My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3500 S Bristol St Unit# 100 - 101119098, 20182666 & 40139043 - Plan
PBA
>
Building
>
ProjectDox
>
B
>
Bristol St
>
3500 S Bristol St Unit# 100
>
3500 S Bristol St Unit# 100 - 101119098, 20182666 & 40139043 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/13/2025 6:26:27 AM
Creation date
6/5/2025 7:36:36 AM
Metadata
Fields
Template:
Plan
Permit Number
20182666
40139043
101119098
Full Address
3500 S Bristol St Unit# 100
Street Number
3500
Street Direction
S
Street Name
Bristol
Street Suffix
St
Unit Number
100
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
59
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
1. PROVIDE VIBRATION ISOLATION, FAN MOUNTED SPEED CONTROL, AND DISCONNECT SWITCH. <br />2. PROVIDE GRAVITY BACKDRAFT DAMPER. <br />3. ELECTRIC CONTRACTOR SHALL INTERLOCK FAN OPERATION WITH TIMECLOCK / EMS. <br />FAN SCHEDULE <br />FAN <br />NO. <br />AREA OR <br />SYSTEM <br />SERVED <br />EXTERNAL <br />PRESS. <br />(IN. WG) <br />STARTERLOCATIONCFM FAN <br />RPM MODEL MOUNTING <br />NOTES: <br />HP VOLT/PH DRIVE MOTOR <br />RPM <br />MOTOR DATA <br />WEIGHT <br />(LBS)SONES REMARKS <br />EF-1 CEILING RESTROOMS / JC 300 0.6 TS 1190 CSP-A700-VG INLINE 0.1 115/1 DIRECT -39 1.9 1-4 <br />BASIS OF DESIGN: GREENHECK <br />1. CONTRACTOR SHALL VERIFY WITH EQUIPMENT SUPPLIER EXACT ROUTING AND SIZE OF INSULATED REFRIGERANT PIPING. INSTALL PER MANUFACTURERS RECOMMENDATIONS. <br />2. DIVISION 26 CONTRACTOR TO PROVIDE DISCONNECT SWITCH FOR EVAPORATOR SECTION AND CONDENSING SECTION. <br />3. PROVIDE WITH WALL MOUNTED THERMOSTAT BY UNIT MANUFACTURER. <br />4. PROVIDE SUPPLEMENTAL CONDENSATE PUMP. COORDINATE POWER REQUIREMENTS WITH ELECTRICIAN. <br />CRU / ACCU <br />MARK LOCATION <br />NOTES: <br />TH <br />(MBH)CFM <br />EVAPORATOR SECTION <br />WEIGHT <br />(LBS)EER NOTES <br />CRU-1 / ACCU-1 R-410A 18 10.7 SEE BELOW <br />BASIS OF DESIGN: MITSUBISHIDUCTLESS MINI-SPLIT AC UNIT <br />MODEL NUMBERS SHALL NOT BE CONSIDERED COMPLETE AND MATERIAL SHALL NOT BE ORDERED BY MANUFACTURER AND MODEL NUMBER ONLY. REVIEW THE COMPLETE DESCRIPTION, NOTES AND <br />SPECIFICATIONS TO DETERMINE THE EXACT MATERIAL AND ACCESSORIES TO BE ORDERED. THE MANUFACTURERS LISTED ARE THE BASIS OF DESIGN. <br />TELCO 109 / ROOF <br />SERVICE <br />TELCO 109 <br />MODEL <br />PKA-A18LA / PUY-A18NKA7 <br />REFR. <br />TYPE <br />455 <br />CONDENSING SECTION <br />MCA <br />(A) <br />11 <br />MOCP <br />(A) <br />30 <br />V/PH <br />208/1 <br />AMBIENT <br />(DB) <br />100 30 / 90 <br />SEER <br />19.8 <br />NOM <br />TONS <br />1.5 <br />1. EQUIPMENT SIZED FOR 105°F AMBIENT TEMPERATURE. <br />2. PROVIDE 2 INCH MERV 13, EFFICIENT PLEATED THROWAWAY AIR FILTERS <br />3. DISCONNECT SWITCH FURNISHED BY DIVISION 26 CONTRACTOR. <br />4. PROVIDE SINGLE POINT POWER CONNECTION. <br />5. COORDINATE SIZE OF CONDUCTOR TERMINATION LUGS WITH CONDUCTOR SIZES SHOWN ON ELECTRICAL DRAW <br />6. PROVIDE GFI, WC, 125 VAC, 20 AMP DUPLEX CONVENIENCE RECEPTACLE MOUNTED TO UNIT READY FOR FIELD WIRING WITH A COVER UL LISTED FOR WET AND DAMPER LOCATIONS WHEN IN USE. <br />COORDINATE POWER REQUIREMENTS WITH ELECTRICAL CONTRACTOR. <br />7. SPECIFIED FAN ESP ACCOUNTS FOR DUCT LOSSES EXTERNAL TO UNIT. <br />8. PROVIDE MOTOR HORSEPOWER TO OVERCOME INTERNAL UNIT STATIC PRESSURE DROP PLUS SPECIFIED EXTERNAL STATIC PRESSURE DROP. NOMINAL MOTOR HP SHALL BE NO LARGER THAN THE <br />FIRST AVAILABLE NOMINAL MOTOR SIZE GREATER THAN THE REQUIRED BHP. <br />9. PROVIDE STANDARD INSULATED ROOF CURB WITH MINIMUM HEIGHT OF 12 INCHES. PROVIDE SLOPED CURB IF NEEDED TO MATCH ROOF SLOPE. IN LIEU OF ROOF CURB, CONTRACTOR TO PROVIDE CURB <br />ADAPTER IF SUITABLE IN ORDER TO UTILIZE EXISTING OPENINGS FROM FORMER RTU'S. <br />10. SCHEDULED WEIGHT IS THE MAXIMUM ALLOWABLE OPERATING WEIGHT OF THE EQUIPMENT. <br />11. COOLING COIL LAT IS LEAVING AIR TEMPERATURE OF COIL <br />12. PROVIDE GUARDS TO PROTECT CONDENSER COIL FROM HAIL OR OTHER DAMAGE <br />13. PROVIDE HEATER TO MEET OR EXCEED SCHEDULED MINIMUM MBH OUTPUT. NOMINAL INPUT IS BASED ON LISTED MANUFACTURER'S STANDARD PRODUCT. COORDINATE EQUIPMENT GAS LOAD WITH <br />PLUMBING CONTRACTOR IF DIFFERENT FROM THAT SCHEDULED. MEET MINIMUM EFFICIENCY SCHEDULED. <br />14. PROVIDE WITH HUMIDITROL. <br />15. PROVIDE WITH ECONOMIZER. <br />16. PROVIDE WITH POWERED EXHAUST FAN. <br />MARK LOCATION <br />NOTES: <br />TC <br />(MBH) <br />EAT (F) <br />COOLING DATA <br />WEIGHT <br />(LBS)NOTES <br />RTU-1 <br />BASIS OF DESIGN: LENNOXROOFTOP UNIT SCHEDULE <br />MODEL NUMBERS SHALL NOT BE CONSIDERED COMPLETE AND MATERIAL SHALL NOT BE ORDERED BY MANUFACTURER AND MODEL NUMBER ONLY. REVIEW THE COMPLETE DESCRIPTION, NOTES AND <br />SPECIFICATIONS TO DETERMINE THE EXACT MATERIAL AND ACCESSORIES TO BE ORDERED. THE MANUFACTURERS LISTED ARE THE BASIS OF DESIGN. <br />ROOF <br />SERVICE MODELREFR. <br />TYPE <br />OUTPUT <br />(MBH) <br />ELECTRICAL <br />MCA <br />(A) <br />MOCP <br />(A)V/PHESP <br />(IN)CFM <br />SUPPLY FAN <br />NOM <br />HP <br />SC <br />(MBH)DB WB DB WB <br />LAT (F) <br />(SEER)(EER) <br />MIN EFF NO. <br />STAGES <br />HEATING DATA <br />NO. <br />STAGESDRIVE TYPE <br />O.A. <br />(CFM)INPUT <br />(MBH) <br />R-410A45.9FRONT OF HOUSE LGT048H4E65.0 48.0 25 35 208/3 7601,600 0.75 1.0 39.9 80.0 55.9 17.6 2 212.855.1ECM DIRECT 350 60.0 SEE BELOW <br />NOM <br />TONS <br />4 <br />A. 4-WAY THROW PATTERN UNLESS OTHERWISE INDICATED. <br />B. NECK SIZE SHOWN ON DRAWINGS. PROVIDE BRANCH DUCT TO MATCH NECK SIZE UNLESS OTHERWISE SHOWN ON <br />DRAWINGS. <br />C. PROVIDE BAKED ENAMEL FINISH, COLOR SHALL MATCH CEILING COLOR. REFER TO ARCHITECTURAL DRAWINGS. <br />D. FRAME TYPE TO MATCH CEILING/WALL CONSTRUCTION. COORDINATE WITH ARCHITECTURAL REFLECTED <br />CEILING/WALL PLAN. <br />E. PROVIDE DIFFUSERS,LINEAR SLOTS AND GRILLES WITH NO EXPOSED MOUNTING SCREWS. <br />F. PROVIDE WITH MANUFACTURER'S HOOD SCOOP DEVICE <br />G. FRONT BLADES PARALLEL TO LONG DIMENSION. <br />GRILLE, REGISTER AND DIFFUSER SCHEDULE <br />SYM <br />BOL MODEL NO FACE <br />TYPE <br />MOUNTING <br />LOCATIONSERVICE <br />NOMINAL <br />FACE SIZE <br />(IN) <br />MAX NC <br />MAX PRESS <br />DROP <br />(IN W.C) <br />NOTES: <br />REMARKS <br />BASIS OF DESIGN: TITUS <br />CD-1 SUPPLY PAS 24X24 PERFORATED CEILING 25 0.05 A-E <br />CD-2 SUPPLY PAS 12X12 PERFORATED CEILING 25 0.05 A-E <br />RG-1 RETURN PAR 24X24 PERFORATED CEILING 25 0.05 <br />RG-2 EXHAUST PAR 12X12 PERFORATED CEILING 25 0.05 <br />C-E <br />C-E <br />NOTES: <br />MODEL NUMBERS SHALL NOT BE CONSIDERED COMPLETE AND MATERIAL SHALL NOT BE ORDERED BY MANUFACTURER AND <br />MODEL NUMBERS ONLY. REVIEW THE COMPLETE DESCRIPTION, NOTES AND SPECIFICATIONS TO DETERMINE THE EXACT <br />MATERIAL AND ACCESSORIES TO BE ORDERED. THE MANUFACTURERS LISTED ARE THE BASIS OF DESIGN. <br />1.ALL CONDENSATE PUMPS SHALL BE UL 2043 LISTED FOR PLENUM RATED APPLICATION. <br />2.INSTALL PUMP WITHIN DRAIN PAN. <br />3.PROVIDE PUMP FOR EACH AC UNIT. <br />4.FLOAT-OPERATED CONTROL AND SECOND FLOAT SWITCH TO OPERATE A WARNING SIGNAL AND RELAY TO STOP THE AIR-CONDITIONING UNIT. (PROVIDE REQUIRED RELAY). <br />5.REFER TO FLOOR PLAN FOR APPROXIMATE UNIT LOCATIONS. <br />CP <br />MARK LOCATION <br />NOTES: <br />V/PH <br />MOTOR <br />NOTES <br />CP SEE BELOW <br />BASIS OF DESIGN: LITTLE GIANTCONDENSATE PUMP <br />SEE PLANS <br />EQUIPMENT <br />OR SYSTEM <br />SERVED <br />FCU-1, CRU-1 <br />WATTS <br />20 <br />TYPE GPH <br />HEAD <br />(FT. OF <br />WATER) <br />SHUTOFF <br />(FT. WATER) <br />10451 GAL <br />RESERVOIR <br />MODEL <br />VCC-20-P <br />HP <br />1/30 120/1 93 <br />AMPS <br />1.5 <br />1.DUCT HEATER SHALL BE SLIP IN TYPE <br />2.OVERCURRENT PROTECTION <br />3.SCR CONTROLLER FOR DUCT HEATER <br />4.CONTROL FUSE <br />5.PROVIDE FULL BREAK CONTACTOR <br />6.MAGNETIC CONTACTOR <br />7.UNIT MOUNTED DISCONNECT SWITCH <br />8.AUTOMATIC THERMAL CUTOUT <br />9.CONTROL PANEL NEMA 1 <br />10.PROVIDE ELECTRONIC AIRFLOW SENSOR <br />11.TRANSFORMER WITH TRANSFORMER FUSE <br />12.CONFIGURE EDH-1 TO BE SECOND STAGE OF HEAT (AUXILIARY HEAT) FOR FCU-1. HEAT PUMP OPERATION OF FCU-1 SHALL BE THE PRIMARY SOURCE OF HEATING FOR THE SPACE. <br />EDH <br />MARK LOCATION <br />NOTES: <br />ENT. <br />TEMPERATURE F <br />MAX. P.D. <br />(IN. W.G.)NOTES <br />EDH-1 77 SEE BELOW <br />BASIS OF DESIGN: GREENHECKELECTRICAL HEATING COIL <br />OPEN OFFICE 104 <br />EQUIPMENT <br />OR SYSTEM <br />SERVED <br />FCU-1 87 <br />DUCT SIZE <br />WIDTH <br />(IN.) <br />10 - <br />ELECTRICAL <br />DATA <br />VOLT/PH <br />208/1 <br />INPUT <br />KW <br />NO. OF <br />STEPS CFM AIR VEL. <br />(FPM)LVG.HEIGHT <br />(IN.) <br />DEPHT <br />(IN.) <br />12228451550SCR4 <br />MODEL <br />IDHE <br />OUTSIDE AIR SCHEDULE (ASHRAE 62.1 VENTILATION CALCULATION) <br />SPACE NAME <br />RETAIL SALES 101 <br />SYSTEM <br />ZONE FLOOR <br />AREA <br />Az <br />(SQ FT) <br />ZONE <br />POPULATION <br />Pz <br />(PEOPLE) <br />AREA <br />OUTDOOR <br />AIR RATE <br />Ra <br />(CFM/ SQ FT) <br />PEOPLE <br />OUTDOOR AIR <br />RATE <br />Rp <br />(CFM/ PERSON) <br />OUTDOOR AIR REQUIRED <br />Vbz = (Rp * Pz) + Ra * Az) <br />OUTDOOR <br />AIR <br />PROVIDED <br />(CFM) <br />1330 20 0.12 7.5 309.6 350RTU-1 <br />FCU-1 OPEN OFFICE 104 710 7 0.06 5.0 77.6 100 <br />INVENTORY 105 165 1 14.9 25 <br />MANAGER'S OFFICE 106 90 2 15.4 25 <br />0.06 <br />0.06 <br />5.0 <br />5.0 <br />RTU-1 TOTAL: 350 CFM <br />FCU-1 TOTAL: 150 CFM <br />FCU-1 <br />FCU-1 <br />Mechanical and Electrical Engineers <br />Lilker Associates <br />1001 Avenue of the Americas <br />New York, NY 10018 <br />tel 212.695.1000 <br />fax 212.695.1299 <br />www.lilker.com <br />Kenneth A. Gruskin AIA <br />No. Date Description <br />Consultant: <br />Checked By: <br />Drawn By: <br />Job Address: <br />Drawing Title: <br />Revision Issue: <br />Professional Seal: <br />Drawing Number: <br />2022 Gruskin Architecture + Design, P.C.c <br />This document and the ideas and designs incorporated <br />herein, as an instrument of professional service, is the <br />property of GRUSKIN ARCHITECTURE + DESIGN, P.C., <br />and is not to be used in whole or in part for any other <br />project without the written authorization of GRUSKIN <br />ARCHITECTURE + DESIGN, P.C. <br />North <br />Arrow: <br />Job Name and Number: <br />Date Issued For <br />All Rights Reserved <br />Client: <br />Landlord: <br />Permit: <br />Bid: <br />Construction: <br />0006261 <br />AR91629 <br />5421 <br />9613 <br />39209 <br />10635 <br />2537 <br />11016 <br />5734 <br />ARC 2596 <br />4674 <br />2666 <br />AI 09999 <br />2796 <br />0401 011223 <br />2572 <br />17680 <br />RA-015432-B <br />025528-1 NY <br />TX <br />VA <br />VT <br />MA <br />MT <br />RI <br />PA <br />NY <br />NJ <br />NH <br />MD <br />LA <br />ME <br />KS <br />FL <br />DE <br />CT <br />AZ <br />AL <br />C-1967WY <br />RA011075GA <br />AR10400066IN <br />C-29898CA <br />NM 004168 <br />ARC-400347CO <br />HI AR 11489 <br />PR 19965 <br />OR 4899 <br />SC 6834 <br />NC 9961 <br />13761OH <br />05713IA <br />WV 3727 <br />IL 001-019152 <br />UT 5881358-0301 <br />ID AR-984459 <br />1301052379MI <br />ARC100723DC <br />WI 9900-005MN44326 <br />A-3547NE <br />3811AR <br />5967KY 101374TN <br />MS 3860 <br />1666ND <br />A-2005029740MO <br />a4895OK <br />NV 5521 <br />WA 10344 <br />13167AK <br />SD 11532 <br />C: <br />\ <br />R <br />e <br />v <br />i <br />t <br /> <br />L <br />o <br />c <br />a <br />l <br /> <br />F <br />i <br />l <br />e <br />s <br />\ <br />2 <br />4 <br />0 <br />0 <br />1 <br />3 <br />0 <br />8 <br />_ <br />V <br />E <br />R <br />I <br />Z <br />O <br />N <br />_ <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />_ <br />C <br />A <br />_ <br />ME <br />C <br />H <br />A <br />N <br />I <br />C <br />A <br />L <br />_ <br />v <br />2 <br />3 <br />_ <br />r <br />t <br />r <br />o <br />v <br />a <br />t <br />o <br />T <br />7 <br />V <br />P <br />K <br />. <br />r <br />v <br />t <br />2023-0069 <br />Proposed <br />Store Design <br />for: VERIZON <br />Metro Pointe <br />3500 South Bristol Street <br />Suite 100 <br />Santa Ana, CA 92704 <br />3/15/2024 <br />3/15/2024 <br />MECHANICAL <br />SCHEDULES - 1 OF 2 <br />M.0.3 <br />BS <br />RT <br />36 OF 81 <br />3500 S Bristol St Unit# 100 - <br />101119098, 20182666 & <br />401390437/11/2024