My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
505 E Central Ave #B - DEF 1 - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Central Ave
>
505 E Central Ave Unit# B
>
505 E Central Ave #B - DEF 1 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 5:01:47 AM
Creation date
2/24/2026 5:00:42 AM
Metadata
Fields
Template:
Plan
Permit Number
20181754
30146722
40138703
101117766
101124090
Full Address
505 E Central Ave Unit# B
Street Number
505
Street Direction
E
Street Name
Central
Street Suffix
Ave
Unit Number
B
Document Relationships
101117766 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
101124090 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
20181754 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
30146722 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
40138703 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
994
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CITY OF SANTA ANA <br />SPECIFICATIONS <br />PROJECT NO.: XX-XXXX <br />PROJECT TITLE <br /> <br />118 <br />4. Provide minimum cover of eighteen (18) inches for all control wiring. <br />5. Provide minimum cover of twenty-four (24) inches for all piping under paved <br />areas. Provide two (2) inch sand bedding and four (4) inch sand backfill over pipe <br />barrel in paved areas. <br />J. BACKFILLING <br />1. Compact backfill for trenching to a dry density equal to adjacent undisturbed soil <br />in planting areas and to 90 percent in paved areas. Conform to adjacent grades <br />without dips, sunken areas, humps or other irregularities. <br />2. In existing pavement areas backfill shall be one sack sand cement slurry per yard <br />of material. <br />3. Place initial backfill on all lines of a fine granular material; no foreign matter <br />larger than one-half (1/2) inch in size will be permitted. <br />4. Flooding of trenches will be permitted only with approval of the Engineer. <br />5. If settlement occurs and adjustments in pipe, valves, sprinkler heads, lawn or <br />planting, or other construction are necessary, the Contractor shall make all <br />required adjustments without cost to the Owner. <br />K. PIPING UNDER PEDESTRIAN AND VEHICULAR PAVEMENT <br />All piping under pedestrian and vehicular pavement shall be sleeved. Sleeve shall be <br />minimum 2.5 -times the diameter of the irrigation lines. Sleeves shall be of materials <br />and installation methods approved by the local governing body but as a minimum <br />shall be Schedule 80 PVC pipe. <br />L. TESTING <br />1. Test all pressure and non-pressure lines under hydrostatic pressure of 125 pounds <br />per square inch, and prove both watertight. <br />2. Sustain pressure in lines for not less than two (2) hours. If leaks develop, replace <br />joints and repeat test until entire system is proven watertight. <br />3. Tests shall be observed and approved by Engineer prior to backfill. <br />4. Upon completion of each phase of work, entire system will be tested and adjusted <br />to meet site requirements. <br />5. Tests shall be performed with automatic valves in place. <br />M. INSPECTION OF WORK <br />Installation and operations must be approved by the Engineer. <br />505 E Central Ave <br />#B11/6/2024
The URL can be used to link to this page
Your browser does not support the video tag.