Laserfiche WebLink
CITY OF SANTA ANA <br />SPECIFICATIONS <br />PROJECT NO.: XX-XXXX <br />PROJECT TITLE <br /> <br />207 <br />shall be rigid galvanized steel conduit with ground bushing properly grounded. All <br />stud outs shall be equipped with non-cemented approved PVC pipe caps. <br />B. BUSHINGS, LOCKNUTS, AND CONDUIT FITTINGS <br />Boxes, bushings, locknuts and similar devices shall be galvanized cast steel or cast <br />iron, malleable iron, or galvanized steel. Aluminum die case or pot metal fittings or <br />boxes are not approved. Conduit fiber lined bushings are required to be used with <br />locknuts at cabinets, switchboards, housing and pull boxes, etc. All conduit with <br />cable shall be sealed at each end. Grounding bushings shall be provided on <br />underground rigid conduits. <br />C. WIRE AND CABLE <br />Branch conduit wire shall be copper type THW-75 degrees or THHN/THWN in <br />conduit and light poles, as manufactured by General Electric, Paranite, General, <br />Circle, Cirro or Anaconda, 600 v. Ground wire shall be color coded for each let. <br />Neutral shall be white THW or THWN. Identify cable by circuit number in each pull <br />box by W.P. Tag. No. 6 and larger cable shall be THW-75 degrees stranded copper. <br />Approved manufacturers: General Electric, Paranite, Okonite, Anaconda, General. <br />Cable underground shall be color coded by phase. Stranded wire shall be used in <br />poles from pull boxes to fixtures. Provide manufactured cable grips in poles to <br />support cables. <br />D. PULL BOXES <br />Pull boxes shall be as specified on plans. <br />When precast concrete pull boxes are used, covers shall be cast iron, bolted down <br />with tamperproof screws, and marked “Electrical”. <br />E. TIME CONTROL CLOCKS <br />Time control clocks shall be 120v or 208v with 2 or 4 channels required on the <br />drawings and in these specifications. The clock shall be solid state digital type with <br />battery backup. Set clock for proper day, month and hour and set trip elements as <br />directed by the City. Clocks shall be Paragon #EC72ST or equal. Clocks shall be in <br />NEMA 1 housing. <br />F. SWITCHES AND RECEPTACLES <br />Receptacles shall be a 20A ground duplex in switchboard and mounted separate from <br />the panel front. Receptacle shall be equal to A-H Specification Grade #5262-1 with <br />stainless steel plate. <br />Receptacles for special housing and plates shall be as noted on drawings and shall be <br />A-H Safety Receptacle 6352-1. <br />505 E Central Ave <br />#B11/6/2024