Laserfiche WebLink
CUSTOMER <br />DATE: <br />SCALE: <br />SHEET # <br />CUSTOMER <br />E-7.2 <br />APN <br />PLAN SET REVISIONS <br />399-031-24 / 399-031-23 <br />6/8/2023 <br />SAMUELI ACADEMY <br />1901/1919 N. FAIRVIEW ST. <br />SANTA ANA, CA. 92705 <br />CONTRACTOR SIGNATURE: <br />DAVID CLEVELAND <br />CO <br />N <br />T <br />R <br />A <br />C <br />T <br />O <br />R <br />' <br />S <br /> <br />L <br />I <br />C <br />E <br />N <br />S <br />E <br /> <br /># <br /> <br />1 <br />0 <br />8 <br />9 <br />1 <br />1 <br />7 <br />CO <br />N <br />T <br />R <br />A <br />C <br />T <br />O <br />R <br />' <br />S <br /> <br />L <br />I <br />C <br />E <br />N <br />S <br />E <br /> <br /># <br /> <br />1 <br />0 <br />8 <br />9 <br />1 <br />1 <br />7 <br />DRAWN BY: <br />CHECKED BY: <br />APPROVED BY: <br />ENGINEER STAMP <br />STRING LAYOUT FOR <br />CARPORTS <br />OPTIMIZER STRING LAYOUT FOR ALL SOLAR PV CARPORTS N.T.S. <br />J.D. 12-01-22 <br />S.M. 05-02-23 <br />B.B. 05-02-23 <br />GENERAL NOTES <br />1. (2)MODULES PER PV OPTIMIZER CIRCUIT. <br />2. SEE SECTION 3 OF SPECIFICATIONS ON E-000 FOR CONDUIT TYPES AND USES, AS WELL AS WHEN <br />EXPANSION JOINTS ARE REQUIRED. <br />3. ALL EQUIPMENT REQUIRES ATTACHMENT DETAILS PER MANUFACTURER'S INSTRUCTIONS; EQUIPMENT <br />THAT IS 400 LBS OR MORE REQUIRE STRUCTURAL CALCULATIONS OF THE ATTACHMENTS. <br />4. WORKING CLEARANCES FOR ALL NEW ELECTRICAL EQUIPMENT SHALL BE PER CEC ART. 110.26(A) AND <br />110.34(A). CONTRACTOR SHALL MAINTAIN WORKING AND MAINTENANCE CLEARANCES FOR EXISTING <br />EQUIPMENT. <br />5. SWITCHES FOR CIRCUIT BREAKERS USED AS SWITCHES SHALL BE INSTALLED SUCH THAT THE CENTER <br />OF THE GRIP OF THE OPERATING HANDLE, WHEN IN ITS HIGHEST POSITION, IS NOT MORE THAN 6 FEET 7 <br />INCHES ABOVE THE FLOOR OR WORKING PLATFORM PER CEC ART. 404.8(A). INVERTER INTEGRATED <br />SWITCHES MAY BE INSTALLED HIGHER THAN 6 FEET 7 INCHES PER CEC ART 705.70. <br />6. WHEN THE INVERTERS ARE NOT MOUNTED IN A READILY ACCESSIBLE LOCATION, THE INSTALLATION OF <br />THE INVERTERS AND PANEL BOARDS SHALL COMPLY WITH CEC ART. 705.70(1) THROUGH (4). <br />7. CONTRACTOR TO CONSULT INSTALLATION MANUALS OF NEW EQUIPMENT FOR PROPER MOUNTING <br />METHODS AND CLEARANCES. <br />8. EXACT CONDUIT ROUTE TBD BY CONTRACTOR. <br />9. CONDUITS AND FITTINGS VISIBLE TO THE PUBLIC SHALL BE PAINTED TO MATCH THE EXISTING BUILDING <br />IF REQUIRED BY THE JURISDICTION OR OWNER. <br />10. ALL CONDUITS ROUTED ON ROOFTOPS SHALL BE INSTALLED A MINIMUM DISTANCE OF 7/8" ABOVE THE <br />ROOF TO THE BOTTOM OF THE CONDUIT TO MAINTAIN THE ACCURACY OF THE ELECTRICAL <br />CALCULATIONS PER CEC ART. 310.15(B)(3)(C). LOCATE ATTACHMENT POINTS NOT MORE THAN 10' ON <br />CENTER AND MAXIMUM 3' FROM PULL POINT OR WALL PENETRATION. <br />STRING SUMMARY <br />CARPORT # STRING NAME MODULES PER <br />STRING <br />OPTIMIZERS PER <br />STRING <br />INVERTER <br />NUMBER <br />1 1-1 16 1 <br />1 1-2 16 1 <br />1 1-3 16 1 <br />1 1-4 18 1 <br />1 1-5 18 1 <br />1 2-1 16 2 <br />1 2-2 16 2 <br />1 2-3 16 2 <br />1 2-4 18 2 <br />1 2-5 18 2 <br />2 3-1 18 3 <br />2 3-2 18 3 <br />2 3-3 18 3 <br />2 3-4 18 3 <br />2 3-5 18 3 <br />3 3-6 18 3 <br />3 3-7 18 3 <br />3 4-1 18 4 <br />3 4-2 18 4 <br />3 4-3 18 4 <br />4 5-1 17 5 <br />4 5-2 17 5 <br />4 5-3 16 5 <br />4 5-4 16 5 <br />4 5-5 16 5 <br />4 5-6 16 5 <br />5 6-1 16 6 <br />5 6-2 16 6 <br />5 6-3 17 6 <br />N <br />E <br />S <br />W <br />45° <br />135°225° <br />315° <br />N <br />E <br />S <br />W <br />45° <br />135°225° <br />315° <br />N <br />E <br />S <br />W <br />45° <br />135°225° <br />315° <br />N <br />E <br />S <br />W <br />45° <br />135°225° <br />315° <br />N <br />E <br />S <br />W <br />45° <br />135°225° <br />315°INV3-1 <br />INV1-1 <br />INV1-2 <br />INV1-3 <br />INV1-4 INV2-1 <br />INV2-2 <br />INV2-3 <br />INV2-4 INV2-5 <br />INV3-2 <br />INV3-3 <br />INV3-4 <br />INV3-5 <br />INV4-2 <br />INV4-3 <br />INV5-1 <br />INV5-2 <br />INV5-3 <br />CARPORT #1 <br />CARPORT #2 <br />CARPORT #3 <br />CARPORT #4 <br />CARPORT #5 <br />INV4-1 <br />INV1-5 <br />INV3-6 <br />INV3-7 <br />INV6-2 <br />INV6-3 <br />INV5-5 <br />TO CARPORT #5 <br />INV5-4 <br />INV5-6 <br />INV5-6 <br />INV6-1 <br />1901 N Fairview St & Bldg A, B, <br />C, F & 1919 N Fairview St Bldg E <br />4/11/2024