Laserfiche WebLink
SCALE: NONESCALE: NONESCALE: NONE <br />SCALE: NONE <br />SCALE: NONE <br />SCALE: NONE <br />SCALE: NONE <br />1 PIPE PENETRATION THRU FIRE RATED CONC. WALL & FLOOR3PIPE PENETRATION THROUGH FIRE RATED CONC. WALL & FLOOR5PIPE PENETRATION NOTES <br />2 PIPE PENETRATION THRU FIRE RATED GYPSUM WALL <br />6 NO-HUB PIPE SWAY BRACING FOR HORIZONTAL PIPING <br />4 NO-HUB PIPE BRACING FOR MULTIPLE FITTINGS <br />7 TYPICAL SUB-WATER METER PIPING DETAIL <br />M <br />System No. C-AJ-1421 <br />SECTION A-A <br />1. FLOOR OR WALL ASSEMBLY - MIN 4-1/2 IN. (114 MM) THICK REINFORCED LIGHTWEIGHT OR NORMAL WEIGHT (100-150 PCF OR 1600-2400 KG/M3) CONCRETE. WALL <br />MAY ALSO BE CONSTRUCTED OF ANY UL CLASSIFIED CONCRETE BLOCKS*. MAX DIAM OF OPENING IS 6 IN. (152 MM). <br />SEE CONCRETE BLOCKS (CAZT) CATEGORY IN THE FIRE RESISTANCE DIRECTORY FOR NAMES OF MANUFACTURERS. <br />2. METALLIC SLEEVE - (OPTIONAL) NOM 6 IN. (152 MM) DIAM (OR SMALLER) SCHEDULE 40 (OR HEAVIER) STEEL SLEEVE CAST OR GROUTED INTO FLOOR OR WALL <br />ASSEMBLY, FLUSH WITH FLOOR OR WALL <br />SURFACES.3. THROUGH-PENETRANT - ONE METALLIC PIPE OR CONDUIT TO BE INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. THE <br />ANNULAR SPACE BETWEEN PIPE, TUBE OR CONDUIT AND PERIPHERY OF OPENING SHALL BE MIN 0 IN. (0 MM) (POINT CONTACT) TO MAX 5-3/8 IN. (137 MM). PIPE OR <br />CONDUIT TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF FLOOR OR WALL ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF METALLIC PIPES OR CONDUITS MAY <br />BE USED: <br />A. STEEL PIPE - NOM 4 IN. (102 MM) DIAM (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL PIPE. <br />B. IRON PIPE - NOM 4 IN. (102 MM) DIAM (OR SMALLER) CAST OR DUCTILE IRON PIPE. <br />C. COPPER PIPE - NOM 4 IN. (102 MM) DIAM (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE. <br />D. COPPER TUBING - NOM 4 IN. (102 MM) DIAM (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBING. <br />E. CONDUIT - NOM 4 IN. (102 MM) DIAM (OR SMALLER) STEEL CONDUIT. <br />F. CONDUIT - NOM 4 IN. (102 MM) DIAM (OR SMALLER) STEEL ELECTRICAL METALLIC TUBING (EMT). <br />4. FIRESTOP SYSTEM - THE FIRESTOP SYSTEM SHALL CONSIST OF THE FOLLOWING: <br />A. PACKING MATERIAL - MIN 4 IN. (102 MM) THICKNESS OF MIN 4 PCF (64 KG/M3) MINERAL WOOL BATT INSULATION FIRMLY PACKED INTO OPENING AS A <br />PERMANENT FORM. PACKING MATERIAL TO BE RECESSED FROM TOP SURFACE OF FLOOR OR FROM BOTH SURFACES OF WALL AS REQUIRED TO <br />ACCOMMODATE THE REQUIRED THICKNESS OF FILL <br />MATERIAL.B. FILL, VOID OR CAVITY MATERIAL* - SEALANT - MIN 1/4 IN. (6 MM) THICKNESS OF FILL MATERIAL APPLIED WITHIN THE ANNULUS, FLUSH WITH TOP SURFACE OF <br />FLOOR OR WITH BOTH SURFACES OF WALL. FOR 3 HR RATED ASSEMBLIES, A MIN 1/4 IN. (6 MM) DIAM BEAD OF FILL MATERIAL SHALL BE APPLIED AT THE <br />CONCRETE/PIPE INTERFACE AT THE POINT CONTACT LOCATION ON THE TOP SURFACE OF FLOOR AND ON BOTH SURFACES OF WALL. <br />HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC - FS-ONE SEALANT OR CP604 SELF-LEVELING FIRESTOP SEALANT. CP604 SHALL BE USED IN FLOOR <br />APPLICATIONS ONLY. WHEN CP604 IS USED, F RATING IS 2 <br />HR.*BEARING THE UL CLASSIFICATION MARK <br />A <br />REPRODUCED BY HILTI, INC. <br />COURTESY OF UNDERWRITERS <br />LABORATORIES, INC. <br />APRIL 26, 2004 <br />F Rating - 2 and 3 Hr (See Item 4B) <br />T Rating = 0 Hr <br />A <br />4B <br />2 <br />3 <br />4B <br />1 <br />4A <br />System No. C-AJ-1226 <br />SECTION A-A <br />A <br />REPRODUCED BY HILTI, INC. COURTESY <br />OF UNDERWRITERS LABORATORIES, <br />INC. <br />JUNE 27, 2007 <br />F Rating - 3 Hr <br />T Rating - 0 Hr <br />L Rating At Ambient - Less Than 1 CFM/Sq Ft <br />L Rating At 400 F - 4 CFM/Sq Ft <br />Hilti Firestop Systems <br />1. FLOOR OR WALL ASSEMBLY —MIN 4-1/2 IN. THICK REINFORCED LIGHTWEIGHT OR NORMAL WEIGHT (100-150 PCF) CONCRETE. WALL MAY ALSO BE CONSTRUCTED OF ANY UL <br />CLASSIFIED CONCRETE BLOCKS*. MAX DIAM OF OPENING IS 32 <br />IN.2. METALLIC SLEEVE —(OPTIONAL) NOM 32 IN. DIAM (OR SMALLER) SCHEDULE 40 (OR HEAVIER) STEEL SLEEVE CAST OR GROUTED INTO FLOOR OR WALL ASSEMBLY, FLUSH WITH <br />FLOOR OR WALL SURFACES OR EXTENDING A MAX OF 3 IN. ABOVE FLOOR OR BEYOND BOTH SURFACES OF WALL. <br />2A. SHEET METAL SLEEVE —(OPTIONAL) MAX 6 IN. DIAM, MIN 26 GA GALV STEEL PROVIDED WITH A 26 GA GALV STEEL SQUARE FLANGE SPOT WELDED TO THE SLEEVE AT <br />APPROX MID-HEIGHT, OR FLUSH WITH BOTTOM OF SLEEVE IN FLOORS, AND SIZED TO BE A MIN OF 2 IN. LARGER THAN THE SLEEVE DIAM. THE SLEEVE IS TO BE CAST IN PLACE <br />AND MAY EXTEND A MAX OF 4 IN. BELOW THE BOTTOM OF THE DECK AND A MAX OF 1 IN. ABOVE THE TOP SURFACE OF THE CONCRETE <br />FLOOR.2B. SHEET METAL SLEEVE —(OPTIONAL) - MAX 12 IN. DIAM, MIN 24 GA GALV STEEL PROVIDED WITH A 24 GA GALV STEEL SQUARE FLANGE SPOT WELDED TO THE SLEEVE AT <br />APPROX MID-HEIGHT, OR FLUSH WITH BOTTOM OF SLEEVE IN FLOORS, AND SIZED TO BE A MIN OF 2 IN. LARGER THAN THE SLEEVE DIAM. THE SLEEVE IS TO BE CAST IN PLACE <br />AND MAY EXTEND A MAX OF 4 IN. BELOW THE BOTTOM OF THE DECK AND A MAX OF 1 IN. ABOVE THE TOP SURFACE OF THE CONCRETE <br />FLOOR.3. THROUGH-PENETRANT —ONE METALLIC PIPE, TUBE OR CONDUIT TO BE INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. THE <br />ANNULAR SPACE BETWEEN PENETRANT AND PERIPHERY OF OPENING SHALL BE MIN 0 IN. (POINT CONTACT) TO MAX 1-7/8 IN. PENETRANT MAY BE INSTALLED WITH CONTINUOUS <br />POINT CONTACT. PENETRANT TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF FLOOR OR WALL ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF METALLIC PENETRANTS MAY <br />BE USED: <br />A. STEEL PIPE —NOM 30 IN. DIAM (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL PIPE. <br />B. IRON PIPE —NOM 30 IN. DIAM (OR SMALLER) CAST OR DUCTILE IRON PIPE. <br />C. COPPER PIPE —NOM 6 IN. DIAM (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE. <br />D. COPPER TUBING —NOM 6 IN. DIAM (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBING. <br />E. CONDUIT —NOM 6 IN. DIAM (OR SMALLER) STEEL CONDUIT. <br />F. CONDUIT —NOM 4 IN. DIAM (OR SMALLER) STEEL ELECTRICAL METALLIC TUBING (EMT). <br />4. FIRESTOP SYSTEM —THE FIRESTOP SYSTEM SHALL CONSIST OF THE FOLLOWING: <br />A. PACKING MATERIAL —MIN 4 IN. THICKNESS OF MIN 4 PCF MINERAL WOOL BATT INSULATION FIRMLY PACKED INTO OPENING AS A PERMANENT FORM. PACKING MATERIAL <br />TO BE RECESSED FROM TOP SURFACE OF FLOOR OR SLEEVE OR FROM BOTH SURFACES OF WALL OR SLEEVE AS REQUIRED TO ACCOMMODATE THE REQUIRED THICKNESS <br />OF FILL <br />MATERIAL.B. FILL, VOID OR CAVITY MATERIAL*—SEALANT —MIN 1/4 IN. THICKNESS OF FILL MATERIAL APPLIED WITHIN THE ANNULUS, FLUSH WITH TOP SURFACE OF FLOOR OR <br />SLEEVE OR WITH BOTH SURFACES OF WALL OR SLEEVE. AT THE POINT OR CONTINUOUS CONTACT LOCATIONS BETWEEN PENETRANT AND CONCRETE OR SLEEVE, A MIN 1/4 <br />IN. DIAM BEAD OF FILL MATERIAL SHALL BE APPLIED AT THE CONCRETE OR SLEEVE/ PIPE PENETRANT INTERFACE ON THE TOP SURFACE OF FLOOR AND ON BOTH <br />SURFACES OF WALL. <br />HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC —FS-ONE SEALANT <br />*BEARING THE UL CLASSIFICATION MARK <br />A <br />2 <br />3 <br />4B <br />3 <br />14B <br />4A <br />Hilti Firestop Systems <br />C <br />CLASSI FIED <br />Classified by <br />Underwriters Laboratories, <br />Inc. <br />to UL 1479 and <br />CAN/ULC-S115 <br />US <br />C <br />CLASSI F IED <br />Classified by <br />Underwriters Laboratories, <br />Inc. <br />to UL 1479 and <br />CAN/ULC-S115 <br />US <br />Hilti Firestop Systems <br />System No. W-L-1206 <br />SECTION A-A <br />1. WALL ASSEMBLY —THE FIRE-RATED GYPSUM BOARD/STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER DESCRIBED IN THE INDIVIDUAL U400 OR V400 <br />SERIES WALL AND PARTITION DESIGN IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES: <br />A. STUDS —"C-T" SHAPED STUDS 1-5/8 IN. WIDE BY 2-1/2 IN. DEEP, FABRICATED FROM 25 MSG GALV STEEL, SPACED MAX 24 IN. OC. <br />B. GYPSUM BOARD*—ONE LAYER OF NOM 1 IN. THICK, 24 IN. WIDE GYPSUM LINER AND ONE OR TWO LAYERS OF NOM 5/8 IN. THICK, 4 FT. WIDE GYPSUM BOARD WITH SQUARE OR TAPERED <br />EDGES. THE GYPSUM BOARD TYPES, NUMBER OF LAYERS, FASTENER TYPE AND SHEET ORIENTATION SHALL BE AS SPECIFIED IN THE INDIVIDUAL WALL AND PARTITION DESIGN. MAX <br />DIAMOF OPENING IS 10-1/2 IN. <br />1A. WALL ASSEMBLY —AS AN ALTERNATE TO THE ABOVE WALL ASSEMBLY, THE 1 OR 2 HR FIRE RATED GYPSUM BOARD/STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND <br />IN THE MANNER SPECIFIED IN THE INDIVIDUAL U300, U400 OR V400 SERIES WALL AND PARTITION DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING <br />CONSTRUCTION FEATURES: <br />A. STUDS —WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. STEEL STUDS TO BE MIN 2-1/2 IN. WIDE AND SPACED MAX 24 IN. OC. WOOD STUDS TO <br />CONSIST OF NOM 2 BY 4 IN. LUMBER SPACED 16 IN. OC. <br />B. GYPSUM BOARD*—THICKNESS, TYPE, NUMBER OF LAYERS AND FASTENERS AS REQUIRED IN THE INDIVIDUAL WALL AND PARTITION DESIGN. MAX DIAM OF OPENING IS 10-1/2 IN. <br />THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS EQUAL TO THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED. <br />2. METALLIC SLEEVE —MAX 10-1/2 IN. DIAM CYLINDRICAL SLEEVE FABRICATED FROM MIN 0.016 IN. THICK (28 GAUGE) GALV SHEET STEEL AND HAVING A MIN 1 IN. LAP ALONG THE LONGITUDINAL <br />SEAM. LENGTH OF STEEL SLEEVE TO BE EQUAL TO THICKNESS OF WALL. SLEEVE INSTALLED BY COILING THE SHEET STEEL TO A DIAM SMALLER THAN THE THROUGH OPENING, INSERTING THE <br />COIL THROUGH THE OPENING AND RELEASING THE COIL TO LET IT UNCOIL AGAINST THE CIRCULAR CUTOUTS IN THE GYPSUM BOARD LAYERS. SLEEVE MAY ALSO BE FORMED OF NO. 8 STEEL <br />WIRE MESH HAVING A MIN 1 IN. LAP ALONG THE LONGITUDINAL <br />SEAM.3. THROUGH-PENETRANTS —ONE METALLIC PIPE, CONDUIT OR TUBING TO BE INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. AN ANNULAR SPACE OF <br />MIN 0 IN. (POINT CONTACT) TO MAX 1-7/8 IN. IS REQUIRED WITHIN FIRESTOP SYSTEM. PIPE, CONDUIT OR TUBING TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. THE <br />FOLLOWING TYPES AND SIZES OF METALLIC PIPES, CONDUITS OR TUBING MAY BE USED: <br />A. STEEL PIPE —NOM 8 IN. DIAM (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL PIPE. <br />B. IRON PIPE —NOM 8 IN. DIAM (OR SMALLER) CAST OR DUCTILE IRON PIPE. <br />C. CONDUIT —NOM 4 IN. DIAM (OR SMALLER) STEEL ELECTRICAL METALLIC TUBING OR 4 IN. DIAM STEEL CONDUIT. <br />D. COPPER TUBING —NOM 4 IN. DIAM (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBING. <br />E. COPPER PIPE —NOM 4 IN. DIAM (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE. <br />F. FLEXIBLE STEEL CONDUIT+—NOM 2 IN. DIAM (OR SMALLER) FLEXIBLE STEEL CONDUIT. <br />SEE FLEXIBLE METAL CONDUIT (DXUZ) CATEGORY IN THE ELECTRICAL CONSTRUCTION EQUIPMENT DIRECTORY FOR NAMES OF MANUFACTURERS. <br />4. FIRESTOP SYSTEM —THE FIRESTOP SYSTEM SHALL CONSIST OF THE FOLLOWING: <br />A. PACKING MATERIAL —MIN 1-5/8 OR 2-1/4 IN. THICKNESS OF MIN 4 PCF MINERAL WOOL BATT INSULATION FIRMLY PACKED INTO SLEEVE ON ONE SIDE OF THE WALL AS PERMANENT FORM <br />FOR 1 AND 2 HR WALLS, RESPECTIVELY. PACKING MATERIAL TO BE RECESSED FROM THE ROOM SIDE OF WALL AS REQUIRED TO ACCOMMODATE THE REQUIRED THICKNESS OF FILL <br />MATERIAL. IN ALTERNATE WALL ASSEMBLY, PACKING MATERIAL TO BE FLUSH WITH EITHER SIDE OF THE WALL AND RECESSED FROM THE OTHER SIDE OF THE WALL TO ACCOMMODATE <br />THE REQUIRED THICKNESS OF FILL <br />MATERIAL.B. FILL, VOID OR CAVITY MATERIAL —SEALANT*—MIN 1-1/2 IN. THICKNESS APPLIED WITHIN SLEEVE, FLUSH WITH THE SURFACE OF WALL. AT THE POINT CONTACT LOCATION BETWEEN <br />PIPE AND WALL, A MIN 1/2 IN. DIAM BEAD OF FILL MATERIAL SHALL BE APPLIED AT THE PIPE/WALL INTERFACE. <br />HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC —FS-ONE SEALANT <br />*BEARING THE UL CLASSIFICATION MARK <br />+BEARING THE UL LISTING MARK <br />A <br />REPRODUCED BY HILTI, INC. COURTESY <br />OF UNDERWRITERS LABORATORIES, <br />INC. <br />AUGUST 31, 2005 <br />F Ratings — 1 and 2 Hr (See Items 1 and 4) <br />T Rating — 0 Hr <br />A <br />3 2 <br />4B <br />4A <br />1 4B <br />3 <br />2 <br />4B <br />C <br />CLASSI F IED <br />Classified by <br />Underwriters Laboratories, <br />Inc. <br />to UL 1479 and <br />CAN/ULC-S115 <br />US <br />PIPE PENETRATION NOTES : <br />1. PIPE PENETRATION DETAILS SHOWN ARE TYPICAL DETAILS. IF FIELD CONDITIONS DO NOT MATCH REQUIREMENTS OF TYPICAL DETAILS, APPROVED ALTERNATE DETAILS SHALL BE <br />UTILIZED. FIELD CONDITIONS AND DIMENSIONS NEED TO BE VERIFIED FOR COMPLIANCE WITH THE DETAILS, INCLUDING BUT NOT LIMITED TO THE FOLLOWING: <br />* MINIMUM AND MAXIMUM WIDTH OF JOINTS <br />* TYPE AND THICKNESS OF FIRE-RATED CONSTRUCTION. THE MINIMUM ASSEMBLY RATING OF THE FIRESTOP ASSEMBLY SHALL MEET OR EXCEED THE HIGHEST RATING OF THE <br />ADJACENTCONSTRUCTION. <br />2. IF ALTERNATE PIPE PENETRATION DETAILS MATCHING THE FIELD CONDITIONS ARE NOT AVAILABLE, MANUFACTURER'S ENGINEERING JUDGMENT DRAWINGS ARE ACCEPTABLE. <br />DRAWINGSSHALL FOLLOW THE INTERNATIONAL FIRESTOP COUNCIL (IFC) GUIDELINES FOR EVALUATING FIRESTOP SYSTEMS ENGINEERING JUDGMENTS. <br />3. REFERENCES: <br />* 2012 UNDERWRITER'S LABORATORIES FIRE RESISTANCE DIRECTORY, VOLUME 2 <br />* NFPA 101 LIFE SAFETY CODE <br />* ALL GOVERNING LOCAL AND REGIONAL BUILDING CODES <br />4. FIRESTOP SYSTEM INSTALLATION MUST MEET REQUIREMENTS OF ASTM E-814 (UL 1479) TESTED ASSEMBLIES THAT PROVIDE A FIRE RATING EQUAL TO THAT OF CONSTRUCTION BEING <br />PENETRATED. <br />5. ALL RATED THROUGH-PENETRATIONS SHALL BE PROMINENTLY LABELED WITH THE FOLLOWING INFORMATION: <br />* ATTENTION: FIRE RATED ASSEMBLY <br />* UL SYSTEM # <br />* PRODUCT(S) USED <br />* HOURLY RATING (F-RATING) <br />* INSTALLATION DATE <br />SEISMIC BRACES MAY BE INSTALLED AT EITHER HANGER. BRACES AT BOTH HANGERS ARE NOT REQUIRED. <br />WHERE MULTIPLE SHIELD AND CLAMP JOINTS OCCUR IN CLOSELY SPACED ASSEMBLY (I.E. FITTING-FITTING-FITTING, <br />ETC.) A 16 GAUGE HALF SLEEVE MAY BE INSTALLED UNDER THE ASSEMBLY WITH A PIPE HANGER AT EACH <br />END OF THE SLEEVE. <br />FOR ALL PIPING SYSTEM SEISMIC BRACING AND SEISMIC RESTRAINTS SHALL BE PER SMACNA LATEST EDITION. <br />NOTES: <br />1. <br />2. <br />3. <br />GREATER <br />BRACE ON OFFSETS IN EXCESS OF 10 FEET. SUBMIT DETAILS IF VARIATION <br />LOCATE BRACE EVERY 30 FT. ON STRAIGHT RUNS WITH AT LEAST ONE <br />SWAY BRACING SHALL BE PROVIDED TO PREVENT HORIZONTAL MOVEMENT. <br />WHEN HUBLESS PIPING IS SUSPENDED IN EXCESS OF 6" BELOW STRUCTURE, <br />THAN 6" <br />16" GAUGE CONTINUOUS <br />GALVANIZED SHEET METAL <br />MAXIMUM HANGER SPACING 10'-0" <br />SLEEVE <br />TYP. RIGID TRANSVERSE <br />BRACE (IF REQUIRED) <br />IS REQUIRED. <br />45° <br />BRACE (ALTERNATE <br />LOCATION IF REQUIRED) <br />TYP. RIGID TRANSVERSE <br />SWAY BRACE <br />45° <br />CLEVIS OR "J" HANGER <br />TYP. RIGID LONGITUDINAL <br />BRACE <br />HUBLESS CAST IRON <br />SOIL PIPE FITTING <br />CW SUPPLY TO BUILDING <br />FULL-SIZED BY-PASS LINE <br />WITH SOV(N.C.) <br />DCW SUPPLY FROM BUILDING <br />PROVIDE CONNECTION TO BMS <br />SUB-WATER METER IN ACCESSIBLE AREAUNION (TYP) <br />© Gensler <br />Date Description <br />Project Name <br />Project Number <br />Description <br />Scale <br />Seal / Signature <br />2015 <br />NOT FOR <br />CONSTRUCTION <br />Tel 949.863.9434 <br />Fax 949-553-1676 <br />4675 MacArthur Court <br />Suite 100 <br />Newport Beach, CA <br />92600 <br />USA <br />Job No.: <br />Contact: <br />www.glumac.com <br />18200 Von Karman Ave., Suite 100 <br />Irvine, CA 92612 <br />T. 949.833.8190 <br />6/12/2024 7:40:14 PM <br />BIM 360://007.3757.000 - Caribou Industries - 3rd & Broadway/3RD-B_MEP_WEST_R20.rvt <br />R1-P9.3 <br />PLUMBING DETAILS <br />21US00608 <br />3rd & Broadway West <br />1103 North Broadway <br />Santa Ana, CA 92701 <br />21US00608 <br />TG <br />1 9/21/2021 REISSUE FOR PLAN CHECK <br />2 01/18/2022 REISSUE FOR PLAN CHECK <br />4 06/17/2024 REVISION TO PERMIT <br />EOR: SEAN AGUON <br />LIC#: M41274 <br />10/11/2024