My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
505 E Central Ave #B - DEF 1 - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Central Ave
>
505 E Central Ave Unit# B
>
505 E Central Ave #B - DEF 1 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 5:01:47 AM
Creation date
2/24/2026 5:00:42 AM
Metadata
Fields
Template:
Plan
Permit Number
20181754
30146722
40138703
101117766
101124090
Full Address
505 E Central Ave Unit# B
Street Number
505
Street Direction
E
Street Name
Central
Street Suffix
Ave
Unit Number
B
Document Relationships
101117766 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
101124090 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
20181754 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
30146722 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
40138703 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
994
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Delhi Community Center Library Renovation 9/29/2023 <br />Santa Ana, California <br /> <br /> <br /> 01 35 15 - 3 CALGreen Environmental Requirements <br />h. Indoor Air Quality: Comply with CALGreen requirements for outside air <br />delivery and carbon dioxide monitoring. <br />i. Environmental Comfort: Comply with CALGreen requirements for whole <br />acoustical control and interior sound control. <br />j. Outdoor Air Quality: Comply with CALGreen requirements for reduction of <br />greenhouse gases and ozone depletion. <br />5. Residential Projects Environmental Quality: <br />a. Fireplaces: Comply with requirement that gas fireplaces (if any) shall be <br />direct-vent sealed-combustion type and woodstoves or pellet stoves (if any) <br />comply with U.S. EPA Phase II emissions limits. <br />b. Mechanical Equipment Pollution Control: Cover duct and related air <br />distribution component openings to prevent dust and debris accumulation. <br />c. Finish Material Pollution Control: Comply with CALGreen requirements for <br />volatile organic compound (VOC) emissions including but not necessarily <br />limited to following (as applicable): <br />1) Adhesives, sealants and caulks. <br />2) Paints and coatings. <br />3) Carpet systems including carpet, carpet cushion, and adhesives. <br />4) Resilient flooring systems. <br />5) Composite wood products formaldehyde limitations. <br />d. Interior Moisture Control: Comply with CALGreen requirements for vapor <br />retarder at concrete slab foundations and capillary break (aggregate base). <br />e. Building Material Moisture Content: Do not use water damaged building <br />materials, remove and place wet and high moisture content insulation, and <br />do not enclose wall or floor framing when moisture content exceeds 19%. <br />f. Indoor Air Quality: Provide humidistat-controlled bathroom exhaust fans with <br />Energy Star compliance, ducted to terminate outside building. <br />g. Environmental Comfort: Comply with CALGreen requirements for whole <br />house exhaust fan louvers to be insulated or have covers which close when <br />fan is off, and with heating and air-conditioning system design requirements. <br />C. Planning and Design: Construction team shall coordinate with Design Team <br />regarding Project Planning and Design methods related to CALGreen requirements <br />related to Project design and shall comply with requirements related to construction. <br />1.3 QUALITY ASSURANCE <br />A. Project Management and Coordination: Contractor to identify one person on <br />Contractor’s staff to be responsible for CALGreen issues compliance and <br />coordination. <br />505 E Central Ave <br />#B11/6/2024
The URL can be used to link to this page
Your browser does not support the video tag.