Laserfiche WebLink
. <br />. <br />. <br />. <br />CAST IRONSINKSBROOKFIELDK-5942-5 <br />DATUM <br />. <br />. <br />. <br />. <br />. <br />. <br />. <br />. <br />. <br />. <br />DATUMEAST <br />3414 S TIMBER ST <br />MAIN HOUSE 2,171 SQFT <br />(N) 1-HR FIRE RATED WALL <br />. <br />VENT HOOD <br />RANGE <br />ATTICACCESS <br />A. REINFORCEMENT FOR GRAB BARS. [R327.1.1] AT LEAST ONE BATHROOM ON THE ENTRY LEVEL SHALL <br />BE PROVIDED WITH REINFORCEMENT INSTALLED IN ACCORDANCE WITH THIS SECTION. WHERE THERE <br />IS NO BATHROOM ON THE ENTRY LEVEL, AT LEAST ONE BATHROOM ON THE 2ND OR 3RD FLOOR OF THE <br />DWELLING SHALL COMPLY WITH THIS SECTION. <br />1. REINFORCEMENT SHALL BE SOLID LUMBER OR OTHER CONSTRUCTION MATERIALS APPROVED <br />BY THE ENFORCING AGENCY. <br />2. REINFORCEMENT SHALL NOT BE LESS THAN 2 BY 8 INCH NOMINAL LUMBER (1-1/2” X 7-1/4” <br />ACTUAL DIMENSION) OR OTHER CONSTRUCTION MATERIAL PROVIDING EQUAL HEIGHT AND LOAD <br />CAPACITY. REINFORCEMENT SHALL BE LOCATED BETWEEN 32” AND 39-1/4” ABOVE THE FINISHED <br />FLOOR, FLUSH WITH THE WALL FRAMING. <br />3. WATER CLOSET REINFORCEMENT SHALL BE INSTALLED ON BOTH SIDE WALLS OF THE FIXTURE, <br />OR ONE SIDE WALL AND THE BACK WALL. <br />4. SHOWER REINFORCEMENT SHALL BE CONTINUOUS WHERE WALL FRAMING IS PROVIDED. <br />5. BATHTUB AND COMBINATION BATHTUB/SHOWER REINFORCEMENT SHALL BE CONTINUOUS ON <br />EACH END OF THE BATHTUB AND THE BACK WALL. ADDITIONALLY, BACK WALL REINFORCEMENT <br />FOR A LOWER GRAB BAR SHALL BE PROVIDED WITH THE BOTTOM EDGE LOCATED NO MORE THAN <br />6” ABOVE THE BATHTUB RIM. <br />6. WHERE THE WATER CLOSET IS NOT PLACED ADJACENT TO A SIDE WALL CAPABLE OF <br />ACCOMMODATING A GRAB BAR, THE BATHROOM SHALL HAVE PROVISIONS FOR INSTALLATION OF <br />FLOOR-MOUNTED, FOLDAWAY OR SIMILAR ALTERNATE GRAB BAR REINFORCEMENTS APPROVED <br />BY THE ENFORCING AGENCY. <br />B. DOCUMENTATION FOR GRAB BAR REINFORCEMENT. [R327.1.1.1] INFORMATION AND/OR DRAWINGS <br />IDENTIFYING THE LOCATION OF GRAB BAR REINFORCEMENT SHALL BE PLACED IN THE OPERATION & <br />MAINTENANCE MANUAL IN ACCORDANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS CODE, <br />CH. 4, DIVISION 4.4. <br />C. ELECTRICAL RECEPTACLE OUTLET, SWITCH & CONTROL HEIGHTS. [R327.1.2] ELECTRICAL <br />RECEPTACLE OUTLETS, SWITCHES AND CONTROLS (INCLUDING CONTROLS FOR HEATING, VENTILATION <br />AND AIR CONDITIONING) INTENDED TO BE USED BY OCCUPANTS SHALL BE LOCATED NO MORE THAN <br />48” MEASURED FROM THE TOP OF THE OUTLET BOX AND NOT LESS THAN 15” MEASURED FROM THE <br />BOTTOM OF THE OUTLET BOX ABOVE THE FINISH FLOOR. <br />D. INTERIOR DOORS. [R327.1.3] EFFECTIVE JULY 1, 2024, AT LEAST ONE BATHROOM AND ONE BEDROOM <br />ON THE ENTRY LEVEL SHALL PROVIDE A DOORWAY WITH A NET CLEAR OPENING OF NOT LESS THAN <br />32”, MEASURED WITH THE DOOR POSITIONED AT AN ANGLE OF 90 DEGREES FROM THE CLOSED <br />POSITION; OR, IN THE CASE OF A 2- OR 3-STORY SINGLE FAMILY DWELLING, ON THE 2ND OR 3RD FLOOR <br />OF THE DWELLING IF A BATHROOM OR BEDROOM IS NOT LOCATED ON THE ENTRY LEVEL. <br />E. DOORBELL BUTTONS. [R327.1.4] DOORBELL BUTTONS OR CONTROLS, WHEN INSTALLED, SHALL NOT <br />EXCEED 48” ABOVE EXTERIOR FLOOR OR LANDING, MEASURED FROM THE TOP OF THE DOORBELL <br />BUTTON ASSEMBLY. WHERE DOORBELL BUTTONS INTEGRATED WITH OTHER FEATURES ARE REQUIRED <br />TO BE INSTALLED ABOVE 48” MEASURED FROM THE EXTERIOR FLOOR OR LANDING, A STANDARD <br />DOORBELL BUTTON OR CONTROL SHALL ALSO BE PROVIDED AT A HEIGHT NOT EXCEEDING 48” ABOVE <br />EXTERIOR FLOOR OR LANDING, MEASURED FROM THE TOP OF THE DOORBELL BUTTON OR CONTROL. <br />AGING-IN-PLACE/FALL PREVENTION NOTES <br />1. SHOWER AND WALLS ABOVE BATHTUBS WITH SHOWER HEADS SHALL BE FINISHED WITH A SMOOTH, <br />NONABSORBENT SURFACE TO A HEIGHT NOT LESS THAN 72 INCH ABOVE THE DRAIN INLET. [§1210.2.3 CBC] <br />(R307.2 CRC). <br />- SHOWER PAN SHALL HAVE A MINIMUM AREA OF 1024 SQ. INCHES AND A MINIMUM FINISH DIMENSION OF <br />30 INCHES IN ANY DIRECTIONS. SHOWER DOORS SHALL OPEN SO AS TO MAINTAIN NOT LESS THAN A 22" <br />UNOBSTRUCTED OPENING FOR EGRESS. (CPC 408.6) <br />- SHOWERS AND SHOWER-TUBS SHALL BE PROVIDED WITH INDIVIDUAL CONTROL VALVES OF THE <br />PRESSURE BALANCE, THERMOSTATIC, OR COMBINATION PRESSURE BALANCE/THERMOSTATIC MIXING <br />VALVE TYPE THAT PROVIDE SCALD AND THERMAL SHOCK PROTECTION. [§408.3 CPC] <br />2. [§2406.3 CBC] SAFETY GLAZING IN THE FOLLOWING LOCATIONS: <br />·WHERE THE NEAREST EDGE OF GLAZING IS WITHIN A 24-INCH ARE OF EITHER SIDE OF A DOOR IN A <br />CLOSED POSITION (UNLESS THERE IS AN INTERVENING WALL BETWEEN THE DOOR AND THE GLAZING <br />OR IF THE GLAZING IS 5 FEET OR HIGHER ABOVE THE WALKING SURFACE). <br />·GLAZING GREATER THAN 9 SQUARE FEET WITH THE BOTTOM EDGE LESS THAN 18 INCHES ABOVE THE <br />FLOOR AND THE TOP EDGE GREATER THAN 36 INCHES ABOVE THE FLOOR (UNLESS THE GLAZING IS <br />MORE THAN 36 INCHES HORIZONTALLY AWAY FROM WALKING SURFACES OR IF A COMPLYING <br />PROTECTIVE BAR IS INSTALLED) <br />·GLAZING IN SHOWER AND TUB ENCLOSURES (LESS THAN 60 INCHES ABOVE STANDING SURFACE) <br />·GLAZING IN SWINGING AND SLIDING DOORS. <br />·GLAZING ADJACENT TO STAIRWAYS, LANDINGS AND RAMPS WITHIN 36 INCHES HORIZONTALLY OF A <br />WALKING SURFACE WHEN THE GLAZING IS LESS THAN 60 INCHES ABOVE THE PLANE OF THE ADJACENT <br />WALKING SURFACE. <br />·GLAZING LESS THAN 5 FEET HORIZONTALLY FROM SWIMMING POOLS AND LESS THAN 5 FEET ABOVE <br />ADJOINING GRADE <br />3. PROVIDE AN EXHAUST FAN IN THE BATHROOM OF 4 AIR CHANGES PER HOUR MINIMUM WITH HUMIDITY <br />CONTROL SENSOR. [§1203.5.2.1 CBC] (R303.3.1 CRC); INSTALL 50 CFM (R303.4 CRC) FAN IN EACH BATHROOM <br />4. BEDROOM EMERGENCY EGRESS: EACH BEDROOM SHALL HAVE A DOOR DIRECTLY TO THE EXTERIOR OR A <br />WINDOW THAT WILL PROVIDE A CLEAR SPACE OPENING OF AT LEAST 5.7 SQUARE FEET IN THE OPEN <br />POSITION (5 SQ. FT. AT GRADE FLOOR OPENINGS), AND A MINIMUM CLEAR OPENING WIDTH OF 20 INCHES <br />AND CLEAR OPENING HEIGHT OF 24 INCHES AND A MAXIMUM SILL HEIGHT OF 44 INCHES ABOVE THE FLOOR. <br />[§1030 CBC] (R310 CRC) <br />5. ROOM NATURAL VENTILATION REQUIREMENT. PROVIDE EXTERIOR OPENING WITH AN AREA EQUAL TO 4 <br />PERCENT OF THE FLOOR AREA. [§1203.5 CBC] (R303.1 CRC) <br />6. AT LEAST ONE EGRESS DOOR SHALL BE PROVIDED FOR EACH DWELLING UNIT THAT HAS A MINIMUM CLEAR <br />WIDTH OF 32 INCHES BETWEEN THE FACE OF THE DOOR AND THE STOP WITH THE DOOR OPENED 90°, AND A <br />MINIMUM CLEAR HEIGHT OF 78 INCHES MEASURED FROM THE TOP OF THE THRESHOLD TO THE BOTTOM OF <br />THE STOP. (R311.2 CRC) <br />7. A LANDING, WITH A WIDTH NOT LESS THAN THE WIDTH OF DOOR AND LENGTH IN THE DIRECTION OF <br />TRAVEL OF NOT LESS THAN 36 INCHES, WILL BE PROVIDED ON EACH SIDE OF DOORS. THE SLOPE AT <br />EXTERIOR LANDINGS SHALL NOT EXCEED ¼” IN VERTICAL IN 12” IN HORIZONTAL, 2%. THE ELEVATION OF <br />LANDING SHALL NOT EXCEED 1½ INCH DIFFERENCE THAN THE THRESHOLD OF THE DOORWAY (7 3/4 INCH IF <br />DOOR DOES NOT SWING OVER THE LANDING OR STEPS). [CRC R311.3] <br />8. MINIMUM 1 INCH CLEARANCE SHALL BE PROVIDED BETWEEN THE ATTIC INSULATION AND THE ROOF <br />SHEATHING WHERE CAVE OR CORNICE VENTS ARE INSTALLED. (R806.3 CRC) <br />9. DISHWASHER WITH DRAIN TO GARBAGE DISPOSAL. <br />10.SINK WITH GARBAGE DISPOSAL. <br />11. RANGE TO BE SELECTED BY OWNER. VENT TO OUTSIDE WITH BACKDRAFT DAMPER. <br />12. TOILET AND BIDET REQUIRE A MINIMUM 15 INCHES OF CLEARANCE FROM THE CENTER LINE OF THE BOWL <br />TO EACH SIDE, AND 24 INCHES FROM THE FRONT EDGE OF THE BOWL. PER 2022 [CPC 402.5] <br />13. THE MAXIMUM HOT WATER TEMPERATURE DISCHARGING FROM THE BATHTUB, SHOWER AND WHIRLPOOL <br />BATHTUB FILLER SHALL BE LIMITED TO 120 DEGREES FAHRENHEIT. THE WATER HEATER THERMOSTAT <br />SHALL NOT BE CONSIDERED A CONTROL FOR MEETING THIS PROVISION. CPC 408.3 AND 409.4 <br />14.SPLIT AC W/ HEAT PUMP IS OUTSIDE ON EXT. CONC, PAD. <br />A. MSZ-HM RESIDENTIAL DUCTLESS WALL-MOUNTED INDOOR MODEL: <br /> THE 20 SEER2 WALL-MOUNTED INDOOR UNIT PAIRS WITH A SINGLE <br />ZONE HEAT PUMP OUTDOOR UNIT. THE STYLISH FLAT PANEL DESIGN <br />OF THIS WHISPER-QUIET UNIT MAKES IT A POPULAR CHOICE, AS DOES <br />THE ENERGY-SAVING ECONO COOL FEATURE, WHICH TEMPORARILY <br />ADJUSTS THE AMOUNT OF AIR DIRECTED TOWARD OCCUPANTS. THE <br />DUCTLESS 20 SEER2 WALL-MOUNTED UNIT IS A GREAT WAY TO <br />BECOME MORE ENERGY EFFICIENT AND ENVIRONMENTALLY <br />SUSTAINABLE WITH ELECTRIC HEATING AND COOLING. <br />B. EZ-FIT® CEILING-RECESSED INDOOR UNIT <br /> DESIGNED TO FIT BETWEEN STANDARD CEILING JOISTS, THE EZ FIT <br />CEILING-RECESSED INDOOR UNIT OFFERS A CLEAN FLUSH-MOUNT <br />APPEARANCE WITHOUT DETRACTING FROM YOUR DéCOR, MAKING <br />THIS DUCTLESS RECESSED UNIT IS ONE OF OUR MOST POPULAR <br />OPTIONS. HIGH/LOW CEILING AIRFLOW SETTINGS, AUTOMATIC VANE <br />CONTROL AND MULTI-STAGE FILTRATION PERSONALIZES ROOM <br />COMFORT. <br />15. WASHER SPACE, PROVIDE COLD & HOT WATER SUPPLY, WASTE LINE AND IF ON SECOND FLOOR, A PAN WITH <br />DRAIN TO EXTERIOR. <br />16. DRYER SPACE, PROVIDE VENT TO OUTSIDE WITH SMOOTH METAL DUCT WITH BACKDRAFT DAMPER. <br />17. WHEN A DOMESTIC CLOTHES DRYER IS LOCATED IN A CLOSET, A MINIMUM OPENING OF 100 SQ. IN. FOR <br />MAKEUP AIR SHALL BE PROVIDED IN THE DOOR OR PER THE MANUFACTURERS WRITTEN INSTALLATION <br />INSTRUCTIONS. (504.3.2 CMC) <br />18. MAKEUP AIR SHALL BE PROVIDED FOR CLOTHES DRYERS IN ACCORDANCE WITH THE MANUFACTURER'S <br />INSTRUCTIONS. [NFPA 54:10.4.3.1] WHERE A CLOSET IS DESIGNED FOR THE INSTALLATION OF A CLOTHES <br />DRYER, AN OPENING OF NOT LESS THAN 100 SQUARE INCHES (0.065 M2) FOR MAKEUP AIR SHALL BE <br />PROVIDED IN THE DOOR OR BY OTHER APPROVED MEANS. <br />19. A DOMESTIC CLOTHES DRYER DUCT SHALL BE OF METAL AND A MINIMUM OF 4" IN DIAMETER. THE <br />EXHAUST DUCT SHALL NOT EXCEED A TOTAL COMBINED HORIZONTAL AND VERTICAL LENGTH OF 14', <br />INCLUDING TWO 90 DEGREE ELBOWS. TWO FEET SHALL BE DEDUCTED FOR EACH 90 DEGREE ELBOW IN <br />EXCESS OF TWO. (504.4.2.1 & 504.4.2.2 CMC) <br />20.HALLWAY WIDTHS SHALL BE 36 INCHES MINIMUM. (R311.6 CRC) <br />21.THE FOLLOWING ARE REQUIRED FOR HEAT PUMP WATER HEATERS (HPWH): <br />a. THE HPWH WILL BE INSTALLED ACCORDING TO MANUFACTURER’S REQUIREMENTS <br />b. INSTALLATION SHALL BE IN A CONDITIONED SPACE UNLESS LISTED FOR EXTERIOR INSTALLATION. <br />MODELING IN T-24 MUST MATCH. <br />c. PRESCRIPTIVE INSTALLATIONS SHALL BE INDOORS AND ON A RIGID R-10 INSULATED SURFACE. HPWH <br />MUST MEET NEEA TIER 3 OR HIGHER. [150.2(B)1HIII] <br />23. ALL NEW GARAGE DOORS SHALL BE LABELED WITH A PERMANENT LABEL PROVIDED BY THE GARAGE <br />DOOR MANUFACTURER. THE LABEL SHALL IDENTIFY THE GARAGE DOOR MANUFACTURER, THE GARAGE <br />DOOR MODEL/SERIES NUMBER, THE POSITIVE AND NEGATIVE DESIGN WIND PRESSURE RATING, THE <br />INSTALLATION DRAWING REFERENCE NUMBER, AND THE APPLICABLE TEST STANDARD. R609.4.1 <br />24. PROVIDE 5/8" GYPBOARD TYPE 'X' ON THE GARAGE SIDE WALL NEXT TO ALL LIVING AREAS. PROVIDE 5/8" <br />TYPE 'X' GYPBOARD AT CEILING IF GYPBOARD DOES NOT EXTEND TO ROOFING THROUGH THE ATTIC SPACE. <br />TABLE R302.6 <br />25. DOOR FROM GARAGE TO LIVING AREA SHALL BE A 1-3/8 THICK SOLID WOOD DOOR, SOLID OR HONEYCOMB <br />CORE STEEL DOOR, OR 20 MINUTE RATED FIRE DOOR. DOORS SHALL BE A SELF-LATCHING AND <br />SELF-CLOSING DOOR PER R302.5.1. <br />26. PROVIDE 42-INCH HIGH PROTECTIVE GUARD FOR DECKS, PORCHES, BALCONIES, WINDOW SILLS (PER 312.2.1) <br />AND RAISED FLOORS (MORE THAN 30 INCHES ABOVE GRADE OR FLOOR BELOW). OPENINGS BETWEEN RAILS <br />SHALL BE LESS THAN 4 INCHES UP TO 34" HEIGHT AND 8" OPENINGS ABOVE 34". [CRC R312.1] <br />27.1607.8 LOADS ON HANDRAILS <br />A, HANDRAILS AND GUARDS SHALL BE DESIGNED TO RESIST A LINEAR LOAD OF 50 POUNDS PER LINEAR FOOT <br />(PLF) (0.73 KN/M) IN ACCORDANCE WITH SECTION 4.5.1 OF ASCE 7. <br />B. HANDRAILS AND GUARDS SHALL BE DESIGNED TO RESIST A CONCENTRATED LOAD OF 200 POUNDS (0.89 KN) <br />IN ACCORDANCE WITH SECTION 4.5.1 OF ASCE 7 <br />28. KITCHEN VENT HOOD w/ EXHAUST VENT - ELECTRIC / EXHAUST DUCT UP <br />TO CLG. & OUT TO REAR WALL W/ RAIN CAP <br />BLACK GLASS <br />VIKING 390 CFM 30-36 INCH WIDE WALL MOUNTED RANGE HOOD <br />MODEL: MVWHS636BG <br />CFM: 390 SPEEDS: 3 <br />DUCT SIZE: 7" ROUND BULB TYPE: LED <br />WIDTH: 36 DEPTH: 20" HEIGHT: 57" <br />CEILING HEIGHT: 96" TO 120" HEIGHT ABOVE COOKTOP: 30-36" <br />VOLTAGE: 120V WATTS PER BULB: 3.5W <br />29. THRESHOLD: MAX = 7" / MIN. 1.5" THRESHOLD <br />30. ANNULAR SPACES AROUND PIPES, ELECTRIC CABLES, CONDUITS OR OTHER OPENINGS IN <br />SOLE/BOTTOM PLATES AT EXTERIOR WALLS SHALL BE PROTECTED AGAINST THE PASSAGE <br />OF RODENTS BY CLOSING SUCH OPENINGS WITH CEMENT MORTAR, CONCRETE MASONRY OF <br />SIMILAR METHODS. <br />31. Where such penetrations occur in fire-rated walls or assemblies, penetrations shall be protected with approved, listed firestop <br />systems to maintain the required fire-resistance rating in accordance with CBC Sections 714 and 715. Firestop materials shall be <br />installed per manufacturer’s listing (UL system). <br />32. AN APPROVED SEISMIC GAS SHUT OFF VALVE OR EXCESS FLOW SHUT OFF VALVE WILL BE INSTALLED ON <br />THE FUEL GAS LINE ON THE DOWN-STREAM SIDE OF THE UTILITY METER AND BE RIGIDLY CONNECTED TO <br />THE EXTERIOR OF THE BUILDING OR STRUCTURE CONTAINING THE FUEL GAS PIPING. (PER ORDINANCE <br />170,158 AND 180,670) SEPARATE PLUMBING PERMIT IS REQUIRED. <br />33. WATER HEATER MUST BE STRAPPED TO WALL. (507.3 & LAP <br />34. ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE CEILINGS ARE APPLIED DIRECTLY TO <br />THE UNDERSIDE OF ROOF RAFTERS SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE SPACE BY <br />VENTILATING OPENINGS PROTECTED AGAINST THE ENTRANCE OF RAIN OR SNOW. (R806.1) <br />35. Through penetrations and/or membrane penetrations of fire-resistance-rated wall or floor assemblies shall comply with Section <br />R302.4.1 and/or R302.4.2. respectively (R302.4) <br />FLOOR PLAN KEY NOTES:X <br />*GA WP 5513 <br />WOOD STUD (LOAD-BEARING) <br />FIRE RATING: 1 HOURS <br />SYSTEM THICKNESS: 6.75 IN. <br />STC: 45 <br />ASSEMBLY DETAILS: <br />GYPSUM PANEL: 1 LAYER 5/8" [15.9 MM] SHEETROCK® GYPSUM PANEL (UL TYPE SCX) <br />WOOD STUDS: 1 LAYER 2" X 4" [38 X 89 MM] WOOD STUDS, STAGGERED, 8" [203 MM] O.C. <br />INSULATION: 1 LAYER 3-1/2" [89 MM] FIBERGLASS INSULATION <br />GYPSUM PANEL: 1 LAYER 5/8" [15.9 MM] SHEETROCK® GYPSUM PANEL (UL TYPE SCX) <br /> (SD) SMOKE & (CM) CARBON MONOXIDE ALARM NOTES: <br /> 1. SMOKE DETECTORS SHALL BE INTERCONNECTED HARD-WIRED <br /> WITH BATTERY BACKUP. <br /> IN NEW CONSTRUCTION SMOKE DETECTORS SHALL RECEIVE <br /> THEIR PRIMARY POWER FROM THE BUILDING WIRING AND SHALL <br /> BE EQUIPPED WITH A BATTERY BACKUP. (907.2.11.4, <br /> R314.4) <br />2. CARBON MONOXIDE DETECTORS SHALL BE INTERCONNECTED <br /> HARD-WIRED WITH BATTERY BACKUP. <br /> 3. SMOKE & CARBON MONOXIDE DETECTORS SHALL BE INSTALLED <br /> IN ACCORDANCE WITH NFPA 72. <br /> 4. SMOKE & CARBON MONOXIDE DETECTORS SHALL NOT BE <br /> INSTALLED LESS THAN 3 FT FROM A DOOR OR OPENING OUTSIDE <br /> OF A BATHROOM OR SHOWER UNLESS IT AFFECTS A/C (R314.3.3) <br /> WHEN MORE THAN ONE SMOKE ALARM IS REQUIRED, IT IS TO BE <br /> INSTALLED WITHIN AN INDIVIDUAL DWELLING UNIT. THE ALARM <br /> DEVICE SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE <br /> ACTUATION OF ONE ALARM WILL ACTIVATE ALL OF THE OTHER <br /> ALARMS IN THE INDIVIDUAL UNIT. RESIDENTIAL CODE R314.3 <br />CM CARBON MONOXIDE <br />ALARM, CEILING MOUNTED, HARD WIRED <br />AND W/ BATTERY BACK UP.ICC APPROVED <br />SMOKE DETECTOR, HARD WIRED <br />AND W/ BATTERY BACK UP.ICC APPROVED <br />(INSTALL AS PER 2022 CBC) INTERCONNECTED <br />KITCHEN EXHAUST FAN - 28O CFM MIN. IF GAS OR 130 CFM IF <br />ELECTRIC: <br />VENT TO OUTSIDE AIR. <br />BATHROOM FAN- EXHAUST FAN TYP. W/INTEGRAL <br />HUMDISTAT OR MIN CONTINUOUS 35 CFM, AIRFLOW <br />(CFM) 96, FAN POWER (WATTS/CFM) 0.45 <br />AC/ MINI SPLIT SYSTEM W/ HEAT CONDENSER <br />(EFF EER/CEER= 20/EFF SEER=18) W/ 4" CONC. PAD <br />LIGHTING/EXHAUST FANS <br />Sheet: 1 <br />File: ..\..\..\25-006 LONE WOLF DESIGNS\-06 AUTRY AVE - ADU\WALL ASSEMB.pdf <br />Missing or invalid reference <br />A-2 <br />LOWER FLOOR PLAN <br />Job # <br />Sheet No.: <br />Date <br />Ap <br />p <br />l <br />i <br />c <br />a <br />n <br />t <br /> <br />: <br />Pr <br />o <br />j <br />e <br />c <br />t <br /> <br />f <br />o <br />r <br />: <br />Co <br />n <br />t <br />a <br />c <br />t <br />: <br />To <br />n <br />y <br /> <br />V <br />u <br />Ma <br />s <br />t <br />e <br />r <br /> <br />C <br />o <br />n <br />s <br />t <br />r <br />u <br />c <br />t <br />i <br />o <br />n <br />REVISIONS <br />SEAL: <br />SHEET DESCRIPTION : <br />Te <br />l <br />. <br /> <br />( <br />7 <br />1 <br />4 <br />) <br /> <br />5 <br />6 <br />8 <br />- <br />5 <br />4 <br />4 <br />4 <br />N2308 <br />SCALE: <br />DATENO: REVISIONS <br />AT <br />T <br />A <br />C <br />H <br />E <br />D <br /> <br />A <br />D <br />U <br />PLAN LEGEND: <br />DOOR SCHEDULE IDENTIFICAITON, SEE DOOR SCHEDULE <br />WINDOW SCHEDULE IDENTIFICAITON, SEE WINDOW SCHEDULE <br />ELEVATION VIEW <br />A <br />2 <br />A1 <br />DOOR & WINDOW SCHEDULE - ATTACHED ADU <br />HW SIL HTMARK REMARK / MATERIAL <br />4'-0"4'-0"1 <br />D <br />O <br />O <br />R <br />3W <br />I <br />N <br />D <br />O <br />W <br />03'-0" 6'-8"A 1 <br /> QTY <br />X <br />02'-4" 6'-8"B 1 EXTERIOR SOLID WOOD <br />SLIDING VINYL FRAME <br />3'-6"2'-0"2 2 SLIDING VINYL FRAME <br />* ALL (N)WINDOW U-FACTOR = 0.30 & SHGC = 0.23 <br />EXTERIOR SOLID WOOD <br />2'-8" <br />3'-2" <br />03'-0" 6'-8"C 2 INTERIOR HOLLOW <br />4'-0"3'-0"3 22'-8" <br />D <br />6'-0" 6'-8"0 1 SLIDING VINYL FRAMEE <br />02'-6" 6'-8" 4 INTERIOR HOLLOW <br />CLOSET <br />LIVING ROOM <br />BATHROOM <br />KITCHEN <br />CL <br />O <br />S <br />E <br />T <br />BATHROOM <br />BEDROOM 1 <br />MASTER <br />BEDROOM <br />12'-4"5' <br />12'8' <br />4' <br />12'-10" <br />5'-2" <br />2'-5" <br />6'-10" <br />2'-11" <br />3'-3" <br />5'-2" <br />4' <br />7' <br />4'11'-6" <br />20'-1" <br />2'4'-10" <br />4'-6" <br />8'-3" <br />7'-1"3'-4" <br />5' <br />72 <br />2 <br />1 <br /> <br />G <br />a <br />r <br />d <br />e <br />n <br /> <br />G <br />r <br />o <br />v <br />e <br /> <br />B <br />l <br />v <br />d <br />, <br /> <br />G <br />a <br />r <br />d <br />e <br />n <br /> <br />G <br />r <br />o <br />v <br />e <br />, <br /> <br /># <br />J <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />8 <br />4 <br />1 <br />Te <br />l <br />. <br /> <br />( <br />7 <br />1 <br />4 <br />) <br /> <br />5 <br />6 <br />8 <br />- <br />5 <br />4 <br />4 <br />4 <br />34 <br />1 <br />4 <br /> <br />S <br /> <br />T <br />I <br />M <br />B <br />E <br />R <br /> <br />S <br />T <br />, <br /> <br />U <br />N <br />I <br />T <br /> <br /># <br />2 <br /> <br />( <br />A <br />D <br />U <br />) <br />34 <br />1 <br />4 <br /> <br />S <br /> <br />T <br />I <br />M <br />B <br />E <br />R <br /> <br />S <br />T <br /> <br />( <br />S <br />F <br />R <br />) <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />. <br /> <br />C <br />A <br />. <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />MASTER <br />BEDROOM <br />BEDROOM <br />BEDROOM <br />BEDROOM <br />KITCHEN <br />LIVING ROOM <br />DINING ROOM <br />GARAGE <br />9'-8" <br />ENTRY <br />PORCH <br />COVERED <br />PATIO <br />5' <br />EXISTING WALL <br />NEW WALL <br />A-42 <br />A-32 <br />A-33 <br />A-34 <br />A <br />D <br />D <br />B WH <br />STACKING <br />E <br />1 <br />1 <br />1 <br />4 <br />3 <br />2 <br />2 <br />4 <br />3'SLIDING VINYL FRAME <br />1'-6"2'-6"4 1 SLIDING VINYL FRAME <br />TEMP. GLAZ <br />11' <br />A-41 <br />A-82 <br />A-51 <br />A-5252'-7" <br />20'-8" <br />23'-3" <br />8'-1" <br />5'-2" <br />21'-3" <br />25' <br />20'-2" <br />9'-10" <br />20'-1"9'-9" <br />1 ATTACHED ADU FLOOR PLAN <br />*1-HR FIRE RATED WALL (GA WP 5513) <br />C <br />C <br />1 1 <br />STACKING <br />W/D <br />5'-10" <br />7'-3" <br />4' <br />4' <br />*1-HR FIRE RATED WALL <br />*1-HR FIRE RATED WALL <br />*1-HR FIRE RATED WALL (GA WP 5513) <br />Provide one-hour protection on the <br />underside of eave when eaves <br />projected into the 5-ft of fire <br />separation distance, TYP. <br />2' <br />1 <br />1 <br />1 <br />11/24/25 <br />AS NOTED <br />11.24.251 REVISIONS <br />2'-6" <br />3' <br />17'-9" <br />213"=TOTAL <br />25% = 54" <br />54" OK <br />1 <br />1 1 <br />3 <br />3" <br />1'-1" <br />TEMP. GLAZ <br />TEMP. GLAZ <br />TEMP. GLAZ <br />TEMP. GLAZ 1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />2'-6" <br />EG <br />R <br />E <br />S <br />S <br />EG <br />R <br />E <br />S <br />S <br />5'-6" <br />3'-6" <br />4'-1" <br />1 <br />13'-11" <br />13'-7" <br />5' <br />5'-4"4'2' <br />6' <br />4' <br />3' <br />4' <br />4' <br />4' <br />4'4' <br />2'-8" <br />18' <br />2'-6" <br />5'-10" <br />3' <br />5'-4" <br />9'-10" <br />10' <br />10' <br />11'-11" <br />10'10' <br />11' <br />29'-5" <br />26'-3" <br />1 <br />1 <br />1 AC/ MINI SPLIT SYSTEM <br />W/ HEAT CONDENSER <br /> (EFF EER/CEER= 20/EFF <br />SEER=18) W/ 4" CONC. PAD <br />REFER TO NOTE #14 <br />1 <br />1'-4"1'-4" <br />2' <br />2'-6" <br />1'-3" <br />1'-3" <br />2'-6" <br />1 <br />1 <br />STC 52 <br />INTERIOR WALL <br />STC 52INTERIOR WALL <br />2'-6" <br />1'-10" <br />Sheet: 1 <br />File: C:\Users\exoma\Downloads\W-CW-1-12 (2).pdf <br />Missing or invalid reference <br />30" MIN CLEAR <br />HEAD ROOM <br />2 <br />A7 <br />1 <br />A7