Laserfiche WebLink
CUSTOMER <br />DATE: <br />SCALE: <br />SHEET # <br />CUSTOMER <br />E-8.2 <br />APN <br />PLAN SET REVISIONS <br />399-031-24 / 399-031-23 <br />6/8/2023 <br />SAMUELI ACADEMY <br />1901/1919 N. FAIRVIEW ST. <br />SANTA ANA, CA. 92705 <br />CONTRACTOR SIGNATURE: <br />DAVID CLEVELAND <br />CO <br />N <br />T <br />R <br />A <br />C <br />T <br />O <br />R <br />' <br />S <br /> <br />L <br />I <br />C <br />E <br />N <br />S <br />E <br /> <br /># <br /> <br />1 <br />0 <br />8 <br />9 <br />1 <br />1 <br />7 <br />CO <br />N <br />T <br />R <br />A <br />C <br />T <br />O <br />R <br />' <br />S <br /> <br />L <br />I <br />C <br />E <br />N <br />S <br />E <br /> <br /># <br /> <br />1 <br />0 <br />8 <br />9 <br />1 <br />1 <br />7 <br />DRAWN BY: <br />CHECKED BY: <br />APPROVED BY: <br />ENGINEER STAMP <br /> GROUNDING DETAILS <br />ILSCO <br />GBL-4DBT OR EQUIVALENT <br />(SS) 10-32 HEX <br />WASHER HEAD SCREW <br />TORQUE NUT / BOLT ASSEMBLY <br />TO 35 IN-LBS <br />(SS) SPLIT WASHER <br />(SS) FLAT WASHERPURLIN / RAIL <br />(SS) TOOTHED <br />WASHER WITH DEOX <br />(SS) #10-32 NUT <br />DRILLED OUT TO 7/32" <br />FOR RAIL <br />G <br />2 (TYP.) <br />(TYP.) MODULE BONDING DEVICE <br />(TYP.) MODULE <br />1 <br />2 (TYP.) <br />(TYP.) RAIL <br />(TYP.) #8 AWG CU BONDING JUMPER <br />BETWEEN RAILS <br />2 (TYP.) <br />SEE E-9 <br />(TYP.) INVERTER <br />SEE E-9 FOR GROUND <br />WIRE SIZE <br />(TYP.) INSTALL #8 AWG CU GROUND <br />FROM RAIL TO INVERTER <br />ARRAY GROUNDING DETAIL - CBC STEEL SCALE: N.T.S. <br />KEYNOTES <br />1. ALL BONDS BETWEEN MOUDLE FRAMES AND RACKING SYSTEM <br />SHALL BE UL 2703 LISTED. PROVIDE LISTED BONDING DEVICE(S) AT <br />EACH MODULE PER RACKING INSTALLATION MANUAL AND/OR <br />STRUCTURAL DRAWINGS. WHEN STRUCTURAL CARPORT PLANS DO <br />NOT SPECIFY LISTED BONDING DEVICE, PROVIDE (1) WEEB-DSK OR <br />EQUIVALENT AT EACH MODULE AND INSTALL PER WEEB <br />INSTALLATION MANUAL. THE CORRECT WEEB-DSK SIZE IS BASED ON <br />THE MOUNTING HARDWARE REQUIRED. SEE STRUCTURAL DRAWINGS <br />FOR DETAILS. <br />2. BOND ALL RAILS OR ROOFTOP RACKING SYSTEMS TOGETHER USING <br />#8 AWG CU BONDING JUMPER OR FACTORY-PROVIDED BONDING <br />JUMPER. WHERE RACKING INSTALLATION MANUAL AND/OR <br />STRUCTURAL DRAWINGS DO NOT SPECIFY THE WIRE TERMINATION <br />METHOD, USING DETAIL GD ON THIS PLAN. <br />3. CONTRACTOR TO DETERMINE DESIRED PATH FOR DC CONDUITS. FOR <br />DC CONDUIT SIZES BASED ON NUMBER OF CONDUCTORS, PLEASE <br />REFER TO KEYNOTE #2 ON SHEET E-9. <br />GROUND LUG DETAIL SCALE: N.T.S. <br />ILSCO LUG TORQUE VALUES <br />SIZE* AWG TORQUE IN-LB <br />10 20 <br />8 25 <br />6 35 <br /># <br />1 <br />CANOPY STRUCTURAL <br />COLUMN <br />CAST-IN-PLACE ANCHOR <br />BOLT <br />#2 CU EXOTHERMICALLY <br />BONDED TO COLUMN AND <br />REBAR CAGE. <br />GRADE <br />REBAR CAGE <br />VERTICAL <br />REINFORCEMENT <br />TIE WIRE FOR REBAR <br />CAGE ASSEMBLY <br />(TYPICAL) <br />TIE WIRE BONDING ANCHOR BOLTS <br />TO REBAR CAGE FOR CANOPY <br />STRUCTURE BONDING TO <br />CONCRETE ENCASED ELECTRODE <br />[PER NEC 250.52(A)(3)(1)] <br />CONDUITS OUT <br />ENCLOSURE GROUND BAR <br />GROUNDING <br />BUSHINGS <br />REPRESENTATIVE <br />CONDUCTORS <br />GROUND BUSHING <br />WITH LAY-IN LUG <br />LOCK OUT NUT <br />COMPRESSION FITTING <br />CONDUIT <br />ENCLOSURE WALL <br />GROUND LUGS USED <br />OUTDOORS MUST BE WET <br />RATED <br />CONTINUOUS BONDING <br />JUMPER, STRIP INSULATION <br />AT LUG, ALTERNATIVELY, <br />THE EGC MAY BE USED <br />(AS SHOWN) <br />PULL BOX / THROUGH GROUNDING SCALE: N.T.S.CANOPY / CARPORT COLUMN GROUNDING DETAIL SCALE: N.T.S. <br />CONDUIT BUSHING GROUNDING SCALE: N.T.S. <br />J.D. 12-01-22 <br />S.M. 05-02-23 <br />B.B. 05-02-23 <br />N.T.S. <br />G <br />2 (TYP.) <br />(TYP.) MODULE BONDING DEVICE <br />(TYP.) MODULE <br />1 <br />2 (TYP.) <br />(TYP.) RAIL <br />(TYP.) #8 AWG CU BONDING JUMPER <br />BETWEEN RAILS <br />SEE E-9 <br />(TYP.) INVERTER <br />SEE E-9 FOR GROUND <br />WIRE SIZE <br />(TYP.) INSTALL #8 AWG CU GROUND <br />FROM RAIL TO INVERTER <br />ARRAY GROUNDING DETAIL - PANELCLAW SCALE: N.T.S. <br />G <br />2 (TYP.) <br />(TYP.) MODULE BONDING DEVICE <br />(TYP.) MODULE <br />1 <br />2 (TYP.) <br />(TYP.) RAIL <br />SEE E-9 <br />(TYP.) INVERTER <br />SEE E-9 FOR GROUND <br />WIRE SIZE <br />(TYP.) INSTALL #8 AWG CU GROUND <br />FROM RAIL TO INVERTER <br /> ARRAY GROUNDING DETAIL - IRONRIDGE SCALE: N.T.S. <br />(TYP.) #8 AWG CU BONDING JUMPER <br />BETWEEN RAILS <br />1901 N Fairview St & Bldg A, B, <br />C, F & 1919 N Fairview St Bldg E <br />4/11/2024