My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2800 N Main St Unit# 1100 - Plan
PBA
>
Building
>
ProjectDox
>
M
>
Main St
>
2800 N Main St Unit# 1100 Bldg# 2810
>
2800 N Main St Unit# 1100 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2026 5:03:22 AM
Creation date
2/13/2026 5:00:40 AM
Metadata
Fields
Template:
Plan
Permit Number
20185547
40140186
101124821
Full Address
2800 N Main St Unit# 1100 Bldg# 2810
Street Number
2800
Street Direction
N
Street Name
Main
Street Suffix
St
Building Number
2810
Unit Number
1100
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
647
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Round 1 Bowling and Amusement 12/09/2024 Paradigm Design <br />Main Place Mall Expansion Grand Rapids, MI <br />Santa Ana, California <br />Project #2309147GR <br />HVAC INSULATION 23 0700 - 6 <br />O.Phenolic: <br />1.Products: Subject to compliance with requirements, provide one of the following: <br />a.Kingspan Corp.; Koolphen K. <br />b.Other manufacturers by voluntary alternates. <br />2.Preformed pipe insulation of rigid, expanded, closed-cell structure. Comply with <br />ASTM C 1126, Type III, Grade 1. <br />3.Block insulation of rigid, expanded, closed-cell structure. Comply with ASTM C 1126, <br />Type II, Grade 1. <br />4.Factory fabricate shapes according to ASTM C 450 and ASTM C 585. <br />5.Factory-Applied Jacket: Requirements are specified in "Factory-Applied Jackets" <br />Article. <br />a.Preformed Pipe Insulation: ASJ. <br />b.Board for Duct and Plenum Applications: ASJ. <br />c.Board for Equipment Applications: ASJ. <br />P.Polyisocyanurate: Unfaced, preformed, rigid cellular polyisocyanurate material intended for <br />use as thermal insulation. <br />1.Products: Subject to compliance with requirements, provide one of the following: <br />a.Dow Chemical Company (The); Trymer. <br />b.Other manufacturers by voluntary alternates. <br />2.Comply with ASTM C 591, Type I or Type IV, except thermal conductivity (k-value) <br />shall not exceed 0.19 Btu x in./h x sq. ft. x deg F at 75 deg F after 180 days of aging. <br />3.Flame-spread index shall be 25 or less and smoke-developed index shall be 50 or less for <br />thickness up to 1-1/2 inches as tested by ASTM E 84. <br />4.Fabricate shapes according to ASTM C 450 and ASTM C 585. <br />5.Factory-Applied Jacket: Requirements are specified in "Factory-Applied Jackets" <br />Article. <br />Q.Polyolefin: Unicellular, polyethylene thermal plastic insulation. Comply with ASTM C 534 or <br />ASTM C 1427, Type I, Grade 1 for tubular materials and Type II, Grade 1 for sheet materials. <br />1.Products: Subject to compliance with requirements, provide one of the following: <br />a.Armacell LLC; Tubolit. <br />b.Other manufacturers by voluntary alternates. <br />R.Polystyrene: Rigid, extruded cellular polystyrene intended for use as thermal insulation. <br />Comply with ASTM C 578, Type IV or Type XIII, except thermal conductivity (k-value) shall <br />not exceed 0.26 Btu x in./h x sq. ft. x deg F after 180 days of aging. Fabricate shapes according <br />to ASTM C 450 and ASTM C 585. <br />1.Products: Subject to compliance with requirements, provide one of the following:
The URL can be used to link to this page
Your browser does not support the video tag.