Laserfiche WebLink
(E) <br />BED #1 <br />(E) <br />LIVING <br />(N) <br />COMMON AREA <br />(E) <br />KITCHEN <br />(E) <br />BED #2 <br />(E) <br />BATH #2 <br />(E) <br />HALLWAY <br />(E) <br />BATH #1 <br />47'-6" <br />13'-6" <br />29 <br />' <br />- <br />0 <br />" <br />20 <br />' <br />- <br />0 <br />" <br />8'-0"9'-0"5'-0"12'-0" <br />21 <br />' <br />- <br />0 <br />" <br />9' <br />- <br />0 <br />" <br />50 <br />' <br />- <br />0 <br />" <br />14 <br />' <br />- <br />0 <br />" <br />2' <br />- <br />6 <br />" <br />12 <br />' <br />- <br />6 <br />" <br />21 <br />' <br />- <br />0 <br />" <br />10'-0" <br />20'-0" <br />5'-6"12'-0" <br />(E) <br />BED #3 <br />(E) <br />DINING <br />(E <br />) <br /> <br />D <br />O <br />O <br />R <br />(E <br />) <br /> <br />D <br />O <br />O <br />R <br />(E) DOOR <br />(E) DOOR <br />(E <br />) <br /> <br />D <br />O <br />O <br />R <br />(E) 6'0"X3'0" SL. <br />(E) 6'0"X3'0" SL. <br />(E) 3'0"X2'0" SL.(E) 8'0"X3'0" SL. <br />(E) 6'0"X6'8" SL. DR. <br />(E <br />) <br /> <br />6 <br />' <br />0 <br />" <br />X <br />3 <br />' <br />0 <br />" <br /> <br />S <br />L <br />. <br />(E <br />) <br /> <br />6 <br />' <br />0 <br />" <br />X <br />3 <br />' <br />0 <br />" <br /> <br />S <br />L <br />. <br />5' <br />- <br />6 <br />" <br />15 <br />' <br />- <br />6 <br />" <br />8'-6" <br />3'-0"6'-6" <br />1'-3"1'-7" <br />2' <br />- <br />3 <br />" <br />30" <br />1024 S.I. <br />(N) 5'0"X4'0" SL. <br />(N <br />) <br /> <br />5 <br />' <br />0 <br />" <br />X <br />3 <br />' <br />0 <br />" <br /> <br />S <br />L <br />. <br />(N) 3'0"X6'8" <br />ENTRY DOOR <br />(N) 2'6"X6'8" <br />DOOR <br />(N <br />) <br /> <br />2 <br />' <br />6 <br />" <br />X <br />6 <br />' <br />8 <br />" <br />DO <br />O <br />R <br />(N <br />) <br /> <br />3 <br />' <br />0 <br />" <br />X <br />3 <br />' <br />0 <br />" <br /> <br />S <br />L <br />. <br />(N <br />) <br /> <br />3 <br />' <br />0 <br />" <br />X <br />2 <br />' <br />0 <br />" <br /> <br />S <br />L <br />. <br />TE <br />M <br />P <br />. <br /> <br />O <br />B <br />S <br />C <br />U <br />R <br />E <br />(N) LAMINATE <br />SLIDE DOOR <br />7'-0" <br />(N) <br />BED ROOM(N) <br />BATH <br />(N <br />) <br /> <br />M <br />I <br />N <br />I <br /> <br />S <br />P <br />L <br />I <br />T <br />(N) AC CONDENSER W/ <br />SCREEN PAINTED TO <br />MATCH (E) STUCCO COLOR <br />(E) <br />COVERED PORCH <br />12 <br />' <br />- <br />6 <br />" <br />2' <br />- <br />0 <br />" <br />6' <br />- <br />6 <br />" <br />11'-6"8'-6" <br />D <br />W <br />(N <br />) <br /> <br />M <br />I <br />N <br />I <br /> <br />S <br />P <br />L <br />I <br />T <br />SY <br />S <br />T <br />E <br />M <br />NEW TREE AFCI <br />(TYP.) <br />D <br />5/8" TYP "X" DRYWALL BOTH SIDE <br />W/ R-15 SOUND INSULATION, STC 50 <br />SV SV <br />3D <br />3D <br />D <br />D280 CFM HOOD <br />4" DIA. DUCT 14'-0" <br />LENGTH MAX. W/ <br />DAMPER UP TO <br />THE ROOF <br />4" <br />4" <br />3 A2 <br />BATTERY <br />NEW 100A SUBPANEL <br />W/ 225 A BUSBAR <br />EXIST'G 100A ELEC. METER <br />WILL BE UPGRADE TO <br />200A METER <br />A A2 <br />A A2 <br />3'-0" <br />LANDING <br />2'-0" <br />(N) <br />W/H <br />(N) <br /> <br />2 <br />' <br />0 <br />" <br />X <br />6 <br />' <br />8 <br />" <br />10 <br />0 <br /> <br />S <br />. <br />I <br />. <br /> <br />F <br />O <br />R <br />CO <br />M <br />B <br />U <br />S <br />T <br />I <br />O <br />N <br /> <br />A <br />I <br />R <br />PLANTER <br />(N) 22x30 <br />ATTIC <br />ACCESS <br />(E) <br />WASHER <br />(E) <br />DRYER <br />(E) <br />4:12 <br />(E) RIDGE <br />(E) <br />4:12 <br />(E) <br />4:12 <br />(E) <br />4:12 <br />(E <br />) <br /> <br />R <br />I <br />D <br />G <br />E <br />(E <br />) <br />4: <br />1 <br />2 <br />(E <br />) <br />4: <br />1 <br />2 <br />(E) <br />4:12 <br />(E) <br /> <br />V <br />A <br />L <br />L <br />E <br />Y <br />(E) <br /> <br />V <br />A <br />L <br />L <br />E <br />Y <br />(N <br />) <br /> <br />D <br />O <br />R <br />M <br />E <br />R <br />, <br />TY <br />P <br />. <br />4 <br />A2 <br />(N) EAVE <br />VENT, TYP. <br />EXISTING ASPHALT <br />SHINGLE TO REMAIN, TYP. <br />EXISTING ASPHALT <br />SHINGLE TO REMAIN, TYP. <br />EXTEND (N) ROOFING TO <br />MATCH (E) CONDITION, TYP. <br />2'-0" <br />5 <br />3" max. <br />1 2 DEPTH <br />DEPTH <br />3" max. <br />21 <br />5 <br />3 <br />4 <br />4 5 <br />6 <br />63 <br />7 <br />1. NOTCH IN PLATE <br />2.1 3 4 max.IF BORED HOLE <br />EXCEED 1 3 4"IN 2x4 TOP PLATE <br />OR 2.3 4"IN 2x6 TOP PLATE STRAP <br />E/S OF PLATE W/ITEM #3 BELOW <br />3.SIMPSON CS18x14 LONG MTL <br />STRAP,TYP.@ EACH PLATE CUT <br />W/(6) 16d EACH SIDE <br />4. PIPE WHERE OCCURS <br />5. TOP PLATE / SILL PLATE <br />6. ANCHOR BOLTS PER PLANS <br />7.LOCATE ANCHOR BOLTS 5" <br />min./9"max.AWAY FROM NOTCH <br />OR OF PLATE <br />NOTE :IF NOTCH OR HOLE EXCEED 50%OF <br />TOP PLATE WIDTH,STAGGERED @ E/S OF <br />PLATE USE SIMPSON NS NEEDED <br />2x-SILL PLATE <br />CONC. SLAB <br />GYP. BD <br />PLASTER O / HEAVY GAUGE <br />MTL LATH O/MOISTURE BARRIER <br />( O/ PLYWOOD WHERE OCCURS ) <br />26 GA. GALVANIZE MTL WEEP <br />SCREED (CORROSION RESISTANT ) <br />FINISH SLAB <br />FINISH GRADE <br />8" <br />6" <br /> <br />m <br />i <br />n <br />. <br />OR <br /> <br />2 <br />" <br /> <br />A <br />B <br />O <br />V <br />E <br />PA <br />V <br />E <br />D <br /> <br />A <br />R <br />E <br />A <br />21'-0" <br />CONVERTED TO ADU <br />A2 <br />1 <br />(N) F.F. <br />+8" A.F.G. <br />FIN. GRADE <br />(N) STUCCO <br />R-15 WALL <br />INSULATION <br />8' <br />- <br />0 <br />" <br />R-38 <br />INSULATION, <br />TYP. <br />(N) <br />BED ROOM <br />5/8" TYP "X" <br />DRYWALL BOTH SIDE <br />WITH R-15 SOUND <br />INSULATION, STC 50 <br />UP TO ROOF <br />SHEATHING <br />A2 <br />3 <br />(N) T.O.P. <br />+8'-1" <br />1'-6" <br />TYP. <br />(E) <br />BED #2 <br />(N) <br />COMMON AREA <br />NEW 2X6 <br />CEILING JOIST <br />6 <br />2x- FASCIA <br />2x- STUD WALL <br />WATER PROTECTION <br />MEMBRANE ( ICE DAM. <br />PROTECTION WHERE <br />REQUIRED) <br />R-15 INSULATION <br />GYPSUM BOARD <br />W/ SEMI - VAPOR <br />PERMEABLE ( LATEX ) PAINT <br />R-38 INSULATION <br />2x- CEILING JOISTS <br />PER STRUCTURAL PLAN <br />ROOFING RAFTER PER <br />STRUCTURE PLAN <br />ROOFING MATERIAL <br />ROOFING SHEATHING <br />STUCCO <br />A2 <br />FLOOR PLAN <br />NEW JADU <br />12/24/20 <br />AS NOTED <br />D.T. <br />NORTH <br />NEW ADU FLOOR PLAN <br />SCALE: 1/4" = 1'-0" <br />(E) STUD WALL <br />(N) STUDS WALL 2x4 @ 16" O.C. <br />WALL LEGEND <br />(E) STUDS WALL TO BE REMOVED <br />1-HOUR RATED WALL <br />REVISIONS BY <br />Job: <br />Sheet <br />Date: <br />Scale: <br />Drawn: <br />Of Sheets <br />CO <br />N <br />V <br />E <br />R <br />T <br /> <br />( <br />E <br />) <br /> <br />G <br />A <br />R <br />A <br />G <br />E <br /> <br />T <br />O <br /> <br />( <br />N <br />) <br /> <br />A <br />D <br />U <br />PH <br />U <br />O <br />N <br />G <br /> <br />N <br />G <br />O <br />51 <br />3 <br /> <br />S <br />. <br /> <br />K <br />I <br />N <br />G <br /> <br />S <br />T <br />. <br />, <br /> <br />U <br />N <br />I <br />T <br /> <br />2 <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />Du <br />c <br /> <br />V <br />. <br /> <br />T <br />r <br />a <br />n <br />DE <br />S <br />I <br />G <br />N <br />E <br />R <br />16 <br />4 <br />3 <br />6 <br /> <br />V <br />e <br />r <br />n <br />o <br />n <br /> <br />S <br />t <br />. <br />, <br /> <br />F <br />o <br />u <br />n <br />t <br />a <br />i <br />n <br /> <br />V <br />a <br />l <br />l <br />e <br />y <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />8 <br />Ph <br />o <br />n <br />e <br />: <br /> <br />7 <br />1 <br />4 <br />- <br />7 <br />1 <br />3 <br />- <br />3 <br />5 <br />9 <br />7 <br />TOTAL ROOF AREA:420 S.F. <br />VENTILATION REQUIRE:420 : 150 = 2.8 x144 = 404 S.I. <br />* 50% AT EAVE: 404 : 2 = 202 S.I. <br /> PROVIDE:(4) OF 5"x14" EAVE VENT = 4 x 60 = 240 S.I. <br />* 50% AT 3'-0" ABOVE EAVE: 173 S.I. <br /> PROVIDE: (3) OF 24" DIA. DOMER VENT = 3 x 99 = 297 S.I. <br />ATTIC VENTILATION <br />INSTALLATION OF ROOFING SHALL BE IN ACCORDANCE <br />WITH MANUFACTURER'S SPECIFICATIONS <br />ROOF INSTALLATION NOTE EXISTING ROOF PLAN <br />SCALE: 3/16" = 1'-0"NORTH <br />3 <br />2BORE HOLES 1PLASTER WEEP SCREED <br />NOTE: <br />WHERE VENTED RANGE HOOD IS PROVIDE, IT MUST MEET THE CAPTURE <br />EFFICIENCY (CE) OR THE AIR FLOW RATE AS REQUIRED IN THE TABLE <br />150.0.G (ENERGY CODE SECTION 150.0 (o) G) <br />Table 150.0-g Kitchen Range Hood Airflow Rates (cfm) and ASTM E3087 <br />Capture Efficiency (CE) Ratings According to Dwelling Unit Floor Area and <br />Kitchen Range Fuel Type <br />Dwelling Unit Floor <br />Area (ft) <br />Hood Over Electric <br />Range <br />Hood Over Natural Gas <br />Range <br />> 1500 50% ce or 110 cfm 70% CE ir 180 cfm <br />> 1000 - 1500 50% ce or 110 cfm 80% CE ir 250 cfm <br />750 - 2000 55% ce or 130 cfm 85% CE ir 280 cfm <br />< 750 65% ce or 160 cfm 85% CE ir 280 cfm <br />SMOKE ALARM NOTE: <br />- UL 217 RATED SMOKE ALARMS. <br />- IN NEW BUILDINGS, SMOKE ALARMS SHALL BE <br />INTERCONNECTED AND HARDWIRED. <br />- UL 2023/2075 RATED CARBON MONOXIDE ALARMS. <br />- IN NEW BUILDING, CARBON MONOXIDE ALARMS <br />SHALL BE INTERCONNECTD. <br />D SWITCH W/ DIMMER <br />HIGH EFFICACY LIGHT <br />VS VACANCY SENSOR SWITCH <br />HIGH EFFICACY RECESSED LIGHT <br />FIXTURE FLUORESCENT W/ PIN BASE <br />WATER-PROOF GFI OUTLET W/ <br />CONDUIT & WIRE DAMP RATE <br />PHOTO CONTROL AND AUTOMATIC <br />GFCI & AFIC COMBINATION <br />OUTLET TAMPERED <br />HIGH EFFICACY EXHAUST FAN ONLY <br />W/50 CFM AIR. FAN MUST BE ENERGY <br />STAR W/ HUMIDISTAT CONTROLLED AND <br />DUCTED TO BUILDING EXTERIOR <br />BATTERY SMOKE DETECTOR <br />ELECTRIC SMOKE DETECTOR W/ CARBON <br />MONOXIDE ALARM COMBINATION <br />BATTERY BACK-UP (U.N.O.) <br />ELECTRIC SMOKE DETECTOR W/ <br />BATTERY BACK-UP (HARD WIRE) <br />REGISTER <br />BATTERY SMOKE DETECTOR W/ CARBON <br />MONOXIDE ALARM COMBINATION <br />SW <br />I <br />T <br />C <br />H <br />1. <br />2. <br />3. <br />4. <br />SWITCH <br />3D 3 WAY SWITCH W/ DIMMER <br />5. <br />6. <br />7. <br />8. <br />OU <br />T <br />L <br />E <br />T <br />AFCI W/ LISTED TAMPERED RESISTANT <br />240V. OUTLET <br />SM <br />O <br />K <br />E <br />9. <br />10. <br />11. <br />12. <br />OUT DOOR LIGHT <br />ALL LUMINARIES MOUNTED TO THE <br />BUILDING OR TO OTHER BUILDINGS ON <br />THE SAME LOT SHALL BE HIGH EFFICACY <br />LUMINARIES AND SHALL BE <br />CONTROLLED BY A PHOTO CONTROL/ <br />MOTION SENSOR COMBINATION (WITH <br />OVERRIDE) SEE 150(k) 3 FOR <br />REQUIREMENTS ADU PORCH <br />CHANDELIER <br />13. <br />14. <br />CEILING FAN <br />4'x6' FLUORESCENT LIGHT <br />15. <br />16. <br />17. <br />18. <br />19. <br />20. <br />21. <br />HOSE BIBB. <br />ALL HOSE BIBS MUST BE HAVE <br />AN APPROVED ANTI-SIPHON <br />DEVICE (CPC 603.4.6) <br />FA <br />N <br />ELECTRICAL LEGEND <br />I.A.Q. FAN 65 CFM <br />15" H. FROM <br />THE BOTTOM <br />OF THE BOX <br />22. <br />23. <br />SECTION AA <br />SCALE: 1/4" = 1'-0" <br />41-HOUR EAVE <br />1-HOUR WALL <br />5HEAT PUMB WATER HEATER DETAIL <br />UP TO ROOF SHEATHING <br />ICC# ESR 1413 <br />6STONE VENEER DETAIL <br />5/8" DRYWALL TYPE "X" <br />UP TO ROOF SHEATHING <br />513 S King St Unit <br />#23/19/2025