<br />3414 S TIMBER ST
<br />MAIN HOUSE 2,171 SQFT
<br />(N) 1-HR FIRE RATED WALL
<br />.
<br />VENT HOOD
<br />RANGE
<br />ATTICACCESS
<br />A. REINFORCEMENT FOR GRAB BARS. [R327.1.1] AT LEAST ONE BATHROOM ON THE ENTRY LEVEL SHALL
<br />BE PROVIDED WITH REINFORCEMENT INSTALLED IN ACCORDANCE WITH THIS SECTION. WHERE THERE
<br />IS NO BATHROOM ON THE ENTRY LEVEL, AT LEAST ONE BATHROOM ON THE 2ND OR 3RD FLOOR OF THE
<br />DWELLING SHALL COMPLY WITH THIS SECTION.
<br />1. REINFORCEMENT SHALL BE SOLID LUMBER OR OTHER CONSTRUCTION MATERIALS APPROVED
<br />BY THE ENFORCING AGENCY.
<br />2. REINFORCEMENT SHALL NOT BE LESS THAN 2 BY 8 INCH NOMINAL LUMBER (1-1/2” X 7-1/4”
<br />ACTUAL DIMENSION) OR OTHER CONSTRUCTION MATERIAL PROVIDING EQUAL HEIGHT AND LOAD
<br />CAPACITY. REINFORCEMENT SHALL BE LOCATED BETWEEN 32” AND 39-1/4” ABOVE THE FINISHED
<br />FLOOR, FLUSH WITH THE WALL FRAMING.
<br />3. WATER CLOSET REINFORCEMENT SHALL BE INSTALLED ON BOTH SIDE WALLS OF THE FIXTURE,
<br />OR ONE SIDE WALL AND THE BACK WALL.
<br />4. SHOWER REINFORCEMENT SHALL BE CONTINUOUS WHERE WALL FRAMING IS PROVIDED.
<br />5. BATHTUB AND COMBINATION BATHTUB/SHOWER REINFORCEMENT SHALL BE CONTINUOUS ON
<br />EACH END OF THE BATHTUB AND THE BACK WALL. ADDITIONALLY, BACK WALL REINFORCEMENT
<br />FOR A LOWER GRAB BAR SHALL BE PROVIDED WITH THE BOTTOM EDGE LOCATED NO MORE THAN
<br />6” ABOVE THE BATHTUB RIM.
<br />6. WHERE THE WATER CLOSET IS NOT PLACED ADJACENT TO A SIDE WALL CAPABLE OF
<br />ACCOMMODATING A GRAB BAR, THE BATHROOM SHALL HAVE PROVISIONS FOR INSTALLATION OF
<br />FLOOR-MOUNTED, FOLDAWAY OR SIMILAR ALTERNATE GRAB BAR REINFORCEMENTS APPROVED
<br />BY THE ENFORCING AGENCY.
<br />B. DOCUMENTATION FOR GRAB BAR REINFORCEMENT. [R327.1.1.1] INFORMATION AND/OR DRAWINGS
<br />IDENTIFYING THE LOCATION OF GRAB BAR REINFORCEMENT SHALL BE PLACED IN THE OPERATION &
<br />MAINTENANCE MANUAL IN ACCORDANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS CODE,
<br />CH. 4, DIVISION 4.4.
<br />C. ELECTRICAL RECEPTACLE OUTLET, SWITCH & CONTROL HEIGHTS. [R327.1.2] ELECTRICAL
<br />RECEPTACLE OUTLETS, SWITCHES AND CONTROLS (INCLUDING CONTROLS FOR HEATING, VENTILATION
<br />AND AIR CONDITIONING) INTENDED TO BE USED BY OCCUPANTS SHALL BE LOCATED NO MORE THAN
<br />48” MEASURED FROM THE TOP OF THE OUTLET BOX AND NOT LESS THAN 15” MEASURED FROM THE
<br />BOTTOM OF THE OUTLET BOX ABOVE THE FINISH FLOOR.
<br />D. INTERIOR DOORS. [R327.1.3] EFFECTIVE JULY 1, 2024, AT LEAST ONE BATHROOM AND ONE BEDROOM
<br />ON THE ENTRY LEVEL SHALL PROVIDE A DOORWAY WITH A NET CLEAR OPENING OF NOT LESS THAN
<br />32”, MEASURED WITH THE DOOR POSITIONED AT AN ANGLE OF 90 DEGREES FROM THE CLOSED
<br />POSITION; OR, IN THE CASE OF A 2- OR 3-STORY SINGLE FAMILY DWELLING, ON THE 2ND OR 3RD FLOOR
<br />OF THE DWELLING IF A BATHROOM OR BEDROOM IS NOT LOCATED ON THE ENTRY LEVEL.
<br />E. DOORBELL BUTTONS. [R327.1.4] DOORBELL BUTTONS OR CONTROLS, WHEN INSTALLED, SHALL NOT
<br />EXCEED 48” ABOVE EXTERIOR FLOOR OR LANDING, MEASURED FROM THE TOP OF THE DOORBELL
<br />BUTTON ASSEMBLY. WHERE DOORBELL BUTTONS INTEGRATED WITH OTHER FEATURES ARE REQUIRED
<br />TO BE INSTALLED ABOVE 48” MEASURED FROM THE EXTERIOR FLOOR OR LANDING, A STANDARD
<br />DOORBELL BUTTON OR CONTROL SHALL ALSO BE PROVIDED AT A HEIGHT NOT EXCEEDING 48” ABOVE
<br />EXTERIOR FLOOR OR LANDING, MEASURED FROM THE TOP OF THE DOORBELL BUTTON OR CONTROL.
<br />AGING-IN-PLACE/FALL PREVENTION NOTES
<br />1. SHOWER AND WALLS ABOVE BATHTUBS WITH SHOWER HEADS SHALL BE FINISHED WITH A SMOOTH,
<br />NONABSORBENT SURFACE TO A HEIGHT NOT LESS THAN 72 INCH ABOVE THE DRAIN INLET. [§1210.2.3 CBC]
<br />(R307.2 CRC).
<br />- SHOWER PAN SHALL HAVE A MINIMUM AREA OF 1024 SQ. INCHES AND A MINIMUM FINISH DIMENSION OF
<br />30 INCHES IN ANY DIRECTIONS. SHOWER DOORS SHALL OPEN SO AS TO MAINTAIN NOT LESS THAN A 22"
<br />UNOBSTRUCTED OPENING FOR EGRESS. (CPC 408.6)
<br />- SHOWERS AND SHOWER-TUBS SHALL BE PROVIDED WITH INDIVIDUAL CONTROL VALVES OF THE
<br />PRESSURE BALANCE, THERMOSTATIC, OR COMBINATION PRESSURE BALANCE/THERMOSTATIC MIXING
<br />VALVE TYPE THAT PROVIDE SCALD AND THERMAL SHOCK PROTECTION. [§408.3 CPC]
<br />2. [§2406.3 CBC] SAFETY GLAZING IN THE FOLLOWING LOCATIONS:
<br />·WHERE THE NEAREST EDGE OF GLAZING IS WITHIN A 24-INCH ARE OF EITHER SIDE OF A DOOR IN A
<br />CLOSED POSITION (UNLESS THERE IS AN INTERVENING WALL BETWEEN THE DOOR AND THE GLAZING
<br />OR IF THE GLAZING IS 5 FEET OR HIGHER ABOVE THE WALKING SURFACE).
<br />·GLAZING GREATER THAN 9 SQUARE FEET WITH THE BOTTOM EDGE LESS THAN 18 INCHES ABOVE THE
<br />FLOOR AND THE TOP EDGE GREATER THAN 36 INCHES ABOVE THE FLOOR (UNLESS THE GLAZING IS
<br />MORE THAN 36 INCHES HORIZONTALLY AWAY FROM WALKING SURFACES OR IF A COMPLYING
<br />PROTECTIVE BAR IS INSTALLED)
<br />·GLAZING IN SHOWER AND TUB ENCLOSURES (LESS THAN 60 INCHES ABOVE STANDING SURFACE)
<br />·GLAZING IN SWINGING AND SLIDING DOORS.
<br />·GLAZING ADJACENT TO STAIRWAYS, LANDINGS AND RAMPS WITHIN 36 INCHES HORIZONTALLY OF A
<br />WALKING SURFACE WHEN THE GLAZING IS LESS THAN 60 INCHES ABOVE THE PLANE OF THE ADJACENT
<br />WALKING SURFACE.
<br />·GLAZING LESS THAN 5 FEET HORIZONTALLY FROM SWIMMING POOLS AND LESS THAN 5 FEET ABOVE
<br />ADJOINING GRADE
<br />3. PROVIDE AN EXHAUST FAN IN THE BATHROOM OF 4 AIR CHANGES PER HOUR MINIMUM WITH HUMIDITY
<br />CONTROL SENSOR. [§1203.5.2.1 CBC] (R303.3.1 CRC); INSTALL 50 CFM (R303.4 CRC) FAN IN EACH BATHROOM
<br />4. BEDROOM EMERGENCY EGRESS: EACH BEDROOM SHALL HAVE A DOOR DIRECTLY TO THE EXTERIOR OR A
<br />WINDOW THAT WILL PROVIDE A CLEAR SPACE OPENING OF AT LEAST 5.7 SQUARE FEET IN THE OPEN
<br />POSITION (5 SQ. FT. AT GRADE FLOOR OPENINGS), AND A MINIMUM CLEAR OPENING WIDTH OF 20 INCHES
<br />AND CLEAR OPENING HEIGHT OF 24 INCHES AND A MAXIMUM SILL HEIGHT OF 44 INCHES ABOVE THE FLOOR.
<br />[§1030 CBC] (R310 CRC)
<br />5. ROOM NATURAL VENTILATION REQUIREMENT. PROVIDE EXTERIOR OPENING WITH AN AREA EQUAL TO 4
<br />PERCENT OF THE FLOOR AREA. [§1203.5 CBC] (R303.1 CRC)
<br />6. AT LEAST ONE EGRESS DOOR SHALL BE PROVIDED FOR EACH DWELLING UNIT THAT HAS A MINIMUM CLEAR
<br />WIDTH OF 32 INCHES BETWEEN THE FACE OF THE DOOR AND THE STOP WITH THE DOOR OPENED 90°, AND A
<br />MINIMUM CLEAR HEIGHT OF 78 INCHES MEASURED FROM THE TOP OF THE THRESHOLD TO THE BOTTOM OF
<br />THE STOP. (R311.2 CRC)
<br />7. A LANDING, WITH A WIDTH NOT LESS THAN THE WIDTH OF DOOR AND LENGTH IN THE DIRECTION OF
<br />TRAVEL OF NOT LESS THAN 36 INCHES, WILL BE PROVIDED ON EACH SIDE OF DOORS. THE SLOPE AT
<br />EXTERIOR LANDINGS SHALL NOT EXCEED ¼” IN VERTICAL IN 12” IN HORIZONTAL, 2%. THE ELEVATION OF
<br />LANDING SHALL NOT EXCEED 1½ INCH DIFFERENCE THAN THE THRESHOLD OF THE DOORWAY (7 3/4 INCH IF
<br />DOOR DOES NOT SWING OVER THE LANDING OR STEPS). [CRC R311.3]
<br />8. MINIMUM 1 INCH CLEARANCE SHALL BE PROVIDED BETWEEN THE ATTIC INSULATION AND THE ROOF
<br />SHEATHING WHERE CAVE OR CORNICE VENTS ARE INSTALLED. (R806.3 CRC)
<br />9. DISHWASHER WITH DRAIN TO GARBAGE DISPOSAL.
<br />10.SINK WITH GARBAGE DISPOSAL.
<br />11. RANGE TO BE SELECTED BY OWNER. VENT TO OUTSIDE WITH BACKDRAFT DAMPER.
<br />12. TOILET AND BIDET REQUIRE A MINIMUM 15 INCHES OF CLEARANCE FROM THE CENTER LINE OF THE BOWL
<br />TO EACH SIDE, AND 24 INCHES FROM THE FRONT EDGE OF THE BOWL. PER 2022 [CPC 402.5]
<br />13. THE MAXIMUM HOT WATER TEMPERATURE DISCHARGING FROM THE BATHTUB, SHOWER AND WHIRLPOOL
<br />BATHTUB FILLER SHALL BE LIMITED TO 120 DEGREES FAHRENHEIT. THE WATER HEATER THERMOSTAT
<br />SHALL NOT BE CONSIDERED A CONTROL FOR MEETING THIS PROVISION. CPC 408.3 AND 409.4
<br />14.SPLIT AC W/ HEAT PUMP IS OUTSIDE ON EXT. CONC, PAD.
<br />A. MSZ-HM RESIDENTIAL DUCTLESS WALL-MOUNTED INDOOR MODEL:
<br /> THE 20 SEER2 WALL-MOUNTED INDOOR UNIT PAIRS WITH A SINGLE
<br />ZONE HEAT PUMP OUTDOOR UNIT. THE STYLISH FLAT PANEL DESIGN
<br />OF THIS WHISPER-QUIET UNIT MAKES IT A POPULAR CHOICE, AS DOES
<br />THE ENERGY-SAVING ECONO COOL FEATURE, WHICH TEMPORARILY
<br />ADJUSTS THE AMOUNT OF AIR DIRECTED TOWARD OCCUPANTS. THE
<br />DUCTLESS 20 SEER2 WALL-MOUNTED UNIT IS A GREAT WAY TO
<br />BECOME MORE ENERGY EFFICIENT AND ENVIRONMENTALLY
<br />SUSTAINABLE WITH ELECTRIC HEATING AND COOLING.
<br />B. EZ-FIT® CEILING-RECESSED INDOOR UNIT
<br /> DESIGNED TO FIT BETWEEN STANDARD CEILING JOISTS, THE EZ FIT
<br />CEILING-RECESSED INDOOR UNIT OFFERS A CLEAN FLUSH-MOUNT
<br />APPEARANCE WITHOUT DETRACTING FROM YOUR DéCOR, MAKING
<br />THIS DUCTLESS RECESSED UNIT IS ONE OF OUR MOST POPULAR
<br />OPTIONS. HIGH/LOW CEILING AIRFLOW SETTINGS, AUTOMATIC VANE
<br />CONTROL AND MULTI-STAGE FILTRATION PERSONALIZES ROOM
<br />COMFORT.
<br />15. WASHER SPACE, PROVIDE COLD & HOT WATER SUPPLY, WASTE LINE AND IF ON SECOND FLOOR, A PAN WITH
<br />DRAIN TO EXTERIOR.
<br />16. DRYER SPACE, PROVIDE VENT TO OUTSIDE WITH SMOOTH METAL DUCT WITH BACKDRAFT DAMPER.
<br />17. WHEN A DOMESTIC CLOTHES DRYER IS LOCATED IN A CLOSET, A MINIMUM OPENING OF 100 SQ. IN. FOR
<br />MAKEUP AIR SHALL BE PROVIDED IN THE DOOR OR PER THE MANUFACTURERS WRITTEN INSTALLATION
<br />INSTRUCTIONS. (504.3.2 CMC)
<br />18. MAKEUP AIR SHALL BE PROVIDED FOR CLOTHES DRYERS IN ACCORDANCE WITH THE MANUFACTURER'S
<br />INSTRUCTIONS. [NFPA 54:10.4.3.1] WHERE A CLOSET IS DESIGNED FOR THE INSTALLATION OF A CLOTHES
<br />DRYER, AN OPENING OF NOT LESS THAN 100 SQUARE INCHES (0.065 M2) FOR MAKEUP AIR SHALL BE
<br />PROVIDED IN THE DOOR OR BY OTHER APPROVED MEANS.
<br />19. A DOMESTIC CLOTHES DRYER DUCT SHALL BE OF METAL AND A MINIMUM OF 4" IN DIAMETER. THE
<br />EXHAUST DUCT SHALL NOT EXCEED A TOTAL COMBINED HORIZONTAL AND VERTICAL LENGTH OF 14',
<br />INCLUDING TWO 90 DEGREE ELBOWS. TWO FEET SHALL BE DEDUCTED FOR EACH 90 DEGREE ELBOW IN
<br />EXCESS OF TWO. (504.4.2.1 & 504.4.2.2 CMC)
<br />20.HALLWAY WIDTHS SHALL BE 36 INCHES MINIMUM. (R311.6 CRC)
<br />21.THE FOLLOWING ARE REQUIRED FOR HEAT PUMP WATER HEATERS (HPWH):
<br />a. THE HPWH WILL BE INSTALLED ACCORDING TO MANUFACTURER’S REQUIREMENTS
<br />b. INSTALLATION SHALL BE IN A CONDITIONED SPACE UNLESS LISTED FOR EXTERIOR INSTALLATION.
<br />MODELING IN T-24 MUST MATCH.
<br />c. PRESCRIPTIVE INSTALLATIONS SHALL BE INDOORS AND ON A RIGID R-10 INSULATED SURFACE. HPWH
<br />MUST MEET NEEA TIER 3 OR HIGHER. [150.2(B)1HIII]
<br />23. ALL NEW GARAGE DOORS SHALL BE LABELED WITH A PERMANENT LABEL PROVIDED BY THE GARAGE
<br />DOOR MANUFACTURER. THE LABEL SHALL IDENTIFY THE GARAGE DOOR MANUFACTURER, THE GARAGE
<br />DOOR MODEL/SERIES NUMBER, THE POSITIVE AND NEGATIVE DESIGN WIND PRESSURE RATING, THE
<br />INSTALLATION DRAWING REFERENCE NUMBER, AND THE APPLICABLE TEST STANDARD. R609.4.1
<br />24. PROVIDE 5/8" GYPBOARD TYPE 'X' ON THE GARAGE SIDE WALL NEXT TO ALL LIVING AREAS. PROVIDE 5/8"
<br />TYPE 'X' GYPBOARD AT CEILING IF GYPBOARD DOES NOT EXTEND TO ROOFING THROUGH THE ATTIC SPACE.
<br />TABLE R302.6
<br />25. DOOR FROM GARAGE TO LIVING AREA SHALL BE A 1-3/8 THICK SOLID WOOD DOOR, SOLID OR HONEYCOMB
<br />CORE STEEL DOOR, OR 20 MINUTE RATED FIRE DOOR. DOORS SHALL BE A SELF-LATCHING AND
<br />SELF-CLOSING DOOR PER R302.5.1.
<br />26. PROVIDE 42-INCH HIGH PROTECTIVE GUARD FOR DECKS, PORCHES, BALCONIES, WINDOW SILLS (PER 312.2.1)
<br />AND RAISED FLOORS (MORE THAN 30 INCHES ABOVE GRADE OR FLOOR BELOW). OPENINGS BETWEEN RAILS
<br />SHALL BE LESS THAN 4 INCHES UP TO 34" HEIGHT AND 8" OPENINGS ABOVE 34". [CRC R312.1]
<br />27.1607.8 LOADS ON HANDRAILS
<br />A, HANDRAILS AND GUARDS SHALL BE DESIGNED TO RESIST A LINEAR LOAD OF 50 POUNDS PER LINEAR FOOT
<br />(PLF) (0.73 KN/M) IN ACCORDANCE WITH SECTION 4.5.1 OF ASCE 7.
<br />B. HANDRAILS AND GUARDS SHALL BE DESIGNED TO RESIST A CONCENTRATED LOAD OF 200 POUNDS (0.89 KN)
<br />IN ACCORDANCE WITH SECTION 4.5.1 OF ASCE 7
<br />28. KITCHEN VENT HOOD w/ EXHAUST VENT - ELECTRIC / EXHAUST DUCT UP
<br />TO CLG. & OUT TO REAR WALL W/ RAIN CAP
<br />BLACK GLASS
<br />VIKING 390 CFM 30-36 INCH WIDE WALL MOUNTED RANGE HOOD
<br />MODEL: MVWHS636BG
<br />CFM: 390 SPEEDS: 3
<br />DUCT SIZE: 7" ROUND BULB TYPE: LED
<br />WIDTH: 36 DEPTH: 20" HEIGHT: 57"
<br />CEILING HEIGHT: 96" TO 120" HEIGHT ABOVE COOKTOP: 30-36"
<br />VOLTAGE: 120V WATTS PER BULB: 3.5W
<br />29. THRESHOLD: MAX = 7" / MIN. 1.5" THRESHOLD
<br />30. ANNULAR SPACES AROUND PIPES, ELECTRIC CABLES, CONDUITS OR OTHER OPENINGS IN
<br />SOLE/BOTTOM PLATES AT EXTERIOR WALLS SHALL BE PROTECTED AGAINST THE PASSAGE
<br />OF RODENTS BY CLOSING SUCH OPENINGS WITH CEMENT MORTAR, CONCRETE MASONRY OF
<br />SIMILAR METHODS.
<br />31. Where such penetrations occur in fire-rated walls or assemblies, penetrations shall be protected with approved, listed firestop
<br />systems to maintain the required fire-resistance rating in accordance with CBC Sections 714 and 715. Firestop materials shall be
<br />installed per manufacturer’s listing (UL system).
<br />32. AN APPROVED SEISMIC GAS SHUT OFF VALVE OR EXCESS FLOW SHUT OFF VALVE WILL BE INSTALLED ON
<br />THE FUEL GAS LINE ON THE DOWN-STREAM SIDE OF THE UTILITY METER AND BE RIGIDLY CONNECTED TO
<br />THE EXTERIOR OF THE BUILDING OR STRUCTURE CONTAINING THE FUEL GAS PIPING. (PER ORDINANCE
<br />170,158 AND 180,670) SEPARATE PLUMBING PERMIT IS REQUIRED.
<br />33. WATER HEATER MUST BE STRAPPED TO WALL. (507.3 & LAP
<br />34. ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE CEILINGS ARE APPLIED DIRECTLY TO
<br />THE UNDERSIDE OF ROOF RAFTERS SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE SPACE BY
<br />VENTILATING OPENINGS PROTECTED AGAINST THE ENTRANCE OF RAIN OR SNOW. (R806.1)
<br />35. Through penetrations and/or membrane penetrations of fire-resistance-rated wall or floor assemblies shall comply with Section
<br />R302.4.1 and/or R302.4.2. respectively (R302.4)
<br />FLOOR PLAN KEY NOTES:X
<br />*GA WP 5513
<br />WOOD STUD (LOAD-BEARING)
<br />FIRE RATING: 1 HOURS
<br />SYSTEM THICKNESS: 6.75 IN.
<br />STC: 45
<br />ASSEMBLY DETAILS:
<br />GYPSUM PANEL: 1 LAYER 5/8" [15.9 MM] SHEETROCK® GYPSUM PANEL (UL TYPE SCX)
<br />WOOD STUDS: 1 LAYER 2" X 4" [38 X 89 MM] WOOD STUDS, STAGGERED, 8" [203 MM] O.C.
<br />INSULATION: 1 LAYER 3-1/2" [89 MM] FIBERGLASS INSULATION
<br />GYPSUM PANEL: 1 LAYER 5/8" [15.9 MM] SHEETROCK® GYPSUM PANEL (UL TYPE SCX)
<br /> (SD) SMOKE & (CM) CARBON MONOXIDE ALARM NOTES:
<br /> 1. SMOKE DETECTORS SHALL BE INTERCONNECTED HARD-WIRED
<br /> WITH BATTERY BACKUP.
<br /> IN NEW CONSTRUCTION SMOKE DETECTORS SHALL RECEIVE
<br /> THEIR PRIMARY POWER FROM THE BUILDING WIRING AND SHALL
<br /> BE EQUIPPED WITH A BATTERY BACKUP. (907.2.11.4,
<br /> R314.4)
<br />2. CARBON MONOXIDE DETECTORS SHALL BE INTERCONNECTED
<br /> HARD-WIRED WITH BATTERY BACKUP.
<br /> 3. SMOKE & CARBON MONOXIDE DETECTORS SHALL BE INSTALLED
<br /> IN ACCORDANCE WITH NFPA 72.
<br /> 4. SMOKE & CARBON MONOXIDE DETECTORS SHALL NOT BE
<br /> INSTALLED LESS THAN 3 FT FROM A DOOR OR OPENING OUTSIDE
<br /> OF A BATHROOM OR SHOWER UNLESS IT AFFECTS A/C (R314.3.3)
<br /> WHEN MORE THAN ONE SMOKE ALARM IS REQUIRED, IT IS TO BE
<br /> INSTALLED WITHIN AN INDIVIDUAL DWELLING UNIT. THE ALARM
<br /> DEVICE SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE
<br /> ACTUATION OF ONE ALARM WILL ACTIVATE ALL OF THE OTHER
<br /> ALARMS IN THE INDIVIDUAL UNIT. RESIDENTIAL CODE R314.3
<br />CM CARBON MONOXIDE
<br />ALARM, CEILING MOUNTED, HARD WIRED
<br />AND W/ BATTERY BACK UP.ICC APPROVED
<br />SMOKE DETECTOR, HARD WIRED
<br />AND W/ BATTERY BACK UP.ICC APPROVED
<br />(INSTALL AS PER 2022 CBC) INTERCONNECTED
<br />KITCHEN EXHAUST FAN - 28O CFM MIN. IF GAS OR 130 CFM IF
<br />ELECTRIC:
<br />VENT TO OUTSIDE AIR.
<br />BATHROOM FAN- EXHAUST FAN TYP. W/INTEGRAL
<br />HUMDISTAT OR MIN CONTINUOUS 35 CFM, AIRFLOW
<br />(CFM) 96, FAN POWER (WATTS/CFM) 0.45
<br />AC/ MINI SPLIT SYSTEM W/ HEAT CONDENSER
<br />(EFF EER/CEER= 20/EFF SEER=18) W/ 4" CONC. PAD
<br />LIGHTING/EXHAUST FANS
<br />Sheet: 1
<br />File: ..\..\..\25-006 LONE WOLF DESIGNS\-06 AUTRY AVE - ADU\WALL ASSEMB.pdf
<br />Missing or invalid reference
<br />A-2
<br />LOWER FLOOR PLAN
<br />Job #
<br />Sheet No.:
<br />Date
<br />Ap
<br />p
<br />l
<br />i
<br />c
<br />a
<br />n
<br />t
<br />
<br />:
<br />Pr
<br />o
<br />j
<br />e
<br />c
<br />t
<br />
<br />f
<br />o
<br />r
<br />:
<br />Co
<br />n
<br />t
<br />a
<br />c
<br />t
<br />:
<br />To
<br />n
<br />y
<br />
<br />V
<br />u
<br />Ma
<br />s
<br />t
<br />e
<br />r
<br />
<br />C
<br />o
<br />n
<br />s
<br />t
<br />r
<br />u
<br />c
<br />t
<br />i
<br />o
<br />n
<br />REVISIONS
<br />SEAL:
<br />SHEET DESCRIPTION :
<br />Te
<br />l
<br />.
<br />
<br />(
<br />7
<br />1
<br />4
<br />)
<br />
<br />5
<br />6
<br />8
<br />-
<br />5
<br />4
<br />4
<br />4
<br />N2308
<br />SCALE:
<br />DATENO: REVISIONS
<br />AT
<br />T
<br />A
<br />C
<br />H
<br />E
<br />D
<br />
<br />A
<br />D
<br />U
<br />PLAN LEGEND:
<br />DOOR SCHEDULE IDENTIFICAITON, SEE DOOR SCHEDULE
<br />WINDOW SCHEDULE IDENTIFICAITON, SEE WINDOW SCHEDULE
<br />ELEVATION VIEW
<br />A
<br />2
<br />A1
<br />DOOR & WINDOW SCHEDULE - ATTACHED ADU
<br />HW SIL HTMARK REMARK / MATERIAL
<br />4'-0"4'-0"1
<br />D
<br />O
<br />O
<br />R
<br />3W
<br />I
<br />N
<br />D
<br />O
<br />W
<br />03'-0" 6'-8"A 1
<br /> QTY
<br />X
<br />02'-4" 6'-8"B 1 EXTERIOR SOLID WOOD
<br />SLIDING VINYL FRAME
<br />3'-6"2'-0"2 2 SLIDING VINYL FRAME
<br />* ALL (N)WINDOW U-FACTOR = 0.30 & SHGC = 0.23
<br />EXTERIOR SOLID WOOD
<br />2'-8"
<br />3'-2"
<br />03'-0" 6'-8"C 2 INTERIOR HOLLOW
<br />4'-0"3'-0"3 22'-8"
<br />D
<br />6'-0" 6'-8"0 1 SLIDING VINYL FRAMEE
<br />02'-6" 6'-8" 4 INTERIOR HOLLOW
<br />CLOSET
<br />LIVING ROOM
<br />BATHROOM
<br />KITCHEN
<br />CL
<br />O
<br />S
<br />E
<br />T
<br />BATHROOM
<br />BEDROOM 1
<br />MASTER
<br />BEDROOM
<br />12'-4"5'
<br />12'8'
<br />4'
<br />12'-10"
<br />5'-2"
<br />2'-5"
<br />6'-10"
<br />2'-11"
<br />3'-3"
<br />5'-2"
<br />4'
<br />7'
<br />4'11'-6"
<br />20'-1"
<br />2'4'-10"
<br />4'-6"
<br />8'-3"
<br />7'-1"3'-4"
<br />5'
<br />72
<br />2
<br />1
<br />
<br />G
<br />a
<br />r
<br />d
<br />e
<br />n
<br />
<br />G
<br />r
<br />o
<br />v
<br />e
<br />
<br />B
<br />l
<br />v
<br />d
<br />,
<br />
<br />G
<br />a
<br />r
<br />d
<br />e
<br />n
<br />
<br />G
<br />r
<br />o
<br />v
<br />e
<br />,
<br />
<br />#
<br />J
<br />,
<br />
<br />C
<br />A
<br />
<br />9
<br />2
<br />8
<br />4
<br />1
<br />Te
<br />l
<br />.
<br />
<br />(
<br />7
<br />1
<br />4
<br />)
<br />
<br />5
<br />6
<br />8
<br />-
<br />5
<br />4
<br />4
<br />4
<br />34
<br />1
<br />4
<br />
<br />S
<br />
<br />T
<br />I
<br />M
<br />B
<br />E
<br />R
<br />
<br />S
<br />T
<br />,
<br />
<br />U
<br />N
<br />I
<br />T
<br />
<br />#
<br />2
<br />
<br />(
<br />A
<br />D
<br />U
<br />)
<br />34
<br />1
<br />4
<br />
<br />S
<br />
<br />T
<br />I
<br />M
<br />B
<br />E
<br />R
<br />
<br />S
<br />T
<br />
<br />(
<br />S
<br />F
<br />R
<br />)
<br />SA
<br />N
<br />T
<br />A
<br />
<br />A
<br />N
<br />A
<br />.
<br />
<br />C
<br />A
<br />.
<br />
<br />9
<br />2
<br />7
<br />0
<br />7
<br />MASTER
<br />BEDROOM
<br />BEDROOM
<br />BEDROOM
<br />BEDROOM
<br />KITCHEN
<br />LIVING ROOM
<br />DINING ROOM
<br />GARAGE
<br />9'-8"
<br />ENTRY
<br />PORCH
<br />COVERED
<br />PATIO
<br />5'
<br />EXISTING WALL
<br />NEW WALL
<br />A-42
<br />A-32
<br />A-33
<br />A-34
<br />A
<br />D
<br />D
<br />B WH
<br />STACKING
<br />E
<br />1
<br />1
<br />1
<br />4
<br />3
<br />2
<br />2
<br />4
<br />3'SLIDING VINYL FRAME
<br />1'-6"2'-6"4 1 SLIDING VINYL FRAME
<br />TEMP. GLAZ
<br />11'
<br />A-41
<br />A-82
<br />A-51
<br />A-5252'-7"
<br />20'-8"
<br />23'-3"
<br />8'-1"
<br />5'-2"
<br />21'-3"
<br />25'
<br />20'-2"
<br />9'-10"
<br />20'-1"9'-9"
<br />1 ATTACHED ADU FLOOR PLAN
<br />*1-HR FIRE RATED WALL (GA WP 5513)
<br />C
<br />C
<br />1 1
<br />STACKING
<br />W/D
<br />5'-10"
<br />7'-3"
<br />4'
<br />4'
<br />*1-HR FIRE RATED WALL
<br />*1-HR FIRE RATED WALL
<br />*1-HR FIRE RATED WALL (GA WP 5513)
<br />Provide one-hour protection on the
<br />underside of eave when eaves
<br />projected into the 5-ft of fire
<br />separation distance, TYP.
<br />2'
<br />1
<br />1
<br />1
<br />11/24/25
<br />AS NOTED
<br />11.24.251 REVISIONS
<br />2'-6"
<br />3'
<br />17'-9"
<br />213"=TOTAL
<br />25% = 54"
<br />54" OK
<br />1
<br />1 1
<br />3
<br />3"
<br />1'-1"
<br />TEMP. GLAZ
<br />TEMP. GLAZ
<br />TEMP. GLAZ
<br />TEMP. GLAZ 1
<br />1
<br />1
<br />1
<br />1
<br />1
<br />1
<br />1
<br />2'-6"
<br />EG
<br />R
<br />E
<br />S
<br />S
<br />EG
<br />R
<br />E
<br />S
<br />S
<br />5'-6"
<br />3'-6"
<br />4'-1"
<br />1
<br />13'-11"
<br />13'-7"
<br />5'
<br />5'-4"4'2'
<br />6'
<br />4'
<br />3'
<br />4'
<br />4'
<br />4'
<br />4'4'
<br />2'-8"
<br />18'
<br />2'-6"
<br />5'-10"
<br />3'
<br />5'-4"
<br />9'-10"
<br />10'
<br />10'
<br />11'-11"
<br />10'10'
<br />11'
<br />29'-5"
<br />26'-3"
<br />1
<br />1
<br />1 AC/ MINI SPLIT SYSTEM
<br />W/ HEAT CONDENSER
<br /> (EFF EER/CEER= 20/EFF
<br />SEER=18) W/ 4" CONC. PAD
<br />REFER TO NOTE #14
<br />1
<br />1'-4"1'-4"
<br />2'
<br />2'-6"
<br />1'-3"
<br />1'-3"
<br />2'-6"
<br />1
<br />1
<br />STC 52
<br />INTERIOR WALL
<br />STC 52INTERIOR WALL
<br />2'-6"
<br />1'-10"
<br />Sheet: 1
<br />File: C:\Users\exoma\Downloads\W-CW-1-12 (2).pdf
<br />Missing or invalid reference
<br />30" MIN CLEAR
<br />HEAD ROOM
<br />2
<br />A7
<br />1
<br />A7
|