CITY OF SANTA ANA <br />SPECIFICATIONS <br />PROJECT NO.: XX-XXXX <br />PROJECT TITLE <br /> <br />88 <br />If a conduit is bored or jacked across existing sewer mains, the contractor shall conform <br />to the following requirements: <br />1. Pothole to determine location and depth of the sewer mains and laterals. <br />2. Visual confirmation by City Inspector shall be done during the boring/jacking of <br />the conduit across the sewer mains for any damages prior to back filling the <br />pothole. <br />3. If visual confirmation is not done, the contractor shall perform Video Inspection <br />of Sewer Mains and Laterals per the following specifications. <br />a. Video Inspection of Sewer Mains and Laterals <br />The contractor shall use CCTV equipment to verify that City sanitary sewer <br />mains have not been impacted. This includes all mains that appear on the plan <br />of construction drawings as possible points of interference, regardless of the <br />relative elevation of the sewer and what is believed to be the elevation of the <br />newly constructed facility. <br />The contractor shall use equipment specially designed and constructed for <br />sewer inspection and televising. The camera must have light sources of <br />suitable illumination output to provide a clear picture of the entire periphery <br />of pipe. The camera must be able to be rotated to a position that will assure <br />that the total periphery of the sewer is in focus at all times, regardless of the <br />diameter of the pipe being inspected. The camera, transport system, and other <br />components of the video system shall be capable of producing a picture <br />adequate for the purposes of the inspection as stated herein. Video runs <br />showing condensation or submersion of the lens, poor or out-of-focus images, <br />poor audio, or otherwise poor image quality shall be cause for rejection and <br />may necessitate re-televising at the consultant’s expense if the City determines <br />the video run is not of acceptable quality. <br />A cable footage counter, accurate to within one (1) foot in 1000 feet, shall be <br />used and shall be indicated on the monitor and recorded on the video. The <br />date of inspection, continuous forward and reverse readout of camera distance <br />from referenced access hole, the City supplied upstream and downstream <br />manhole identification number with an arrow indicating the direction of <br />flow, the size of the pipe, the name of the street, the time of day and the <br />project or location name as supplied by the City shall be displayed <br />continuously on the monitor and recorded on the video. The use of non- <br />standard or incorrectly numbered manholes by the contractor on the <br />video overlay is cause for rejection of the digital video and any costs <br />associated with re-videoing of the main that are necessitated by the <br />contractor’s failure to use designated naming conventions will be bor ne <br />entirely by the contractor. The footage relative to the center of the manhole <br />at the start of each run shall be set to accurately reflect a center of manhole <br />starting position of 0.00 feet regardless of where along the pipe and at what <br />footage the run begins. All video operations shall begin at a manhole adjacent <br />505 E Central Ave <br />#B11/6/2024