Laserfiche WebLink
DATE:11/14/2024 <br />JOB NO: MLB24-1210 <br />DESIGNED BY: HK <br />CHECKED BY: GB <br />DE <br />S <br />C <br />R <br />I <br />P <br />T <br />I <br />O <br />N <br />DA <br />T <br />E <br />RE <br />V <br />BY <br />1 3 4 5 <br />- <br />2 <br />- <br />- <br />MLB CONSULTING AND <br />ENGINEERING, INC <br />7918 FOOTHILL BLVD <br />SUNLAND, CA 91040 <br />(818) 521-6342 <br />INFO@MLBENGINEERING.ORG <br />4703 W McFadden <br />Ave Santa Ana, CA <br />92704 <br />DATE:11/14/2024 <br />JOB NO: MLB24-1210 <br />DESIGNED BY: HK <br />CHECKED BY: GB <br />DE <br />S <br />C <br />R <br />I <br />P <br />T <br />I <br />O <br />N <br />DA <br />T <br />E <br />RE <br />V <br />BY <br />1 3 4 5 <br />- <br />2 <br />- <br />- <br />MLB CONSULTING AND <br />ENGINEERING, INC <br />7918 FOOTHILL BLVD <br />SUNLAND, CA 91040 <br />(818) 521-6342 <br />INFO@MLBENGINEERING.ORG <br />4703 W McFadden <br />Ave Santa Ana, CA <br />92704 <br />STRUCTURAL STEEL <br />REFERENCE STANDADS: CONFORM TO: <br />1. CBC CHAPTER 22- “STEEL” <br />2. NASI/AISC 303-10- “CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS & BRIDGES” <br />3. ANSI/AISC 325-10- “STEEL CONSTRUCTION MANUAL” <br />4. ANSI/AISC 360-10- “SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS” <br />5. AWS D1.1:2010- “STRUCTURAL WELDING CODE-STEEL” <br />6. 2009 RCSC- “SPECIFICATION FOR STRUCTURAL JOINTS USING HIGH-STRENGTH BOLTS” <br />7. ANSI/AISC 341-10- “SEISMIC PROVISIONS FOR STRUCTURAL STEEL BUILDINGS” <br />8. AWS D1.8:2009- “STRUCTURAL WELDING CODE- SEISMIC SUPPLEMENT” <br />SPECIAL PROVISIONS FOR ELEMENTS OF THE SEISMIC FORCE RESISTING SYSTEM (SFRS): SELECTED STEEL <br />ELEMENTS OF THIS PROJECT ARE PART OF THE SEISMIC FORCE RESISTING SYSTEM” (SFRS) AND, THUS ARE SUBJECT <br />TO SPECIAL REQUIREMENTS DETAILED IN THE AISC “SEISMIC PROVISIONS”. ELEMENTS OF THE SFRS DESIGNATED ON <br />PLANS. REFER TO DRAWING LEGEND FOR SYMBOLS USED TO DESIGNATE ELEMENTS ON THE PLANS AND <br />STRUCTURAL STEEL SEISMIC PROVISIONS SECTION OF GENERAL NOTES FOR SUPPLEMENTAL REQUIREMENTS. <br />SUBMITTALS: SUBMIT THE FOLLOWING DOCUMENTS TO THE SER FOR REVIEW: <br />1.SHOP DRAWINGS COMPLYING WITH AISC 360 SECTIONS M1 AND N3 AND AISC 303 SECTION 4. <br />2.ERECTION DRAWINGS COMPLYING AISC 360 SECTION M1 AND N3 AND AISC 303 SECTION 4 <br />3.WELD PROCEDURE SPECIFICATION (WPS'S) FOR SHOP AND FIELD WELDING. <br />4.MANUFACTURER'S CERTIFICATES OF CONFORMANCE FOR ELECTRODES, FLUXES AND GASES (WELDING <br />CONSUMABLES). <br />MAKE COPIES OF THE FOLLOWING DOCUMENTS “AVAILABLE UPON REQUEST” TO THE SER OR OWNER'S INSPECTION <br />AGENCY IN ELECTRONIC OR PRINTED FORM PRIOR TO FABRICATION PER AISC 360 SECTION N3.2 REQUIREMENTS: <br />1.FABRICATOR'S WRITTEN QUALITY CONTROL MANUAL THAT INCLUDES, AS A MINIMUM: <br />1.a. MATERIAL CONTROL PROCEDURES <br />1.b. INSPECTION PROCEDURES <br />1.c. NON-CONFORMANCE PROCEDURES <br />2.STEEL & ANCHOR ROD SUPPLIERS' MATERIAL TEST REPORTS (MTR'S) INDICATING THE COMPLIANCE WITH <br />SPECIFICATIONS. <br />3.FASTENER MANUFACTURER'S CERTIFICATION DOCUMENTING CONFORMANCE WITH THE SPECIFICATION. <br />4.FILLER METAL MANUFACTURER'S PRODUCT DATA FOR SMAW, FCAW AND GMAW INDICATING: <br />4.a. PRODUCT SPECIFICATION COMPLIANCE <br />4.b. RECOMMENDED WELDING PARAMETERS <br />4.c. RECOMMENDED STORAGE AND EXPOSURE REQUIREMENTS INCLUDING BAKING <br />4.d. LIMITATIONS OF USE <br />5.WELDED HEADED (SHEAR) STUD ANCHORS MANUFACTURER'S CERTIFICATIONS INDICATING AND MEET <br />SPECIFICATIONS. <br />6.PROCEDURE QUALIFICATION RECORDS (PQP'S FOR WPS'S THAT ARE NOT PREQUALIFIED IN ACCORDANCE WITH <br />AWS. <br />7.WELDING PERSONNEL PERFORMANCE QUALIFICATION RECORDS (WPQP) AND CONTINUITY RECORDS <br />CONFORMING TO AWS STANDARDS. <br />MATERIALS: <br />STRUCTURAL STEEL MATERIALS SHALL CONFORM TO MATERIALS AND REQUIREMENTS LISTED IN AISC 360 SECTION <br />A3 INCLUDING, BUT NOT LIMITED TO: <br />STRUCTURAL JOINTS USING HIGH-STRENGTH BOLT: <br />1. ASTM A325-N BOLTS- “THREADS NOT EXCLUDED IN THE SHEAR PLANE.” <br />2. HIGH-STRENGTH BOLTED JOINTS HAVE BEEN DESIGNED AS 'BEARING” CONNECTIONS. <br />3. PROVIDE ASTM BOLT GRADE AND TYPE AS SPECIFIED IN THE MATERIALS SECTION ABOVE. <br />4. PROVIDE WASHERS OVER OUTER PLY OF SLOTTED HOLES AND OVERSIZE HOLES PER RCSC TABLE 6.1. <br />5. PROVIDE NUT AND WASHERS GRADES, TYPES AND FINISHES CONFORMING TO RCSC SPECIFICATION TABLE 2.1. <br />6. PROVIDE FASTENER ASSEMBLIES FROM A SINGLE SUPPLIER. <br />7. JOINT TYPES SHALL BE: <br />8. ST - “SNUG TIGHT FOR TYPICAL BEAM END “SHEAR” CONNECTIONS, UNLESS NOTED OTHERWISE. <br />9. SC - “SLIP CRITICAL”, WHERE SPECIFICALLY INDICATED. PROVIDE WITH CLASS A FAYING SURFACE. <br />10. INSTALL BOLTS IN JOINTS IN ACCORDANCE WITH THE RCSC SPECIFICATION SECTION 8 AND TABLE 4.1 <br />11. INSPECTION IS PER RCSC SECTION 9. <br />ANCHORAGE TO CONCRETE: <br />1.EMBEDDED STEEL PLATES FOR ANCHORAGE TO CONCRETE: PLATES (PL) EMBEDDED IN CONCRETE WITH STUDS <br />(WHS) OR DOWEL BAR ANCHORS (DBA) SHALL BE OF THE SIZES AND LENGTHS AS INDICATED ON THE PLANS <br />WITH MINIMUM ½” DIA. WHS X 6” LONG BUT PROVIDE NOT LESS THAN ¾” INTERIOR COVER OR 1 ½” EXTERIOR <br />COVER TO THE OPPOSITE FACE OF CONCRETE, UNLESS NOTED OTHERWISE. <br />2.COLUMN ANCHOR RODS AND BASE PLATES: ALL COLUMNS (VERTICAL MEMBER ASSEMBLIES WEIGHING OVER 300 <br />POUNDS) SHALL BE PROVIDED WITH A MINIMUM OF FOUR ¾” DIAMETER ANCHOR RODS. COLUMN BASE PLATES <br />SHALL BE AT LEAST ¾” THICK, UNLESS NOTED OTHERWISE. CAST-IN-PLACE ANCHOR RODS SHALL BE PROVIDED <br />UNLESS OTHERWISE APPROVED BY THE ENGINEER. UNLESS NOTED OTHERWISE, EMBEDMENT OF <br />CAST-IN-PLACE ANCHOR RODS SHALL BE 12 TIMES THE ANCHOR DIAMETER (12D) <br />FABRICATION: <br />1. CONFORM TO AISC 360 SECTION M2 “FABRICATION” AND AISC 303 SECTION 6 “SHOP FABRICATION” <br />2. QUALITY CONTROL (QC) SHALL CONFORM TO: <br />a. AISC 360 CHAPTER N “QUALITY CONTROL AND QUALITY ASSURANCE” AND <br />b. AISC 303 SECTION 8 “QUALITY CONTROL”. <br />c. FABRICATOR AND ERECTOR SHALL ESTABLISH AND MAINTAIN WRITTEN QUALITY CONTROL (QC) <br />PROCEDURES PER AISC 360 SECTION N3. <br />d. FABRICATOR SHALL PREFORM SELF-INSPECTIONS PER AISC 360 SECTION N5 TO ENSURE THAT THEIR WORK <br />IS PERFORMED IN ACCORDANCE WITH CODE OF STANDARD PRACTICE, THE AISC SPECIFICATION, <br />CONTRACT DOCUMENTS AND THE APPLICABLE BUILDING CODE. <br />e. QC INSPECTIONS MAY BE COORDINATED WITH QUALITY ASSURANCE INSPECTIONS PER SECTION N5.3 <br />WHERE FABRICATORS QA PROCEDURES PROVIDE THE NECESSARY BASIS FOR MATERIAL CONTROL, <br />INSPECTION, AND CONTROL OF THE WORKMANSHIP EXPECTED BY THE SPECIAL INSPECTOR <br />WELDING: <br />1. WELDING SHALL CONFORM TO AWS D1.1 AND D1.8 AS APPLICABLE FOR SEISMIC ELEMENTS WITH PREQUALIFIED <br />WELDING PROCESSES EXCEPT MODIFIED BY AISC 360 SECTION J2 AND AISC 341 AS APPLICABLE. WELDERS <br />SHALL BE QUALIFIED IN ACCORDANCE WITH AWS D1.1 (AND D1.8 FOR DEMAND CRITICAL WELDS WHERE <br />APPLICABLE) REQUIREMENTS <br />2. USE 70KSI STRENGTH, LOW-HYDROGEN TYPE ELECTRODES (E7018) OR E71T AS APPROPRIATE FOR THE <br />PROCESS SELECTED. <br />3. WELDING OF HIGH STRENGTH ANCHOR RODS IS PROHIBITED UNLESS APPROVED BY ENGINEER <br />4. WELDING OF HEADED STUD ANCHORS SHALL BE IN ACCORDANCE WITH AWS D1.1 CHAPTER 7 “STUD WELDING” <br />ERECTION: <br />1. CONFORM TO AISC 360 SECTION M4 “ERECTION” AND AISC 303 SECTION 7 “ERECTION” <br />2. CONFORM TO AISC 360 CHAPTER N “QUALITY CONTROL AND QUALITY ASSURANCE” AND AISC 303 SECTION 8 <br />3. THE ERECTOR SHALL MAINTAIN DETAILED ERECTION QUALITY CONTROL PROCEDURES THAT ENSURE THAT THE <br />WORK IS PERFORMED ON ACCORDANCE WITH THESE REQUIREMENTS AND THE CONTRACT DOCUMENTS <br />4. STEEL WORK SHALL BE CARRIED UP TRUE AND PLUMB WITHIN THE LIMITS DEFINES IN AISC 303 SECTION 7.13. <br />5. HIGH STRENGTH BOLTING SHALL COMPLY WITH THE RCSC REQUIREMENTS INCLUDING RCSC SECTION 7.2 <br />“REQUIRED TESTING”, AS APPLICABLE AND AISC 360 CHAPTER J, SECTION M2.5 AND SECTION N5.6. <br />6. WELDING OF HEADED STUD ANCHORS SHALL BE IN ACCORDANCE WITH AWS D1.1 CHAPTER 7 “STUD WELDING. <br />7. PROVIDE HEADED (SHEAR) STUD ANCHORS WELDED THROUGH METAL DECK TO TOPS OF BEAMS DENOTED IN <br />PLANS <br />8. THE CONTRACTOR SHALL PROVIDE TEMPORARY BRACING AND SAFETY PROTECTION REQUIRED AISC 360 <br />SECTION M4.2 AND AISC 303 SECTION 7.10 AND 7.11. <br />PROTECTIVE COATING REQUIREMENTS <br />1. SHOP PAINTING: CONFORM TO AISC 360 SECTION M3 AND AISC 303 SECTION 6.5 UNLESS OTHERWISE SPECIFIED <br />BY THE PROJECT SPECIFICATIONS <br />2. INTERIOR STEEL: <br />a. UNLESS NOTED OTHERWISE, DO NOT PAINT ANY STEEL SURFACES MEETING THE FOLLOWING CONDITIONS: <br />·CONCEALED BY INTERIOR BUILDING FINISHES, <br />·FIREPROOFED, <br />·EMBEDDED IN CONCRETE, <br />·SPECIALLY PREPARED AS A “FAYING SURFACE” FOR TYPE-SC “SLIP-CRITICAL” CONNECTIONS INCLUDING <br />BOLTED CONNECTIONS THAT FORM A PART OF THE SEISMIC FORCE RESISTING SYSTEM GOVERNED BY <br />AISC 341 UNLESS THE COATING CONFORMS TO REQUIREMENTS OF THE RCSC BOLT SPECIFICATION AND IS <br />APPROVED BY THE ENGINEER. <br />·WELDED; IF AREA REQUIRES PAINTING, DO NOT PAINT UNTIL AFTER WELD INSPECTIONS AND <br />NON-DESTRUCTIVE TESTING REQUIREMENT, IS ANY, AE SATISFIED <br />b. INTERIOR STEEL, EXPOSED TO VIEW, SHALL BE PAINTED WITH ONE COAT OF THE SHOP PRIMER UNLESS <br />OTHERWISE INDICATED IN THE PROJECT SPECIFICATIONS. FIELD TOUCH-UPS TO MATCH THE FINISH COAT <br />OF AS OTHERWISE INDICATED IN THE PROJECT SPECIFICATIONS. <br />1.EXTERIOR STEEL: EXPOSED EXTERIOR STEEL SHALL BE PROTECTED BY EITHER: <br />a.PAINT WITH AN EXTERIOR MULTI-COAT SYSTEM AS PER THE PROJECT SPECIFICATIONS. FIELD TOUCH-UP <br />PAINTING SHALL BE AS PER THE PROJECT SPECIFICATIONS. <br />b.GALVANIZING: UNLESS PROTECTED WITH A PAINT SYSTEM, EXPOSED STEEL (OUTSIDE THE BUILDING <br />ENVELOPE) SHALL BE HOT DIPPED GALVANIZED, WHERE NOTED ON PLANS OTHERWISE INDICATED BY THE <br />FINISHES SPECIFIED BY THE ARCHITECT. APPLY FIELD TOUCH-UPS PER PROJECT SPECIFICATIONS. <br />ARCHITECTURALLY EXPOSED STRUCTUAL STEEL: STEEL IDENTIFIED BY ARCHITECT ON THE ARCHITECTURAL <br />DRAWINGS AS ARCHITECTURALLY EXPOSED STRUCTURAL STEEL (AESS) SHALL CONFORM AISC 303 SECTION 10 <br />STRUCTURAL STEEL-SEISMIC PROVISIONS <br />REFERENCE STANDARDS: CONFORM TO THE STANDARDS IN THE STRUCTURAL STEEL SECTION AND THE FOLLOWING: <br />1. ANSI/AISC 341-10 - “SEISMIC PROVISIONS FOR STRUCTURAL STEEL BUILDINGS” <br />2. AWS D1.8”2009 - “STRUCTURAL WELDING CODE - SEISMIC SUPPLEMENT” <br />SCOPE: IN ADDITION TO THE STANDARDS SPECIFIED IN THE STRUCTURAL STEEL SECTION OF THESE GENERAL <br />REQUIREMENTS, STRUCTURAL STEEL THAT IS PART OF OR THAT TRANSFERS SEISMIC LOADS TO THE DESIGNATED <br />SEISMIC FORCE RESISTING SYSTEM (SFRS) DEFINED IN THE DESIGN CRITERIA AND LOADS SECTION OF THESE <br />GENERAL REQUIREMENTS, SHALL COMPLY WITH APPLICABLE SEISMIC PROVISIONS BELOW. <br />SEISMIC FORCE RESISTING SYSTEM (SFRS): THE SFRS IS AN ASSEMBLAGE OF BEAMS, COLUMNS, BRACES AND WALLS <br />THAT HAVE BEEN SPECIALLY PROPORTIONED INTO VERTICAL FRAME AND SHEAR WALL] SYSTEMS TO RESIST <br />LATERAL SEISMIC FORCED. BEYOND THE FRAMES AND WALLS ARE TYPICALLY OTHER HORIZONTAL MEMBERS <br />CONNECTING TO THE VERTICAL SHEAR-RESISTING FRAMES AND WALLS THAT “DRAGS”, AND “DIAPHRAGMS” (SUCH AS <br />THE FLOOR SLAB AND ROOF DECK), WHICH ALSO FORM PART OF THE SFRS AND ARE SUBJECT TO THE “SEISMIC <br />PROVISIONS” OF AISC 341. <br />DESIGNATION OF PRIMARY SFRS FRAMING SYSTEM FOR THIS PROJECT IS PROVIDED IN THE DESIGN CRITERIA AND <br />LOADS SECTION OF THESE GENERAL REQIREMENTS. STABILITY OF THE STRUCTURE UNDER SEISMIC LOADS IS <br />RELIANT UPON STRUCTURAL STEEL COLLECTORS, DRAG AND DIAPHRAGM CHORDS WHICH ARE GOVERNED BY THE <br />SEISMIC PROVISIONS. <br />LOWEST ANTICIPATED SERVICE TEMPERATURE (LAST): THE PRIMARY SFRS FRAMING FOR THIS PROJECT IS TO BE <br />ENCLOSED AND EXPECTED TO B MAINTAINED WITH THE LAST OF 50 DEGREES FAHRENHEIT. <br />STRUCTURAL MEMBERS AND THEIR CONNECTIONS CONSIDERED IN THE DESIGN OF THE SFRS ARE SUBJECT TO THE <br />SPECIAL SEISMIC PROVISIONS OF THIS SECTION. SUBJECT ELEMENTS REQUIRE SPECIAL ATTENTION TO DETAILING, <br />MATERIAL CONTROL, DOCUMENTATION, FABRICATION, INSPECTION, AND PROTECTIONS FROM ALL TRADES. SPECIAL <br />REQUIREMENTS INCLUDE BUT ARE NOT LIMITED TO: <br />1.IDENTIFICATION OF SFRS MEMBERS AND THEIR CONNECTIONS ON SHOP AND ERECTION DRAWINGS; INCLUDE <br />SPECIAL DETAILING, WELDING AND INSPECTION REQUIREMENTS AND LIMITATIONS ON WHERE OTHER TRADES <br />ARE RESTRICTED FROM ANY ATTACHMENTS. REFER TO AISC 341 SECTION D1.3 PROTECTED ZONES. <br />2.CONNECTION CONFIGURATIONS DETAILED TO SCALE, INCLUDING THE LAYOUT OF BOLTS, PLATES, WELDS AND <br />ANY SPECIAL ERECTION PROCEDURES AND WELDING SEQUENCE REQUIREMENTS. <br />3. DEMAND CRITICAL WELDS (DCW) SHALL BE NOTED ON SHOP AND ERECTION DRAWINGS. <br />4. MEMBERS AND PLATES SUBJECT TO CHARPY V-NOTCH (CVN) TOUGHNESS TESTING'S. <br />5. INDICATE STEEL ELEMENTS WHERE LOWEST ANTICIPATED SERVICE TEMPERATURE, (LAST) IS BELOW 50 <br />DEGREES F. <br />QUALITY CONTROL AND QUALITY ASSURANCE PLAN: QUALITY CONTROL (QC) (BY CONTRACTOR) AND QUALITY <br />ASSURANCE (QA) (BY AN APPROVED SPECIAL INSPECTION AGENCY) FOR MEMBERS OF THE SFRS SHALL BE <br />PROVIDED IN ACCORDANCE WITH AISC 341, CHAPTER J AND COORDINATED PER SECTION J6.4. <br />1. FABRICATOR AND ERECTOR SHALL HAVE QUALITY CONTROL PROGRAM PER AISC 360 SECTION N2 <br />2. FABRICATOR AND ERECTOR SHALL PROVIDE ACCESS TO THE QUALITY ASSURANCE/SPECIAL INSPECTION <br />AGENCY, PRIOR TO THE START OF WORK, FOR PURPOSES OF REVIEW OF THE QUALITY CONTROL PROGRAM <br />REQUIRED PER AISC 360 SECTION N2 PER CBC 1704.2.5.1 <br />3. SPECIAL INSPECTIONS REQUIRED PER CBC SECTIONS 1705.2.1 AND 1705.11.1 AND THE STATEMENT OF SPECIAL <br />INSPECTIONS SECTION OF THESE GENERAL REQUIREMENTS. <br />SUBMITTALS: <br />1. SUBMIT FABRICATOR AND ERECTOR DOCUMENTS PER AISC 360 SECTION N3 AND AISC 341 SECTION J2.1. <br />2. SHOP DRAWINGS OF THE SFRS SHALL BE PREPARED IN ACCORDANCE WITH AISC 303 SECTION 4, AISC 341 <br />3. SECTIONS A4.1, A4.2, AND I1 AND SHALL INCLUDE THE FOLLOWING: <br />3.·DESIGNATION OF THE SFRS <br />3.·MEMBER AND CONNECTIONS OF THE SFRS CLEARLY IDENTIFIED <br />3.·PRE-TENSIONED BOLTS AND FAYING SURFACE PREPARATION LOCATIONS IN SFRS <br />3.·WELD ACCESS HOLD DIMENSIONS, SURFACE PROFILE AND FINISH REQUIREMENTS <br />3.·NDT WHERE PERFORMED BY THE FABRICATOR <br />4. WELD PROCEDURES SPECIFICATIONS (WPS'S) <br />5. BOLT INSTALLED PROCEDURES <br />6. CHARPY V-NOTCH CONFORMANCE CERTIFICATION FOR WELDING ELECTRODES, FLUXES AND SHIELDING <br />7. GASES <br />8. MATERIAL DATA FOR DEMAND CRITICAL WELDS PER AISC 341 J2.1(3). <br />9. CHARPY V-NOTCH CONFORMANCE CERTIFICATION/VERIFICATION TEST RESULTS FOR “HEAVY SHAPES” OR <br />10. JUMBO SECTIONS, IF APPLICABLE. <br />11. SPECIFIC ASSEMBLY ORDER, WELDING SEQUENCE, WELDING TECHNIQUE, OR OTHER SPECIAL PRECAUTIONS <br />12. FOR JOINTS OR GROUPS OF JOINTS WHERE SUCH ITEMS ARE DESIGNATED TO BE SUBMITTED TO THE SER. <br />SFRS MATERIALS: STRUCTURAL STEEL PART OF THE SFRS SHALL MEET THE REQUIREMENTS OF AISC 341, SECTION <br />A3.1. REFERENCE THE MATERIALS SECTION OF THE STRUCTURAL STEEL FOR SPECIFIC ASTM SPECIFICATIONS. <br />HEAVY SECTIONS - SPECIAL REQUIREMENTS: IN ADDITION TO AISC 360 A3.1C REQUIREMENTS: <br />HOT-ROLLED SHAPES WITH FLANGES 1 ½ INCH THICK AND THICKER SHALL HAVE A MINIMUM CHARPY V-NOTCH <br />TOUGHNESS OF 20 FT-LBS AT 70 DEGREES F TESTED IN THE ALTERNATE CORE LOCATION AS DESCRIBED IN ASTM A6 <br />SUPPLEMENTARY REQUIREMENT S30 <br />PLATES, 2 INCHES THICK AND THICKER SHALL HAVE A MINIMUM CHARPY V-NOTCH TOUGHNESS OF 20 FT-LBS AT 70 <br />DEGREES F MEASURED AT ANY LOCATION PERMITTED BY ASTM A673, FREQUENCY P, WHERE THE PLATE IS USED <br />FOR: <br />A. CONNECTION PLATES WHERE INELASTIC STRAIN UNDER SEISMIC LOADING IS EXPECTED <br />B. BUILT-UP MEMBERS <br />SFRS BOLTED JOINT REQUIREMENTS: ALL BOLTS SHALL BE INSTALLED AS PRE-TENSIONED HIGH-STRENGTH BOLTS <br />OF SIZE AND ORIENTATIONS AS SHOWN ON THE DRAWINGS. BOLT HOLES SHALL STANDARD HOLES OR <br />SHORT-SLOTTED PERPENDICULAR TO THE APPLIED LOAD UNLESS OTHERWISE NOTED. EXCEPTION: FOR DIAGONAL <br />BRACES IN OCBF, SCBF, OR EBF FRAMES, OVERSIZED HOLES ARE PERMITTED IN ONE CONNECTION PLY PROVIDED <br />BRACE CONNECTION STRENGTH IS BASED ON SLIP-CRITICAL CAPACITIES. ALL BOLTED JOINTS SHALL BE PREPARED <br />WITH CLASS A FAYING SURFACES (OR BETTER) PER RCSC SPECIFICATION SECTION 3.2 AND SHALL HAVE FAYING <br />SURFACES PREPARED AND BOLTS INSTALLED IN ACCORDANCE WITH JOINT TYPE SC - CLASS A (UNCOATED) - <br />“SLIP-CRITICAL” PER RCSC SPECIFICATION TABLE 4.1 AND SECTION 8.2. INSPECTIONS SHALL BE PER RCSC SECTION <br />9.3 <br />SFRS WELDING REQUIREMNTS: ALL WELDING SHALL BE DONE WITH APPROPRIATE WELD PROCEDURES PREPARED <br />THE SEISMIC SUPPLEMENT, AWD D1.8, INCLUDING, BOTH SHOP FABRICATION AND FIELD ERECTION WELDING. <br />1.WELDING PROCEDURE SPECIFICATIONS (WPS): WELDING SHALL BE DONE WITH APPROPRIATE WELD <br />PROCEDURES PREPARED IN ACCORDANCE WITH AWS D1.1, AWS D1.8 CLAUSES 6.1. SUBMIT FOR REVIEW PER <br />AISC 341 SECTION <br />2.FILLER METAL: WELDS OF MEMBERS OF THE SFRS SHALL BE MADE WITH FILLER METAL CONFORM TO THE <br />REQUIREMENTS OF AISC 341 SECTION A3.4 AND AWS D1.8 CLAUSES 6.3, WHICH CAN PRODUCE WELDS THAT <br />HAVE MINIMUM CHARPY V-NOTCH TOUGHNESS OF 20 FOOT-POUNDS AT 0 DEGREES FAHRENHEIT. SUBMIT <br />EVIDENCE OF COMPLIANCE. <br />3.WELD (RUNOFF) TABS: REMOVE WELD (RUNOFF) TABS, UNLESS NOTED OTHERWISE, AND GRIND SURFACES PER <br />AWS D1.8 CLAUSES 6.11 UNLESS NOTED OTHERWISE. <br />4.CONTINUINTY PLATES AND STIFFENERS PLACED INTO THE WEBS OF ROLLED SHAPED SHALL BE DETAILED IN <br />ACCORDANCE WITH AWS D1.8 CLAUSES 4.1. <br />5.WELD ACCESS HOLES OF DEMAND CRITICAL WELDS SHALL EITHER BE PER AWS D1.8 SECTION 6.10.1.2. OR AS <br />OTHERWISE PERMITTED PER AISC 360 SECTION J1.6. <br />6.BACKING BARS: <br />a. BACKING IN GROOVE WELDED BUTT SPLICED OF COLUMNS NEED NOT BE REMOVED <br />b. BACKING IN GROOVE WELDS OF COLUMNS TO BASEPLATES SHALL BE REMOVED EXCEPT WHEN BACKING IS <br />PLACED AND REINFORCED PER THE REQUIREMENTS OF AISC 341 SECTION D2.6 <br />7.TACK WELDS: ALL TACK WELDS PART OF THE SFRS SHALL COMPLY WITH REQUIREMENTS OF AWS D1.8 SECTION <br />6.16. <br />8.DEMAND CRITICAL WELDS (DCW): WELDS DESIGNATED AS “DEMAND CRITICAL WELDS” OR “DCW” IN THE TAIL OF <br />WELD SYMBOLS ON DRAWINGS SHALL COMPLY WITH THE ADDITIONAL REQUIREMENTS OF SECTIONS A3.4B AND <br />I2.3 IN AISC 341 AND SHALL BE MADE WITH FILLER METALS CAPABLE OF PROVIDING A MINIMUM CHARPY V-NOTCH <br />TOUGHNESS OF 20 FT-LB AT 0 DEGREES FAHRENHEIT AND 40 FT-LB AT 70 DEGREES FHARENHEIT AS <br />DETERMINED BY THE APPROPRIATE AWS CLASSIFICATION TEST METHOD OR MANUFACTURER CERTIFICATION. <br />UNLESS OTHERWISE NOTES, THE FOLLOWING NOTED, THE FOLLOWING WELDS IN THE SFRS SHALL BE <br />CONSIDERED “DEMAND CRITICAL”: <br />9. COMPLETE-JOINT-PENETRATION (CJP) GROOVE WELDS OF: <br />a. COLUMN SPLICES <br />b. COLUMN-TO-BASEPLATE <br />c. BEAM FLANGE-TO-COLUMN FLANGE, UNLESS OTHERWISE NOTED IN AISC 358 <br />d. BEAM WEB-TO-COLUMN FLANGE, UNLESS OTHERWISE NOTED IN AISC 358 <br />STEEL STAIRS <br />REFERENCE STANDARDS: CONFORM TO: <br />1. CBC CHAPTER 10 - “MEANS OF EGRESS”, CBC TABLE 1607.1 <br />2. NAAMM - “METALS STAIRS MANUAL” <br />3. ANSI/AISC 360-10 - “SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS” <br />4. AISI 2007 - “NORTH AMERICA SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL STRUCTURAL MEMBERS” <br />5. AWS D1.1-0 “STRUCTURAL WELDING CODE- STEEL”, <br />6. AWS D1.3-08 “STRUCTURAL WELDING CODE- SHEET STEEL.” <br />SUBMITTALS: STEEL STAIRS ARE TO BE PREPARED BY A SSE. REFERENCE DEFINITIONS AND DEFERRED SUBMITTALS <br />ABOVE. SUBMIT STRUCTURAL CALCULATIONS AND SHOP DRAWINGS (COMPONENT DESIGN DRAWINGS) STAMPED BY <br />A PROFESSIONAL CIVIL PF STRUCTURAL ENGINEER REGISTERED OM THE STATE OF CALIFORNIA. <br />MATERIALS: <br />STRUCTURAL WF SHAPES…………………............................ASTM A992 - GR50 <br />STEEL CHANNELS, ANGLES, AND PLATES & BAR...............ASTM A36 <br />SHEET STEEL (GALVANIZED)………………...........................ASTM A446 <br />STEEL PIPE RAIL……………………………..............................ASTM A53, GRADE B <br />STEEL TUBING ……………………………................................ASTM A500, GRADE B <br />STEEL ROD…………………………………...............................ASTM A36 OR A307 <br />STEEL DECK……………………………….................................1- ½” COMPOSITE FLOOR DECK <br />BOLTS……………………………………….................................ASTM A325N <br />WELDS, STRUCTURAL STEEL………………….AWS D1.1 <br />WELDS, SHEET STEEL………………………......AWS D1.3 <br />WELDED HEADED STUDS (WHS)………….......ASTM A108, AWS D1.1 <br />HEADED CONCRETE ANCHORS (HCA)……….ASTM A108, AWS D1.1 <br />STRUCTURAL REQUIREMENTS: <br />1.SCOPE: INCLUDE TREADS, RISERS, STINGERS, LANDINGS, RAILINGS AND ALL CONNECTIONS INCLUDING <br />CONNECTIONS TO THE PRIMARY STRUCTURE UNLESS NOTED OTHERWISE. ALL INSERTS REQUIRED FOR <br />ATTACHMENT TO THE PRIMARY STRUCTURE SHALL BE DESIGNED AND PROVIDED BY THE STAIR SUPPLIER. <br />2.LOADS: STAIR TREADS SHALL BE DESIGNED FOR 100 PSF LIVE LOAD OR 300LB. CONCENTRATED LOAD PLACED <br />TO PRODUCE MAXIMUM STRESS, WHICHEVER CONTROLS. STRINGERS AND LANDINGS SHALL BE DESIGNED FOR <br />100 PSF LIVE LOAD. LIVE LOAD DEFLECTION SHALL NOT EXCEED 1/360 OF THE SPAN. THE STAIR ASSEMBLY AND <br />ATTACHMENT TO THE MAIN STRUCTURE SHALL BE DESIGNED FOR LATERAL LOADS PER CBC CHAPTER 16 <br />3.RAILINGS: THE COMPLETED HANDRAIL, GUARDRAIL, AND SUPPORTING STRUCTURE AND THEIR CONNECTIONS <br />SHALL BE DESIGNED TO RESIST LOADS AS SPECIFIED IN THE CBC SECTION 1607.8. <br />4.ARCHITECTURAL REQUIREMENTS: CONFORM TO SHAPE AND CONFIGURATION SHOWN ON THE ARCHITECTURAL <br />DRAWINGS. CONSULT THE PROJECT SPECIFICATIONS FOR ADDITIONAL INFORMATION. ALL STEEL SHALL BE <br />PAINTED PER PROJECT SPECIFICATIONS WITH ONE COAT OF STANDARD SHOP PRIMER UNLESS NOTED <br />OTHERWISE ON THE DRAWINGS OR IN THE SPECIFICATIONS <br />5.CONCRETE FILL: CONFORM TO NOTES, THIS SHEET FOR CAST-IN-PLACE CONCRETE AND CONCRETE <br />REINFORCEMENT. PROVIDE MINIMUM 3000 PSI CONCRETE AND WWF 6X6-W1.4 OR FIBER MESH UNLESS NOTED <br />ON THE DRAWINGS. <br />STRUCTURAL (S), (W) & (HP) SHAPES <br />CHANNEL (C) & ANGLE (L) SHAPES <br />STRUCTURAL PLATE (PL) <br />HIGH STRENGTH PLATE (GR 50 PL) <br />HOLLOW STRUCTURAL SECTION-SQUARE/RECT(HSS) <br />STRUCTURAL PIPE (PIPE) 12” DIA. AND LESS <br />HOLLOW STRUCTURAL SECTION-ROUND (HSS) <br />HEAVY HEX NUTS <br />WASHERS (HARDENED FLAT OR BEVELED) <br />ANCHOR RODS (ANCHOR BOLTS, TYPICAL) <br />MILD THREADED RODS <br />HIGH STRENGTH THREADED RODS <br />ASTM A992 FY=50 KSI <br />HIGH STRENGTH THREADED RODS <br />WELDED HEADED (SHEAR) STUD ANCHORS <br />WELDED HEADED STUD (WHS) ANCHORS <br />DOWEL BAR ANCHORS (DBA) <br />ASTM A36, FY=36 KSI <br />ASTM A36 FY=36 KSI <br />ASTM A36 FY=36 KSI <br />ASTM A572 FY=50 KSI <br />ASTM A500 GRADE B FY= 46 KSI <br />ASTM A53 GRADE B FY= 35 KSI <br />ASTM A325/F1852 TYPE 1 OR 3, PLAIN OR GALVANZED (AS <br />REQ'D) <br />ASTM A563 GRADE AND FINISH PER RCS TABLE 2.1 <br />ASTM F436 GRADE AND FINISH PER RCSC TABLE 2.1 <br />ASTM F1554 GR.36 <br />ASTM F1554 GR.55 (WELD ABLE) PER SUPPLEMENT S1 <br />ASTM A36 FY= 36 KSI <br />ASTM A36 FY= 50 KSI <br />ASTM A193 GRADE B7 FY = 100 KSI <br />ASTM A108-NELSON/TRW S3L <br />HIGH STRENGTH HEAVY HEX STRUCTURAL BOLTS <br />ASTM A500 GRADE B FY= 42 KSI <br />ANCHOR RODS (HIGH STRENGTH) <br />ASTM A496- NELSON/TRW D2L FY = 70 KSI <br />ASTM A108 NELSON /TRW H4L <br />STRUCTURAL STEEL MATERIALS <br />WIDE FLANGE (WF), TEE (WT) SHAPES <br />S-0.12 <br />ST <br />R <br />U <br />C <br />T <br />U <br />R <br />A <br />L <br /> <br />N <br />O <br />T <br />E <br />S