CITY OF�SANTA ANA <br />Plannin ar�iGYYYiWYWncY <br />ELECTRICAL SYMBOLS <br />THIS IS A MASTER LEGEND AND NOT ALL SYMBOLS OR ABBREVIATIONS ARE USED <br />STANDARD MOUNTING HEIGHTS <br />AUDIBLE APPLIANCES (CENTERLINE) <br />84" <br />ALARMS <br />48" <br />ANNUNCIATOR PANELS (DISPLAY) <br />60" <br />CONTROLS (TOP OF DEVICE) <br />48" <br />EXIT SIGNS (WALL MOUNTED) <br />80" <br />FIRE ALARM ANNUNCIATOR PANEL (DISPLAY) <br />60" <br />FIRE ALARM BELL (EXTERIOR) (CENTERLINE) <br />120" <br />FIRE ALARM CONTROL PANEL/UNIT (DISPLAY) <br />60" <br />INTERCOM (AFEA ONLY) <br />36" <br />INTERCOMS (TOP OF DEVICE) <br />48" <br />PULL STATIONS (TOP OF DEVICE) <br />48" <br />PHOTOCELLS <br />144" <br />RECEPTACLES <br />16" <br />RECEPTACLES (EXTERIOR) <br />24" <br />RECEPTACLES(GARAGES) <br />24" <br />RECEPTACLES (POOLS) <br />27" <br />RECEPTACLES (ABOVE COUNTER) +6" ABOVE BACKSPLASH/COUNTER, 40" MAX <br />RECEPTACLES IN EQUIPMENT ROOMS <br />44" <br />REMOTE INDICATING LIGHT (EQUIPMENT ROOMS) <br />48" <br />REMOTE INDICATING LIGHT (FINISHED AREAS) <br />CEILING <br />SAFETY SWITCHES (TOP OF DEVICE) <br />48" <br />STARTERS (TOP OF DEVICE) <br />48" <br />SWITCHES (TOP OF DEVICE) <br />44" <br />TELEPHONE, DATA OUTLETS <br />SAME AS ADJACENT DEVICE, LINO <br />TELEPHONE TERMINAL BOARD (BOTTOM) <br />6" <br />TELEVISION OUTLETS <br />REFER TO ARCH DRAWINGS <br />VISIBLE APPLIANCES (CENTERLINE) <br />84" <br />INSTALL OUTLET BOXES AT THE MOUNTING HEIGHTS SHOWN ABOVE LINO IN THE <br />CONSTRUCTION DOCUMENTS. MOUNTING HEIGHTS LISTED ABOVE, OR ELSEWHERE IN THE <br />CONSTRUCTION DOCUMENTS, ARE AFF OR AFG TO BOTTOM OF OUTLET BOX, UNO. ALL <br />DEVICES SHALL BE INSTALLED IN COMPLIANCE WITH CURRENT ADA AND LOCAL <br />REQUIREMENTS. <br />AF <br />AMPERE FUSE SIZE <br />AFC <br />ABOVE FINISHED CEILING <br />AFF <br />ABOVE FINISHED FLOOR <br />AFG <br />ABOVE FINISHED GRADE <br />AHJ <br />AUTHORITY HAVING <br />JURISDICTION <br />AHU <br />AIR HANDLING UNIT <br />AIC <br />AMPERE INTERRUPTING <br />CAPACITY <br />AS <br />AMPERE SWITCH SIZE <br />AT <br />AMPERE TRIP SETTING <br />ATS <br />AUTOMATIC TRANSFER SWITCH <br />AV <br />AUDIO VISUAL <br />BAS <br />BUILDING AUTOMATION <br />SYSTEM <br />BKR <br />BREAKER <br />C <br />CONDUIT <br />CAT <br />CATEGORY <br />CATV <br />CABLE TELEVISION SYSTEM <br />CCTV <br />CLOSED CIRCUIT TELEVISION <br />CD <br />CANDELA <br />CKT <br />CIRCUIT <br />CODE <br />APPLICABLE CODE ADOPTED BY <br />JURISDICTION <br />CT <br />CURRENT TRANSFORMER <br />CTR <br />CENTER <br />CVD <br />CUMULATIVE VOLTAGE DROP <br />D/DEMO <br />DEMOLITION <br />DPDT <br />DOUBLE -POLE, <br />DOUBLE -THROW <br />DPST <br />DOUBLE -POLE, <br />SINGLE -THROW <br />E/ETR/EX <br />EXISTING TO REMAIN <br />EC <br />ELECTRICAL CONTRACTOR <br />EF <br />EXHAUST FAN <br />EM <br />EMERGENCY <br />EMS <br />ENERGY MANAGEMENT <br />SYSTEM <br />ELV <br />ELECTRONIC LOW -VOLTAGE <br />EWC <br />ELECTRIC WATER COOLER <br />FAAP <br />FIRE ALARM ANNUNCIATOR <br />PANEL <br />FACP <br />FIRE ALARM CONTROL PANEL <br />FCA <br />FAULT CURRENT AMPS AVAILABLE <br />FCU <br />FAN COIL UNIT <br />FF <br />FINISHED FLOOR <br />FLA <br />FULL LOAD AMPS <br />FLR <br />FLOOR <br />GC <br />GENERAL CONTRACTOR <br />GEC <br />GROUNDING ELECTRODE <br />CONDUCTOR <br />GES <br />GROUNDING ELECTRODE SYSTEM <br />GFR <br />GROUND FAULT RELAY <br />G <br />GROUND <br />IG <br />ISOLATED GROUND <br />ISC <br />SHORT CIRCUIT CURRENT <br />JB/J-BOX <br />JUNCTION BOX <br />LF <br />LINEAR FEET <br />LRA <br />LOCKED ROTOR AMPS <br />LTG/LTS <br />LIGHTING/LIGHTS <br />MAU <br />MAKE-UP AIR UNIT <br />MAX <br />MAXIMUM <br />MCA <br />MINIMUM CIRCUIT AMPACITY <br />MCB <br />MAIN CIRCUIT BREAKER <br />MCC <br />MOTOR CONTROL CENTER <br />MFR <br />MANUFACTURER <br />MIN <br />MINIMUM <br />MLO <br />MAIN LUGS ONLY <br />MLV <br />MAGNETIC LOW -VOLTAGE <br />MOCP <br />MAXIMUM OVERCURRENT <br />PROTECTION <br />MTD <br />MOUNTED <br />N/A <br />NOT APPLICABLE <br />NF <br />NON -FUSED <br />NL <br />NIGHT LIGHT (24HR ON) <br />NRTL <br />NATIONALLY RECOGNIZED <br />TESTING LABORATORY <br />(CSA,ETL,NSF,UL) <br />NTS <br />NOT TO SCALE <br />OS <br />OCCUPANCY SENSOR <br />P <br />POLE <br />PART <br />PARTIAL CIRCUIT <br />PH/O <br />PHASE <br />PNL <br />PANEL <br />PNLBD <br />PANELBOARD <br />PROVIDE FURNISH AND INSTALL <br />PT <br />POTENTIAL TRANSFORMER <br />QTY <br />QUANTITY <br />R/REL <br />RELOCATE <br />RCPT <br />RECEPTACLE <br />RLA <br />RUNNING LOAD AMPS <br />RTU <br />ROOFTOP UNIT <br />SCCR <br />SHORT-CIRCUIT CURRENT <br />RATING <br />SD <br />SMOKE DUCT DETECTOR <br />SF <br />SQUARE FEET <br />SPDT <br />SINGLE -POLE, <br />DOUBLE -THROW <br />SPST <br />SINGLE -POLE, <br />SINGLE -THROW <br />SSBJ <br />SUPPLY-SIDE BONDING JUMPER <br />ST <br />SHUNT TRIP <br />SWBD <br />SWITCHBOARD <br />SWGR <br />SWITCHGEAR <br />TBB <br />TELECOMMUNICATIONS <br />BONDING BACKBONE <br />TBD <br />TO BE DETERMINED <br />TGB <br />TELECOMMUNICATIONS <br />GROUND BUS BAR <br />TL <br />TWISTLOCK <br />TMGB <br />TELECOMMUNICATIONS MAIN <br />GROUND BUS BAR <br />TX/XFMR TRANSFORMER <br />TYP <br />TYPICAL <br />U/F <br />UNDERFLOOR <br />U/G <br />UNDERGROUND <br />U/S <br />UNDERSLAB <br />UH <br />UNIT HEATER <br />LINO <br />UNLESS NOTED OTHERWISE <br />UPS <br />UNINTERRUPTIBLE POWER <br />SUPPLY <br />VD <br />VOLTAGE DROP <br />VFD <br />VARIABLE FREQUENCY DRIVE <br />VS <br />VACANCY SENSOR <br />W <br />WIRE <br />W/ <br />WITH <br />WP <br />WEATHER PROOF <br />WR <br />WEATHER RESISTANT <br />WT <br />WATERTIGHT <br />XP <br />EXPLOSION -PROOF <br />THROUGHOUT THE DRAWINGS DIFFERENT LINETYPES ARE USED IN COMBINATION WITH <br />THE SYMBOLS TO INDICATE THE STATUS OF ITEMS AS EXISTING, TO BE DEMOLISHED, TO <br />BE INCLUDED AS PART OF NEW WORK AND/OR ITEMS WHICH ARE ANTICIPATED TO BE <br />PROVIDED IN THE FUTURE. THE STATUS OF ITEMS USING THESE LINETYPES ARE RELATIVE <br />TO THE VIEW IN WHICH THEY APPEAR. PHASING SHOWN IN DRAWINGS IS NOT INTENDED <br />TO FULLY DESCRIBE ALL NECESSARY CONSTRUCTION PHASING, WHICH IS DETERMINED BY <br />THE CONTRACTOR AS PART OF THEIR RESPONSIBILITIES. ANY SUCH PHASES DESCRIBED <br />IN THE CONSTRUCTION DOCUMENTS ARE GENERAL AND ONLY INTENDED TO INDICATE A <br />BROAD ORDER FOR THE SAKE OF DESCRIBING THE PROJECT. THE FOLLOWING LINETYPES <br />MAY BE USED ON ANY DEVICE, EQUIPMENT, NOTE, LINE, SHAPE, ETC. <br />EXISTING I I NEW <br />DEMOLISH - - - - - - - - - - -- FUTURE — — — — — — — — <br />ANNOTATION <br />OMECHANICAL OR FIRE PROTECTION PLAN NOTE CALLOUT <br />OPLUMBING PLAN NOTE CALLOUT <br />lflELECTRICAL OR FIRE ALARM PLAN NOTE CALLOUT <br />OTECHNOLOGY PLAN CALLOUT <br />PLUMBING EQUIPMENT DESIGNATION. (CONTRACTOR FURNISHED AND <br />OINSTALLED). <br />REFER TO PLUMBING FIXTURE OR EQUIPMENT <br />SCHEDULES <br />EQUIPMENT DESIGNATION (OWNER FURNISHED, CONTRACTOR <br />INSTALLED) <br />CU <br />MECHANICAL EQUIPMENT DESIGNATION (CONTRACTOR FURNISHED <br />1 <br />AND INSTALLED UNLESS NOTED OTHERWISE) <br />CONNECTION POINT OF NEW WORK TO EXISTING <br />1 <br />DETAIL REFERENCE UPPER NUMBER INDICATES DETAIL NUMBER <br />E1 <br />LOWER NUMBER INDICATES SHEET NUMBER <br />1 <br />E1 <br />SECTION CUT DESIGNATION <br />7 5 HOMERUN TO PANELBOARD. INFORMATION AT ARROWS ARE CIRCUIT <br />3 NUMBERS AND PANELBOARD FOR TERMINATION. REFER TO <br />OR [R-#1 P1 PANELBOARD SCHEDULES FOR BRANCH CIRCUIT CONDUCTOR SIZES. <br />P1-3,5,7 <br />INDICATES RELAY NUMBER <br />CIRCUIT CONTINUATION OR PARTIAL CIRCUIT <br />CONDUIT CONCEALED <br />CONDUIT CONCEALED (EMERGENCY) <br />CONDUIT IN/UNDER FLOOR/GROUND CONSTRUCTION <br />EXPOSED CONDUIT <br />EXPOSED CONDUIT (EMERGENCY) <br />FLEXIBLE CONDUIT <br />LOW VOLTAGE CABLE (NOT ROUTED IN CONDUIT) <br />E) CONDUIT TURNING DOWN <br />­0 CONDUIT TURNING UP <br />ICONNECTION POINT OR EQUIPMENT TERMINATION <br />---- N EQUIPMENT TERMINATION <br />WHERE TICK MARKS ARE SHOWN, THE FOLLOWING SHALL GOVERN: <br />SWITCHED HOT (PHASE) CONDUCTORS (SHOWN TRAILING <br />NEUTRAL) <br />NEUTRAL(GROUNDED)CONDUCTOR <br />UNSWITCHED HOT (PHASE) CONDUCTORS (SHOWN LEADING <br />NEUTRAL) <br />xx <br />NOTE: HASH MARKS INDICATE QUANTITY OF CONDUCTORS <br />EQUIPMENT GROUNDING CONDUCTOR IN CONDUIT (GREEN <br />INSULATION OR BARE) <br />ISOLATED GROUNDING CONDUCTOR IN CONDUIT (GREEN <br />INSULATION WITH YELLOW TRACER) <br />BRANCH CIRCUIT CONDUCTOR TABLE <br />WHERE TICK MARKS ARE NOT SHOWN, THE FOLLOWING SHALL GOVERN: <br /># OF POLES HOT (PHASE)* NEUTRAL (GROUNDED)** GROUNDING*** <br />1P (1) (1) UNO (1) <br />2P (2) (1) LINO (1) <br />3P (3) (1) UNO (1) <br />PROVIDE ADDITIONAL CONDUCTORS THROUGH ENTIRE CIRCUIT (SWITCHED, <br />UNSWITCHED/EM, ETC.) AS INDICATED THROUGHOUT CONSTRUCTION DOCUMENTS <br />AND AS REQUIRED FOR A COMPLETE AND WORKING SYSTEM. <br />** REFER TO SPECIFICATIONS FOR LIMITATIONS ON SHARING NEUTRAL (GROUNDED) <br />CONDUCTORS. DO NOT CIRCUIT AS A MULTI -WIRE BRANCH CIRCUIT, LINO. <br />*** PROVIDE ADDITIONAL ISOLATED GROUNDING CONDUCTORS WHERE INDICATED. <br />REFER TO SPECIFICATIONS, PLANS, NOTES, WIRING AND CONTROL DIAGRAMS FOR <br />ADDITIONAL CIRCUITING REQUIREMENTS. <br />LIGHTING <br />A a <br />LIGHT FIXTURE <br />a = LOWER CASE LETTER IS SWITCH IDENTIFIER <br />0 <br />A = UPPER CASE LETTER INDICATES LIGHT FIXTURE TYPE <br />0 k <br />J_ = WALL MOUNT <br />O ®) <br />> = ARROW INDICATES AIMING DIRECTION <br />® <br />LIGHT FIXTURE CIRCUITED AS A NIGHT LIGHT (NL) <br />®EMERGENCY <br />LIGHT FIXTURE WITH EMERGENCY LIGHTING BATTERY <br />TO <br />PACK OR CONNECTED EMERGENCY SOURCE <br />NIGHT LIGHT/EMERGENCY LIGHT FIXTURE WITH EMERGENCY BATTERY <br />PACK OR CONNECTED TO EMERGENCY SOURCE <br />p <br />LIGHT FIXTURE WITH DUAL BALLASTS CIRCUITED SEPARATELY <br />(SHADING IMPLIES EMERGENCY LIGHT FIXTURE) <br />V '7 '7 #1 <br />LIGHTING TRACK (# INDICATES RELAY NUMBER) <br />0 0 0 o <br />MIRROR LIGHTS <br />0--0 0-1--1 <br />EXTERIOR PARKING LOT LIGHT FIXTURE <br />OO <br />EXTERIOR PEDESTRIAN POST TOP LIGHT FIXTURE <br />O <br />EXTERIOR LIT BOLLARD LIGHT FIXTURE <br />EXIT SIGN - CEILING / WALL MOUNTED, ARROWS AS INDICATED, FACE <br />HATCHED <br />LJ <br />EMERGENCY LIGHTING UNIT EQUIPMENT WITH BATTERY PACK - <br />CEILING/WALL MOUNTED <br />® <br />AFEA (AREA FOR EVACUATION ASSISTANCE) SIGN - CEILING/WALL <br />MOUNTED, ARROWS AS INDICATED <br />REFER TO LIGHT FIXTURE SCHEDULE FOR MORE INFORMATION. <br />= <br />ELECTRICAL PANELBOARD (SURFACE OR FLUSH MOUNT) <br />0 <br />ELECTRICAL CABINET (SURFACE OR FLUSH MOUNT), TYPE AS NOTED <br />PLYWOOD TERMINAL BOARD FOR TELEPHONE SYSTEM, LINO. SIZE AS <br />NOTED <br />® <br />SWITCHBOARD OR MOTOR CONTROL CENTER ON HOUSEKEEPING PAD <br />® <br />ELECTRICAL DISTRIBUTION PANELBOARD <br />TRANSFORMER <br />DISCONNECT SWITCH - "200/3/150/3R" DENOTES <br />200/3/150/3R <br />AMPERES/POLE/FUSE/NEMA ENCLOSURE RATING, NF= NON -FUSED, <br />CB= CIRCUIT BREAKER (200/3/CB), NO VALUE (200/3/150) FOR NEMA <br />ENCLOSURE MEANS STANDARD NEMA 1 RATING <br />COMBINATION DISCONNECT (SAFETY) SWITCH AND MOTOR STARTER <br />30/3/15/1/3R <br />"30/3/15/1/3R" DENOTES AMPERES/POLE/FUSE/NEMA STARTER <br />L® <br />SIZE/NEMA ENCLOSURE RATING. NF= NON -FUSED, CB= CIRCUIT <br />BREAKER (30/3/CB/1), NO VALUE (200/3/150/1) FOR NEMA ENCLOSURE <br />MEANS STANDARD NEMA 1 ENCLOSURE RATING <br />® 2 <br />MAGNETIC MOTOR STARTER, NEMA SIZE AS NOTED. 3-POLE, LINO <br />VFD <br />VARIABLE FREQUENCY DRIVE <br />INDICATING LIGHT <br />EMERGENCY POWER OFF BUTTON <br />• • <br />STOP -START PUSH BUTTON CONTROL STATION <br />••• <br />HAND -OFF -AUTO PUSH BUTTON CONTROL STATION <br />MUSHROOM -TYPE PUSH BUTTON <br />OVERHEAD PADDLE FAN <br />BOXES, LIGHTING CONTROL & WIRING DEVICES <br />SWITCH LETTER DESIGNATIONS AS FOLLOWS: <br />BLANK = SINGLE POLE <br />2 = TWO POLE <br />3 = THREE-WAY <br />4 = FOUR-WAY <br />D = DIMMER <br /># F = FAN SPEED CONTROL <br />FH = FRACTIONAL HORSEPOWER MANUAL CONTROLLER <br />IH = INTEGRAL HORSEPOWER MANUAL CONTROLLER <br />K = KEYED <br />LV# = LOW VOLTAGE / DIGITAL <br />M = MANUAL MOTOR STARTER DISCONNECT <br />OS# = OCCUPANCY SENSOR <br />WP = WEATHER PROOF <br />#, OS-MW, P2, P2RL, P4, P4S OR P4RL = REFER TO LIGHTING CONTROL <br />DEVICE SCHEDULE <br />VC# = VACANCY SENSOR <br />ALC AUTOMATIC LOAD CONTROL RELAY <br />BTS BRANCH CIRCUIT TRANSFER SWITCH <br />C# CONTACTOR (SIZE, COIL VOLTAGE AND NUMBER OF POLES AS INDICATED) <br />© TRACK -MOUNTED CURRENT LIMITER (## INDICATES AMPERAGE) <br />PHOTOELECTRIC SWITCH <br />TS# TIME SWITCH <br />LC LIGHTING CONTROLS PROCESSOR AND/OR EQUIPMENT <br />HUB VIVE HUB (SEE VIVE HUB DEVICE SCHEDULE FOR HUB TYPE & LIGHTING <br />CONTROL DEVICE SCHEDULE FOR MODEL INFORMATION.) <br />PP POWER PACK (SEE LIGHTING CONTROL SCHEDULE FOR POWPAK SELECTION & <br />LIGHTING CONTROL DEVICE SCHEDULE FOR POWPAK MODEL INFORMATION.) <br />DL DAYLIGHT SENSOR (SEE LIGHTING CONTROL DEVICE SCHEDULE FOR MODEL <br />INFORMATION.) <br />OC CEILING MOUNTED OCCUPANCY SENSOR (SEE LIGHTING CONTROL DEVICE <br />SCHEDULE FOR MODEL INFORMATION.) <br />SIMPLEX RECEPTACLE - NEMA 5-20R, LINO <br />DUPLEX RECEPTACLE - NEMA 5-20R, LINO <br />DOUBLE DUPLEX RECEPTACLE - NEMA 5-20R, LINO <br />SPECIAL RECEPTACLE - NEMA TYPE AS NOTED <br />TWIST -LOCK TYPE RECEPTACLE <br />© <br />BLANK FACE GFCI FEED THROUGH DEVICE <br />OR (BGFCI <br />VVVVYYYY <br />GFCI TYPE RECEPTACLE' <br />a OR <br />(BIG <br />ISOLATED GROUND TYPE RECEPTACLE"` <br />4 OR f M <br />EMERGENCY RECEPTACLE` <br />RECEPTACLE INSTALLED ABOVE COUNTER OR BACKSPLASH* <br />RECEPTACLE INSTALLED IN CEILING* <br />® <br />RECEPTACLE INSTALLED IN FLOOR* <br />RECEPTACLE INSTALLED VIA DROP CORD* <br />ADDITIONAL RECEPTACLE LETTER DESIGNATIONS AS FOLLOWS: <br />C = AUTOMATICALLY CONTROLLED <br />CH = CLOCK HANGER TYPE <br />G = RCPT PROTECTED BY GFCI CIRCUIT BREAKER OR UPSTREAM <br />GFCI DEVICE <br />H = HORIZONTALLY MOUNTED <br />�# <br />S = MANUALLY SWITCHED <br />SP / TVSS = SURGE PROTECTION <br />TR = TAMPER RESISTANT <br />TV = TELEVISION <br />USB = USB/DUPLEX <br />WP = WEATHER PROOF COVER <br />WR = WEATHER RESISTANT <br />• • • • <br />MULTI -OUTLET ASSEMBLY <br />- <br />TELEPHONE OUTLET <br />® <br />DATA OUTLET <br />MULTI -SERVICE OUTLET; TELEPHONE AND DATA <br />\ ` ABOVE COUNTER, TYP <br />WALL, TYP <br />FLOOR, TYP <br />A <br />MULTI -SERVICE POWER POLE WITH TELEPHONE, DATA AND POWER <br />z <br />OUTLETS A = TYPE, REFER TO PLANS, SCHEDULES AND <br />SPECIFICATIONS <br />MULTI -SERVICE FLOOR BOX WITH TELEPHONE, DATA AND POWER <br />�A <br />OUTLETS A = TYPE, REFER TO PLANS, SCHEDULES AND <br />SPECIFICATIONS <br />OA <br />POKE THROUGH, A = TYPE, REFER TO PLANS, SCHEDULES AND <br />SPECIFICATIONS <br />�T <br />THERMOSTAT <br />fl O <br />JUNCTION/OUTLET BOX <br />SP <br />SPEAKER <br />AP <br />WIRELESS ACCESS POINT <br />SYMBOL DEMONSTRATED WITH DUPLEX RECEPTACLE, WHEN USED IN COMBINATION <br />WITH OTHER DEVICES MEANING IS SIMILAR FOR THOSE DEVICE TYPES. <br />REFER TO LIGHTING CONTROL DEVICE SCHEDULE FOR MORE INFORMATION. <br />ELECTRICAL ONE -LINE & RISER DIAGRAM <br />SWITCH (RATING AS INDICATED) <br />1 3P <br />C� PA DRAWOUT CIRCUIT BREAKER (RATINGS AS INDICA <br />v <br />##A FUSED SWITCH (RATING, POLES AND FUSE TYPE AS IN ICATED) <br />ID#AB <br />3P <br />-AP COMBINATION FUSED SWITCH/STARTER AND STARTER SIZE <br />'E.A" PE <br />EMA# <br />ICIRCUIT BREAKER (RATINGS AS INDICATED) MaStE <br />PA 3P <br />CI I <br />I11111AI • <br />31113 COMBINATION CIRCUIT BREAKER/STARTER AND STAR RWte. <br />IS <br />❑ m PANELBOARD, SINGLE OR MULTI -SECTION (REFER TO <br />ISOLATED POWER PANELBOARD W/ INTEGRAL TRANSFORMER <br />r <br />(REFER TO SCHEDULES) <br />Tx# <br />TRANSFORMER (TYPE AND RATINGS AS INDICATED) <br />TX# <br />SHIELDED TRANSFORMER (TYPE AND RATINGS AS INDICATED) <br />ATS# <br />AUTOMATIC TRANSFER SWITCH (RATINGS AS INDICATED) <br />I� ##A <br />ATS# <br />(W/BYPASS) <br />AUTOMATIC TRANSFER SWITCH WITH BYPASS (RATINGS AS <br />INDICATED) <br />##A <br />## KW GENERATOR <br />10, 4W <br />1111Y1111V, <br />M/G GENERATOR (RATINGS AS INDICATED) <br />##A. 3P <br />_ - NON -SEPARATELY DERIVED SOURCE <br />OR <br />SEPARATELY DERIVED SOURCE <br />MDPSWITCHBOARD ELEC ROOM <br />##DAMPS 4BOY/27TV304W SWITCHGEAR, SWITCHBOARD AND/OR DISTRIBUTION <br />PANELBOARD (TYPE, RATING, DEVICES AND <br />ACCESSORIES AS INDICATED) <br />DIGITAL <br />VM AM COMBINATION DIGITAL VOLT METER/AMMETER <br />### CIRCUIT IDENTIFICATION (REFER TO CIRCUIT SCHEDULE) <br />GFR GROUND FAULT RELAY <br />PFR PHASE FAILURE RELAY <br />HE KIRK -KEY INTERLOCK (# INDICATES KEY PAIR) <br />ST SHUNT TRIP <br />AM AMMETER (RANGE AS SPECIFIED OR REQUIRED) <br />VM VOLTMETER (RANGE AS SPECIFIED OR REQUIRED) <br />UTILITY <br />METER M UTILITY METER (AS REQUIRED BY UTILITY) <br />AS AMMETER SWITCH <br />VS VOLTMETER SWITCH <br />WH D WATT-HOUR METER, "D" DENOTES DEMAND REGISTER, "15' <br />15 DENOTES MINUTES OF DEMAND INTERVAL <br />CURRENT TRANSFORMER RATING AS SPECIFIED OR REQUIRED <br />POTENTIAL TRANSFORMER RATING AS SPECIFIED OR REQUIRED <br />SPD SURGE -PROTECTIVE DEVICE <br />•--I GROUND CONNECTION <br />GROUND CONNECTION WITH TEST WELL <br />Q—� GROUND ROD <br />LIGHTNING ARRESTER <br />H CAPACITOR <br />- CONTACT (OPEN OR CLOSED) <br />HEATER <br />HP MOTOR <br />BLOCK LOAD KW OR KVA <br />X F# X FP# FAULT POINT REFERENCED IN SHORT CIRCUIT CURRENT AND <br />VOLTAGE DROP SPREADSHEET <br />Arch i t e c t u ra I <br />Corporation <br />9431 HAVEN AVENUE, SUITE 212 <br />RANCHO CUCAMONGA, CA 91730 <br />P. 909.259.9971 1 F. 909.944.8409 <br />www.AmorArch.com <br />BRISTOL CENTER <br />PROPERTIES LLC <br />714 S PLYMOUTH BLVD <br />LOS ANGELES, CA 90005 <br />AMIR HOURIANI <br />aihouriani@gmail.com <br />CONSULTANT <br />MECHANICAL I ELECTRICAL I PLUMBING <br />909-997-0905 <br />CARLOS RIVAS <br />carlos@rivasdesignconsultants.com <br />Z <br />F- <br />U O <br />wF— <br />� Q <br />OU <br />Q�O <br />0- .J <br />I— <br />z <br />5W <br />G <br />O <br />J <br />W <br />W <br />0 <br />W <br />I— <br />� O <br />W ti <br />N <br />J O <br />OU <br />IY Q <br />co Z <br />Z Q <br />O Z <br />Cfl <br />U) <br />STAMP <br />z <br />O <br />Q <br />LLJ <br />Of <br />Q <br />z <br />Q <br />0 <br />2-7 <br />LL1 <br />Lu <br />J <br />U) <br />J <br />O <br />cm <br />G <br />U) <br />J <br />w 0 <br />J _ <br />H <br />~ <br />w Lu <br />J <br />Lu Lu <br />�I i I <br />• <br />-24421 <br />8/31/2025 <br />Nc* RENEWAL <br />DATE �Q <br />qT o CA0F�� <br />DATE SIGNED: 08/13/2024 <br />SHEETS BEARING THIS SEAL AND WET SIGNATURE <br />ARE AUTHENTICATED. RESPONSIBILITY FOR ALL <br />OLDER PLANS, SPECIFICATIONS OR INSTRUMENTS <br />ARE DISCLAIMED. <br />REVISIONS <br />DATE <br />2024.08.15 <br />PROJECT NUMBER <br />A2641 <br />SHEET NUMBER <br />COPYRIGHT 2024 - DESIGNS, DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF THE DESIGN PROFESSIONAL. REPRODUCTION PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE DESIGN PROFESSIONAL. <br />E0.2 <br />