Laserfiche WebLink
October 1, 2013 SIGN COMPONENTS MANUAL (SAM) 96 <br />2. The load connected to the Class 2 output of the LED Drivers other than Cat. Nos. PLN-30-36 and PLN-30-48 are suitable for <br />use in dry, damp and wet locations. The load connected to Cat. Nos. PLN-30-36 and PLN-30-48 are suitable for use in dry and <br />damp locations. <br />3. In the end product, power supply spacing to other heat producing components shall be min. 2 inches spacing to sidewalls, and <br />min. 2 inches spacing to top of enclosure. <br />4. These products are provided with the following electrical ratings: <br />Input Output <br />Model V ac Hz A V dc A <br />PLN-30-9 100-240, 277 50/60 0.45, 0.15 9 3.3 <br />PLN -30-12 100-240, 277 50/60 0.45,0.15 12 2.5 <br />PLN-30-15 100-240,277 50/60 0.45,0.15 15 2.0 <br />PLN-30-20 100-240, 277 50/60 0.45, 0.15 20 1.5 <br />PLN-30-24 100-240, 277 50/60 0.45,0.15 24 1.25 <br />PLN-30-27 100-240,277 50/60 0.45,0.15 27 1.12 <br />PLN-30-36 100-240, 277 50/60 0.45, 0.15 36 0.84 <br />PLN-30-48 100-240, 277 50/60 0.45,0.15 48 0.63 <br />5. These products shall be enclosed in the end product. <br />6. These units are intended for factory installation only. <br />7. Model PLN-30-48 is suitable for use in the United States only. <br />LED array drivers, Model CEN-60-Y Series, where Y can be 12,15, 20,24, 30, 36, 42, 48 or 54 for output voltage; Model CEN- <br />75-Y, where Y can be 15,20, 24, 30, 36,42,48 or 54 for output voltage. <br />1. These power supplies have been evaluated to Class 2 output requirements for dc circuits with a maximum of one Class 2 <br />output. <br />2. These products are orovided with the following electrical ratings: <br />Input (ac)Output (dc) <br />Model V A Hz V A <br />CEN-60-12 100-240 0.8 50/60 12 5 <br />277 0.3 <br />CEN-60-15 100-240 0.8 50/60 15 4 <br />277 0.3 <br />CEN-60-20 100-240 0.8 50/60 20 3 <br />277 0.3 <br />CEN-60-24 100-240 0.8 50/60 24 2.5 <br />277 0.3 <br />CEN-60-30 100-240 0.8 50/60 30 2 <br />277 0.3 <br />CEN-60-36 100-240 0.8 50/60 36 1.7 <br />277 0.3 <br />CEN-60-42 100-240 0.8 50/60 42 1.45 <br />277 0.3 <br />CEN-60-48 100-240 0.8 50/60 48 1.3 <br />277 0.3 <br />CEN-60-54 100-240 0.8 50/60 54 1.15 <br />277 0.3 <br />CEN-75-15 100-240 1.1 50/60 15 5 <br />277 0.4 <br />CEN-75-20 100-240 1.1 50/60 20 3.75 <br />277 0.4 <br />CEN-75-24 100-240 1.1 50/60 24 3.15 <br />277 0.4 <br />CEN-75-30 100-240 1.1 50/60 30 2.5 <br />277 0.4 <br />CEN-75-36 100-240 1.1 50/60 36 2.1 <br />277 0.4 <br />CEN-75-42 100-240 1.1 50/60 42 1.8 <br />277 0.4 <br />CEN-75-48 100-240 1.1 50/60 48 1.57 <br />277 0.4 <br />CEN-75-54 100-240 1.1 50/60 54 1.4 <br />277 0.4 <br />3. The Class 2 output of these power supplies are suitable for use in dry and damp locations. <br />4. In the end product, power supply spacing to other heat producing components and to sidewalls shall be minimum 4 inch, 1 inch <br />end to end and minimum 2 inches spacing to top of enclosure. <br />5. These products shall be enclosed in the end product.