCTION: FLUSH OVERLAY. <br />C. COUNTER TOPS: <br />1. PLASTIC LAMINATE AND AS SPECIFIED HEREIN. <br />2. CORIAN AS SPECIFIED IN SOLID SURFACING FABRICATIONS SECTION. <br />2.3 MISCELLANEOUS WOODWORK: <br />A. COMPLY WITH AWI STANDARDS AS FOLLOWS: <br />1. SHELVING: SECTION 6, CUSTOM GRADE. <br />2. BACKSPLASH: SECTION 6, CUSTOM GRADE. <br />2.4 TREATED WOOD PRODUCTS: <br />A. PRESSURE-PRESERVATIVE-TREATED WOOD: <br />1. TREATMENT TYPE: WATER-BORNE PRESERVATIVE REGISTERED WITH EPA. <br />2. AWPA STANDARD: <br />A. LUMBER, TIMBER AND PLYWOOD SHALL CONFORM TO APPLICABLE <br />REQUIREMENTS OF AWPA STANDARD U1-07 AND T1-07 FOR <br />SPECIES, PRODUCT AND END USE. <br />B. HANDLING AND CARE OF PRESSURE TREATED WOOD PRODUCTS <br />SHALL CONFORM TO AWPA STANDARD M4-06. <br />C. PRESERVATIVES SHALL CONFORM TO AWPA P5-07 <br />3. PRESERVATIVE RETENTION: AS REQUIRED BY TREATMENT TYPE IN ACCORD <br />WITH AWPA STANDARDS FOR BELOW- OR ABOVE-GROUND USE. <br />4. SEASONING; RE-DRY AFTER TREATMENT TO 19% MAXIMUM MOISTURE <br />CONTENT. <br />5. USE: <br />A. WOOD PRODUCTS IN CONTACT WITH CONCRETE SLABS-ON-GRADE <br />OR FOUNDATIONS. <br />B. NAILERS OR BLOCKING CAST OR BUILT INTO CONCRETE. <br />C. WOOD PRODUCTS IN CONTACT WITH EXTERIOR WALLS. <br />B. INTERIOR FIRE-RETARDANT-TREATED WOOD: <br />1. ACCEPTABLE PRODUCT; SUBJECT TO COMPLIANCE WITH SPECIFIED <br />REQUIREMENTS: <br />A. VIANCE, LLC, D-BLAZE. <br />B. HICKSON CORPORATION, DRICON. <br />C. HOOVER TREATED WOOD PRODUCTS, PYRO-GUARD. <br />2. DESCRIPTION: PRESSURE-IMPREGNATED WITH A CHEMICAL RETARDANT <br />TESTED AND LISTED BY UNDERWRITERS LABORATORIES, INC., (UL). <br />WHEN TESTED IN ACCORD WITH ASTM E84-10B TREATED PRODUCTS <br />SHALL HAVE A FLAME SPREAD OF 25 OR LESS AND SHOW NO EVIDENCE OF <br />SIGNIFICANT PROGRESSIVE COMBUSTION WHEN THE TEST IS CONTINUED <br />FOR AN ADDITIONAL TWENTY MINUTE PERIOD. IN ADDITION, FLAME FRONT <br />SHALL NOT PROGRESS MORE THAN 10'-6" BEYOND CENTERLINE OF <br />BURNERS AT ANY TIME DURING TEST. <br />3. SURFACE BURNING CHARACTERISTICS: F.R.-S RATING IN ACCORD WITH <br />UNDERWRITERS LABORATORIES, INC. (UL). <br />4. AWPA STANDARD: AWPA U1-07, T1-07 AND P17-02 <br />5. SEASONING; KILN-DRIED AFTER TREATMENT TO THE FOLLOWING MAXIMUM <br />MOISTURE CONTENT: <br />A. LUMBER: 19% <br />B. PLYWOOD: 15% <br />6. HYGROSCOPICITY: MAXIMUM 28% EQUILIBRIUM MOISTURE CONTENT WHEN <br />TESTED IN ACCORD WITH ASTM D3201-08A AT 92% RELATIVE HUMIDITY. <br />7. USE: AS REQUIRED BY CODES. <br />2.5 HARDWARE: <br />A. DOORS: <br />1. HINGES: BLUM No. 70T555, 120 DEGREE "CLIP" HINGE. <br />2. PULLS: BECKER #BP225-04, 96 MM WITH ALUMINUM FINISH. <br />3. LOCKS: 5-PIN TUMBLER TYPE BY NATIONAL LOCK WITH MASTER KEY, OR EQUAL <br />B. DRAWERS: <br />1. PULLS: BECKER #BP225-04, 96mm WITH ALUMINUM FINISH. <br />2. DRAWER AND FILE DRAWER SLIDES: KV MODEL #8400, 100 LB. CAPACITY, <br />OR EQUAL. <br />C. SHELVING: <br />1. ADJUSTABLE SHELVING: PRE-BORED 5mm DIAMETER AT 32mm ON CENTER. <br />2. SHELF CLIP: AMCO #11 EARTHQUAKE SAFETY WITH TWO 5mm PIN AT 32mm <br />ON CENTER. <br />D. GROMMETS: D. MOCKETT & CO., INC., SERIES 7G, BLACK COLOR AS SELECTED BY <br />ARCHITECT; LOCATIONS AS INDICATED ON THE DRAWINGS. <br />E. MAGNETIC CATCHES: <br />1. ACCEPTABLE MANUFACTURERS: <br />A. BASIS OF DESIGN: STANLEY WORKS #SP41. <br />B. EPCO, INC. <br />C. SUGATSUNE AMERICA, INC. <br />2. FINISH: FINISH SELECTED BY ARCHITECT. <br />F. RECESSED SHELF STANDARDS AND SUPPORTS: <br />1. ACCEPTABLE MANUFACTURERS: <br />A. BASIS OF DESIGN: KNAPE AND VOGT MFG. CO., #255 STANDARD WITH <br />#256 SUPPORT. <br />B. STANLEY WORKS. <br />C. JOHNSON HARDWARE, INC. <br />D. SUGATSUNE AMERICA, INC. <br />E. HAFELE AMERICA CO. <br />2. TYPE: STEEL. <br />3. FINISH: FINISH AS SELECTED BY ARCHITECT. <br />G. UNDERCARRIAGE DRAWER SLIDES: <br />1. ACCEPTABLE MANUFACTURERS: <br />A. BASIS OF DESIGN: KNAPE AND VOGT MFG. CO., #1500 <br />B. ACCURIDE. <br />C. GRANT HARDWARE CO. <br />2. CAPACITY: 50 LB. <br />H. WIRE MANAGEMENT GROMMET: <br />1. ACCEPTABLE PRODUCTS: <br />A. BASIS OF DESIGN; DOUG MOCKETT & CO., AS INDICATED ON <br />DRAWINGS. <br />B. OUTWATER PLASTICS, INC., #31-2". <br />C. SUGATSUNE AMERICA, INC., #V60. <br />D. HAFELE AMERICA, INC., #429.93.313. <br />2. PROVIDE SET INCLUDING GROMMET, GROMMET CAP AND SLOT COVER; <br />COLOR AS SELECTED BY ARCHITECT FROM MANUFACTURER'S STANDARD <br />SELECTION. <br />I. FASTENERS: PROVIDE BOLTS, NAILS, SCREWS, TOGGLE BOLTS AND SIMILAR <br />FASTENERS AS INDICATED OR REQUIRED TO ATTACH AND SECURE WORK. <br />1. FASTENERS FOR TRIM SHALL BE FINISHING NAILS FOR ATTACHMENT TO WOOD <br />FRAMING, TRIM-HEAD SCREWS FOR ATTACHMENT TO METAL FRAMING. <br />2. MATERIAL AND FINISH FOR NON-PRESSURE TREATED AND FIRE-RETARDANT- <br />TREATED COMPONENTS SHALL BE G90 HOT DIP GALVANIZED STEEL OR TYPE <br />304 STAINLESS STEEL, EXCEPT NAILS SHALL BE HOT DIP GALVANIZED. <br />3. MATERIAL AND FINISH FOR PRESSURE-TREATED COMPONENTS SHALL BE G185 <br />HOT-DIP GALVANIZED STEEL OR TYPE 316L STAINLESS STEEL. <br />DIVISION 7 - THERMAL AND MOISTURE PROTECTION <br />SECTION 07 8400 - FIRESTOPPING <br />PART 1 - GENERAL <br />1.1 SUMMARY: <br />A. RELATED WORK: <br />1. METAL FABRICATIONS. <br />2. ROUGH CARPENTRY. <br />3. JOINT SEALANTS. <br />4. GYPSUM BOARD. <br />5. PLUMBING. <br />6. ELECTRICAL. <br />1.2 SYSTEM PERFORMANCE REQUIREMENTS: <br />A. FIRESTOPPING SYSTEMS SHALL PROVIDE RESISTANCE TO SPREAD OF FIRE, AND <br />PASSAGE OF SMOKE AND OTHER GASES ACCORDING TO REQUIREMENTS INDICATED, <br />INCLUDING BUT NOT LIMITED TO THE FOLLOWING: <br />1. FIRESTOP PENETRATIONS PASSING THROUGH FIRE RESISTANCE RATED WALL <br />AND FLOOR ASSEMBLIES AND OTHER LOCATIONS AS INDICATED ON DRAWINGS. <br />2. PENETRATION FIRESTOPPING SYSTEMS SHALL HAVE BEEN TESTED AND <br />APPROVED BY A THIRD PARTY TESTING AGENCY. <br />3. THROUGH-PENETRATION FIRESTOP SYSTEMS AND DEVICES SHALL RESIST <br />SPREAD OF FIRE, AND PASSAGE OF SMOKE AND OTHER GASES ACCORDING <br />TO REQUIREMENTS INDICATED, INCLUDING BUT NOT LIMITED TO THE <br />FOLLOWING: <br />A. F - RATING SHALL EQUAL OR EXCEED THE RATING OF THE <br />FIRE-RESISTIVE CONSTRUCTION ASSEMBLY THROUGH WHICH THE <br />PENETRATION IS MADE, AS DETERMINED BY ASTM E814-11A, BUT <br />SHALL NOT BE NOT LESS THAN 1-HOUR. <br />B. T- RATING, IN ADDITION TO F-RATING, AT PENETRATIONS LOCATED <br />OUTSIDE OF A WALL CAVITY, SHALL EQUAL FIRE-RESISTIVE RATING <br />OF FLOOR CONSTRUCTION, AS DETERMINED BY ASTM E814-11A, <br />BUT SHALL BE NOT LESS THAN 1-HOUR. <br />C. L - RATING: IN ADDITION TO F AND T RATINGS, FIRESTOPPING SHALL <br />HAVE AN L - RATING, AS DETERMINED BY UL 1479, WHERE INDICATED <br />BY CODE. <br />4. PERIMETER FIRE CONTAINMENT SYSTEMS (EXTERIOR CURTAINWALL/FLOOR <br />INTERSECTION): INTERIOR PERIMETER JOINT SYSTEMS WITH FIRE-RESISTANCE <br />RATINGS INDICATED, AS DETERMINED BY ASTM E2307-10, BUT NOT LESS THAN <br />FIRE-RESISTANCE RATING OF THE FLOOR CONSTRUCTION. <br />5. FIRE-RESISTIVE JOINTS SHALL HAVE FIRE-RESISTANCE RATINGS INDICATED, <br />AS DETERMINED BY UL 2079, BUT NOT LESS THAN FIRE-RESISTANCE RATING <br />OF CONSTRUCTION IN WHICH THE JOINT OCCURS. <br />6. FIRESTOP SYSTEMS USING CEMENTITIOUS FILL MATERIALS SHALL NOT BE <br />PERMITTED. <br />7. SYSTEMS SHALL BE FREE OF ASBESTOS AND VOLATILE ORGANIC COMPOUNDS <br />(VOCs). <br />8. WHERE THERE IS NO SPECIFIC THIRD PARTY TESTED AND CLASSIFIED <br />FIRESTOP SYSTEM AVAILABLE FOR A PARTICULAR FIRESTOP CONFIGURATIONS, <br />OBTAIN FROM FIRESTOP MANUFACTURER, AN ENGINEERING JUDGEMENT (EJ) <br />OR EQUIVALENT FIRE RESISTANCE RATED ASSEMBLY (EFFRA). <br />9. SYSTEMS USED WITHIN OR ADJACENT TO OCCUPIED SPACES SHALL BE FREE <br />OF VOLATILE SOLVENTS, NOXIOUS FUMES AND STRONG ODORS. <br />10. FIRESTOPPING USED FOR THIS PROJECT SHALL BE FMR APPROVED AS LISTED <br />IN THE CURRENT EDITION OF THE FMR BUILDING MATERIAL APPROVAL GUIDE. <br />1.3 ACTION SUBMITTALS: <br />A. SHOP DRAWINGS: SUBMIT DETAILED DRAWINGS OF EACH TYPE AND SIZE PENETRATION <br />THROUGH FIRE-RATED CONSTRUCTION, INDICATING MATERIALS, DIMENSIONS, <br />ASSEMBLY CONSTRUCTION AND RATING. INDICATE THROUGH-PENETRATION FIRESTOP <br />SYSTEM DESIGN LISTINGS, INCLUDING ILLUSTRATIONS FROM A QUALIFIED TESTING AND <br />INSPECTION AGENCY FOR EACH TYPE PENETRATION. <br />B. PRODUCT DATA: SUBMIT PRODUCT DATA AND INSTALLATION INSTRUCTIONS FOR EACH <br />TYPE OF INSTALLATION. INCLUDE INSTALLATION DETAILS AND TEST REPORTS <br />INDICATING THAT FIRESTOPPING MATERIALS, SYSTEMS AND DEVICES MEET SPECIFIED <br />REQUIREMENTS AND DESIGN CRITERIA. INDICATE CLASSIFICATION MARKING OF <br />QUALIFIED TESTING AND INSPECTION AGENCY. <br />1.4 INFORMATIONAL SUBMITTALS: <br />A. CERTIFICATIONS: <br />1. SUBMIT WRITTEN CERTIFICATION THAT FIRESTOP MATERIALS ARE ASBESTOS <br />FREE AND THAT MATERIALS COMPLY WITH LOCAL REGULATIONS. <br />2. SUBMIT WRITTEN CERTIFICATION THAT FIRESTOP MATERIALS COMPLY WITH <br />LOCAL REGULATIONS CONTROLLING USE OF VOLATILE ORGANIC <br />COMPOUNDS (VOCs) AND ARE NON-TOXIC TO BUILDING OCCUPANTS. <br />1.5 QUALITY ASSURANCE: <br />A. APPLICABLE STANDARDS; STANDARDS OF THE FOLLOWING, AS REFERENCED HEREIN: <br />1. ASTM INTERNATIONAL (ASTM). <br />2. FACTORY MUTUAL RESEARCH (FMR) <br />3. NATIONAL FIRE PROTECTION ASSOCIATION (NFPA). <br />4. UNDERWRITERS LABORATORIES, INC. (UL). <br />R <br />No. <br />F <br />LICENSE <br />STATE <br />D <br />O <br />A RCHITECT <br />C AL IFORNIA <br />STEPHE WHITE <br />RENEWAL <br />DATE <br />C-34829 <br />N <br />08/31/25 <br />SHEET TITLE <br />PROJECT <br />FACILITY <br />FAC NO: BLDG NO:FLOOR LEV:SECTION: <br />KP PROJ. NO. <br />MATTERPORT LINK: https://my.matterport.com/show/?m=FW21iEbmuii <br />555 W. Fifth Street Suite 2950 | Los Angeles, CA 90013 USA <br />ARCHITECT <br />CONSULTANT <br />ARCHITECT SEAL CONSULTANT SEAL <br />KAISER FOUNDATION HOSPITALS <br />NATIONAL FACILITIES SERVICES <br />1800 HARRISON STREET OAKLAND, <br />CALIFORNIA 94612 <br />ISSUE / REVISION LOG <br />NO. ISSUED DATE <br />0 <br />5' <br />50 <br />' <br />GR <br />A <br />P <br />H <br />I <br />C <br /> <br />S <br />C <br />A <br />L <br />E <br />S <br />: <br />1/ <br />1 <br />6 <br />" <br /> <br />= <br /> <br />1 <br />' <br />- <br />0 <br />" <br />0 <br />25 <br />' <br />1/ <br />8 <br />" <br /> <br />= <br /> <br />1 <br />' <br />- <br />0 <br />" <br />5' <br />0 <br />12 <br />' <br />1/ <br />4 <br />" <br /> <br />= <br /> <br />1 <br />' <br />- <br />0 <br />" <br />1' <br />0 <br />6' <br />1/ <br />2 <br />" <br /> <br />= <br /> <br />1 <br />' <br />- <br />0 <br />" <br />1' <br />0 <br />2' <br />1- <br />1 <br />/ <br />2 <br />" <br /> <br />= <br /> <br />1 <br />' <br />- <br />0 <br />" <br />0 <br />1' <br />3" <br /> <br />= <br /> <br />1 <br />' <br />- <br />0 <br />" <br />IF <br /> <br />T <br />H <br />I <br />S <br /> <br />S <br />H <br />E <br />E <br />T <br /> <br />I <br />S <br /> <br />N <br />O <br />T <br /> <br />30 <br />" <br />x <br />4 <br />2 <br />" <br />, <br /> <br />I <br />T <br /> <br />I <br />S <br /> <br />A <br /> <br />R <br />E <br />D <br />U <br />C <br />E <br />D <br /> <br />PR <br />I <br />N <br />T <br /> <br />- <br /> <br />S <br />C <br />A <br />L <br />E <br /> <br />AC <br />C <br />O <br />R <br />D <br />I <br />N <br />G <br />L <br />Y <br />AGENCY APPLICATION NUMBER <br />AGENCY APPROVAL STAMP <br />THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS <br />NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION. <br />HZ PROJ. NO. <br />Phone 310.820.4600 | Fax 310.207.4215 <br />www.huitt-zollars.com <br />C:\Users\jpark\Documents\R314412.44 - KP SAN 1st Flr Gen Rad_A22_Central_jhaLWMQW.rvt <br />5/20/2024 10:23:21 AM <br />SOCC 2023 R RAD SAN 1ST FLOOR <br />GEN RAD REPLACEMENT (5284) <br />G0-02 <br />SPECIFICATIONS <br />CA361 1 <br />CAP028060R314412.44 <br />SANTA ANA MEDICAL OFFICES <br />1900 E. 4TH ST. <br />SANTA ANA, CA 92701 <br />CITY SUBMITTAL 04/19/2024 <br />BID SET 05/20/2024 <br />1900 E 4th St - <br />1011190678/9/2024