1. IF ANY OUTLETS CANNOT BE INSTALLED AS NOTED OR AS SHOWN ON PLANS DUE TO CONFLICTS WITH
<br />STRUCTURAL, MECHANICAL OR ELECTRICAL CONDITIONS, CLARIFY WITH HENDY BEFORE PROCEEDING
<br />WITH OUTLETS IN QUESTION OR RELATED OUTLETS IN AREA.
<br />2. ARCHITECTURAL DRAWINGS GOVERN OUTLET LOCATIONS. VERIFY ANY DISCREPANCIES WITH HENDY.
<br />3. CONTRACTOR TO REFER TO ELECTRICAL ENGINEERING DRAWINGS FOR CONDUIT SIZE & DEVICE
<br />SPECIFICATIONS, NO DEVICE OR CONDUIT SUBSTITUTIONS OR SIZE REDUCTIONS ARE ACCEPTABLE.
<br />4. FOR CIRCUITING INFORMATION AND PULL BOX LOCATIONS, REFER TO ELECTRICAL ENGINEERING
<br />DRAWINGS.
<br />5. ALL NEW CIRCUITS SHALL BE LABELED ON THE PROPER BUILDING ELECTRICAL PANEL DIRECTORIES.
<br />6. PROVIDE ELECTRICAL REQUIREMENTS AS NEEDED FOR MECHANICAL AND PLUMBING EQUIPMENT SEE
<br />ENGINEERING DRAWINGS.
<br />7. NON-DIMENSIONED OUTLETS SHALL BE LOCATED AT THE NEAREST STUD. ALL OUTLET DIMENSIONS SHALL
<br />BE CENTERLINE U.N.O. ALL OUTLET HEIGHTS NOTED ARE TO THE CENTERLINE OF THE RECEPTACLE,
<br />U.N.O. (SEE TYPICAL POWER AND COMMUNICATION LOCATIONS DIAGRAM).
<br />8. WHERE OUTLETS ARE GROUPED TOGETHER, THEY SHALL BE NO MORE THAN 2 INCHES APART. GANG
<br />WITH COMMON MOUNTING BRACKET AND/OR FACEPLATE WHENEVER POSSIBLE.
<br />9. PROVIDE CODE REQUIRED PROTECTION AT ALL OUTLETS AND SWITCHES LOCATED IN RATED PARTITIONS.
<br />10. ALL WALL OUTLETS LOCATED IN PRIVATE OFFICES & CONFERENCE ROOMS SHALL HAVE SOUND PADS,
<br />SEE TYPICAL WALL OUTLET SPACING DIAGRAM.
<br />11. MARK LOCATIONS OF ALL FLOOR MOUNTED RECEPTACLES AND REVIEW WITH HENDY PRIOR TO
<br />PROCEEDING WITH CORING/TRENCHING.
<br />12. SCHEDULE THE CORING OF ANY FLOOR OUTLETS WITH LANDLORD TO PREVENT DISTURBANCE OR
<br />DAMAGE TO OTHER TENANT SPACES.
<br />13. CONTRACTOR TO VERIFY WITH LANDLORD IF X-RAY IS REQUIRED PRIOR TO CORE DRILLING.
<br />14. ALL CONDUITS INSTALLED FROM A FLOOR POKE THROUGH FOR VOICE/DATA CABLING SHALL BE RUN TO 6"
<br />ABOVE THE SUSPENDED CEILING AT THE NEAREST WALL/COLUMN IN THE DIRECTION OF THE
<br />APPROPRIATE MDF/IDF ROOM EXCEPT AS WHERE IMPOSSIBLE DUE TO CEILING
<br />RESTRICTIONS/BLOCKAGES.
<br />15. PROVIDE CONDUITS OVER HARD LID CEILING & THRU-RATED WALLS FOR TENANT CABLING, LOCATIONS &
<br />SIZES SHALL BE VERIFIED WITH ELECTRICAL ENGINEERING DRAWINGS & TENANT CABLING INSTALLER.
<br />16. CONDUIT ABOVE CEILING SHALL BE SELF-SUPPORTED AND HELD TIGHT TO STRUCTURE A MINIMUM OF 6"
<br />ABOVE GRID, COORDINATE WITH LIGHT FIXTURE AND EQUIPMENT REQUIRED CLEARANCES.
<br />17. GENERAL CONTRACTOR SHALL COORDINATE WORK WITH TENANT'S CABLING CONTRACTORS.
<br />18. CABLING SHALL BE PLENUM RATED AND SUPPORTED INDEPENDENT OF THE SUSPENDED CEILING. ALL
<br />CABLING SHALL BE PROVIDED AND INSTALLED BY TENANT'S VENDOR.
<br />19. WHERE ELECTRICAL WORK IS SPECIFIED IN CONJUNCTION W ITH MILLWORK, ALL OUTLETS, CONDUITS ND
<br />FIXTURES SHALL BE PROVIDED BY GENERAL CONTRACTOR. CUT OUTS FOR SWITCHES, OUTLETS, ETC.
<br />SHALL BE PROVIDED BY THE MILLWORK CONTRACTOR AND SHALL BE COORDINATED WITH THE
<br />ELECTRICAL CONTRACTOR, U.N.O.
<br />20. FURNITURE SYSTEMS SHALL BE SUPPLIED AND INSTALLED BY TENANT'S VENDOR. ELECTRICAL
<br />CONTRACTOR SHALL MAKE FINAL HARDWIRE CONNECTION AND IS RESPONSIBLE FOR ALL REQUIRED
<br />PERMITS/INSPECTIONS.
<br />21. ISOLATED GROUND RECEPTACLE SHALL BE ORANGE WITH BUILDING STANDARD COVER PLATES.
<br />22. TELEPHONE DATA CONTRACTOR SHALL COORDINATE DEVICE LOCATION WITH HENDY PRIOR TO
<br />INSTALLATION.
<br />1. REFER TO IA-9.1 SHEET FOR RESTROOM PLUMBING REQUIREMENTS.
<br />2. REFER TO MILLWORK ELEVATIONS FOR EXACT PLUMBING LOCATIONS.
<br />3. KITCHEN SINKS SHALL HAVE A LEVER, PUSH TYPE OR ELECTRONICALLY OPERATED FAUCETS, WITH A 5
<br />LBS. MAXIMUM OPENING FORCE. SELF CLOSING FAUCETS SHALL REMAIN OPEN 10 SECONDS MINIMUM.
<br />1. ALL EQUIPMENT IN PLENUM SHALL BE LOCATED AWAY FROM GYP. BD. CEILINGS WHENEVER
<br />POSSIBLE. NO ACCESS HATCHES IN GYP. BD. CEILING WITHOUT PRIOR APPROVAL BY ARCHITECT.
<br />ACCESS HATCHES SHALL BE A TRIMLESS TYPE. SUBMIT CUT SHEET FOR APPROVAL.
<br />2. PROVIDE AND INSTALL CONDUITS OVER GYP. BD. CEILINGS, THROUGH FULL HEIGHT WALLS AND
<br />THROUGH RATED CORRIDORS TO NEAREST ACCESSIBLE CEILING FOR TENANT'S CABLING. CONDUIT
<br />SIZE AND LOCATION SHALL BE VERIFIED PRIOR TO INSTALLATION.
<br />3. EXCEPT WHERE RIGID BRACES ARE USED TO LIMIT LATERAL DEFLECTIONS, SPRINKLER HEADS AND
<br />OTHER PENETRATIONS SHALL HAVE A 2 INCH OVERSIZE RING SLEEVE OR ADAPTER THROUGH THE
<br />CEILING TILE TO ALLOW FOR FREE MOVEMENT OF AT LEAST 1 INCH IN ALL HORIZONTAL DIRECTIONS.
<br />ALTERNATIVELY, A SWING JOINT THAT CAN ACCOMMODATE 1 INCH OF CEILING MOVEMENT IN ALL
<br />HORIZONTAL DIRECTIONS IS PERMITTED SHALL BE PROVIDED AT THE TOP OF THE SPRINKLER HEAD
<br />EXTENSION.
<br />4. INSTALL SUSPENDED CEILING SYSTEMS IN ACCORDANCE WITH CBC CHAPTERS 8 AND 25.
<br />5. SUSPENDED CEILING FRAMING SYSTEMS SHALL BE DESIGNED TO RESIST A LATERAL FORCE OF 20%
<br />OF THE WEIGHT OF THE CEILING ASSEMBLY AND ANY LOADS TRIBUTARY TO THE SYSTEM. FOR THE
<br />PURPOSES OF DETERMINING THE LATERAL FORCE, A MINIMUM CEILING WEIGHT OF 5 LBS PER
<br />SQUARE FOOT SHALL BE USED. WHERE THE CEILING LOADS DO NOT EXCEED 5 LBS PER SQUARE
<br />FOOT AND WHERE PARTITIONS ARE NOT CONNECTED TO THE CEILING SYSTEM, THE FOLLOWING
<br />BRACING METHOD MAY BE EMPLOYED:
<br />a.LATERAL SUPPORT MAY BE PROVIDED BY FOUR WIRES OF MINIMUM NO. 8 GAUGE SPLAYED IN
<br />FOUR DIRECTIONS 90 DEGREES APART, AND CONNECTED TO THE MAIN RUNNER WITHIN 2'' OF
<br />THE CROSS RUNNER AND TO THE STRUCTURE ABOVE AT AN ANGLE NOT EXCEEDING 45
<br />DEGREES FROM THE PLANE OF THE CEILING. THESE LATERAL SUPPORT POINTS SHALL BE
<br />PLACED 12 FT. O.C. IN EACH DIRECTION WITH THE FIRST POINT WITHIN 6 FT. FROM EACH
<br />WALL.
<br />b.ALLOWANCE SHALL BE MADE FOR LATERAL MOVEMENT OF THE SYSTEM WITH CLEARANCE
<br />BETWEEN THE WALL AND THE RUNNERS MAINTAINED AT THE OTHER TWO WALLS.
<br />c.VERTICAL SUPPORT SHALL BE PROVIDED AS REQUIRED IN CBC CHAPTER 8 WITH THE ADDED
<br />REQUIREMENT THAT DISCONTINUOUS ENDS OF CROSS RUNNERS AND MAIN RUNNERS BE
<br />VERTICALLY SUPPORTED WITHIN 8'' OF SUCH DISCONTINUITIES AS MAY OCCUR WHERE THE
<br />CEILING IS DISRUPTED BY A WALL.
<br />d.A STRUT FASTENED TO THE MAIN RUNNER SHALL EXTEND TO AND FASTENED TO THE
<br />STRUCTURAL MEMBERS SUPPORTING THE ROOF OR FLOOR ABOVE AT 12'-0”O.C. IN BOTH
<br />DIRECTIONS AND WITHIN 6'-0”FROM WALLS.
<br />6. SUSPENDED ACOUSTICAL CEILING SYSTEM PERIMETER SUPPORTING CLOSURE ANGLE SHALL BE NOT
<br />LESS THAN 2 INCHES IN EACH ORTHOGONAL HORIZONTAL DIRECTION. ONE END OF THE CEILING GRID
<br />SHALL BE ATTACHED TO THE CLOSURE ANGLE. THE OTHER END IN EACH HORIZONTAL DIRECTION
<br />SHALL HAVE A 3/4 INCH CLEARANCE FROM THE WALL AND SHALL REST UPON AND BE FREE TO SLIDE
<br />ON A CLOSURE ANGLE.
<br />7. REMOVE AND REPLACE EXISTING CEILING GRID AND TILES AS REQUIRED FOR INSTALLATION OF VAV
<br />BOXES, MECHANICAL DUCTS, AND/OR AC UNITS.
<br />1. SPRINKLER HEADS LOCATED IN GYP. BD. CEILINGS SHALL BE FULLY RECESSED AND FACTORY
<br />PAINTED TO MATCH CEILING. DISTRIBUTION OF HEADS MUST MEET GOVERNING CODES.
<br />2. SPRINKLER HEADS LOCATED IN SUSPENDED ACOUSTICAL CEILING SYSTEMS SHALL BE SEMI-
<br />RECESSED ADJUSTABLE HEADS. DISTRIBUTION OF HEADS MUST MEET GOVERNING CODES.
<br />HEADS SHALL BE LOCATED IN CENTER OF CEILING TILE, U.N.O. (EXCEPT AS CODE REQUIRED NEAR
<br />SOFFIT). CONFIRM EXISTING SPRINKLER HEAD LOCATIONS.
<br />1. LOCATE RECESSED DOWNLIGHTS, WALL WASHERS, PENDANTS, AND ACCENT LIGHTS IN THE CENTER OF
<br />CEILING TILES, U.N.O.
<br />2. LIGHT SENSOR AND LIGHT SWITCH LOCATIONS SHALL BE APPROVED BY ARCHITECT PRIOR TO INSTALLATION.
<br />3. ALL STROBES SHALL BE LOCATED IN CEILING WHERE ALLOWABLE BY CODE. COLOR SHALL BE APPROVED BY
<br />ARCHITECT.
<br />4. THE COLOR AND DESIGN OF LETTERING, ARROWS AND OTHER SYMBOLS ON THE EXIT SIGN SHALL BE IN HIGH
<br />CONTRAST WITH THEIR BACKGROUND. WORDS ON THE SIGN SHALL BE IN BLOCK LETTERS 6 INCHES IN
<br />HEIGHT WITH A STROKE OF NOT LESS THAN 3/4" INCH. MATCH BUILDING STANDARD, UNLESS NOTED
<br />OTHERWISE.
<br />5. THE MEANS OF EGRESS ILLUMINATION LEVEL SHALL NOT BE LESS THAN 1 FOOT-CANDLE AT THE WALKING
<br />SURFACE LEVEL.
<br />6. THE EMERGENCY POWER SYSTEM SHALL PROVIDE POWER FOR A DURATION NOT LESS THAN 90 MINUTES
<br />AND SHALL CONSIST OF STORAGE BATTERIES, UNIT EQUIPMENT OR AN ON-SITE GENERATOR. THE
<br />INSTALLATION OF THE EMERGENCY POWER SYSTEM SHALL BE IN ACCORDANCE WITH CBC 2702 AND
<br />ILLUMINATE THE FOLLOWING AREAS:
<br />A.AISLES AND UNENCLOSED EGRESS STAIRWAYS IN ROOMS AND SPACES THAT REQUIRE TWO OR
<br />MORE MEANS OF EGRESS.
<br />B.CORRIDORS, EXIT ENCLOSURES AND EXIT PASSAGEWAYS IN BUILDINGS REQUIRED TO HAVE TWO OR
<br />MORE EXITS.
<br />C.EXTERIOR EGRESS COMPONENTS AT ALL LEVELS OTHER THAN THE LEVEL OF EXIT DISCHARGE UNTIL
<br />EXIT DISCHARGE IS ACCOMPLISHED FOR BUILDINGS REQUIRED TO HAVE TWO OR MORE EXITS.
<br />D.INTERIOR EXIT DISCHARGE ELEMENTS, AS REQUIRED BY CBC SECTION 1028.1, IN BUILDINGS
<br />REQUIRED TO HAVE TWO OR MORE EXITS.
<br />E.EXTERIOR LANDINGS FOR EXIT DISCHARGE DOORWAYS IN BUILDINGS REQUIRED TO HAVE TWO OR
<br />MORE EXITS.
<br />7. LIGHTING FIXTURES SHALL BE SUPPORTED DIRECTLY BY WIRES TO THE STRUCTURE ABOVE. RECESSED
<br />LIGHTING FIXTURES NOT OVER 56 LBS IN WEIGHT AND PENDANT HUNG FIXTURES NOT OVER 20 LBS IN
<br />WEIGHT MAY BE SUPPORTED AND ATTACHED DIRECTLY TO THE CEILING SYSTEM RUNNERS BY A POSITIVE
<br />ATTACHMENT SUCH AS SCREWS OR BOLTS. THESE REQUIREMENTS ARE BASED ON CURRENT CALIFORNIA
<br />BUILDING CODES. OTHER METHODS MAY BE USED PROVIDED THEY ARE SUBSTANTIATED BY DESIGN
<br />CALCULATIONS USING THE LOADS SPECIFIED IN CBC CHAPTER 25.
<br />1. ELEVATORS SHALL COMPLY WITH ALL CURRENT CALIFORNIA BUILDING CODE SECTIONS.
<br />2. ELEVATOR SHALL OPERATE AUTOMATICALLY.
<br />3. CAB SHALL BE SELF-LEVELING TO A TOLERANCE OF 1/2" VERTICAL WITH A MAXIMUM GAP BETWEEN
<br />PLATFORM SILL AND EDGE OF HOISTWAY OF 1-1/4" HORIZONTAL BETWEEN CAR AND LANDING.
<br />4. CALL BUTTONS SHALL BE CENTERED AT 42 INCHES A.F.F. WITH BUTTONS A MINIMUM OF 3/4" DIA. AND
<br />RAISED 1/8".
<br />5. VISUAL INDICATOR TO SHOW EACH CALL REGISTERED AND ANSWERED.
<br />6. VISUAL SIGNALS AT EACH HOISTWAY ENTRANCE SHOWING CAR ARRIVAL AND DIRECTION SHALL BE 2-1/2"
<br />AND CENTERLINE AT 6'-0”MINIMUM ABOVE FLOOR AND VISIBLE FROM PROXIMITY OF CALL BUTTON.
<br />7. AUDIBLE INDICATORS ANNOUNCING CAR ARRIVAL AND TRAVEL DIRECTION SHALL SOUND ONCE FOR UP
<br />AND TWICE FOR DOWN.
<br />8. BOTH HOISTWAY JAMBS AT EACH FLOOR SHALL HAVE SIGNAGE AT 5'-0" A.F.F. INDICATING FLOOR NUMBER IN
<br />RAISED CHARACTERS THAT ARE MINIMUM 2 INCHES HIGH ON CONTRASTING BACKGROUND. PROVIDE 2
<br />INCHES DIA. FIVE POINT STAR TO LEFT OF CHARACTER ON MAIN ENTRY LEVEL. BRAILLE SHALL BE PLACED
<br />BELOW CORRESPONDING CHARACTERS.
<br />9. AUTOMATIC DOORS SHALL BE MINIMUM 36" WIDE.
<br />10. CAR SIZE SHALL BE A MINIMUM OF 80”X 54”FOR CENTER OPENING DOORS AND 68”X 54”FOR SIDE-SLIDE
<br />OPENING DOORS.
<br />11. CAR CONTROL BUTTONS SHALL BE 48 INCHES A.F.F. FOR FRONT APPROACH OR 54 INCHES A.F.F. FOR SIDE
<br />APPROACH WITH EMERGENCY CONTROLS NO LOWER THAN 35" A.F.F. AND ADJACENT TO OR IN BOTTOM OF
<br />BUTTON PANEL.
<br />12. EMERGENCY TWO-WAY COMMUNICATION SYSTEM SHALL BE NO MORE THAN 48 INCHES A.F.F. WITH THE
<br />HANDSET CORD A MINIMUM OF 29" IN LENGTH. EMERGENCY INTERCOMMUNICATION SHALL NOT REQUIRE
<br />VOICE COMMUNICATION.
<br />13. HANDRAIL SHALL BE LOCATED ON ONE WALL, PREFERABLY REAR MOUNTED, AT 32”A.F.F. AND 1-1/2”FROM
<br />WALL.
<br />14. DOOR REOPENING DEVICE SHALL BE ACTIVATED WHEN OBSTRUCTION IS SENSED BETWEEN 5"-29" ABOVE
<br />THE FLOOR WITHOUT CONTACT AND REMAIN EFFECTIVE FOR A MINIMUM OF 20 SECONDS.
<br />15. DOOR DELAY TIME SHALL BE NOT LESS THAN CALCULATED BY T=D/(1.5 FT/S) WHERE “T”IS TIME IN SECONDS
<br />AND “D”IS THE DISTANCE FROM A POINT IN THE LOBBY OR LANDING AREA 60 INCHES DIRECTLY IN FRONT OF
<br />THE FARTHEST CALL BUTTON CONTROLLING THE CAR TO CENTERLINE OF ITS HOISTWAY DOOR.
<br />16. MINIMUM ACCEPTABLE TIME FOR THE DOORS TO REMAIN FULL OPEN IS NOT LESS THAN FIVE SECONDS.
<br />17. MINIMUM ILLUMINATION REQUIRED AT CAR CONTROLS THRESHOLD AND LANDING WHEN CAR AND LANDING
<br />DOORS ARE OPEN IS 5 FOOTCANDLES.
<br />18. PASSENGER ELEVATOR CAR CONTROL BUTTON SHALL BE ILLUMINATED, HAVE SQUARE SHOULDERS, BE
<br />MINIMUM 3/4" IN DIMENSION AND RAISED 1/8".
<br />19. CONTROL BUTTONS SHALL BE DESIGNATED BY 5/8" MINIMUM RAISED CHARACTERS AND STANDARD SYMBOL
<br />IMMEDIATELY TO THE LEFT OF THE CONTROL BUTTON. GRADE 2 BRAILLE SHALL BE LOCATED IMMEDIATELY
<br />BELOW THE CHARACTER OR SYMBOL.
<br />1. PROVIDE HVAC DISTRIBUTION TO ACCOMMODATE PROPOSED LAYOUT, PEOPLE & EQUIPMENT LOADS AS REQUIRED.
<br />2. VERIFY ALL THERMOSTAT LOCATIONS PRIOR TO INSTALLATION, LOCATIONS SHALL NOT CONFLICT WITH TENANT'S
<br />FURNITURE.
<br />3. PROVIDE SEPARATE ZONES WITH THERMOSTATS IN ALL CONFERENCE ROOMS SEATING MORE THAN 6 PEOPLE AND ALL
<br />ROOMS WITH EXTERIOR GLAZING ON TWO SIDES.
<br />4. PROVIDE A DEDICATED 24/7 HVAC UNIT IN IDF ROOM. REFER TO MECHANICAL ENGINEERING PLANS FOR MORE
<br />INFORMATION. HVAC UNIT SHALL BE OUTSIDE OF ROOM & DUCTED IN.
<br />5. PROVIDE FIRE DAMPERS AT PENETRATIONS TO ALL FIRE RATED PARTITIONS.
<br />6. PROVIDE SOUND BOOTS ON ALL RETURN AIR DUCTS IN FULL HEIGHT WALLS.
<br />7. ALL SUPPLY & RETURN AIR DIFFUSERS SHALL MATCH BUILDING STANDARD.
<br />8. PROVIDE LINEAR DIFFUSERS IN GYPSUM BOARD LOCATIONS. ALL LINEAR DIFFUSERS SHALL BE TRIMLESS TYPE.
<br />PROVIDE CUT SHEET FOR REVIEW.
<br />9. WHERE EXPOSED CEILINGS OCCUR, EXISTING VAV BOXES SHALL BE RELOCATED TO NEAREST SUSPENDED
<br />ACOUSTICAL CEILING AREA.
<br />1. ADHESIVES, GENERAL: DO NOT USE ADHESIVES THAT CONTAIN UREA FORMALDEHYDE.
<br />2. WOOD GLUE: PROVIDE ALIPHATIC-RESIN, POLYURETHANE, OR RESORCINOL WOOD GLUE RECOMMENDED BY
<br />MANUFACTURER FOR GENERAL CARPENTRY USE. VOC CONTENT SHALL NOT EXCEED 30 G/L WHEN
<br />CALCULATED ACCORDING TO 40 CFR 59, SUBPART D (EPA METHOD 24).
<br />3. MULTIPURPOSE CONSTRUCTION ADHESIVE: PROVIDE FORMULATION COMPLYING WITH ASTM D3498 THAT IS
<br />RECOMMENDED FOR INDICATED USE BY ADHESIVE MANUFACTURER. VOC CONTENT SHALL NOT EXCEED 70 G/L
<br />WHEN CALCULATED ACCORDING TO 40 CFR 59, SUBPART D (EPA METHOD 24).
<br />4. CONTACT ADHESIVE: PROVIDE PRODUCT RECOMMENDED FOR INDICATED USE BY MANUFACTURER. VOC
<br />CONTENT SHALL NOT EXCEED 250 G/L WHEN CALCULATED ACCORDING TO 40 CFR 59, SUBPART D (EPA
<br />METHOD 24).
<br />5. VOC CONTENT OF INTERIOR SEALANTS; PROVIDE SEALANTS AND SEALANT PRIMERS FOR USE INSIDE THE
<br />WEATHERPROOFING SYSTEM THAT COMPLY WITH THE FOLLOWING LIMITS FOR VOC CONTENT WHEN
<br />CALCULATED ACCORDING TO CFR 40 59, SUBPART D (EPA METHOD 24):
<br />A. ARCHITECTURAL SEALANTS: VOC LIMIT NOT MORE THAN 250 G/L.
<br />B. SEALANT PRIMERS FOR NON-POROUS SUBSTRATES: NOT MORE 250 G/L.
<br />C. SEALANT PRIMERS FOR POROUS SUBSTRATES: NOT MORE THAN 775 G/L.
<br />1. NO FINISH SUBSTITUTIONS MAY BE MADE WITHOUT PRIOR W RITTEN AUTHORIZATION BY HENDY.
<br />2. ALL FINISHES SHALL BE APPLIED IN STRICT ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS,
<br />UNLESS NOTED OTHERWISE, AND SHALL CONFORM TO CHAPTER 8 OF THE CALIFORNIA BUILDING CODE.
<br />3. APPLICATION OF CONTROLLED INTERIOR FINISHES SHALL BE IN ACCORDANCE WITH SECTIONS 803 AND
<br />804 OF THE CALIFORNIA BUILDING CODE.
<br />4. MAXIMUM FLAME SPREAD CLASSIFICATION OF FINISH MATERIALS USED ON INTERIOR WALLS AND
<br />CEILINGS SHALL NOT EXCEED THAT SET FORTH IN TABLE 803.9 OF THE CALIFORNIA BUILDING CODE.
<br />5. SMOKE DENSITY OF MATERIALS SHALL BE NO GREATER THAN 450 WHEN TESTED IN ACCORDANCE WITH
<br />SECTION 803 OF THE CALIFORNIA BUILDING CODE.
<br />1. FIELD VERIFY EXISTING CONDITION OF FLOORS RECEIVING FINISHES. ALL FLOORS SHALL BE CLEAN,
<br />DRY, FREE OF DUST, GREASE, WAX, CURING AGENTS, EXCESSIVE ALKALINITY, PAINT, OLD ADHESIVE
<br />AND ANY FOREIGN SUBSTANCE THAT WOULD PROHIBIT PROPER BONDING OF ANY FLOOR COVERING
<br />MATERIAL. CONTRACTOR SHALL INCLUDE ALL REQUIRED FLOOR PREPARATION IN BID. PROVIDE PRICE
<br />TO FLOAT FLOOR WHERE NECESSARY TO ACHIEVE TOLERANCE OF 1/4'' MAX. IN 10'-0'' SPAN.
<br />2. PREPARE ALL FLOORS TO RECEIVE FINISHES. PROVIDE CALCIUM CHLORIDE TESTING IN SEVERAL AREAS
<br />OF TENANT FLOOR AREA AND PROVIDE TEST RESULTS TO HENDY.
<br />3. ALL CONCRETE SUBFLOORS SHALL BE TREATED FOR MOISTURE PRIOR TO INSTALLATION OF ANY
<br />FLOOR COVERING. RATINGS SHALL BE IN ACCORDANCE WITH THOSE AS CONSIDERED ACCEPTABLE BY
<br />THE MANUFACTURER FOR THE SPECIFIED PRODUCTS. PROVIDE CORRECTIVE MEASURES AT
<br />SUBFLOORS EXCEEDING THESE MOISTURE RATINGS.
<br />4. SUBMIT SEAMING DIAGRAM WITH FLOORING SUBMITTAL.
<br />5. FLOORING SHALL EXTEND TO BACK WALL WHERE ACCESSIBLE SINK CABINETS OCCUR.
<br />6. FLOORING SHALL MEET ALL CURRENT NON-SLIP STANDARDS AND APPLICABLE CODES AND/OR
<br />AUTHORITY'S REQUIREMENTS. PROVIDE NON-SLIP COATINGS AS NECESSARY TO MEET THESE
<br />REQUIREMENTS.
<br />7. AFTER CLEANING, THE FLOORING CONTRACTOR SHALL PROVIDE (2) APPLICATIONS OF AN APPROVED
<br />NON-SLIP WAX TO ALL RESILIENT TILE FLOOR, WHICH SHALL BE THOROUGHLY MACHINE-BUFFED AND IN
<br />CONDITION ACCEPTABLE TO HENDY.
<br />8. ALL VINYL COMPOSITION TILES SHALL BE INSTALLED WITH FULL TILE FROM TRANSITION AT DOOR AND
<br />FULL TILE FROM WALL PERPENDICULAR TO DOOR, U.N.O.
<br />9. PROVIDE CORK RUBBER FLOOR TILE MADE WITH ADHESIVES AND BINDERS THAT DO NOT CONTAIN
<br />UREA-FORMALDEHYDE RESINS.
<br />10. PROVIDE CORK RUBBER FLOOR TILE WATER-RESISTANT ADHESIVE AS RECOMMENDED BY
<br />MANUFACTURER TO SUIT CORK RUBBER FLOORING AND SUBSTRATE CONDITIONS INDICATED. USE
<br />ADHESIVES THAT HAVE A VOC CONTENT OF NOT MORE THAN 50 G/L WHEN CALCULATED ACCORDING TO
<br />40 CFR 59, SUBPART D (EPA 24).
<br />11. PROVIDE SHEET VINYL FLOOR COVERING WATER RESISTANT ADHESIVE RECOMMENDED BY
<br />MANUFACTURER TO SUIT SUCH MATERIALS AND SUBSTRATE CONDITIONS. USE ADHESIVES THAT HAVE
<br />A VOC CONTENT OF NOT MORE THAN 50 G/L WHEN CALCULATED ACCORDING TO 40 CFR 59, SUBPART D
<br />(EPA 24).
<br />12. PROVIDE STATIC-CONTROL ADHESIVE PRODUCT THAT PRODUCES CONDUCTIVE CONTINUITY OF VCT
<br />AND ASPHALT TILE FLOOR COVERING SYSTEM WITH VOC CONTENT OF NOT MORE THAN 50 G/L WHEN
<br />CALCULATED ACCORDING TO 40 CFR 59, SUBPART D (EPA 24).
<br />13. FLOAT FLOOR AT TILE TO CARPET TRANSITIONS, RAMP IN DIRECTION OF CARPET.
<br />14. THE MAXIMUM PILE HEIGHT OF CARPET SHALL BE 1/4 INCH. EXPOSED EDGES OF CARPET SHALL BE
<br />FASTENED TO FLOOR SURFACES AND HAVE TRIM ALONG THE ENTIRE LENGTH OF THE EXPOSED EDGE.
<br />15. CARPET SHALL BE INSTALLED IN ACCORDANCE WITH GUIDELINES SET FORTH BY THE CARPET AND RUG
<br />INSTITUTE'S CURRENT STANDARD FOR INSTALLATION OF COMMERCIAL TEXTILE FLOOR COVERING
<br />MATERIALS. ALL SEAMS MUST BE PROPERLY SEALED USING A CONTINUOUS BEAD OF SEAM ADHESIVE
<br />LARGE ENOUGH TO COVER THE PRIMARY BACKING, YARN BUNDLES AND SECONDARY BACKING.
<br />16. PROVIDE CARPET TILE AND CUSHION PRODUCTS PER SPECIFICATION THAT COMPLY WITH TESTING AND
<br />PRODUCT REQUIREMENTS OF CARPET AND RUG INSTITUTE'S “GREEN LABEL PLUS”PROGRAM.
<br />17. PROVIDE CARPET ADHESIVES THAT ARE WATER RESISTANT, MILDEW RESISTANT, NON-STAINING, TYPE
<br />THAT SUIT PRODUCTS AND SUBFLOOR CONDITIONS INDICATED, THAT COMPLIES WITH FLAMMABILITY
<br />REQUIREMENTS FOR INSTALLED CARPET AND THAT IS RECOMMENDED BY THE MANUFACTURER. USE
<br />CARPET ADHESIVE WITH VOC CONTENT OF NOT MORE THAN 50 G/L L WHEN CALCULATED ACCORDING
<br />TO 40 CFR 59, SUBPART D (EPA 24).
<br />18. ALL CARPET INSTALLATION SHALL BE ACCOMPLISHED BY A FLOOR COVERING FIRM OR INSTALLER
<br />CERTIFIED BY THE FCIB, FCICA OR CFI; AND SHALL BE INSTALLED IN ACCORDANCE WITH THE
<br />MANUFACTURER'S INSTALLATION INSTRUCTIONS.
<br />19. PROVIDE TRANSITION STRIPS AS SPECIFIED AT ALL FLOORING TRANSITIONS. SUBMIT TRANSITION
<br />SAMPLE TO HENDY FOR REVIEW AND COLOR SELECTION.
<br />20. ALL TRANSITIONS AT DOORS TO OCCUR UNDER CENTERLINE OF DOOR IN CLOSED POSITION, U.N.O.
<br />TRANSITIONS AT CASED OPENINGS SHALL BE VERIFIED WITH HENDY.
<br />21. INSTALL WALL FINISH FOR THE FULL HEIGHT OF THE PARTITION WITHOUT BASE. THERE SHALL BE NO
<br />UNFINISHED GAPS OF GYP. BD. AT THE BASE.
<br />22. PROVIDE MINIMUM 2" WIDE X LENGTH OF STEP WARNING STRIPE IN CONTRASTING COLOR OF
<br />COORDINATING FLOORING AT FIRST AND LAST STAIR TREADS AS REQUIRED BY CODE.
<br />1. PAINT AND WALLCOVERING SUBCONTRACTORS SHALL EXAMINE WALLS PRIOR TO FINISH
<br />APPLICATION. BEGINNING WORK IMPLIES ACCEPTANCE OF THEIR CONDITION.
<br />2. ALL EXISTING WALLS SHALL BE PAINTED, U.N.O.
<br />3. PAINT AND PRIMERS SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S
<br />SPECIFICATION FOR THAT PARTICULAR SURFACE.
<br />4. PROVIDE INTERIOR PAINT PRODUCTS THAT COMPLY WITH THE FOLLOWING LIMITS FOR VOC
<br />CONTENT WHEN CALCULATED ACCORDING TO 40 CFR 59M SUBPART D (EPA METHOD 24):
<br />A.FLAT PAINTS, COATINGS, TOPCOATS, AND PRIMERS: VOC CONTENT < 50 G/L.
<br />B.NON-FLAT PAINTS, COATINGS, AND PRIMERS: VOC CONTENT < 150 G/L.
<br />C.FLOOR COATINGS: VOC CONTENT < 100 G/L.
<br />5.RESTRICTED COMPONENTS: PAINTS AND COATINGS SHALL NOT CONTAIN ANY OF THE FOLLOWING:
<br />ACROLEIN, ACRYLONITRILE, ANTIMONY, BENZENE, BUTYL BENZYL PHTHALATE, CADMIUM, DI (2-
<br />ETHYLHEXYL PHTHALATE, DI-N-BUTYL PHTHALATE, DI-N-OCTYL PHTHALATE, 1,2-
<br />DICHLOROBENZENE, DIETHYL PHTHALATE, DIMENTHYL PHTHALATE, ETHYLBENZENE,
<br />FORMALDEHYDE, HEXAVALENT CHROMIUM, ISOPHORONE, LEAD, MERCURY. METHYL ETHYL
<br />KETONE, METHYL ISOBUTYL KETONE, METHYLENE CHLORIDE, NAPHTHALENE, TOLUENE
<br />(METHYLBENZENE), 1,1,1-TRICLOROETHANE, VINYL CHLORIDE.
<br />6.ALL PAINTED WALLS SHALL RECEIVE ONE (1) PRIMER COAT AND TWO (2) COATS OF PAINT, U.N.O.
<br />PAINT FINISH SHALL HAVE CONSISTENT COVERAGE, FREE OF ROLLER OR BRUSH MARKS.
<br />7.WHERE PAINT COLORS CHANGE, CORNERS SHALL BE CUT-IN AND FREE OF OVERLAP.
<br />8.ALL GYP. BD. CEILINGS AND SOFFITS SHALL HAVE A LEVEL 5 FINISH AND RECEIVE TWO (2) COATS
<br />FLAT PAINT OVER (1) COAT PRIMER, U.N.O.
<br />9.PAINT FINISH ON METAL SURFACES INCLUDING DOOR FRAMES, HANDRAILS, ELEVATOR DOORS, ETC.
<br />SHALL BE SEMI-GLOSS, U.N.O.
<br />10.ALL METAL ACCESS DOORS SHALL BE PAINTED TO MATCH ADJACENT WALL OR CEILING FINISH.
<br />11.SUBMIT SEAMING MOCK-UP SAMPLES ON GYP. BD. OF ALL SPECIFIED WALLCOVERINGS TO HENDY
<br />FOR APPROVAL PRIOR TO PLACEMENT OF ORDER.
<br />12.ALL SURFACES RECEIVING WALLCOVERING SHALL BE PROPERLY PREPARED PER MANUFACTURER'S
<br />SPECIFICATIONS. PRIMER AND ADHESIVE SHALL BE FROM SAME MANUFACTURER OR OTHER
<br />APPROVED/ COMPATIBLE PRODUCTS.
<br />13.PROVIDE WALLCOVERING ADHESIVE THAT IS MILDEW RESISTANT AND NON-STAINING FOR USE WITH
<br />SPECIFIC WALLCOVERING AND SUBSTRATE APPLICATION, AS RECOMMENDED IN WRITING BY
<br />WALLCOVERING MANUFACTURER. USE WALLCOVERING ADHESIVE WITH VOC CONTENT OF NOT
<br />MORE THAN 50 G/L WHEN CALCULATED ACCORDING TO 40 CFR 59, SUBPART D (EPA 24).
<br />14.COORDINATE WALLCOVERING INSTALLATION IN OR ON MILLWORK WITH SUB-CONTRACTORS.
<br />15.WALLCOVERING SHALL BE HUNG IN SEQUENCE AND FROM SAME DYE LOT.
<br />16.POLYOLEFIN WALLCOVERING SHALL RECEIVE SCOTCH GUARD APPLICATION IF NOT FACTORY
<br />APPLIED.
<br />17.INSTALL WALLCOVERING PER MANUFACTURER'S SPECIFICATIONS. WALLCOVERING SHALL BE
<br />INSTALLED SMOOTH, WITHOUT WRINKLES, BUBBLES OR LOOSE EDGES. ALL PASTE AND BRUSH
<br />MARKS SHALL BE REMOVED. WALL COVERING TERMINATIONS SHALL BE CUT STRAIGHT AND
<br />SQUARE. WALLCOVERING AT ALL REVEALS SHALL RETURN INTO REVEAL, U.N.O.
<br />18.INSTALL BASE LENGTHS AS LONG AS POSSIBLE. WRAP BASE AROUND CORNER AND CONTINUE A
<br />MIN. OF 6 INCHES BEYOND BEFORE SEAMING OR USE PRE-FORMED CORNER PIECES.
<br />19.COORDINATE THE INSTALLATION OF WALL BASE WITH MILLWORK. OMIT BASE WHERE BUILT-IN
<br />CABINETS ARE INDICATED. PROVIDE BASE AT BACK WALL INSIDE ACCESSIBLE SINK CABINET.
<br />1. COMPLY WITH TCNA'S "HANDBOOK FOR CERAMIC, GLASS, AND STONE TILE INSTALLATION" METHODS
<br />AND WITH PARTS OF ANSI A108 SERIES" SPECIFICATIONS FOR INSTALLATION OF CERAMIC TILE" THAT
<br />RE REFERENCE IN TCNA INSTALLATION METHODS. APPLY TO TYPES OF SETTING AND GROUTING
<br />MATERIALS USED.
<br />2. EXAMINE TILE SUBSTRATES, AREAS, AND CONDITIONS FOR COMPLIANCE WITH INSTALLATION
<br />TOLERANCES AND OTHER CONDITIONS AFFECTING THE WORK. PROCEED WITH INSTALLATION ONLY
<br />AFTER UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. FILL CRACKS, HOLES, AND
<br />DEPRESSIONS IN CONCRETE SUBSTRATES WITH TROWELABLE LEVELING AND PATCHING COMPOUND
<br />SPECIFICALLY RECOMMENDED BY TILE MANUFACTURER. SEE ALSO "PATCHING AND PREPPING"
<br />NOTES / IA-G1.
<br />3. WHERE TILE FLOOR SLOPES TO DRAIN, PROVIDE WATERPROOFING OVER REINFORCED MORTAR
<br />BED, SLOPE 1/4" PER FOOT MAX TOWARD DRAIN.
<br />4. AT WET WALLS AND AREAS SUCH AS SHOWERS, PROVIDE WATERPROOF MEMBRANE COMPLIANT
<br />WITH ANSI A118.10 AND AS RECOMMENDED BY THE MANUFACTURER FOR THE APPLICATION
<br />INDICATED. INCLUDE REINFORCEMENT AND ACCESSORIES RECOMMENDED BY THE MANUFACTURER.
<br />5. PROVIDE EXPANSION JOINTS AND OTHER SEALANT-FILLED JOINTS, INCLUDING CONTROL JOINT,
<br />CONTRACTION, AND ISOLATION JOINTS. CONFIRM JOINT LOCATIONS WITH HENDY PRIOR TO
<br />INSTALLATION. DO NOT SAW-CUT JOINTS AFTER INSTALLING TILES.
<br />6. GROUT JOINTS AT TILES SHALL BE 1/8" MAX., U.N.O. GROUT SHALL BE SEALED WITH AQUAMIX
<br />"SEALER'S CHOICE" PER MANUFACTURER'S WRITTEN SPECIFICATIONS.
<br />7. PROVIDE CERAMIC TILE ADHESIVE CONTAINING VOC CONTENT OF NOT MORE THAN 50 G/L WHEN
<br />CALCULATED ACCORDING TO 40 CFR 59, SUBPART D (EPA 24).
<br />8. PROVIDE CERAMIC TILE SETTING GROUTING MATERIALS THAT ARE CHEMICAL RESISTANT, WATER-
<br />CLEANABLE, TILE-SETTING AND GROUTING EPOXY COMPLIANT WITH ANSI A118.3, WITH A VOC
<br />CONTENT OF NOT MORE THAN 65 G/L WHEN CALCULATED ACCORDING TO 40 CFR 59, SUBPART D
<br />(EPA 24).
<br />9. ON COMPLETION OF PLACEMENT AND GROUTING, CLEAN ALL CERAMIC TILE SURFACES SO THEY ARE
<br />FREE OF FOREIGN MATTER.
<br />1. FABRICATE CABINETS AND COUNTERTOPS WITH WOOD AND WOOD-BASED PRODUCTS PRODUCED
<br />FROM NOT LESS THAN 70% OF WOOD OBTAINED FROM FORESTS CERTIFIED BY AN FSC-ACCREDITED
<br />CERTIFICATION BODY TO COMPLY WITH FSC STD-01-001, FSC PRINCIPLES AND CRITERIA FOR FOREST
<br />STEWARDSHIP.
<br />2. REVIEW OF SHOP DRAWINGS SHALL BE GENERAL AND/OR FOR AESTHETIC INTERPRETATION, AND
<br />EXCEPT WHERE OTHERWISE INDICATED, SHALL NOT BE CONSTRUED AS PERMITTING ANY DEPARTURE
<br />FROM CONTRACT OR LEASE REQUIREMENT, RELIEVING THE CONTRACTOR OF RESPONSIBILITY FOR
<br />ANY ERROR IN DETAILS OR INSTRUCTIONS PREVIOUSLY FURNISHED BY HENDY. THE CONTRACTOR
<br />SHALL CORRECT ERRORS IN AND OMISSIONS FROM THE WORK WITHOUT ADDITIONAL COST TO THE
<br />TENANT WHETHER OR NOT WORK WAS INSTALLED AS PER REVIEWED SHOP DRAWINGS.
<br />3. WOOD VENEER CABINETS SHALL CONFORM TO AWI/WIC STANDARDS FOR PREMIUM GRADE MILLWORK.
<br />ALL PLASTIC LAMINATE CABINETS SHALL BE CUSTOM GRADE MILLWORK.
<br />4. PROVIDE WOOD STAIN PRODUCTS THAT COMPLY WITH THE FOLLOWING LIMITS FOR VOC CONTENT
<br />WHEN CALCULATED ACCORDING TO 40 CFR 59, SUBPART D (EPA METHOD 24):
<br />A. CLEAR WOOD FINISHES, VARNISHES: VOC CONTENT NOT MORE THAN 350 G/L.
<br />B. CLEAR WOOD FINISHES, LACQUERS: VOC CONTENT NOT MORE THAN 550 G/L.
<br />C. STAINS: VOC CONTENT NOT MORE THAN 250 G/L.
<br />5. PROVIDE MANUFACTURED WOOD CASEWORK, INCLUDING COUNTERTOPS, MADE WITH ADHESIVES AND
<br />COMPOSITE WOOD PRODUCTS THAT DO NOT CONTAIN UREA FORMALDEHYDE.
<br />6. PROVIDE PARTICLE BOARD COMPLIANT WITH ANSI A208.1, GRADE M-2, MADE WITH BINDER CONTAINING
<br />NO UREA-FORMALDEHYDE RESIN.
<br />7. PROVIDE MEDIUM-DENSITY FIBERBOARD: PROVIDE PRODUCTS COMPLIANT WITH ANSI A208.2, GRADE
<br />130, MADE WITH BINDER CONTAINING NO UREA FORMALDEHYDE.
<br />8. PLASTIC LAMINATE ADHESIVE AND SEALANT: PROVIDE SINGLE-COMPONENT, MILDEW RESISTANT,
<br />NEUTRAL CURING SILICONE/LATEX SEALANT RECOMMENDED BY PLASTIC PANELING MANUFACTURER
<br />AND COMPLIANT WITH REQUIREMENTS DIVISION 07 SECTION “JOINT SEALANTS”. VOC CONTENT SHALL
<br />NOT EXCEED 250 G/L WHEN CALCULATED ACCORDING TO 40 CFR 59, SUBPART D (EPA METHOD 24).
<br />9. PROVIDE VENEER-FACED PANEL PRODUCTS (HARDWOOD PLYWOOD) THAT ARE COMPLIANT WITH
<br />HPVA-HP-1, MADE WITH ADHESIVE CONTAINING NO UREA FORMALDEHYDE.
<br />10. MILLWORKER SHALL VERIFY SITE CONDITIONS FOR DELIVERY ACCESS PRIOR TO INSTALLATION.
<br />11. MILLWORKER SHALL VERIFY ALL DIMENSIONS AND CONDITIONS ON JOB SITE. ALL DISCREPANCIES
<br />BETWEEN HENDY'S DRAWINGS AND EXISTING CONDITIONS SHALL IMMEDIATELY BE BROUGHT TO THE
<br />ATTENTION OF HENDY FOR CLARIFICATION PRIOR TO THE COMMENCEMENT OF WORK.
<br />12. ALL BUILT-IN PLUMBING FIXTURES, ELECTRICAL AND APPLIANCES SHALL BE SUPPLIED AND INSTALLED
<br />BY GENERAL CONTRACTOR. CUT-OUTS SHALL BE PERFORMED BY MILLWORKER. GENERAL
<br />CONTRACTOR SHALL SUPPLY INFORMATION AND COORDINATE CLEARANCES AND CUTOUTS WITH
<br />MILLWORKER.
<br />13. ALL CABINETS SHALL BE CHECKED FOR PROPER MECHANICAL OPERATION.
<br />14. ALL CABINETRY SHALL BE ATTACHED TO WALLS OR STRUCTURE AS REQUIRED FOR STABLE
<br />INSTALLATION AND USE. MILLWORKER SHALL COORDINATE BACKING LOCATIONS WITH GENERAL
<br />CONTRACTOR AS REQUIRED TO SUPPORT WALL HUNG CABINETS.
<br />15. ALL PAINTED WOOD SURFACES SHALL BE PROPERLY SEALED, SANDED AND PRIMED TO RECEIVE FINAL
<br />FINISH COAT.
<br />16. ALL PLASTIC LAMINATE SHEETS SHALL BE PROPERLY BACKED TO PREVENT WARPAGE OF THE
<br />SUBSTRATE.
<br />17. ALL MILLWORK SHALL BE FABRICATED OF MINIMUM 3/4" STOCK MATERIAL.
<br />18. ALL MILLWORK SHALL BE SCRIBED TO WALLS, FLOORS AND/OR CEILING WHERE OCCURS.
<br />19. COUNTERTOP AND BASE CABINET SHALL ALIGN TO OUTSIDE END OF CABINET WHERE NO WALL
<br />OCCURS, U.N.O.. ALL EXPOSED FACES OF CABINETRY SHALL BE FINISHED.
<br />20. PROVIDE (3) HINGES ON CABINET DOORS EXCEEDING 14 INCHES IN WIDTH.
<br />21. SUBMIT MIN. (3) THREE EACH WOOD, PAINT AND/OR STAIN SAMPLES AND FINISHES FOR APPROVAL BY
<br />HENDY PRIOR TO FABRICATION ON 8" X 8" MINIMUM SAMPLES.
<br />22. ALL WOOD VENEER AND PLASTIC LAMINATE DOOR PANELS SHALL BE VERTICAL GRAINED, UNLESS
<br />NOTED OTHERWISE.
<br />23. DOOR AND DRAWER EDGES SHALL BE PLASTIC LAMINATE TO MATCH PLASTIC LAMINATE DOOR OR
<br />DRAWER FACE. SELF EDGES ON PLASTIC LAMINATE COUNTERTOPS SHALL MATCH COUNTERTOP.
<br />HHENDY.COM
<br />T (949) 851-3080
<br />4770 Campus Dr., Suite 100
<br />Newport Beach, CA 92660
<br />H ndy
<br />ISSUES AND REVISIONS
<br />JOB NUMBER
<br />SCALE
<br />PROJECT
<br />TEAM
<br />All specifications, drawings, concepts, designs, arrangements, intellectual and written material represented herein constitute
<br />unique and unpublished work of H. Hendy Associates and may not be copied, used by or disclosed to others without written
<br />consent of H. Hendy Associates.
<br /> 2023 H.HendyAssociatesc
<br />DATE
<br />04463.0000.24
<br />3080 S. HARBOR BLVD.
<br />SANTA ANA, CA 92704
<br />GENERAL NOTES
<br />IA-G2
<br />MCGUFF
<br />AB/CD
<br />POWER & COMMUNICATIONS
<br />PLUMBING
<br />CEILING
<br />FIRE SPRINKLERS
<br />LIGHT FIXTURES
<br />EXISTING ELEVATORS
<br />MECHANICAL DEVICES & DISTRIBUTION
<br />SEALANTS & ADHESIVES
<br />FINISHES
<br />FLOOR FINISHES & TRANSITIONS
<br />PAINT & WALL FINISHES
<br />TILE FINISHES
<br />MILLWORK
<br />NONE
<br />1.SIGNAGE IDENTIFYING ROOMS OR BUILDING AREAS SHALL BE LOCATED ON THE WALL NEXT TO THE
<br />LATCH SIDE OF THE DOOR MAXIMUM 60 INCHES A.F.F. AND MINIMUM 48”A.F.F.
<br />2.POST INTERNATIONAL SYMBOL OF ACCESSIBILITY ON OR ADJACENT TO ALL DISABLED ACCESSIBLE
<br />BUILDING ENTRANCES.
<br />SIGNAGE
<br />NO. DESCRIPTION DATE
<br />PLAN CHECK SUBMITTAL 3/17/25
|