SS-1 SERVICE SINK SEE PLANS 3 2 3/4 3/4 3 3 3 <br />TMV-1 <br />MASTER <br />THERMOSTATIC MIXING <br />VALVE <br />ROOF - - - - - - -LEONARD MODEL TM-2020B-3PS-LF. SEE DETAIL-5/ R1-P9.6 FOR DETAIL, SET AT 140 DEG-F OUTLET HW TEMP. PROVIDE WITH APPROVED SEISMIC BRACING. <br />INSTALL PER MANUFACTURER'S RECOMMENDATIONS. <br />WC-1 WATER CLOSET SEE PLANS 3 2 3/4 - 3 2.5 -AMERICAN STANDARD AFWALL 3351.511 (IAPMO #0677) WALL-MOUNTED ELONGATED WITH TOP-SPUD INLET, ADA COMPLIANT, 1.1 GPF SELECTRONIC FLUSH VALVE, <br />BATTERY POWERED SENSOR ACTIVATED, SEAT: OPEN FRONT LESS COVER, CARRIER: JR SMITH 210Y. <br />WC-2 WATER CLOSET, <br />PUBLIC, ADA SEE PLANS 4 2 1-1/2 - 4 5 -SAME AS WC-1 EXCEPT INSTALLED PER ADA REQUIREMENTS. <br />L-1 LAVATORY SEE PLANS 2 2 1/2 1/2 1 1 1 <br />AMERICAN STANDARD LUCERNE 0356.421 (IAPMO #0677), WALL HUNG WITH CONCEALED ARMS SUPPORT, FRONT OVERFLOW, ADA COMPLIANT, FAUCET: SLOAN <br />OPTIMA "SOLIS" MODEL EAF-275-ISM, SOLAR POWERED BATTERY BACK-UP SENSOR ACTIVATED ELECTRONIC FAUCET WITH INTEGRAL SPOUT TEMP. MIXER, 0.35 <br />GPM FLOW (IAPMO #4567). <br />L-2 LAVATORY, PUBLIC, <br />ADA SEE PLANS 2 2 1/2 1/2 1 1 1 SAME AS L-1 EXCEPT INSTALLED PER ADA REQUIREMENTS. <br />TP-1 TRAP PRIMER SEE PLANS - - - - - - -MIFAB MR-500 UPC LISTED, ACTIVATE AT 3 PSI PRESS. DROP, WITH FILTER SCREEN, BUILT-IN AIR GAP FITTING, PIPE DISTRIBUTION SYSTEM TO 6 DRAIN TRAPS. <br />PROVIDE WITH ACCESS PANEL TO SERVE ALL FD, FS, AND INDIRECT DRAINS. INSTALL PER MFR'S. RECOMMENDATIONS. <br />TP-2 TRAP PRIMER SEE PLANS - - - - - - -ZURN Z1020-CW-DU4 IAPMO #4864, FLUSH MOUNTED TO WALL WITH VANDAL-PROOF STAINLESS STEEL COVER. COORDINATE 120V POWER REQUIREMENTS WITH <br />ELECTRICAL CONTR. INSTALL PER MFR'S. RECOMMENDATIONS. PROVIDE WHA-1 AS REQUIRED. <br />WHA-A WATER HAMMER <br />ARRESTER SEE PLANS - - - - - - - PPP SC SERIES, INSTALL SIZES PER MANUFACTURER'S RECOMEMNDATIONS. PROVIDE WITH ACCESS PANEL. COORDINATE LOCATION WITH ARCHITECT. <br />FD-1 FLOOR DRAIN SEE PLANS 2 2 - - - - - MIFAB F1000-S UPC LISTED, WITH 6"X6" STAINLESS STEEL RECTANGULAR HEAVY-DUTY VANDAL-RESISTANT STRAINER AND TRAP PRIMER CONNECTION. <br />OD-1 ROOF DRAIN <br />OVERFLOW SEE PLANS - - - - - - - JR SMITH FIG. 1010, CAST IRON VANDAL PROOF LOW PROFILE DOME WITH WATER DAM 2" HIGHER THAN FINISH ROOF LEVEL, UNDERDECK CLAMP. <br />PD-1 PLANTER DRAINS SEE PLANS 3 - - - - - - JR SMITH 2671 WITH STAINLESS STEEL SCREEN, FLITER FABRIC, 12"x12"x12" GRAVEL AROUND. <br />TD-1 TRENCH DRAINS SEE PLANS 3 - - - - - - ACO KS100S KLASSIKDRAIN WITH ADA GRATE TYPE 478Q - DUCTILE IRON, HEEL PROOF, CLASS E. SEE PLANS FOR PIPE OUTLET SIZE. <br />AD-1 AREA DRAINS SEE PLANS - - - - - - - JR SMITH FIG. 1470, VANDAL PROOF GRATE, UNDERDECK CLAMP. COORDINATE COLOR FINISH WITH ARCHITECT. SEE FLOOR PLANS FOR OUTLET SIZE. <br />FS-1 FLOOR SINK SEE PLANS 2 2 - - - - - JR SMITH 3101 WITH OUTLET SAME AS PIPE SIZE, 1/2 GRATE, SEDIMENT BUCKET. <br />RR-1 ROOF RECEPTOR SEE PLANS 2 2 - - - - - JR SMITH FIG. 3980, WITH WATER DAM 2" HIGHER THAN FINISH ROOF. <br />ED-1 EMERGENCY DRAIN SEE PLANS 2 2 - - - - - MIFAB F1000 WITH HEAVY DUTY TRAFFIC RATED 7" DIA. STAINLESS STEEL STRAINER. <br />RD-1 ROOF DRAIN SEE PLANS - - - - - - - JR SMITH FIG. 1010, CAST IRON VANDAL PROOF LOW PROFILE DOME, UNDERDECK CLAMP. <br />OAD-1 OVERFLOW AREA <br />DRAINS SEE PLANS - - - - - - - SAME AS AD-1 EXCEPT PLACED AT HIGHER ELEVATION. <br />HB-1 HOSE BIB SEE PLANS - - 3/4 - - 2.5/1 - ARROWHEAD 353-LF-BFP-LK. PROVIDE ACCESSIBLE SOV UPSTREAM OF EACH HB. <br />ES-1 EYEWASH STATION SEE PLANS - - 3/4 - - - - HAWS MODEL 7460, 5 GPM <br />NOTES: <br />1. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT FIXTURE SPECS., LOCATIONS, ADDITIONAL INSTRUCTIONS, AND COLOR FINISHES. <br />2. INSTALL ALL ITEMS PER MANUFACTURER'S RECOMMENDATIONS. <br />3. PROVIDE ACCESSIBLE WHA-1 TO ALL QUICK CLOSING VALVES, INCLUDING DISHWASHERS, FLUSH VALVES, ETC. <br />4. COORDINATE ACC (ACCESS CODE COLLABORATION) REQUIREMENTS WITH ARCHITECT. <br />PLUMBING FIXTURES SCHEDULE (RES. BLDG.) <br />MARK <br />NO.DESCRIPTION LOCATION <br />MIN. ROUGH-IN CONN. (INCHES) <br />SS (DFU)CW <br />(WSFU) <br />HW <br />(WSFU)REMARKS <br />SS V CW HW <br />SP-1,2 SUMP PUMP, DUPLEX <br />SYSTEM 2 BASEMENT <br />2 HP (1 <br />HP EACH)- 3450 460 3 50 GPM EACH 61' --WEIL 2442-3450 <br />DUPLEX SUBMERSIBLE TYPE, WITH AUTOCOUPLING GUIDE RAIL CONFIGURATION 2613 REMOVAL, CONTROL PANEL, <br />ALTERNATOR, CONTROL TRANSFORMER, STARTER, INTRIST. SWITCH RELAY, AUDIO/VISUAL ALARM. COORD. ELECT. <br />RQMTS. WITH ELECT. CONTR. AND MONITORING WITH BMS CONTR. INSTALL PER MFR'S RECOMMENDATIONS. <br />NOTES: <br />1. INSTALL ALL UNITS PER MANUFACTURER'S RECOMMENDATIONS. <br />2. PROVIDE APPROVED SEISMIC BRACING, 6"H HOUSE-KEEPING PAD. <br />3. COORDINATE POWER REQUIREMENTS WITH ELECTRICAL CONTRACTOR PRIOR TO START OF WORK. <br />4. COORDINATE BMS MONITORING WITH BMS CONTRACTOR PRIOR TO START OF WORK. <br />5. PROVIDE LISTED MANUFACTURER OR EQUAL. <br />CP-L06 <br />ZONED INLINE <br />CIRCULATING PUMP, <br />FOR EWH-L06 <br />1 LEVEL-06 0.75 - - 115 1 17 GPM 48' - - BELL & GOSSETT ECOCIRCL-XL-65-130 <br />ALL BRONZE LEAD-FREE CONSTRUCTION, UL AND NSF LISTED, RATED AT 230°F, FOR HOT WATER RETURN, 100% BACK- <br />UP. PROVIDE SEISMIC BRACING, APPROVED AQUASTAT AND 24 HR/7 DAY TIME CLOCK, WEATHER-PROOF ENCLOSURE ON <br />ROOF. <br />WS-1 WATER SOFTENER 1 ROOF -SEE <br />REMARKS - - - <br />SALT: 1400 <br />LBS; PEAK <br />FLOW RATE <br />PER TANK: 94 <br />GPM <br />- - AREA: 192”W x 31”D CUSTOM H2O CH7224WS2QPS <br />WITH CH5030BT <br />8 AMPS, FOUR OUTLETS NECESSARY ON ONE 20A CIRCUIT, WITH 2" CONTROL VALVE AT EACH TANK, ALTERNATING <br />FLOW, CONTROLS: FULLY AUTOMATIC FACTORY WIRED FACTORY MOUNTED UNIT, HARDNESS MONITOR, 120 V, WITH <br />CONTROL PANEL AND ALARM SYSTEM, 2 RESIN TANKS, 1 BRINE TANK, PLUS 4-FT CLEAR IN FRONT, 1-FT CLEAR IN HT. <br />PROVIDE WITH APPROVED VACUUM RELIEF VALVE, SEISMIC RESTRAINT, AND 6"H HOUSEKEEPING PAD. COORD. ELECT. <br />RQMTS. WITH ELECT. CONTR. AND MONITORING WITH BMS CONTR. INSTALL PER MFR'S RECOMMENDATIONS. CONTACT <br />CHRIS MACKNIGHT OF CUSTOM H2O AT PHONE: 714-305-9015. <br />GI-1 GREASE INTERCEPTOR 1 BASEMENT - - - - - 1500 GAL - - 6' x 11' x 6'H JENSEN PRECAST JP1500G <br />PROVIDE UPC LISTED, TRAFFIC TYPE, CONCRETE PRECAST WITH BIOCRETE TYPE CONCRETE. COORDINATE LOCATION <br />AND DEPTH WITH STRUCTURAL ENGINEER. PROVIDE WITH TRAFFIC TYPE SAMPLING BOX. INSTALL PER <br />MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS. <br />SE-1,2 SEWAGE EJECTOR <br />DUPLEX SYSTEM 2 BASEMENT <br />15 HP (7.5 <br />HP EACH)- 1750 460 3 300 GPM EACH 43' - - HOMA AMS434-200/7,5T/C <br />FM <br />DUPLEX SUBMERSIBLE TYPE, EXPLOSION PROOF MOTOR, WITH AUTOCOUPLING GUIDE RAIL CONFIGURATION 2613 <br />REMOVAL, CONTROL PANEL, ALTERNATOR, CONTROL TRANSFORMER, STARTER, INTRIST. SWITCH RELAY, AUDIO/VISUAL <br />ALARM. COORD. ELECT. RQMTS. WITH ELECT. CONTR. AND MONITORING WITH BMS CONTR. INSTALL PER MFR'S <br />RECOMMENDATIONS. <br />CWM-1 COLD WATER METER 1 <br />SEE DETAILS <br />ON R1-P9.4 <br />FOR <br />LOCATIONS <br />- - - - - 1" - - - BADGER <br />E-SERIES G2® <br />ULTRASONIC INLINE <br />METERS <br />WITH BMS REMOTE MONITORING. COORDINATE WITH BMS CONTRACTOR FOR MONITORING PRIOR TO START OF WORK. <br />HWM-1 COLD WATER METER 1 <br />SEE DETAILS <br />ON R1-P9.4 <br />FOR <br />LOCATIONS <br />- - - - - 1" - - - BADGER <br />E-SERIES G2® <br />ULTRASONIC INLINE <br />METERS <br />WITH BMS REMOTE MONITORING. COORDINATE WITH BMS CONTRACTOR FOR MONITORING PRIOR TO START OF WORK. <br />FCS-1 <br />DOM. WATER <br />BACKFLOW <br />PREVENTER FLOOD <br />CONTROL <br />1 LEVEL P1 - - - - - - - - - ZURN FCISAST FLOOD <br />CONTROL SYSTEM <br />REFER TO CIVIL DRAWINGS FOR BACKFLOW PREVENTER LOCATION AND SPECIFICATIONS. REFER TO ELECTRICAL <br />DRAWINGS FOR POWER CONNECTION. CONNECT TO BUILDING AUTOMATION SYSTEM AS REQUIRED. <br />CP-1,2 <br />CIRCULATING PUMP, <br />DUPLEX FOR <br />GWH-1,2,3 <br />2 ROOF 0.75 - - 115 1 17 GPM 48' - - BELL & GOSSETT ECOCIRCL-XL-65-130 <br />ALL BRONZE LEAD-FREE CONSTRUCTION, UL AND NSF LISTED, RATED AT 230°F, FOR HOT WATER RETURN, 100% BACK- <br />UP. PROVIDE SEISMIC BRACING, APPROVED AQUASTAT AND 24 HR/7 DAY TIME CLOCK, WEATHER-PROOF ENCLOSURE ON <br />ROOF. <br />CP-L15 <br />ZONED INLINE <br />CIRCULATING PUMP, <br />FOR EWH-L15 <br />1 LEVEL-15 0.75 - - 115 1 17 GPM 48' - - BELL & GOSSETT ECOCIRCL-XL-65-130 <br />ALL BRONZE LEAD-FREE CONSTRUCTION, UL AND NSF LISTED, RATED AT 230°F, FOR HOT WATER RETURN, 100% BACK- <br />UP. PROVIDE SEISMIC BRACING, APPROVED AQUASTAT AND 24 HR/7 DAY TIME CLOCK, WEATHER-PROOF ENCLOSURE ON <br />ROOF. <br />EQUIPMENT SCHEDULE (RES. BLDG.) <br />MARK NO. DESCRIPTION QTY. LOCATION <br />MOTOR DATA <br />CAPACITY HEAD <br />(FT) <br />OP. WT. <br />(LBS)DIMENSIONS MAKE MODEL REMARKS <br />HP KW RPM VOLTS PHASE <br />© Gensler <br />Date Description <br />Project Name <br />Project Number <br />Description <br />Scale <br />Seal / Signature <br />2015 <br />NOT FOR <br />CONSTRUCTION <br />Tel 949.863.9434 <br />Fax 949-553-1676 <br />4675 MacArthur Court <br />Suite 100 <br />Newport Beach, CA <br />92600 <br />USA <br />Job No.: <br />Contact: <br />www.glumac.com <br />18200 Von Karman Ave., Suite 100 <br />Irvine, CA 92612 <br />T. 949.833.8190 <br />12" = 1'-0" <br />6/12/2024 7:39:07 PM <br />BIM 360://007.3757.000 - Caribou Industries - 3rd & Broadway/3RD-B_MEP_WEST_R20.rvt <br />R1-P0.2 <br />PLUMBING SCHEDULES <br />21US00608 <br />3rd & Broadway West <br />1103 North Broadway <br />Santa Ana, CA 92701 <br />21US00608 <br />TG <br />1 9/21/2021 REISSUE FOR PLAN CHECK <br />2 01/18/2022 REISSUE FOR PLAN CHECK <br />4 06/17/2024 REVISION TO PERMIT <br />4 <br />EOR: SEAN AGUON <br />LIC#: M41274 <br />10/11/2024