Laserfiche WebLink
© 2020 IRONRIDGE, INC. VERSION 3.2 FLUSH MOUNT INSTALLATION MANUAL - 18 <br />e ND CAPS <br />WIR e CLIPS <br />Wire Clips offer a simple wire management solution. <br />Firmly press Wire Clip into top rail slot. Run electrical wire <br />through open clip. Snap closed once all wires have been <br />placed. <br />Press Clip <br />into Slot <br />Run W <br />i <br />r <br />e <br />Snap Clip <br />Closed <br />End Caps add a completed look and keep debris and <br />pests from collecting inside rail. <br />Firmly press End Cap onto rail end. <br /> ➢End Caps come in sets of left and right. Check that the proper <br />amount of each has been provided. <br />The QBox™ is a flashed junction box with Quick Mount <br />PV patented Elevated Water Seal Technology™, and <br />provides a waterproof pass-through for conduit from <br />the box enclosure to the attic. QBox comes equipped <br />with fasteners to install to the roof deck, and fittings for <br />optional through-the-deck conduit attachment. The QBox <br />is designed to transition or combine up to two (2) strings of <br />conductors utilizing user-supplied wiring components and <br />water-tight fittings. <br />For more information and full instructions please refer to <br />full QMPV Installation Manual. <br /> ➢The QBOX is only certified for use on composition shingle roofs. <br />QMPV QBOX <br />3000 S Sycamore St Unit# <br />A- 201822724/29/2024