ABBREVIATIONS <br />+48"HEIGHT TO CENTERLINE OF DEVICE OR BOTTOM OF LIGHT FIXTURE <br />(D)EXISTING TO BE DEMOLISH <br />(E)EXISTING TO REMAIN <br />(ER)EXISTING TO BE RELOCATED <br />(N)NEW <br />(R)RELOCATED <br />AC AIR CONDITIONING UNIT <br />ACC AIR COOLED CONDENSER <br />AFC AVAILABLE FAULT CURRENT <br />AFD ADAPTIVE FREQUENCY DRIVE <br />AFF ABOVE FINISHED FLOOR <br />AFG ABOVE FINISHED GRADE <br />AFS ABOVE FINISHED SLAB <br />AH, AHU AIR HANDLER, AIR HANDLER UNIT <br />AIC AMPS INTERRUPTING CAPACITY <br />AF CIRCUIT BREAKER FRAME RATING OR DISCONNECT SWITCH FUSE RATING <br />ALSIG ARC REDUCTION, LONG TIME, SHORT TIME, INSTANTANEOUS, GROUND FAULT TRIP <br />AS DISCONNECT SWITCH AMP RATING <br />AT CIRCUIT BREAKER TRIP RATING <br />AMP, AMPS AMPERE, AMPERES <br />ARCH ARCHITECT <br />AWG AMERICAN WIRE GUAGE <br />BCM BRANCH CIRCUIT MONITOR SYSTEM <br />BIL BASIC INSULATION LEVEL <br />CEC CALIFORNIA ELECTRICAL CODE, CURRENT EDITION <br />C CONDUIT <br />CAP CAPACITOR <br />CB CIRCUIT BREAKER OR CONTROL BOX <br />CBC CALIFORNIA BUILDING CODE, CURRENT EDITION <br />CFC CALIFORNIA FIRE CODE, CURRENT EDITION <br />CL CONTINUOUS LOAD <br />CLG CEILING <br />CO CONDUIT ONLY WITH NYLON PULL LINE, CAP AND MARK <br />CRAC COMPUTER ROOM AIR CONDITIONER <br />CU CONDENSING UNIT <br />DB DISTRIBUTION BOARD <br />DF, EDF DRINKING FOUNTAIN <br />DSD DUCT SMOKE DETECTOR <br />EC ELECTRICAL CONTRACTOR <br />EF EXHAUST FAN <br />EG, G EQUIPMENT GROUND <br />EM EMERGECY LIGHT FIXTURE WITH UL 924 LISTED 90 MINUTE BACKUP POWER SOURCE <br />EPO EMERGENCY POWER OFF <br />ESS, BESS ENERGY STORAGE SYSTEM, BATTERY ENERGY STORAGE SYSTEM <br />EVSE ELECTRIC VEHICLE SUPPLY EQUIPMENT (AKA "ELECTRIC VEHICLE CHARGER") <br />FC FAN COIL <br />FBO FURNISHED BY OTHERS <br />FV FIELD VERIFY <br />H HOT, PHASE CONDUCTOR <br />HP HORSEPOWER OR HEAT PUMP <br />HCB HVLS CONTROL BOX WITH INTEGRAL DISCONNECT <br />HVLS HIGH VOLUME LOW SPEED CEILING FAN <br />HZ HERTZ <br />IDF INTERMEDIATE DISTRIBUTION FRAME <br />GC GENERAL CONTRACTOR <br />GF, GFI, GFCI GROUND FAULT CIRCUIT INTERRUPTER <br />GFPE GROUND FAULT PROTECTION FOR EQUIPMENT <br />G, GND GROUND <br />GB GROUND BUS <br />IAW IN ACCORDANCE WITH <br />IG, ISO ISOLATED GROUND <br />KA KILOAMPERES <br />KV KILOVOLTS <br />KVA KILOVOLT AMPERES <br />KVAR KILOVOLT AMPERES REACTIVE <br />KW KILOWATTS <br />LCP LIGHTING CONTROL PANEL <br />LIS LOAD INTERRUPTER SWITCH <br />LT, LTS LIGHT, LIGHTS <br />LTG LIGHTING <br />LO/TO LOCK OUT / TAG OUT PER BUILDING OR OWNER STANDARDS <br />MBP MAINTENANCE BYPASS <br />MC MECHANICAL CONTRACTOR <br />MDF MAIN DISTRIBUTION FRAME <br />ME MECHANICAL OR PLUMBING ENGINEER <br />MGB MAIN GROUND BUS <br />MHE MATERIAL HANDLING EQUIPMENT <br />MTD MOUNTED <br />MTBB MAIN TELEPHONE BACKBOARD <br />MV MEDIUM VOLTAGE <br />N NEUTRAL, GROUNDED CONDUCTOR <br />NL NIGHT LIGHT, ON AT DUSK AND OFF AT DAWN <br />NTS NOT TO SCALE <br />OFCI OWNER FURNISHED, CONTRACTOR INSTALLED <br />P PUMP <br />PC PLUMBING CONTRACTOR <br />PE PROFESSIONAL ENGINEER <br />PB PULL BOX <br />PH PHASE <br />PNL PANEL <br />PV PHOTOVOLTAIC <br />REC, RECEPT RECEPTACLE(S) <br />SE STRUCTURAL ENGINEER <br />SF SQUARE FEET OR SUPPLY FAN <br />SFD SMOKE FIRE DAMPER <br />SLD SINGLE LINE DIAGRAM <br />SWBD SWITCHBOARD <br />SWGR SWITCHGEAR <br />TBB TELEPHONE BACKBOARD <br />TITLE 24, T24 CALIFORNIA ENERGY CODE (TITLE 24 PART 6) <br />TR TRUCK RESTRAINT <br />TYP TYPICAL <br />UG UNDERGROUND <br />UGPS UNDERGROUND PULL SECTION <br />UON UNLESS OTHERWISE NOTED <br />UPS UNINTERRUPTIBLE POWER SUPPLY <br />VA VOLT-AMPS <br />VD VOLTAGE DROP <br />VFD VARIABLE FREQUENCY DRIVE <br />VIF VERIFY IN FIELD <br />VL VERIFY LOCATION <br />W WATTS <br />WHS WAREHOUSE <br />WP WEATHERPROOF OR NEMA 3R AS APPLICABLE <br />XFMR, T TRANSFORMER <br />[XXX]INDICATES MANUFACTURES CIRCUIT BREAKER TYPE <br />PART 1 - GENERAL <br />1.CODE IN EFFECT: 2022 CALIFORNIA ELECTRICAL CODE, HEREAFTER REFERRED TO AS "CODE." <br />2."PROVIDE" INDICATES ITEM FURNISHED, INSTALLED AND CONNECTED. <br />3.THE SPECIFICATIONS AND DRAWINGS ARE INTENDED TO COVER A COMPLETE INSTALLATION OF <br />SYSTEMS. THE OMISSION OF EXPRESSED REFERENCE TO ANY ITEM OF LABOR OR MATERIAL FOR <br />THE PROPER EXECUTION OF THE WORK IN ACCORDANCE WITH PRESENT PRACTICE OF THE <br />TRADE SHALL NOT RELIEVE THE CONTRACTOR FROM PROVIDING SUCH ADDITIONAL LABOR AND <br />MATERIALS. UNLESS OTHERWISE NOTED, THESE SPECIFICATIONS AND NOTES APPLY TO THE <br />SCOPE OF THESE CONSTRUCTION DOCUMENTS ONLY. <br />4.ALL NEW WORK AND MATERIALS IN THE SCOPE OF WORK SHALL BE IN FULL COMPLIANCE WITH <br />THE LATEST AND MOST STRINGENT APPLICABLE CODE OR REGULATION. CONTRACTOR SHALL BE <br />SOLELY AND COMPLETELY RESPONSIBLE FOR ANY ADDITIONAL COSTS FOR MATERIALS OR <br />LABOR TO COMPLY WITH THESE CODES OR REGULATIONS. <br />5.NOTHING ON THE DESIGN DRAWINGS SHALL BE DEEMED AS PERMISSION TO VIOLATE THE <br />LATEST AND MOST STRINGENT APPLICABLE CODE OR REGULATION. <br />6.THE CONTRACTOR SHALL VISIT THE SITE, VERIFY THE EXACT CONDITIONS RELATING TO THE <br />WORK AND SHALL OBTAIN SUCH INFORMATION AS MAY BE NECESSARY TO PRESENT A <br />CONCLUSIVE BID. NO ALLOWANCES SHALL BE MADE FOR ANY EXTRA EXPENSE, DUE TO FAILURE <br />OF THE CONTRACTOR TO MAKE SUCH A FIELD VERIFICATION. BY SUBMITTING A PROPOSAL FOR <br />THE WORK INCLUDED IN THE CONTRACT. THE CONTRACTOR SHALL BE DEEMED TO HAVE MADE <br />THE FIELD VERIFICATION AND ACCEPTS ALL JOB SITE CONDITIONS. <br />7.REFER TO THE DRAWINGS AND SHOP DRAWINGS OF OTHER TRADES FOR ADDITIONAL DETAILS <br />WHICH AFFECT THE PROPER INSTALLATION OF THIS WORK. DIAGRAMS AND SYMBOLS SHOWING <br />ELECTRICAL CONNECTIONS ARE DIAGRAMMATIC ONLY. WIRING DIAGRAMS DO NOT NECESSARILY <br />SHOW THE EXACT PHYSICAL ARRANGEMENT OF THE EQUIPMENT. <br />8.THE DRAWINGS INDICATE DIAGRAMMATICALLY THE DESIRED LOCATIONS OR ARRANGEMENTS OF <br />CONDUIT RUNS, OUTLETS, EQUIPMENT, ETC., AND ARE TO BE FOLLOWED AS CLOSELY AS <br />POSSIBLE. PROPER JUDGMENT MUST BE EXERCISED IN EXECUTING THE WORK SO AS TO <br />SECURE THE BEST POSSIBLE INSTALLATION IN THE AVAILABLE SPACE AND TO OVERCOME LOCAL <br />DIFFICULTIES DUE TO SPACE LIMITATIONS OR INTERFERENCE OF STRUCTURE CONDITIONS <br />ENCOUNTERED. ALL EQUIPMENT SHALL BE LOCATED SUCH THAT CODE REQUIRED CLEARANCES <br />ARE MAINTAINED. <br />9.IF THERE ARE OMISSIONS OR CONFLICTS BETWEEN THE DRAWINGS AND SPECIFICATIONS, <br />CLARIFY THESE POINTS, IN WRITING, WITH THE ARCHITECT BEFORE SUBMITTING BID. <br />10.USE ONLY COMPETENT SKILLED PERSONNEL. PERFORM ALL WORK CONSISTENT WITH THE BEST <br />POSSIBLE TRADE PRACTICES. <br />11.CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, INSURANCE, EQUIPMENT, INSTALLATION, <br />CONSTRUCTION TOOLS, TRANSPORTATION, ETC. FOR A COMPLETE AND PROPERLY OPERATING <br />ELECTRICAL SYSTEM. <br />12.ALL MATERIALS SHALL BE NEW AND OF THE SAME MANUFACTURER FOR EACH CLASS OR GROUP <br />OF EQUIPMENT. MATERIALS SHALL BE LISTED AND LABELED BY UNDERWRITER'S LABORATORIES, <br />AND SHALL BEAR THE INSPECTION LABEL WHERE SUBJECT TO SUCH APPROVAL. MATERIALS <br />SHALL MEET WITH THE APPROVAL OF THE DIVISION OF INDUSTRIAL SAFETY, AND ALL <br />GOVERNING BODIES HAVING JURISDICTION. MATERIALS SHALL BE MANUFACTURED IN <br />ACCORDANCE WITH APPLICABLE STANDARDS ESTABLISHED BY A.N.S.I., U.L., N.E.M.A. AND N.B.F.U. <br />INSTALL PER MANUFACTURERS' RECOMMENDATIONS. IF APPLICABLE, ALL EQUIPMENT SHALL BE <br />APPROVED AND LISTED FOR USE IN THIS CITY. <br />13.SWITCHBOARDS, PANELBOARDS, TERMINAL CABINETS, CIRCUIT BREAKERS, DISCONNECT <br />SWITCHES, STARTERS RELAYS, TIME SWITCHES, CONTACTORS, PUSH-BUTTON CONTROL <br />STATIONS, AND OTHER APPARATUS USED FOR THE OPERATION OR CONTROL OF FEEDERS, <br />CIRCUITS, APPLIANCES, OR EQUIPMENT SHALL BE PROPERLY IDENTIFIED BY MEANS OF <br />DESCRIPTIVE NAMEPLATES OR TAGS PERMANENTLY ATTACHED TO THE APPARATUS AND <br />WIRING. <br />14.CONTRACTOR SHALL SECURE AND PAY FOR ALL NECESSARY BUILDING PERMITS AND FEES. <br />COORDINATE TEMPORARY CONSTRUCTION REQUIREMENTS WITH ALL TRADES PRIOR TO <br />CONSTRUCTION. INCLUDE ALL COSTS IN THE BID. <br />15.THE CONTRACTOR SHALL OBTAIN AN INDEPENDENT TESTING LABORATORY THAT WILL PROVIDE <br />ALL INSTRUMENTATION AND TESTS ON THE ELECTRICAL SYSTEM AND EQUIPMENT AS <br />HEREINAFTER DESCRIBED AND FURTHER DIRECTED BY THE ARCHITECT. THE TEST SHALL BE <br />PERFORMED AFTER THE COMPLETION OF ALL ELECTRICAL SYSTEMS COVERED UNDER THIS <br />SECTION OF THE SPECIFICATIONS. ALL TESTS SHALL BE RECORDED, DOCUMENTED AND <br />SUBMITTED TO THE ENGINEER FOR REVIEW. COST OF ALL TESTING SHALL BE BORNE BY THE <br />CONTRACTOR. <br />16.THE JOB SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR AFTER DATE OF ACCEPTANCE <br />BY OWNER. ANY WORK, MATERIAL OR EQUIPMENT FOUND TO BE FAULTY DURING THAT PERIOD <br />SHALL BE CORRECTED AT ONCE, UPON WRITTEN NOTIFICATION AT THE EXPENSE OF THE <br />ELECTRICAL CONTRACTOR. <br />17.WHERE A CONFLICT OCCURS BETWEEN THIS SPECIFICATION AND OTHER SPECIFICATIONS <br />ISSUED AS A PART OF THE CONTRACT DOCUMENTS, THE MORE STRINGENT REQUIREMENTS <br />SHALL PREVAIL. <br />18.ALL ADDENDA AND CHANGE ORDERS SHALL BE APPROVED BY OWNER. <br />19.CONTRACTOR SHALL SUBMIT 1 COPY OF SHOP DRAWINGS, IN PDF FORMAT, FOR ALL MAJOR <br />PIECES OF ELECTRICAL EQUIPMENT, INCLUDING, BUT NOT LIMITED TO SWITCHBOARDS, <br />PANELBOARDS, TRANSFORMERS, MOTION SENSORS AND ALL LIGHTING FIXTURES. SUBMITTALS <br />SHALL BE MADE TO THE ARCHITECT AS SOON AS IS PRACTICABLE AFTER AWARD OF CONTRACT. <br />CONTRACTOR SHALL NOT ORDER EQUIPMENT UNTIL SUBMITTALS HAVE BEEN RETURNED AND <br />STAMPED "REVIEWED" OR "REVIEWED AND CORRECTED" BY THIS OFFICE. MINIMUM REVIEW TIME <br />IS TWO WEEKS UNLESS SUBSTITUTES HAVE BEEN SUBMITTED, WHICH MAY RESULT IN <br />SIGNIFICANTLY LONGER REVIEW TIME. IN THE EVENT THE CONTRACTOR SUBMITS A <br />SUBSTITUTION, HE SHALL IDENTIFY EACH PROPOSED SUBSTITUTION AND PROVIDE A DETAILED <br />COMPARISON BETWEEN THE SPECIFICATION ITEM AND THE SUBSTITUTION. SIMPLY PROVIDING <br />MANUFACTURES CUT SHEETS WILL NOT BE ACCEPTABLE. THE CONTRACTOR SHALL CONSIDER <br />AND INCLUDE SUBMITTAL REVIEW TIME IN HIS TIMELINE. HOWEVER, NOTHING WITHIN THIS <br />SECTION SHALL BE CONSTRUED AS A GUARANTEED REVIEW TIME. BY BIDDING THESE CONTRACT <br />DOCUMENTS, THE CONTRACTOR AGREES TO HOLD THE OWNER AND ENTIRE DESIGN TEAM <br />HARMLESS FOR ANY COSTS INCURRED AS A RESULT OF ANY SUBMITTAL REVIEW DELAY. <br />20.ALL BROCHURES, OPERATING MANUAL, CATALOGS, SHOP DRAWINGS, "AS-BUILTS", ETC. SHALL <br />BE TURNED OVER TO THE OWNER AT THE COMPLETION OF THE JOB. PROVIDE THE OWNER WITH <br />ONE (1) SET OF COMPLETE ELECTRICAL "AS-BUILT" DRAWINGS INDICATING FINAL <br />EQUIPMENT/DEVICE LOCATIONS, CONDUIT ROUTING, ETC. ALL DEVIATIONS FROM ELECTRICAL <br />DESIGN SHALL BE DOCUMENTED AND SUBMITTED TO ARCHITECT. <br />21.WHERE IT IS NECESSARY TO SHUT OFF UTILITY SERVICES OR CAUSE ANY POWER OR SIGNAL <br />INTERRUPTIONS WHILE THE BUILDING IS OCCUPIED, SCHEDULE ALL OUTAGES OR <br />INTERRUPTIONS WITH THE OCCUPANTS OF THE BUILDING OR AS DIRECTED BY THE OWNER. ALL <br />SUCH OUTAGES OR INTERRUPTIONS SHALL BE INCLUDED IN BID AND SCHEDULED AT THE <br />CONVENIENCE OF THE OCCUPANTS. <br />22.WHERE IT BECOMES NECESSARY TO DRILL INTO OR CUT THROUGH ANY EXISTING FLOORS, <br />WALLS OR CEILINGS TO PERMIT THE INSTALLATION OF ANY WORK UNDER THIS CONTRACT, SUCH <br />CUTTING AND PATCHING SHALL BE PERFORMED BY TRADESMEN EXPERIENCED IN THE WORK <br />REQUIRED. CONTRACTOR SHALL PAY FOR ALL COSTS REQUIRED FOR DRILLING, CUTTING <br />AND/OR REPAIRING. ALL FINISHES SHALL MATCH EXISTING AND/OR NEW ADJACENT SURFACES. <br />PROVIDE X-RAYS AS REQUIRED. <br />23.ALL EXTERIOR EQUIPMENT SHALL BE WEATHERPROOF. <br />24.ALL EQUIPMENT SHALL BE RATED FOR THE ENVIRONMENT IN WHICH IT INSTALLED, INCLUDING <br />BUT NOT LIMITED TO : FREEZERS, COOLERS, CLEAN ROOMS, FOOD PROCESS AREAS, WASH <br />DOWN AREAS, OUTDOORS AND CLASSIFIED AREAS. CONTRACTOR IS RESPONSIBLE FOR <br />PROVIDING THE APPROPRIATELY RATED EQUIPMENT WHETHER SPECIFIED IN THESE DRAWING <br />OR NOT. <br />25.WHERE THE SCOPE OF WORK INCLUDES NEW WORK IN EXISTING SWITCHBOARDS, PROVIDE <br />SEPARATE LINE ITEM COST IN BID TO CLEAN SWITCHBOARD AND RETORQUE LUGS WITHIN <br />SWITCHBOARD TO MEET MANUFACTURES SPECIFICATIONS. <br />26.IT IS UNDERSTOOD AND AGREED THAT THIS CONTRACT DOES NOT CONTEMPLATE THE HANDLING <br />OF ASBESTOS, PCB OR ANY HAZARDOUS WASTE MATERIAL. IF ASBESTOS, PCB OR ANY <br />HAZARDOUS WASTE MATERIAL IS ENCOUNTERED, NOTIFY THE OWNER IMMEDIATELY. DO NOT <br />DISTURB, HANDLE OR ATTEMPT TO REMOVE. <br />27.ALL ELECTRICAL EQUIPMENT SHALL BE BRACED AND ANCHORED PER STATE AND LOCAL SEISMIC <br />REQUIREMENTS. <br />PART 2 - MATERIAL <br />A.PULL BOXES <br />1.SIZES AS INDICATED ON THE DRAWINGS AND IN NO CASE OF LESS SIZE OR MATERIAL THICKNESS <br />THAN REQUIRED BY THE GOVERNING CODE. EXERCISE CARE IN LOCATING UNDERGROUND PULL <br />BOXES TO AVOID INSTALLATION IN DRAIN WATER FLOW AREAS. <br />2.GENERAL PURPOSE SHEET STEEL PULL BOXES: INSTALL ONLY IN DRY PROTECTED LOCATIONS <br />WITH REMOVABLE SCREW COVERS. MANUFACTURER'S STANDARD BAKED ENAMEL FINISH. <br />3.ALL WEATHERPROOF JUNCTION BOXES SHALL BE "FS" TYPE, OTHERS SHALL NOT BE ACCEPTED. <br />4.CONCRETE PULL BOXES: FURNISH COMPLETE WITH PULLING IRONS, HOT-DIP GALVANIZED <br />TRAFFIC COVER WITH HOT-DIP GALVANIZED FRAME AND 4 GALVANIZED CABLE RACKS WITH <br />PORCELAIN BLOCKS. THE BOX TO BE SET ON A PEA GRAVEL BASE 12" THICK AND AS LARGE AS <br />THE BOTTOM. PROVIDE PREFABRICATED PULL BOXES AS MANUFACTURED BY QUIKSET OR <br />BROOKS PRODUCTS. SUBMIT SHOP DRAWINGS FOR APPROVAL. REFER TO DRAWINGS FOR SIZE. <br />PROVIDE BEAD WELD ON COVER TO PULL BOX TO INDICATE SERVICES WITHIN PULL BOX (I.E. - <br />"480/277-VOLT, 3-PHASE, 4-WIRE ELECTRICAL" OR "SIGNAL /TEL /P.A. /CLOCK /FIRE ALARM"). <br />B.SWITCHES <br />1.PROVIDE CIRCUIT SWITCHES TOTALLY ENCLOSED, BAKELITE OR COMPOSITION BASE, TOGGLE <br />TYPE WITH 120/277 VOLT A.C. RATING FOR FULL CAPACITY OR CONTACTS FOR LED, <br />INCANDESCENT, FLUORESCENT, HID, OR MOTOR LOADS AS APPLICABLE. SWITCH RATINGS <br />SHALL BE 20 AMPERE MINIMUM. COLOR SHALL BE WHITE OR AS SELECTED BY ARCHITECT. <br />CONTRACTOR SHALL CONFIRM COLOR WITH ARCHITECT PRIOR TO ORDERING. <br />C.RECEPTACLES <br />1.ALL RECEPTACLES IN FLUSH TYPE OUTLET BOXES SHALL BE INSTALLED WITH A BONDING <br />JUMPER TO CONNECT THE BOX TO THE RECEPTACLE GROUND TERMINAL. GROUNDING <br />THROUGH THE RECEPTACLE MOUNTING STRAPS IS NOT ACCEPTABLE. BONDING JUMPER, SIZED <br />PER CODE, SHALL BE ATTACHED AT EACH OUTLET TO THE BACK OF THE BOX USING DRILLED AND <br />TAPPED HOLES AND WASHER HEAD SCREWS 6-32 OR LARGER (EXCEPT ISOLATED GROUND <br />RECEPTACLES). COLOR SHALL BE WHITE W ITH MATCHING COVER PLATE OR AS SELECTED BY <br />ARCHITECT. CONTRACTOR SHALL CONFIRM COLOR WITH ARCHITECT PRIOR TO ORDERING. <br />RECEPTACLES CONNECTED TO EMERGENCY POWER CIRCUITS SHALL BE RED, ISOLATED <br />GROUND SHALL BE ORANGE. <br />2.DUPLEX CONVENIENCE RECEPTACLES SHALL BE GROUNDING TYPE, 125 VOLT, 20 AMPERE AND <br />SHALL HAVE TWO CURRENT CARRYING CONTACTS AND ONE GROUNDING CONTACT WHICH IS <br />INTERNALLY CONNECTED TO THE FRAME. OUTLET SHALL ACCOMMODATE STANDARD PARALLEL <br />BLADE CAP AND SHALL BE SIDE WIRED. ONLY THESE RECEPTACLES LISTED HEREAFTER SHALL <br />BE USED. <br />3.GROUND FAULT CONVENIENCE RECEPTACLES PROVIDE SEPARATE GROUND FAULT RECEPTACLE <br />AT EACH LOCATION INDICATED ON DRAWINGS. <br />4.WEATHERPROOF RECEPTACLE: GROUND FAULT TYPE DUPLEX RECEPTACLE, MOUNTED IN A <br />FLUSH OR SURFACE OUTLET BOX AS NOTED WITH SPRING DOOR TYPE COVERS. <br />5.SPECIAL OUTLETS SHALL BE AS INDICATED ON THE DRAWINGS. <br />6.FLUSH FLOOR DUPLEX CONVENIENCE RECEPTACLE IN A CAST IRON FLOOR BOX AS HEREIN <br />BEFORE SPECIFIED SHALL BE GROUNDING TYPE, 125 VOLTS, 20 AMPERES, AND SHALL HAVE TWO <br />CURRENT CARRYING CONTACTS AND ONE GROUNDING CONTACT WHICH IS INTERNALLY <br />CONNECTED TO THE FRAME. RECEPTACLE SHALL BE P & S OR HUBBELL #5242, SIERRA #1410 OR <br />LEVITON #5014, WITH STANDARD LENGTH MOUNTING STRAP AS REQUIRED BY THE <br />MANUFACTURER OF FLOOR BOX BEING FURNISHED (OR AS SHOWN ON PLANS). <br />D.DISCONNECTS <br />1.DISCONNECT SWITCHES SHALL BE RATED 600 VOLT A.C., HEAVY DUTY, QUICK-MAKE, <br />QUICK-BREAK, HORSEPOWER RATED, NON-FUSIBLE OR FUSIBLE, CLASS "R", IN NEMA TYPE 1 <br />ENCLOSURE, LOCKABLE WITH NUMBER OF POLES AND AMPERAGE AS INDICATED ON THE <br />DRAWINGS. WHERE ENCLOSURE IS EXPOSED TO WEATHER OR IS INDICATED WP <br />(WEATHERPROOF) SWITCHES SHALL BE NEMA TYPE 3R. <br />2.ALL FUSED DISCONNECT SWITCHES SHALL BE FUSED PER ASSOCIATED EQUIPMENT NAMEPLATE. <br />E.TRANSFORMERS <br />1.TRANSFORMERS SHALL BE COPPER WOUND W/ 80 DEGREE C RISE AND A MINIMUM OF (4) 2 1/2% <br />FULL CAPACITY PRIMARY TAPS. VOLTAGES SHALL BE AS SPECIFIED ON SINGLE LINE. PROVIDE <br />VIBRATION ISOLATORS AT FOUR CORNERS. TRANSFORMERS SHALL BE MOUNTED SUCH THAT <br />ALL MANUFACTURERS AND CODE REQUIRED CLEARANCES ARE MAINTAINED. ALL <br />TRANSFORMERS SHALL BE COMPLETELY ENCLOSED EXCEPT FOR VENTILATING OPENINGS. <br />2.ALL DRY-TYPE TRANSFORMERS, RATED AT 15KVA OR GREATER, SHALL MEET THE ENERGY <br />EFFICIENCY REQUIREMENTS OF THE DOE 2016. <br />3.TRANSFORMERS RATED OVER 112 1/2 KVA SHALL HAVE CLASS 155 OR HIGHER INSULATION <br />SYSTEMS AND BE COMPLETELY ENCLOSED EXCEPT FOR VENTILATING OPENINGS. <br />4.WALL MOUNTED TRANSFORMERS SHALL UTILIZE MANUFACTURES MOUNTING BRACKETS. <br />CONTRACTOR IS RESPONSIBLE TO COORDINATE WITH STRUCTURAL TO INSURE WALL IS <br />CAPABLE OF SUPPORTING TRANSFORMER AND COMPLIES WITH ALL CODES. <br />F.SPARE FUSE CABINETS <br />1.WHERE NEW FUSED SWITCHBOARDS OR FUSED MOTOR CONTROL CENTERS ARE INSTALLED, <br />PROVIDE A CABINET WITH SPARE FUSES NEAR EACH ENCLOSURE. CABINETS SHALL BE AS <br />SPECIFIED FOR "TERMINAL CABINETS" AND SHALL BE OF SUFFICIENT SIZE TO CONTAIN ALL <br />SPARE FUSES SPECIFIED HEREIN. PROVIDE CLIPS (2 PER FUSE) FOR EACH SPARE FUSE. <br />PROVIDE (3) SPARE FUSES FOR EACH TYPE/SIZE ON PROJECT. MOUNT CLIPS IN PLYWOOD <br />BACKBOARD IN CABINET. LABEL CABINET "SPARE FUSES". INCLUDE FUSE PULLER. <br />G.CONDUIT <br />1.ALL CONDUIT SHALL BE UTILIZED AND INSTALLED PER CODE. ALL CONDUIT SHALL BE SUPPORTED <br />AND BRACED PER APPLICABLE CODES WITH PIPE CLAMPS & SUPPORTS, PLUMBERS TAPE SHALL <br />NO BE ACCEPTED. <br />2.ALL CONDUIT SHALL BE CONCEALED FROM VIEW WHEREVER POSSIBLE. <br />3.ALL EXPOSED CONDUIT SHALL BE INSTALLED AT RIGHT ANGLES OR PARALLEL TO WALLS OR <br />STRUCTURES AND SHALL BE INSTALLED IN A CLEAN, WORKMAN LIKE MANNER. CONTRACTOR <br />SHALL PAINT EXPOSED CONDUIT TO MATCH SURROUNDING SURFACE COLOR. CONTRACTOR <br />SHALL OBTAIN PAINT MANUFACTURES NAME AND COLOR NUMBERS FROM ARCHITECT OR <br />OWNERS REPRESENTATIVE. <br />4.RIGID STEEL CONDUIT SHALL BE USED WHERE EMBEDDED IN CONCRETE; EMBEDDED IN BRICK <br />OR MASONRY WALLS; EXPOSED ON INTERIOR OF BUILDINGS BELOW EIGHT FEET WHERE <br />SUBJECT TO PHYSICAL DAMAGE; EXPOSED ON EXTERIOR OF BUILDING; DAMP OR WET <br />LOCATIONS; EXPOSED ON ROOF OR IN CLASSIFIED AREAS. RIGID STEEL CONDUIT SHALL NOT BE <br />INSTALLED IN DIRECT CONTACT WITH EARTH OR SAND. <br />5.CONDUITS PENETRATING THRU SLAB SHALL BE RIGID GALVANIZED STEEL. <br />6.EMT SHALL BE INSTALLED IN DRY LOCATIONS SUCH AS, PARTITIONS, CEILING SPACES AND STUD <br />WALLS, OR WHERE EXPOSED BELOW EIGHT FEET AND NOT SUBJECT TO PHYSICAL DAMAGE. <br />7.IMT SHALL BE USED WHERE EXPOSED BELOW EIGHT FEET AND SUBJECT TO PHYSICAL DAMAGE. <br />8.FLEXIBLE STEEL CONDUIT MAY BE INSTALLED WHERE CONCEALED ABOVE CEILING OR IN <br />NON-MASONRY/CONCRETE WALLS AND PROPERTY SUPPORTED. <br />9.LIQUID-TIGHT FLEXIBLE CONDUIT SHALL BE INSTALLED FOR FINAL CONNECTION TO MOTORS, <br />CONTROL DEVICES MOUNTED ON VIBRATING OR ROTATING EQUIPMENT, EQUIPMENT INDICATED <br />ON DRAWINGS TO HAVE FLEXIBLE CONNECTIONS, AND IN ALL AREAS WHERE EXPOSED TO <br />MOISTURE AND FLEXIBLE CONNECTIONS ARE REQUIRED. ALL FLEXIBLE CONDUIT SHALL CONTAIN <br />A GROUND CONDUCTOR SIZED PER CODE. <br />10.SCHEDULE 40 PVC CONDUIT WITH CODE SIZED GROUND CONDUCTOR SHALL BE USED BELOW <br />GRADE ONLY, IF APPROVED AND INSTALLED PER LOCAL CODES UNLESS OTHERWISE SPECIFIED. <br />DO NOT ROUTE BELOW GRADE CONDUITS THROUGH AREAS OF FUTURE CONSTRUCTION. <br />INSTALL 30" BELOW GRADE. PROVIDE PVC-COATED STEEL CONDUIT FOR ALL ELBOWS AND <br />RISERS. NON-METALLIC CONDUIT SHALL NOT BE INSTALLED IN; CONCRETE BUILDINGS, BRICK OR <br />MASONRY CONSTRUCTION; IN WALLS; ABOVE CEILINGS OR IN CRAWL SPACES. <br />11.MC CABLE IS ACCEPTABLE IN AREAS WHERE NOT SUBJECT TO DAMAGE SUCH AS IN FURRED OUT <br />WALLS AND ABOVE CEILINGS PROVIDED ALL SUPPORT REQUIREMENTS ARE MET AND PROVIDE IT <br />IS INSTALLED AS FOLLOWS: <br />TRADITIONAL CONDUIT/WIRE SYSTEM SHALL BE USED FROM THE PANEL TO AN ACCESSIBLE <br />SPACE IN THE CEILING. A CODE SIZE JUNCTION BOX/BOXES SHALL BE INSTALLED IN THE <br />ACCESSIBLE CEILING AREA. THHN/THWN, 90 DEGREE CONDUCTORS IS THEN PULLED FROM <br />THE J-BOX TO THE PANEL WHERE THE CONDUCTORS ARE TERMINATED ON THE BREAKERS. <br />FROM THE J-BOX IN THE CEILING, MC CABLE, WITH THE FULLY RATED GROUND, MAY THEN BE <br />RUN TO THE BRANCH DEVICE. <br />THE METHOD USED TO CUT THE MC CABLE IS DONE WITH MANUFACTURER APPROVED TOOLS <br />ONLY. SPECIFICALLY A TOOL DESIGNED TO CUT THE METAL JACKET WITHOUT DAMAGING THE <br />WIRE INSIDE. AFTER THE JACKET HAD BEEN CUT, A PLASTIC BUSHING IS INSERTED TO <br />FURTHER PROTECT THE WIRING. THEN TEST ALL CIRCUITS TO ENSURE POLARITY, VOLTAGE <br />AND GROUNDING. <br />12.ALL CONDUIT PENETRATIONS THROUGH FIRE-RATED FLOOR SLABS, SHAFTS AND WALLS SHALL <br />BE SEALED TO PREVENT THE SPREAD OF FIRE OR SMOKE WITH AN APPROVED UL LISTED FIRE <br />STOP OR FIRE RESISTANT SEALANT. THE RATING OF THE FIRE STOP OR SEALANT SHALL BE <br />EQUAL TO THE RATING OF THE ELEMENT PENETRATED. <br />13.CONDUITS REFERENCED AS CONDUIT ONLY (C.O.) SHALL BE CAPPED AND PROVIDED WITH A <br />NYLON PULL STRING AND TAGS INDICATING THE ORIGINATION AND FUNCTION FOR THE CONDUIT. <br />14.PREMANUFACTURE CONDUIT SYSTEMS MAY BE USED FOR LIGHTING SYSTEMS. CONTRACTOR <br />SHALL FURNISH COMPLETE SYSTEM WITH U.L. LISTED COMPONENTS AS APPROVED BY LOCAL <br />JURISDICTION. CONTRACTOR SHALL PROVIDE SHOP DRAWING OF ENTIRE SYSTEM INDICATING <br />ALL DEVICES, CONDUIT LENGTHS AND SUPPORTS. SYSTEM SHALL BE 277/480 OR 120/208 VOLT <br />RATED. <br />15.CONDUITS CROSSING BUILDING EXPANSION AND/OR SEISMIC JOINTS SHALL BE PROVIDED WITH <br />EXPANSION DEFLECTION FITTINGS AT THE EXPANSION AND/OR SEISMIC JOINT. <br />16.ALL CONDUIT FOR ROOFTOP EQUIPMENT SHALL BE ROUTED BELOW THE ROOF STRUCTURE. ALL <br />PENETRATIONS THROUGH ROOF OR EXTERIOR WALL SHALL BE FLASHED AND MADE <br />WATER-TIGHT. PROVIDE ROOF JACKS AT ALL PENETRATIONS. <br />17.CONTRACTOR SHALL PROVIDE CONDUIT SEALS AS REQUIRED BY CODE. <br />18.CONDUITS USED FOR EQUIPMENT GROUNDING SHALL UTILIZE APPROVED GROUNDING <br />COUPLINGS. <br />19.ALL CONDUITS SHALL INCLUDE A GREEN EQUIPMENT GROUND SIZED PER CODE, #12 AWG <br />MINIMUM. <br />20.MINIMUM ABOVE GROUND CONDUIT SIZE SHALL BE 1/2". MINIMUM UNDERGROUND CONDUIT SIZE <br />SHALL BE 3/4". <br />21.ALL EMPTY CONDUITS SHALL INCLUDE A NYLON PULL LINE AND SHALL BE CAPPED AND <br />PERMANENTLY MARKED TO IDENTIFY ITS PURPOSE AND WHERE IT TERMINATES. <br />H.CONDUCTORS <br />1.ALL CONDUCTORS SHALL BE COPPER, 600V AND RATED 90 DEGREE C. PROVIDE TYPE THHN IN <br />DRY LOCATIONS AND TYPE THWN-2 IN WET (OR DRY) LOCATIONS. MINIMUM SIZE #12 AWG. <br />2.WHERE INSTALLED IN RACEWAY, CONDUCTORS OF SIZE NO.8 AND LARGER SHALL BE STRANDED. <br />3.CONDUCTORS SIZE NO. 1 AWG AND SMALLER WITH 90 DEGREE C INSULATION ARE TO USE THE 60 <br />DEGREE C COLUMN OF THE CODE, TABLE 310.15(B)(16), TO DETERMINE AMPACITY. CONDUCTORS <br />#1/0 AWG AND LARGER WITH 90 DEGREE C INSULATION ARE TO USE THE 75 DEGREE C COLUMN <br />OF THE CODE, TABLE 310.15(B)(16), TO DETERMINE AMPACITY. <br />4.ALL CONDUCTORS/CABLING SHALL BE INSTALLED IN AN APPROVED RACEWAY UNLESS <br />SPECIFICALLY OTHERWISE NOTED. <br />I.PANELBOARDS, SWITCHBOARDS AND DISTRIBUTION BOARDS <br />1.ENCLOSURES SHALL BE NEMA 1 FOR INDOOR AND NEMA 3R FOR OUTDOOR USE. ALL <br />SWITCHBOARDS SHALL BE PAINTED MANUFACTURERS STANDARD GRAY OVER A RUST INHIBITING <br />PRIMER ON CORROSIVE RESISTANT METAL SURFACE. SWITCHBOARD SHALL BE NEW AND FREE <br />OF ANY SCRATCHES, DENTS OR ANY DAMAGE. <br />2.ALL BUSSING SHALL BE PLATED COPPER UNLESS OTHERWIISE NOTED WITH BRACING PER <br />SINGLE LINE DIAGRAM. THE AIC RATING SHALL NEVER BE LESS THAN THE UTILITY COMPANY <br />AVAILABLE FAULT CURRENT. CONTRACTOR SHALL VERIFY THE FAULT CURRENT WITH UTILITY <br />COMPANY PRIOR TO ORDERING GEAR TO ENSURE PROPER BRACING AND SERIES RATING. <br />SWITCHBOARDS SHALL BE APPROVED BY THE UTILITY COMPANY SERVING THE PROJECT. <br />3.ALL PANELBOARDS SHALL BE U.L. LISTED FOR SERIES RATING COMBINATION FUSE TO CIRCUIT <br />BREAKER OR CIRCUIT BREAKER TO CIRCUIT BREAKER ARRANGEMENT. ALL BUSSING SHALL BE <br />PLATED COPPER AND ALL CIRCUIT BREAKERS SHALL BE BOLT-ON TYPE. <br />4.PANELBOARDS SHALL BE MOUNTED AS SHOWN ON DRAWINGS. PROVIDE CIRCUIT BREAKERS AS <br />SHOWN ON PANEL SCHEDULES AND SINGLE LINE DIAGRAM. PROVIDE WITH HINGED DOORS, <br />TYPED PANEL CARDS AND PROPER BUSSING. <br />5.ALL PANELBOARDS AND CONTROL CABINETS SHALL BE LOCKABLE AND KEYED ALIKE. <br />6.THE UNDERGROUND PULL SECTION SHALL BE SIZED PER PLANS AND UTILITY COMPANY <br />REQUIREMENTS. IN NO CASE SHALL THE DIMENSIONS OF THE PULL SECTION BE LESS THAN <br />REQUIRED BY THE SERVING UTILITY COMPANY. <br />7.THE METER/MAIN SECTION SHALL INCLUDE ALL METERING EQUIPMENT INCLUDING CURRENT <br />TRANSFORMERS, SOCKET, TEST BLOCK AND METERING BARRIER SEPARATING METERING <br />EQUIPMENT FROM MAIN DEVICE. THE MAIN SHALL BE A THERMAL MAGNETIC MOLDED CASE <br />CIRCUIT BREAKER OR SOLID STATE CIRCUIT BREAKER. FUSIBLE SWITCHES SHALL NOT BE <br />ACCEPTED UNLESS SPECIFICALLY SHOWN ON PLANS. <br />8.DISTRIBUTION BOARDS AND PANELBOARDS SHALL BE BY THE SAME MANUFACTURER AS UGPS <br />AND METER/MAINS. <br />9.DIMENSIONS OF SWITCHGEAR DESIGN ARE TO BE USED IN LAYING OUT ELECTRICAL ROOM. ANY <br />DEVIATIONS MAY VIOLATE CODE MINIMUM CLEARANCE. CONTRACTOR SHALL PROVIDE A SCALED <br />AND DIMENSIONED PLAN OF ELECTRICAL ROOM SHOWING ACTUAL SWITCHBOARD SIZE AND <br />EXACT LOCATION. THIS DRAWING SHALL BE FURNISHED WITH SHOP DRAWING SUBMITTAL. <br />10.DISTRIBUTION BOARDS SHALL BE FLOOR STANDING, FULL HEIGHT WITH MINIMUM OF 60 INCHES <br />OF DISTRIBUTION AND CAPABLE OF HOUSING CIRCUIT BREAKER AS LARGE AS THE MAIN CIRCUIT <br />BREAKER. THE BUSSING SHALL BE PLATED COPPER BRACED FOR 65,000 AMPS (UNLESS <br />OTHERWISE NOTED ON PLANS). THE BUSSING SHALL MATCH UP WITH METER MAIN AND BOLT <br />TOGETHER. CABLE CONNECTIONS SHALL NOT BE ACCEPTED UNLESS SPECIFICALLY SHOWN ON <br />PLANS. CIRCUIT BREAKERS IN THESE SECTIONS SHALL HAVE THE SAME INTERRUPTING RATING <br />AS THE MAIN CIRCUIT BREAKER. CIRCUIT BREAKERS DOWN STREAM SHALL BE SERIES RATED <br />AND SHALL BARE ALL TAGS AND CODE REQUIRED IDENTIFICATION. <br />11.HORIZONTAL AND VERTICAL BUSSES SHALL BE FULL LENGTH. BUSS SHALL HAVE A MINIMUM <br />WITHSTAND RATING EQUAL TO AVAILABLE FAULT CURRENT INDICATED ON DRAWINGS, BUT IN NO <br />CASE SHALL THE RATING BE LESS THAT 65,000 AMPS, SYMMETRICAL UNLESS SPECIFICALLY <br />SHOWN ON PLANS. <br />12.PROVIDE INTERCONNECTED FULL CAPACITY NEUTRAL BUS IN EACH SECTION WITH THE SAME <br />RATINGS AND CONSTRUCTION AS THE PHASE BUSSES. <br />13.PROVIDE INTERCONNECTED GROUND BUS IN EACH SECTION. <br />14.PROVIDE SPACE AND ALL HARDWARE AND MOUNTING ATTACHMENTS FOR FUTURE DEVICES AS <br />INDICATED ON THE DRAWINGS. <br />15.MAIN HORIZONTAL BUSSING SHALL BE FULL CAPACITY IN ALL SWITCHBOARD SECTIONS. <br />16.VERTICAL BUSS MAY BE TAPERED, TO NOT LESS THAN ONE THIRD THE AMPACITY RATING OF THE <br />MAIN HORIZONTAL BUSS; BUT IN NO CASE SHALL THE VERTICAL BUSS BE OF LESS CAPACITY <br />THAN THE SUM OF THE FRAME SIZE AMPACITIES OF OVERCURRENT DEVICES MOUNTED IN THE <br />RESPECTIVE SECTIONS INCLUDING ANY INDICATED SPARES AND SPACES. <br />17.THE SWITCHBOARD BUSSING SHALL BE OF SUFFICIENT CROSS-SECTIONAL AREA TO MEET UL <br />STANDARD 891 ON TEMPERATURE RISE. BUS SHALL BE PLATED COPPER. THE THROUGH BUS <br />SHALL HAVE PROVISIONS FOR THE ADDITION OF FUTURE SECTION. THE THROUGH BUS <br />SUPPORTS, CONNECTIONS AND JOINTS ARE TO BE BOLTED WITH GRADE 5 HEX HEAD BOLTS AND <br />BELLEVILLE WASHERS TO MINIMIZE MAINTENANCE REQUIREMENTS. <br />J.OVERCURRENT DEVICES <br />1.ALL OVER CURRENT DEVICES, INCLUDING BUT NOT LIMITED TO, CIRCUIT BREAKERS, FUSED <br />SWITCHED, COMBINATION MOTOR STARTERS, ETC. SHALL HAVE AN INTERRUPTING RATING <br />EQUAL TO OR EXCEEDING THE AVAILABLE FAULT CURRENT, INCLUDING MOTOR CONTRIBUTION. <br />CONTRACTOR SHALL VERIFY THE UTILITY CO. AVAILABLE FAULT CURRENT PRIOR TO ORDERING <br />EQUIPMENT. IN THE EVENT THE AVAILABLE FAULT CURRENT IS HIGHER THAN SHOWN ON THE <br />DRAWINGS, CONTRACTOR SHALL ADJUST, AT NO COST, AS REQUIRED. <br />2.ALL CIRCUIT BREAKERS SHALL BE BY THE SAME MANUFACTURE, AS INDICATED ON THE SINGLE <br />LINE DIAGRAM AND PANEL SCHEDULES. <br />3.CIRCUIT BREAKERS SHALL BE ARRANGED IN PANELS SO THAT PROPER TRIP SETTINGS AND <br />NUMBERS CORRESPOND TO THE PANEL SCHEDULES ON THE DRAWINGS. IN NO CASE SHALL THE <br />CONTRACTOR MODIFY THE BREAKER CONFIGURATION UNLESS WRITTEN AUTHORIZATION IS <br />GIVEN BY THE ENGINEER OF RECORD. <br />4.TWO OR THREE POLE CIRCUIT BREAKERS SHALL BE COMMON TRIP TYPE. SINGLE POLE <br />BREAKERS WITH TIE-BAR BETWEEN HANDLES ARE NOT ACCEPTABLE. <br />5.WHERE BRANCH CIRCUITS FEED MOTORS, WATER HEATERS AND SIGNAL DEVICES, THE BREAKER <br />SHALL BE PROVIDED WITH A PERMANENT LOCK-OFF DEVICE. <br />6.ALL PANELBOARD CIRCUIT BREAKERS SHALL BE BOLT-ON TYPE. <br />7.MAIN SERVICE DISCONNECT DEVICES SHALL BE CIRCUIT BREAKERS UNLESS OTHERWISE <br />SPECIFIED IN PLANS. <br />8.MAIN SERVICE DISCONNECTS RATED 1000 AMPS OR MORE, SOLIDLY GROUND WYE WITH <br />GREATER THAN 150 VOLTS TO GROUND AND BUT NOT EXCEEDING 600 VOLTS PHASE TO PHASE <br />SHALL BE PROVIDED WITH A ZERO SEQUENCE GROUND FAULT DETECTION/INTERUPT DEVICE. <br />ALL GROUND FAULT EQUIPMENT SHALL BE TESTED AND SET BY AN INDEPENDENT TESTING <br />LABORATORY AND SHALL BE SET AS RECOMMENDED BY THE TESTING AGENCY SO AS TO BE <br />COORDINATED WITH OTHER PROTECTION DEVICES WITHIN THE ELECTRICAL DESIGN. COPIES OF <br />THE TEST AND SETTINGS SHALL BE SENT TO THE ARCHITECT. CONTRACTOR SHALL INCLUDE IN <br />HIS BID ALL COST ASSOCIATED WITH TESTING AND SETTING OF GROUND FAULT DEVICES. <br />9.NEW CIRCUIT BREAKERS AND FUSIBLE SWITCHES INSTALLED IN EXISTING SWITCHBOARDS, <br />DISTRIBUTION BOARDS AND PANELBOARDS SHALL MATCH EXISTING MANUFACTURER AND ALL <br />ELECTRICAL CHARACTERISTICS OF THE EXISTING EQUIPMENT BUT IN NO CASE SHALL THE <br />INTERRUPTING RATING BE LESS THAN THE AVAILABLE FAULT CURRENT, INCLUDING MOTOR <br />CONTRIBUTION. <br />10.ALL FUSES SHALL BE CLASS "R" BUSS CO. LPN-RK (250V) OR LPS-RK (600V), UNLESS OTHERWISE <br />NOTED. ALL FUSES SHALL PROPERLY SERIES RATE WITH DOWN STREAM DEVICES. <br />K.LIGHT FIXTURES <br />1.ALL LIGHTING SHALL COMPLY WITH APPLICABLE ENERGY CODES WHETHER INDICATED IN THESE <br />DRAWINGS OR NOT. <br />2.PROVIDE LIGHT FIXTURES COMPLETE WITH LAMPS, DRIVERS, BALLASTS, SOCKETS, HOUSINGS, <br />CEILING TRIM RINGS FOR SPECIAL CEILINGS, BRACKETS, DIFFUSERS/LENSES AND OUTLET <br />BOXES. <br />3.THE CATALOG NUMBERS INCLUDED IN THE FIXTURE SCHEDULE SHALL BE CONSIDERED TO <br />ESTABLISH THE TYPE OR CLASS OF FIXTURE WITH A PARTICULAR MANUFACTURER ONLY. THE <br />FIXTURE LENGTH, QUANTITY, TYPE OF LAMPS, COMPONENT MATERIALS, ACCESSORIES, <br />MOUNTING TYPE AND ALL OTHER FEATURES REQUIRED TO FULFILL THE TOTAL DESCRIPTION OF <br />THE FIXTURE BASED ON ALL DRAWINGS AND SPECIFICATION INFORMATION SHALL BE COMPLIED <br />WITH REGARDLESS OF WHETHER OR NOT THE CATALOG NUMBER ON THE FIXTURE SCHEDULE <br />SPECIFICALLY INCLUDES THESE FEATURES. IF ANY CONFLICT EXISTS BETWEEN THE CATALOG <br />NUMBER, THE DESCRIPTION, OR FIELD CONDITIONS, THE CONTRACTOR SHALL NOTIFY THE <br />ARCHITECT AND ENGINEER PRIOR TO ORDERING. <br />4.LIGHT FIXTURES SHALL BE OF TYPES AS INDICATED IN THE FIXTURE SCHEDULE ON THE <br />DRAWINGS. <br />5.INCLUDE AN ALLOWANCE OF $500.00 FOR THE SUPPLY AND INSTALLATION OF LIGHT FIXTURE <br />WHERE OUTLET IS SHOWN ON DRAWINGS WITHOUT A FIXTURE TYPE DESIGNATION. <br />6.ALL FIXTURES OF ONE TYPE SHALL BE OF ONE MANUFACTURER AND OF IDENTICAL FINISH AND <br />APPEARANCE, UNLESS OTHERWISE NOTED ON DRAWINGS. <br />7.PROVIDE SEISMIC RESTRAINTS, AS REQUIRED, BY LOCAL JURISDICTION. <br />8.ALL LIGHT FIXTURES SHALL BE LED UNLESS OTHERWISE SPECIFIED IN THESE DRAWINGS. <br />9.ALL LIGHT FIXTURES SHOWN AS "EM" SHALL BE PROVIDED WITH EITHER AN INTEGRAL BATTERY <br />PACK OR EXTERNAL EMERGENCY LIGHTING INVERTER. <br />10.ALL LIGHT FIXTURES SHALL MEET TITLE 20 AND TITLE 24 REQUIREMENTS WHETHER SHOWN ON <br />PLANS OR NOT. <br />11.ALL LIGHT FIXTURES SHALL HAVE ALL PARTS AND FITTINGS NECESSARY TO COMPLETE AND <br />PROPERLY INSTALL THE FIXTURE IN THE APPLICABLE LOCATION. <br />12.SURFACE AND/OR WALL MOUNTED LIGHTING FIXTURES SHALL NOT HAVE ANY EXPOSED CHASE <br />NIPPLES OR CONDUIT KNOCKOUTS VISIBLE TO VIEW WITHIN FIXTURE HOUSING. LIGHTING <br />FIXTURES MOUNTED IN CONTINUOUS ROWS SHALL HAVE CHASE NIPPLES OR CONDUIT <br />KNOCKOUTS BETWEEN FIXTURE HOUSINGS, BUT SHALL NOT HAVE VISIBLE CHASE <br />NIPPLE/CONDUIT KNOCKOUTS ON THE VISIBLE ENDS OF THE CONTINUOUS ROW LIGHTING <br />FIXTURE. <br />13.WHERE FIXTURE COLOR IS INDICATED TO BE SELECTED BY THE ARCHITECT, PROVIDED TWO <br />COLOR CHIP SAMPLES FOR REVIEW. <br />14.RECESSED FIXTURES MUST ALL BE U.L. APPROVED FOR RECESSED INSTALLATION WITH PLASTER <br />FRAME AND ATTACHED PULLBOX. LAMP ENCLOSURE, REFLECTORS AND FINISH WIRING SHALL <br />NOT BE INSTALLED UNTIL PLASTERING IS COMPLETE. FINISH TRIM SHALL NOT BE INSTALLED <br />UNTIL FINISH PAINTING OF THE ADJACENT SURFACE IS COMPLETE. <br />15.ALL FIXTURES SHALL BEAR U.L. LABEL OF APPROVAL FOR FIXTURE WATTAGE INDICATED. <br />16.LIGHT FIXTURES INSTALLED IN DAMP OR WET LOCATIONS SHALL BE UL LISTED FOR SUCH <br />LOCATION. <br />17.LIGHT FIXTURES INSTALLED IN CONTACT WITH INSULATION SHALL HAVE PROPER I.C. RATING <br />WHETHER SHOWN ON PLANS OR NOT. FIXTURES WITHOUT I.C. RATING SHALL HAVE A <br />SEPARATION OF 3" BETWEEN THE FIXTURE AND THE INSULATION. <br />18.FIXTURE LENSES AND DIFFUSERS SHALL BE AS CALLED OUT ON FIXTURE SCHEDULE. <br />19.ACRYLIC LENSES SHALL BE MANUFACTURED FROM 100% VIRGIN ACRYLIC AND BE .125" THICK <br />MINIMUM. <br />20.IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY ACTUAL CEILING TYPE AS DEFINED <br />ON THE ARCHITECTURAL DRAWINGS AND FURNISH ALL FIXTURES WITH THE CORRECT MOUNTING <br />DEVICES AND PROPER OPERATING VOLTAGES. CONTRACTOR SHALL VERIFY DEPTH OF ALL <br />RECESSED FIXTURES WITH ARCHITECTURAL DRAWINGS PRIOR TO ORDERING. ANY <br />DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT PRIOR TO ORDERING. <br />21.RECESSED LIGHT FIXTURES MOUNTED FLUSH IN "LAY-IN" T-BAR OR CONCEALED SPLINE CEILING <br />SHALL BE PROVIDED WITH TWO CLIPS ON EACH END OF THE FIXTURE AND CONNECTED TO THE <br />CEILING CROSS RUNNERS. PROVIDE TWO 12 GAUGE FIXTURE HANGER WIRE ATTACHED TO <br />STRUCTURAL MEMBERS AND CONNECT TO DIAGONAL CORNERS OF FIXTURE. FIXTURE SHALL <br />SET LEVEL AND FLUSH WITH CEILING GRID SYSTEM. <br />22.SURFACE MOUNTED FIXTURES INSTALLED ON DRY WALL OR PLASTER CEILINGS AND WEIGHING <br />LESS THAN 50 POUNDS MAY BE SUPPORTED FROM OUTLET BOX. PROVIDE STRUCTURAL <br />SUPPORTS ABOVE DRYWALL OR PLASTER CEILING FOR INSTALLATION OF FIXTURE WEIGHING <br />MORE THAN 50 POUNDS AND SECURE FIXTURES TO STRUCTURAL SUPPORTS. THE USE OF <br />TOGGLE BOLTS IS PROHIBITED. <br />23.LIGHT FIXTURES RECESSED IN CEILING OR DRY WALL WHICH HAS A FIRE RESISTIVE RATING OF <br />ONE HOUR OR MORE SHALL BE ENCLOSED IN A BOX WHICH HAS A FIRE RATING EQUAL TO THAT <br />OF THE CEILING OR WALL. THE SPACE FROM THE FIXTURE TO THE ENCLOSURE SHALL BE A <br />MINIMUM OF 3". <br />24.LENS AND DIFFUSERS SHALL BE CLEANED COMPLETELY OF ALL DUST, DIRT, AND FINGERPRINTS <br />AFTER THE INSTALLATION OF THE LIGHT FIXTURES, CEILING, PAINTING, AND PRIOR TO <br />OCCUPANCY OF THE FACILITY BY OWNER. <br />25.PROVIDE ILLUMINATED EXIT SIGNS AS REQUIRED BY BUILDING DEPARTMENT OR FIRE MARSHALL. <br />EXIT SIGNS SHALL HAVE SELF-CONTAINED EMERGENCY BATTERY PACKS. PROVIDE CIRCUITRY <br />AS REQUIRED FOR EXIT SIGNS, VERIFY LOCATIONS. CONTRACTOR SHALL PROVIDE ADDITIONAL <br />EXIT SIGNS AND CIRCUITRY AS REQUIRED WITHOUT ADDITIONAL COST. <br />PART 3 - SYSTEMS <br />L.GROUNDING <br />1.THE ELECTRICAL SYSTEM SHALL BE GROUNDED PER CODE. <br />2.EQUIPMENT GROUNDING SHALL BE PER 250.118. <br />3.THE MAXIMUM RESISTANCE TO GROUND SHALL NOT EXCEED 25 OHMS TO GROUND. <br />4.THE CONTRACTOR SHALL PROVIDE ALL INSTRUMENTATION AND TESTS FOR MEASURING THE <br />RESISTANCE OF EACH PHASE TO GROUND. A PROPERLY CALIBRATED "MEGGER" TYPE <br />INSTRUMENT SHALL BE USED. IN THE EVENT THAT HIGH RESISTANCE TO GROUNDS ARE FOUND <br />THEY SHALL BE ISOLATED. MAKE PROPER CORRECTIONS TO RESTORE THE RESISTANCE TO AN <br />ACCEPTABLE VALUE. <br />M.MECHANICAL AND PLUMBING <br />1.CONTRACTOR SHALL INCLUDE ALL H.V.A.C. AND PLUMBING POWER AND CONTROL <br />REQUIREMENTS IN BASE BID. REVIEW MECHANICAL AND PLUMBING DRAWINGS FOR FINAL <br />REQUIREMENTS/ LOCATIONS. <br />2.VERIFY EXACT LOCATIONS AND ORIENTATION OF ALL MECHANICAL AND PLUMBING EQUIPMENT <br />WITH MECHANICAL AND PLUMBING DRAWINGS. FIELD VERIFY CONDITIONS WITH MECHANICAL <br />AND PLUMBING CONTRACTORS PRIOR TO ROUGH-IN. <br />3.COORDINATE WITH MECHANICAL AND PLUMBING DRAWINGS AND PROVIDE, INCLUDING BUT NOT <br />LIMITED TO, ALL CONDUIT, WIRING, TIME CLOCKS, STARTERS, CONTROL DEVICES, RELAYS, <br />DISCONNECT SWITCHES, ETC. FOR THE PROPER OPERATION OF THE MECHANICAL AND <br />PLUMBING SYSTEMS. REFER TO THE MECHANICAL AND PLUMBING DRAWINGS AND ADDENDUMS <br />FOR ADDITIONAL ELECTRICAL REQUIREMENTS. <br />4.ALL EQUIPMENT, ENCLOSURES, DEVICES, DISCONNECT SWITCHES, CONNECTIONS, ETC. <br />LOCATED OUTDOORS OR IN WET LOCATIONS SHALL BE WEATHERPROOF. <br />5.PROVIDE WEATHERPROOF "WHILE-IN-USE", EXTRA-DUTY, GFCI RECEPTACLES WITHIN 25 FT. OF <br />MECHANICAL AND PLUMBING EQUIPMENT WHETHER SHOWN ON THESE DRAWINGS OR NOT. <br />N.COMMUNICATIONS <br />1.TELEPHONE AND DATA OUTLETS SHALL CONSIST OF A SINGLE-GANG BOX WITH (1) 3/4"C.O. <br />STUBBED 6" ABOVE ACCESSIBLE CEILING WITH A NYLON PULL STRING. PROVIDE PLASTER RING <br />AND A SINGLE-PORT FACE PLATE, COLOR SPECIFIED BY ARCHITECT, UNLESS OTHERWISE NOTED. <br />2.TELEPHONE AND DATA OUTLETS IN BUILDINGS SERVED BY A PLENUM RATED CEILING OR AS <br />REQUIRED BY LOCAL AUTHORITY SHALL HAVE 3/4"C.O. WITH NYLON PULL STRING ROUTED TO <br />THE NEAREST TELEPHONE BACKBOARD. <br />3.IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO VERIFY THE TELEPHONE <br />SERVICE ENTRANCE REQUIREMENTS AND SYSTEM DISTRIBUTION REQUIREMENTS WITH THE <br />SERVING LOCAL TELEPHONE UTILITY COMPANY AND APPROPRIATE VENDOR. <br />O.OTHER TRADES <br />1.CONTRACTOR SHALL REVIEW DRAWINGS AND SPECIFICATIONS OF ALL OTHER TRADES, <br />INCLUDING BUT NOT LIMITED TO, ARCHITECTURAL, MECHANICAL, PLUMBING, LANDSCAPE, <br />REFRIGERATION, KITCHEN, FIRE ALARM, LIFE SAFETY, SPRINKLER, SECURITY, AUDIO/VISUAL AND <br />COMMUNICATIONS AND INCLUDE IN HIS BID ALL ELECTRICAL POWER, CONTROLS, CONDUIT ETC. <br />NECESSARY TO MAKE THESE SYSTEMS OPERABLE WHETHER INDICATED ON THESE DRAWINGS <br />OR NOT. <br />P.UTILITIES <br />1.CONTRACTOR SHALL INCLUDE IN HIS BID ALL TRENCHING, CONDUIT, CONCRETE ENCASEMENT, <br />PULL BOXES STRUCTURES, FEES, ETC. AS NECESSARY TO PROVIDE A COMPLETE, OPERABLE <br />SYSTEM PER THE SERVING UTILITY COMPANIES REQUIREMENTS. <br />2.CONTRACTOR SHALL BUILD PER THE UTILITY COMPANIES ENGINEERED DRAWINGS ONLY. <br />3.CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND UTILITY COMPANY REQUIREMENTS <br />PRIOR TO BID. <br />NAME <br />TYPE <br />WATTS <br />ID <br /># <br />ID <br />SHEET <br />ID <br />SHEET <br />ELECTRICAL EQUIPMENT <br />-NO PREFIX: PANEL BOARD <br />-T- OR XFMR PREFIX: TRANSFORMER <br />-LCP PREFIX: LIGHTING CONTROL PANEL <br />-DB PREFIX: DISTRIBUTION BOARD <br />-MSB PREFIX: MAIN SWITCHBOARD <br />-MSG PREFIX: MAIN SWITCHGEAR <br />-INV PREFIX: INVERTER <br />-MCC PREFIX: MOTOR CONTROL CENTER <br />LIGHT FIXTURE <br />-TYPE IS LIGHT FIXTURE DESIGNATION <br />-WATTS IS LIGHT FIXTURE INPUT WATTAGE <br />MECHANICAL, PLUMBING AND OTHER EQUIPMENT <br />-ID IS EQUIPMENT DESIGNATION <br />-# IS UNIT NUMBER <br />DETAIL <br />-ID IS DETAIL DESIGNATION <br />-SHEET IS LOCATION OF DETAIL <br />MATCH LINE <br />-ID IS MATCH LINE DESIGNATION <br />-SHEET IS LOCATION OF CONTINUATION <br />CALL OUTS <br />MAY BE USED WITH OR WITHOUT LEADERS <br />SCOPE OF WORK <br />GENERAL ELECTRICAL SPECIFICATIONS <br />SHEET INDEX <br />E0.1 SPECIFICATIONS AND ABBREVIATIONS <br />E0.2 GENERAL NOTES AND SYMBOLS <br />E1.1 OVERALL KEY PLAN <br />E2.1 PARTIAL SINGLE LINE DIAGRAM <br />E4.1 LAB POWER PLAN <br />E4.2 ROOF POWER PLAN <br />E4.5 LAB LIGHTING PLAN <br />E4.6 NORMAL PHOTOMETRICS <br />E4.7 EGRESS PHOTOMETRICS <br />E5.1 SCHEDULES <br />E6.1 EQUIPMENT SCHEDULE AND DETAILS <br />E8.1 TITLE 24 ENERGY FORMS <br />E0.1 <br />SPECIFICATIONS AND <br />ABBREVIATIONSPOWER AND LIGHTING FOR A NEW LAB AREA IN AN EXISTING BUILDING. <br />REMARKSNO.DATE <br />ar <br />c <br />h <br />i <br />t <br />e <br />c <br />t <br />u <br />r <br />e <br />in <br />t <br />e <br />r <br />i <br />o <br />r <br /> <br />d <br />e <br />s <br />i <br />g <br />n <br />pl <br />a <br />n <br />n <br />i <br />n <br />g <br />17 <br />8 <br />8 <br />0 <br /> <br />S <br />k <br />y <br /> <br />P <br />a <br />r <br />k <br /> <br />C <br />i <br />r <br />c <br />l <br />e <br />, <br /> <br />S <br />u <br />i <br />t <br />e <br /> <br />2 <br />3 <br />0 <br /> <br />- <br /> <br />I <br />r <br />v <br />i <br />n <br />e <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />6 <br />1 <br />4 <br />t <br />e <br />l <br /> <br />9 <br />4 <br />9 <br />. <br />5 <br />5 <br />3 <br />. <br />8 <br />9 <br />0 <br />0 <br />Ed <br />w <br />a <br />r <br />d <br />s <br />DA <br />I <br />M <br />L <br />E <br />R <br /> <br />A <br />C <br />P <br />L <br />30 <br />0 <br />9 <br /> <br />D <br />A <br />I <br />M <br />L <br />E <br />R <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />. <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />23 <br />2 <br />7 <br />6 <br /> <br />S <br />O <br />U <br />T <br />H <br /> <br />P <br />O <br />I <br />N <br />T <br />E <br /> <br />D <br />R <br />. <br />, <br /> <br />U <br />N <br />I <br />T <br />1 <br />0 <br />2 <br />, <br />LA <br />G <br />U <br />N <br />A <br /> <br />H <br />I <br />L <br />L <br />S <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />6 <br />5 <br />3 <br />O: <br /> <br />9 <br />4 <br />9 <br />- <br />4 <br />1 <br />9 <br />- <br />9 <br />9 <br />0 <br />8 <br /> <br />F <br />: <br /> <br />9 <br />4 <br />9 <br />- <br />4 <br />1 <br />9 <br />- <br />9 <br />8 <br />7 <br />0 <br />LE <br />A <br />V <br />E <br /> <br />B <br />L <br />A <br />N <br />K <br /> <br />F <br />O <br />R <br /> <br />C <br />I <br />T <br />Y <br /> <br />S <br />T <br />A <br />M <br />P <br />3009 S Daimler St <br />11/18/2024