Laserfiche WebLink
CITY OF SANTA ANA <br />Planning and Building Agency <br />1WIf IIfW <br />Hilt! PROFIS Engineering 3.1.23 <br />www.hilti.coin <br />Company: <br />Address: <br />Phone I Fax: <br />Design: <br />Fastening point: <br />7 Installation data <br />I <br />Concrete - Oct 15, 2025 <br />Profile: no profile <br />Hole diameter in the fixture: df = 0,562 in. <br />Plate thickness (input): 0.375 in. <br />Recommended plate thickness: not calculated <br />Drilling method: Hammer drilled <br />Cleaning: Manual cleaning of the drilled hole according to instructions for use is <br />required. <br />Page: <br />Specifier: <br />E-Mall: <br />Date: <br />Date: <br />Approved <br />PERMIT ISSUANCE <br />Anchor type and diameter: Kwik Bolt TZ2 - CS 112 (2 1/2) <br />hnom3 <br />Item number: 2210255 KB-TZ2 1/2x4 1/2 <br />Maximum installation torque: 602 in.ib <br />Hole diameter in the base material: 0.500 in. <br />Hole depth in the base material: 3.250 in. <br />Minimum thickness of the base material: 5.000 in. <br />Hilt! 0 112 in Kwik Bolt TZ2 - CS with 3 in nominal embedment depth per ICC-ES ESR-4266 , Hammer drill bit installation per MPII <br />7.1 Recommended accessories <br />Drilling Cleaning Setting <br />• Suitable Rotary Hammer • Manual blow-out pump • Torque controlled cordless impact tool <br />• Properly sized drill bit • Torque wrench <br />• Hammer <br />K <br />Coordinates Anchor [in.] <br />Anchor x y c_x c,x c_y c+ <br />1 -2.561 1.576 <br />2 2.561 -1,576 - <br />Input data and results must be checked for conformity with the existing conditions and for plausibility! <br />PROFIS Engineering (c) 2003-2025 Hilti AG, FL-9494 Schoen Hill! is a registered Trademark of HIM AG, Schaan <br />7 <br />