My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
505 E Central Ave #B - DEF 1 - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Central Ave
>
505 E Central Ave Unit# B
>
505 E Central Ave #B - DEF 1 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 5:01:47 AM
Creation date
2/24/2026 5:00:42 AM
Metadata
Fields
Template:
Plan
Permit Number
20181754
30146722
40138703
101117766
101124090
Full Address
505 E Central Ave Unit# B
Street Number
505
Street Direction
E
Street Name
Central
Street Suffix
Ave
Unit Number
B
Document Relationships
101117766 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
101124090 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
20181754 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
30146722 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
40138703 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
994
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CITY OF SANTA ANA <br />SPECIFICATIONS <br />PROJECT NO.: XX-XXXX <br />PROJECT TITLE <br /> <br />193 <br />existing or connecting pipe and appurtenances that are exposed as a result of this pipe <br />installation shall also be wrapped with polyethylene sheeting. <br />All tapping sleeves must be a minimum of 24" from the nearest joint or service. <br />7.19 COMBINATION AIR VALVES (AS NEEDED) <br />This item is to be used on an “as needed” basis and only with the prior approval of the <br />Engineer. <br />This work shall consist of furnishing and installing air and vacuum release valve <br />assemblies per City of Santa Ana Standard Plan No. 1415A. All work shall be in <br />conformance with AWWA C512 and these Special Provisions. <br />Main line taps and copper pipe line runs for 1” air and vacuum release valves shall be <br />constructed per the applicable provisions pertaining to water services and fire lines of <br />these Special Provisions. <br />Air and vacuum release valves shall be field located by the Engineer or as noted on the <br />construction plans. <br />The exterior of the vented cover shall be installed with a City of Santa Ana logo decal. <br />7.20 VERTICAL OFFSET (AS NEEDED) <br />This item is to be used on an “as needed” basis and only with the prior approval of the <br />Engineer. <br />This work shall consist of furnishing and installing a vertical offset per City of Santa Ana <br />Standard Plan No. 1413B. All work shall conform to applicable AWWA standards as <br />necessary. <br />7.21 DISINFECTION AND FLUSHING PLAN <br />All disinfection and flushing tasks shall be completed per AWWA C651 and these <br />special provisions. <br />Prior to start of construction, the Contractor shall submit to the City for review and <br />approval a water line "Disinfection and Flushing Plan" prepared by a D3 or T3 Operator <br />Certified with California Department Health Services, or a Registered Civil Engineer <br />practicing in the field of water resources, indicating the following as a minimum: <br /> Phasing of disinfection and flushing <br /> Source of flushing water <br /> Type and configuration of connection required to introduce flushing water into <br />the propose water main <br /> Method of disposal of flushed water <br /> Total number and locations of sampling points <br />505 E Central Ave <br />#B11/6/2024
The URL can be used to link to this page
Your browser does not support the video tag.