Laserfiche WebLink
ANNOTATIONS <br />A-1&3&5 <br />A-1,3 <br />TELEPHONE OUTLET BOX, CEILING MOUNTED <br />COMBINATION TELEPHONE AND DATA OUTLET BOX FLUSH MOUNTED IN CEILING <br />PB <br />a,bC <br />B <br />A <br />UTILITY COMPANY METER. PROVIDE "CT's" AND "PT's" AS REQUIRED, REFER TO SINGLE LINE <br />DIAGRAM. <br />NON-FUSED DISCONNECT SWITCH, HP RATED AND WEATHERPROOF AS REQUIRED. PROVIDE <br />FINAL CONNECTION TO UNIT EQUIPMENT. SEE MOTORIZED EQUIPMENT SCHEDULE FOR <br />DISCONNECT SIZES. <br />FUSED DISCONNECT SWITCH, HP RATED, OR COMBINATION MOTOR STARTER/DISCONNECT <br />SWITCH WITH FUSES PER EQUIPMENT MANUFACTURER AND WEATHERPROOF AS REQUIRED. <br />PROVIDE FINAL CONNECTION TO UNIT EQUIPMENT. SEE MOTORIZED EQUIPMENT SCHEDULE <br />FOR DISCONNECT AND STARTER SIZES. <br />DUPLEX RECEPTACLE, WALL MOUNTED +18" AFF OR AS NOTED. <br />DOUBLE DUPLEX RECEPTACLE, WALL MOUNTED +18" AFF OR AS NOTED. <br />DUPLEX, GFCI RECEPTACLE, WALL MOUNTED +18" AFF OR AS NOTED. WP INDICATES <br />WEATHERPROOF. <br />DOUBLE DUPLEX, GFCI RECEPTACLE, WALL MOUNTED. WP INDICATES WEATHERPROOF. <br />DUPLEX RECEPTACLE, ONE HALF SWITCHED, WALL MOUNTED +18" AFF OR AS NOTED. <br />DUPLEX, ISOLATED GROUND RECEPTACLE, WALL MOUNTED +18" AFF OR AS NOTED. <br />SIMPLEX RECEPTACLE, WALL MOUNTED +18" AFF OR AS NOTED. <br />JUNCTION BOX, WALL MOUNTED AT +18" A.F.F. OR AS NOTED. 4S/DP MINIMUM OR AS <br />REQUIRED BY N.E.C.. <br />JUNCTION BOX, MOUNTED IN ACCESSIBLE CEILING FOR APPLICATION DENOTED ON PLAN. <br />4S/DP MINIMUM OR AS REQUIRED BY N.E.C.. <br />JUNCTION BOX, WALL MOUNTED AT 6" ABOVE COUNTER OR SPLASH. 4S/DP MINIMUM OR AS <br />REQUIRED BY N.E.C.. <br />THERMOSTAT OUTLET BOX, PROVIDE 1/2"C.O. TO RESPECTIVE MECHANICAL UNIT. <br />EXHAUST FAN, OR MOTOR LOAD. REFER TO MECHANICAL, PLUMBING OR KITCHEN DRAWINGS <br />FOR SPECIFIC LOAD REQUIREMENTS OR AS NOTED. <br />TRANSFORMER, REFER TO SINGLE LINE DIAGRAM. <br />DENOTES TWO SINGLE PHASE CIRCUITS WITH SEPARATE NEUTRAL WIRE. 3/4" <br />CONDUIT- 4#12 + 1/#12 GRD <br />REFER TO DERATING TABLE. <br />CONCEALED CONDUIT OR BRANCH CIRCUIT UNLESS OTHERWISE NOTED. 3/4" <br />CONDUIT MINIMUM, 2 #12 +1#12 GRD CONDUCTORS MINIMUM. <br />CONDUIT OR BRANCH CIRCUIT CONCEALED BELOW GRADE, 3/4" CONDUIT MINIMUM <br />WITH (2) 12 AWG CONDUCTORS MINIMUM AND A CODE SIZED EQUIPMENT GROUND. <br />CIRCUIT BREAKER: "A" REPRESENTS CIRCUIT BREAKER AMPERE RATING, "B" REPRESENTS <br />NUMBER OF POLES AND "C" REPRESENTS MISCELLANEOUS BREAKER FEATURES. <br />FUSIBLE SWITCH: "A" REPRESENTS SWITCH / FRAME AMPERE RATING, "B" <br />REPRESENTS THE FUSE AMPERE RATING, "C" INDICATES NUMBER OF POLES AND "D" <br />REPRESENTS MISCELLANEOUS FUSE / SWITCH FEATURES. <br />SINGLE POLE SWITCHES, WALL MOUNTED. SUBSCRIPTS AT SYMBOL INDICATE THE <br />FOLLOWING: <br />NOTE: ALL WALL SWITCHES CONTROLLING EMERGENCY CIRCUITS SHALL BE <br />ENGRAVED WITH "EMERGENCY". <br />EMERGENCY POWER OFF STATION, WALL MOUNTED PER EPO SYSTEM DETAIL. <br />PULLBOX, SIZED PER N.E.C. OR AS NOTED. <br />GROUND CONNECTION, SIZE AS INDICATED AND REQUIRED. <br />CONDUIT STUB OUT, CAP, MARK AND RECORD ON AS-BUILT DRAWINGS <br />CONDUIT CONTINUATION. <br />CONDUIT STUB DOWN <br />CONDUIT STUB UP <br />TV OUTLET, WALL MOUNTED. STUB A 3/4"C.O. UP 6" ABOVE THE ACCESSIBLE CEILING AND <br />PROVIDE BUSHING. <br />MECHANICAL EQUIPMENT CALLOUT, "AC" INDICATES UNIT TYPE AND "2" INDICATES UNIT <br />NUMBER. REFER TO MECHANICAL DRAWINGS FOR EXACT LOCATION AND ELECTRICAL <br />REQUIREMENTS. <br />DETAIL CALLOUT, "3" INDICATES DETAIL NUMBER "E-1" INDICATES SHEET NUMBER. <br />PLAN NOTE REFERENCE, REFER TO NOTES ON SHEET, OR AS DIRECTED. <br />REVISION REFERENCE. <br />WYE CONFIGURATION DELTA CONFIGURATION GROUND <br />TELEPHONE OUTLET BOX, WALL MOUNTED. STUB A 1" C.O. UP 6" ABOVE THE ACCESSIBLE <br />CEILING AND PROVIDE A BUSHING. 4S/DP MINIMUM WITH SINGLE GANG RING. <br />DATA OUTLET BOX, WALL MOUNTED. STUB A 1" C.O. UP 6" ABOVE THE ACCESSIBLE <br />CEILING AND PROVIDE A BUSHING. 4S/DP MINIMUM WITH SINGLE GANG RING. <br />COMBINATION TELEPHONE AND DATA OUTLET BOX, WALL MOUNTED. STUB A 1" C.O. <br />UP 6" ABOVE THE ACCESSIBLE CEILING AND PROVIDE A BUSHING. 4S/DP MINIMUM <br />WITH SINGLE GANG RING. <br />FLUSH MOUNTED, LOCKABLE TERMINAL CABINET WITH TERMINAL STRIPS AS REQUIRED. <br />SURFACE MOUNTED, LOCKABLE TERMINAL CABINET WITH TERMINAL STRIPS AS REQUIRED. <br />TELEPHONE TERMINAL BACKBOARD SIZED AS NOTED, REFER TO SYSTEM GROUND DETAIL. <br />J <br />J <br />J <br />T <br />T <br />TV <br />2 <br />4 <br />3 <br />E-1 <br />AC <br />2 <br />A <br />S <br />M <br />F <br />ELECTRICAL SYMBOL LISTS <br />A-1 <br />DENOTES 120V OR 277V CIRCUIT WITH NEUTRAL WIRE. 3/4" CONDUIT- 2/#12 + 1/#12 <br />GRD MIN. <br />DENOTES THREE PHASE CIRCUIT NO NEUTRAL WIRE. 3/4" CONDUIT- 3#12 + 1/#12 GRD <br />A-1&3 <br />DENOTES SINGLE PHASE CIRCUIT NO NEUTRAL WIRE. 3/4" CONDUIT- 2#12 + 1/#12 GRD <br />DATA OUTLET BOX, CEILING MOUNTED <br />TELEPHONE OUTLET BOX, FLUSH MOUNTED IN FLOOR <br />COMBINATION TELEPHONE AND DATA OUTLET BOX FLUSH MOUNTED IN FLOOR <br />DATA OUTLET BOX, FLUSH MOUNTED IN FLOOR <br />SYMBOL INDICATES MOUNTED FLUSH ON FLOOR <br />SYMBOL INDICATES CEILING MOUNTED <br />IG <br />ASTRONOMICAL TIME CLOCK.TC <br />EXIT SIGN. ARROW AND SHADE DENOTES DIRECTION. REFER TO EMERGENCY SYSTEM <br />FOR CIRCUITING. <br />POLE LIGHT. REFER TO STRUCTURAL PLANS FOR POLE BASE REQUIREMENT AND <br />SPECIFICATION. <br />EMERGENCY BUG EYE. PROVIDE MINIMUM 90 MIN BACK-UP BATTERY <br />SURFACE DOWNLIGHT. HATCH INDICATES ON EMERGENCY. PROVIDE 90 MIN BATTERY <br />PACK OR EMERGENCY CIRCUIT CONNECTION. REFER TO EMERGENCY SYSTEM FOR <br />EXACT REQUIREMENT. <br />NORMAL POWER SURFACE MOUNTED STRIP LIGHT <br />RECESSED DOWNLIGHT. HATCH INDICATES ON EMERGENCY. PROVIDE 90 MIN <br />BATTERY PACK OR EMERGENCY CIRCUIT CONNECTION. REFER TO EMERGENCY <br />SYSTEM FOR EXACT REQUIREMENT. <br />1X4 LED STRIP LIGHT. DOUBLE LINE DENOTES RECESSED MOUNTED. <br />HATCH DENOTES EMERGENCY POWER. PROVIDE 90 MIN BATTERY PACK OR ON <br />EMERGENCY CIRCUIT CONNECTION. REFER TO EMERGENCY SYSTEM FOR EXACT <br />REQUIREMENT. <br />LV CAMERA. PROVIDE DEDICATED CAT 6 CABLE PER CAMERA. MAXIMUM CABLE <br />LENGTH SHALL BE 225'-0" <br />SD SMOKE DETECTOR. PROVIDE LOCK-ON DEVICE IN PANEL BREAKER. <br />DEDICATED 208/240V OUTLET SINGLE PHASE 2 POLE. VERIFY NEUTRAL WIRE REQUIREMENT <br />WITH EQUIPMENT SUBMITTAL <br />DENOTES EQUIPMENT NUMBER. REFER TO EQUIPMENT SCHEDULE FOR DETAILS <br />MSB SWITCHBOARD/DISTRIBUTION BOARD TAG, "MSB" INDICATES EQUIPMENT DESIGNATION. <br />PANEL TAG, "A" INDICATES PANELBOARD OR EQUIPMENT DESIGNATION. <br />1 <br />WALL MOUNTED OCCUPANCY SENSOR LOWER CASE LETTERS INDICATES SWITCH LEG <br />CEILING MOUNTED OCCUPANCY SENSOR LOWER CASE LETTERS INDICATES SWITCH LEG <br />PCI CEILING MOUNTED DAYLITE PHOTOCELL CONTROL. <br />4S/DP 4" SQUARE BY 2-1/8" DEEP BOX <br />ADA AMERICAN WITH DISABILITIES ACT <br />A.F.F. ABOVE FINISH FLOOR <br />A.F.G. ABOVE FINISH GRADE <br />AWG AMERICAN WIRE GAUGE <br />AMP AMPERE <br />A.I.C.AMPERES INTERRUPTING CAPACITY <br />AF/AT AMP FRAME, AMP TRIP <br />AHJ AUTHORITY HAVING JURISDICTION <br />AS/AF AMPERE SWITCH, AMPERE FUSE <br />ATS AUTOMATIC TRANSFER SWITCH <br />AVG AVERAGE <br />BR BRANCH <br />BLDG BUILDING <br />CBC CALIFORNIA BUILDING CODE <br />CEC CALIFORNIA ELECTRICAL CODE <br />CIRC CIRCUIT <br />CKT. CB CIRCUIT BREAKER <br />CSFD COMBINATION SMOKE FIRE DAMPER <br />C CONDUIT <br />C.O. CONDUIT ONLY, COMPLETE WITH PULLSTRING <br />CONN CONNECTED <br />CT CURRENT TRANSFORMER <br />(D)EXISTING DEVICE TO BE DEMOLISHED. <br />DIA DIAMETER <br />DISC DISCONNECT <br />DIST DISTRIBUTION <br />E.C.ELECTRICAL CONTRACTOR <br />EMS ENERGY MANAGEMENT CONTROL SYSTEM <br />EMT ELECTRICAL METALLIC TUBING <br />ENT ELECTRICAL NON-METALLIC TUBING <br />EWC ELECTRIC WATER COOLER <br />EPO EMERGENCY POWER OFF <br />EOL END OF LINE CIRCUIT TERMINATOR <br />EF EXHAUST FAN <br />E, (E) EXISTING DEVICE TO REMAIN <br />EP EXPLOSION PROOF <br />(ER)EXISTING DEVICE TO BE RELOCATED <br />FT or 'FEET <br />FA FIRE ALARM <br />FLA FULL LOAD AMPS <br />GRD GROUND <br />GFCI GROUND FAULT CIRCUIT INTERRUPTER <br />GFP GROUND FAULT PROTECTION <br />GEC GROUNDING ELECTRODE CONDUCTOR <br />HACR HEATING AIR CONDITIONING REFRIGERATION <br />HOA HAND-OFF-AUTO <br />HVAC HEATING, VENTILATING AND AIR CONDITIONING <br />H.,W.,D.,L.HEIGHT, WIDTH, DEPTH, LENGTH <br />HP HORSEPOWER <br />HPS HIGH PRESSURE SODIUM <br />IN.or ''INCHES <br />I/G ISOLATED GROUND <br />IBC INTERNATIONAL BUILDING CODE <br />JBOX JUNCTION BOX <br />K DEGREE KELVIN <br />KCMIL THOUSAND CIRCULAR MILS <br />KVA KILOVOLT AMPERES <br />KW KILOWATT <br />KWH KILOWATT HOUR <br />LCL LONG CONTINUOUS LOAD <br />L.F LINEAR FEET <br />LTG LIGHTING <br />MAX.MAXIMUM <br />MCB MAIN CIRCUIT BREAKER <br />MLO MAIN LUGS ONLY <br />MCB MECHANICAL CONTRACTOR <br />M METER <br />M/M METER MAIN <br />MIN.MINIMUM <br />MCA MINIMUM CIRCUIT AMPS <br />MCC MOTOR CONTROL CENTER <br />MCM THOUSAND CIRCULAR MILS <br />MCP MOTOR CIRCUIT PROTECTOR <br />MFR MANUFACTURER <br />MTD MOUNTED <br />MW MICROWAVE <br />NATS NON AUTOMATIC DISCONNECT <br />NEC NATIONAL ELECTRICAL CODE <br />NEMA NATIONAL ELECTRICAL MANUFACTURERS' <br />ASSOCIATION <br />NC NORMALLY CLOSED <br />NO NORMALLY OPENED <br />NF NON-FUSED <br />NIC NOT IN CONTRACT <br />N.T.S.NOT TO SCALE <br />NL NIGHT LIGHT <br />NO.or #NUMBER <br />OFCI OWNER FURNISHED, CONTRACTOR <br />INSTALLED <br />%Z PERCENT IMPEDANCE <br />PH.or ø PHASE <br />PC PHOTOCELL <br />P.C.A PLUMBING CONTRACTOR <br />P POLE <br />PVC POLY VINYL CHLORIDE <br />PDU POWER DISTRIBUTION UNIT <br />PT POTENTIAL TRANSFORMER <br />PA PUBLIC ADDRESS <br />(R)DENOTES RELOCATED DEVICE LOCATION. <br />REC, RECEPT RECEPTACLE <br />REF REFRIGERATOR <br />RGS RIGID GALVANIZED STEEL <br />RMS ROOT MEAN SQUARE <br />SCC SHORT CIRCUIT CURRENT <br />SCS STRUCTURED CABLING SYSTEM <br />SFD SMOKE FIRE DAMPER <br />TC TIMECLOCK <br />TEL/DATA TELEPHONE AND DATA <br />TV TELEVISION <br />T.V..S.TRANSIENT VOLTAGE SURGE <br />SUPPRESSION <br />TYP TYPICAL <br />TTB TELEPHONE TERMINAL BOARD <br />U.G.P.S.UNDERGROUND PULL SECTION <br />U.O.N.UNLESS OTHERWISE NOTED <br />U.P.S.UNINTERRUPTABLE POWER SYSTEM <br />VAV VARIABLE AIR VOLUME <br />V VOLTS <br />VA VOLT AMPERES <br />VD VOLTAGE DROP <br />VL VERIFY EXACT LOCATION IN <br />FIELD/OWNER/ARCHITECT AND OTHER <br />TRADE <br />WP WEATHERPROOF <br />W WIRE <br />XFMR TRANSFORMER <br />ABBREVIATIONS BRANCH CIRCUIT SYMBOLS <br />C <br />B <br />A <br />D <br />SHUNT= PROVIDE SHUNT TRIP MECHANISM <br />HACR= PROVIDE HACR-RATED BREAKER <br />GFP= GROUND FAULT PROTECTION <br />CLCB= CURRENT LIMITING CIRCUIT BREAKER <br />SS= PROVIDE SOLID STATE CIRCUIT BREAKER <br />LO= PROVIDE PERMANENT LOCK-OPEN (OFF) HARDWARE <br />LC= PROVIDE PERMANENT LOCK-CLOSED (ON) HARDWARE <br />SHUNT= PROVIDE SHUNT TRIP MECHANISM <br />GFP= GROUND FAULT PROTECTION <br />CLF= CURRENT LIMITING FUSE <br />D - DIMMER <br />LV - LOW VOLTAGE <br />VC - VACANCY SENSOR <br />M - MOTOR RATED <br />OS - OCCUPANCY SENSOR <br />K - KEY OPERATED <br />4 - FOUR WAY <br />3 - THREE WAY <br />2 - DOUBLE POLE <br />a,b. - DENOTES SWITCH LEG. <br />LIGHTING <br />TELEPHONE/DATA <br />POWER <br />2X4 LED LIGHT. <br />DOUBLE LINE DENOTES RECESSED MOUNTED. <br />HATCH DENOTES EMERGENCY POWER. PROVIDE 90 MIN BATTERY PACK OR ON <br />EMERGENCY CIRCUIT CONNECTION. REFER TO EMERGENCY SYSTEM FOR EXACT <br />REQUIREMENT. <br />Scale <br />Date <br />Drawn By <br />Checked By <br />Project Number <br />14 <br />3 <br />0 <br /> <br />E <br /> <br />E <br />D <br />I <br />N <br />G <br />E <br />R <br /> <br />A <br />V <br />E <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />NOVUM <br />A R C H I T E C T U R E, Inc <br />www.novumarchitecture.com <br />OFFICES: SOUTH BAY / ORANGE COUNTY <br />116 S CATALINA AVE. STE. 122, <br />REDONDO BEACH, CA 90277 <br />TEL: 310-383-1827 / 310-709-4476 <br />N <br />AS SHOWN <br />TO <br />M <br />' <br />S <br /> <br />J <br />R <br />CAD <br />Author <br />9-1-2023 <br />tom's2023 <br />Mr <br />. <br /> <br />S <br />p <br />i <br />r <br />o <br />s <br /> <br />P <br />o <br />l <br />i <br />t <br />i <br />s <br />No.Description Date <br />1 PC Comments 08/08/2024 <br />2 HlthDep.Corr.2 09/03/2024 <br />SYMBOLS LIST & <br />ABBREVIATIONS <br />E-102 <br />1430 E Edinger Ave <br />3/27/2025