ROOM NAME
<br />101
<br />150 SF
<br />1
<br />A101
<br />1 CONSTRUCTION GRID LINE
<br />PROPERTY LINE
<br />CENTER LINE
<br />SETBACK LINE
<br />BUILDING SECTION REFERENCE
<br />1
<br />A101 WALL SECTION REFERENCE
<br />1
<br />A101
<br />BUILDING ELEVATION REFERENCE
<br />A101
<br />1
<br />1 1
<br />1
<br />INTERIOR ELEVATION REFERENCE
<br />INTERIOR ELEVATION REFERENCE
<br />1
<br />A101
<br />101A
<br />101
<br />1011
<br />DETAIL REFERENCE
<br />AREA DETAIL REFERENCE
<br />ELEVATION MARK
<br />ELEVATION MARK
<br />FINISH CALLOUT
<br />SEE FINISH SCHEDULE
<br />EQUIPMENT CALLOUT
<br />SEE EQUIPMENT SCHEDULE
<br />ROOM LABEL
<br />DOOR LABEL
<br />SEE DOOR SCHEDULE
<br />WINDOW LABEL
<br />SEE WINDOW SCHEDULE
<br />REVISION NUMBER
<br />RF-01
<br />1
<br />0'-0"
<br />L01
<br />0'-0"
<br />1
<br />A101
<br />1
<br />A101
<br />PROJECT
<br />COPYRIGHT LOC, INC
<br />ORIGINAL SHEET SIZE: 42" X 30"
<br />LOC
<br />ABBREVIATIONS
<br />SYMBOLS LEGEND
<br />INFO = INFORMATION
<br />INSUL = INSULATION
<br />INT = INTERIOR
<br />INV = INVERTED
<br />JST = JOIST
<br />JT = JOINT
<br />L = ANGLE
<br />MAX = MAXIMUM
<br />M B = MACHINE BOLT
<br />MECH = MECHANICAL
<br />MIN = MINIMUM
<br />MTD = MOUNTED
<br />MTL = METAL
<br />N/A = NOT APPLICABLE
<br />(N) = NEW
<br />NLG = NAILING
<br />NTS = NOT TO SCALE
<br />O C = ON CENTER
<br />OPP = OPPOSITE
<br />PLT = PLATE
<br />PSF = POUNDS PER SQUARE FOOT
<br />PSI = POUNDS PER SQUARE INCH
<br />P T = PRESSURE TREATED
<br />PTD = PAINTED
<br />PW / PLY = PLYWOOD
<br />RCP = REFLECTED CEILING PLAN
<br />REQ'D = REQUIRED
<br />RET = RETAINING
<br />SHT = SHEET(S)
<br />SHTG = SHEATHING
<br />SIM = SIMILAR
<br />SPC(G) = SPACE(ING)
<br />ST STL = STAINLESS STEEL
<br />STAGG = STAGGERED
<br />STD = STANDARD
<br />STL = STEEL
<br />STRUCT = STRUCTURE
<br />T B S = TO BE SPECIFIED
<br />TEMP = TEMPERED
<br />T G = TEMPERED GLASS
<br />TH = THICKNESS
<br />T O = TOP OF
<br />T S = TUBULAR STEEL
<br />TYP = TYPICAL(LY)
<br />U N O = UNLESS NOTED OTHERWISE
<br />V / VERT = VERTICAL(LY)
<br />V I F = VERIFY IN FIELD
<br />WD = WOOD
<br />WPF(G) = WATERPROOFING
<br />W/ = WITH
<br />∅= ROUND OR DIAMETER
<br /># = NUMBER
<br />AB = ANCHOR BOLT
<br />A B C = ALCOHOLIC BEVERAGE
<br />CONTROL
<br />ABV = ABOVE
<br />A F F = ABOVE FINISH FLOOR
<br />ALUM = ALUMINUM
<br />ARCH = ARCHITECTURAL DRAWINGS
<br />B / BOT = BOTTOM
<br />BD = BOARD
<br />BLDG = BUILDING
<br />BLK (G) = BLOCK(ING)
<br />BLW = BELOW
<br />BM = BEAM
<br />BRG = BEARING
<br />BYD = BEYOND
<br />CB = CATCH BASIN
<br />C.I.P. = CAST IN PLACE
<br />CL = CENTERLINE
<br />CLG = CEILING
<br />CLR = CLEAR
<br />C M U = CONCRETE MASONRY UNIT
<br />COL = COLUMN
<br />CONC = CONCRETE
<br />CONST = CONSTRUCTION
<br />CONT = CONTINUOUS (LY)
<br />CTR (D) = CENTER (ED)
<br />D / DIAM = DIAMETER
<br />DBL = DOUBLE
<br />DET = DETAIL
<br />DIM = DIMENSION
<br />DWG (S) = DRAWING(S)
<br />(E) = EXISTING
<br />EA = EACH
<br />E E = EACH END
<br />E F = EACH FACE
<br />EL / ELEV = ELEVATION
<br />ELECT = ELECTRICAL (DWGS)
<br />EQ = EQUAL
<br />E S = EACH SIDE
<br />E W = EACH WAY
<br />EXT = EXTERIOR
<br />F B = FLAT BLOCKING
<br />FDN = FOUNDATION
<br />FIN = FINISH
<br />FLR = FLOOR
<br />F O W = FACE OF WALL
<br />FRMG = FRAMING
<br />FTG = FOOTING
<br />GA = GAUGE
<br />GALV = GALVANIZED
<br />GEN = GENERAL
<br />GR = GRADE
<br />GSM = GALVANIZED SHEET METAL
<br />GWB = GYPSUM WALLBOARD
<br />GYP = GYPSUM
<br />HC = HANDICAPPED
<br />HDR = HEADER
<br />HGR = HANGER
<br />HT = HEIGHT
<br />GENERAL NOTES
<br />CLIENT
<br />ARCHITECT
<br />CONSULTANTS
<br />COORDINATION AND VERIFICATION
<br />FIRE CODE NOTES
<br />PREPARED UNDER THE SUPERVISION OF:
<br />ALI JEEVANJEE
<br />LOC ARCHITECTS DATE
<br />REVIEWED FOR CONSTRUCTABILITY:
<br />SEAN THOMAS
<br />PRINCIPAL CIVIL ENGINEER
<br />RCE NO.: 80470
<br />DATE
<br />RECOMMENDED FOR CONSTRUCTION:
<br />JASON GABRIEL
<br />PRINCIPAL CIVIL ENGINEER
<br />RCE NO.: 62968
<br />DATE
<br />3/28/2025 6:04:06 PM
<br />2308
<br />G0.3
<br />GENERAL
<br />NOTES
<br />MARCH 28, 2025
<br />PLAN CHECK
<br />SUBMITTAL 02
<br />SANTA ANA ZOO
<br />1821 & 1823 E CHESTNUT AVE, SANTA
<br />ANA, CA 92701
<br />KPFF
<br />STRUCTURAL ENGINEER
<br />LOC ARCHITECTS
<br />KPFF
<br />CIVIL ENGINEER
<br />BORDER
<br />LANDSCAPE ARCHITECT
<br />ABRARI AND ASSOCIATES
<br />MEP ENGINEER
<br />ASSOCIATED SOILS ENGINEERING
<br />GEOTECHNICAL ENGINEER
<br />700 S. FLOWER, SUITE 2100
<br />LOS ANGELES, CA 90017
<br />213 372 5111
<br />Ramzi.hodali@kpff.com
<br />700 S. FLOWER, SUITE 2100
<br />LOS ANGELES, CA 90017
<br />213 372 5111
<br />Sharad.Ganju@kpff.com
<br />724 S. SPRING ST, SUITE 701
<br />LOS ANGELES, CA 90014
<br />213 372 5111
<br />Darren@border-la.com
<br />1713 S. STANDARD AVE
<br />GLENDALE, CA 91201
<br />818 956 1900
<br />Telma@abrari.com
<br />2860 WALNUT AVE.
<br />SIGNAL HILL, CA 90755
<br />562 897 2749
<br />Ted@associatedsoils.com
<br />3203 E. 4TH ST
<br />LOS ANGELES, CA 90063
<br />213 537 0480
<br />Office@loc-arch.com
<br />1801 E. CHESTNUT AVE.
<br />SANTA ANA, CA 92701
<br />714 647 6575
<br />Efisher@santa-ana.org
<br />SANTA ANA ZOO
<br />EDUCATION HUB
<br />MARCH 28, 2025
<br />25
<br />1. CONTRACTOR TO COMPLY WITH CODES, LAWS, ORDINANCES, RULES, AND
<br />REGULATIONS OF PUBLIC AUTHORITIES GOVERNING THE WORK.
<br />
<br />2. CONTRACTOR TO OBTAIN AND PAY FOR PERMITS AND INSPECTIONS REQUIRED BY
<br />PUBLIC AUTHORITIES GOVERNING THE WORK.
<br />
<br />3. CONTRACTOR TO REVIEW DOCUMENTS, VERIFY DIMENSIONS AND FIELD CONDITIONS
<br />AND CONFIRM THAT WORK IS BUILDABLE AS SHOWN. REPORT ANY CONFLICTS OR
<br />OMISSIONS TO THE ARCHITECT FOR CLARIFICATION PRIOR TO PERFORMING ANY WORK
<br />IN QUESTION.
<br />
<br />4. FOR SUBSTITUTIONS REFER TO SPECIFICATIONS.
<br />
<br />5. CONTRACTOR TO COORDINATE WORK WITH THE SANTA ANA ZOO, INCLUDING
<br />SCHEDULING TIME AND LOCATIONS FOR DELIVERIES, BUILDING ACCESS, USE OF
<br />BUILDING SERVICES AND FACILITIES, AND USE OF ELEVATORS. COORDINATE WORK
<br />WITH OTHER CONTRACTS. MINIMIZE DISTURBANCE OF BUILDING FUNCTIONS AND
<br />OCCUPANTS, INCLUDING TRASH REMOVAL ACCESS.
<br />
<br />6. CONTRACTOR TO COORDINATE TELECOMMUNICATIONS, DATA AND SECURITY SYSTEM
<br />INSTALLATIONS.
<br />
<br />7. CONTRACTOR TO MAINTAIN EXITS, EXIT LIGHTING, FIRE PROTECTIVE DEVICES, AND
<br />ALARMS IN CONFORMANCE WITH CODES AND ORDINANCES.
<br />
<br />8. CONTRACTOR TO PROTECT AREA OF WORK AND ADJACENT AREAS FROM DAMAGE.
<br />G.C. TO COORDINATE TRASH ACCESS.
<br />
<br />9. CONTRACTOR TO MAINTAIN WORK AREAS SECURE AND LOCKABLE DURING
<br />CONSTRUCTION.
<br />
<br />10. DO NOT SCALE DRAWINGS. DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALES
<br />SHOWN ON DRAWINGS. GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS,
<br />GRADES AND CONDITIONS AT SITE PRIOR TO COMMENCING THE WORK, AND REPORT
<br />ANY DISCREPANCIES TO THE CONSTRUCTION MANAGER AND ARCHITECT IN WRITING.
<br />
<br />11. PARTITIONS ARE DIMENSIONED FROM FINISH FACE TO FINISH FACE, UNLESS
<br />OTHERWISE NOTED. MAINTAIN DIMENSIONS MARKED "CLEAR". ALLOW FOR THICKNESS
<br />OF FINISHES.
<br />
<br />12. FLOOR LEVELS INDICATED ON DRAWINGS ARE FOR REFERENCE ONLY. PRIOR TO
<br />CONSTRUCTION GENERAL CONTRACTOR SHALL HIRE A THIRD PARTY LICENSED
<br />SURVEYOR TO FIELD VERIFY EXISTING GRADES AND FLOOR ELEVATIONS INDICATED ON
<br />DRAWING. NOTIFY THE ARCHITECT AND THE SANTA ANA ZOO REPRESENTATIVE
<br />IMMEDIATELY OF ANY DISCREPANCIES.
<br />
<br />13. WHERE EXISTING ACCESS PANELS CONFLICT WITH CONSTRUCTION. CONTRACTOR TO
<br />RELOCATE PANELS TO ALIGN WITH AND FIT WITHIN NEW CONSTRUCTION.
<br />
<br />14. CONTRACTOR TO UNDERCUT DOORS TO CLEAR TOP OF FLOOR FINISHES BY 1/4 INCH,
<br />UNLESS OTHERWISE NOTED.
<br />
<br />15. CEILING HEIGHT DIMENSIONS ARE TO FINISHED SURFACES.
<br />
<br />16. CONTRACTOR SHALL PROVIDE CONSTRUCTION BARRICADES OR FENCING AS
<br />REQUIRED AND AS APPROVED BY THE SANTA ANA ZOO FOR PUBLIC SAFETY PRIOR TO
<br />COMMENCING THE WORK.
<br />
<br />17. CONTRACTOR TO COORDINATE AND PROVIDE BACKING FOR MILLWORK AND ITEMS
<br />ATTACHED OR MOUNTED TO WALLS OR CEILINGS.
<br />
<br />18. FIRE PROTECTION EQUIPMENT AND SERVICE ACCESS MUST BE PROVIDED DURING THE
<br />CONSTRUCTION PERIOD AS REQUIRED BY THE SANTA ANA ZOO.
<br />
<br />19. CONTRACTOR SHALL PROVIDE TEMPORARY EXIT SIGNS TO ASSURE A MEANS OF EGRESS
<br />DURING CONSTRUCTION.
<br />
<br />20. WHERE A TYPICAL CONDITION IS DETAILED, IT SHALL BE UNDERSTOOD THAT ALL LIKE
<br />OR SIMILAR CONDITIONS ARE THE SAME UNLESS SPECIFICALLY NOTED OR DETAILED
<br />OTHERWISE.
<br />21. GENERAL CONTRACTOR SHALL COORDINATE SITE PLUMBING,DRAINAGE, ELECTRICAL,
<br />TELEPHONE WORK AND EXISTING UTILITIES TO PROVIDE A COMPLETE OPERATING
<br />SYSTEM.
<br />22. EXCEPT WHERE SHOWN IN DIMENSIONAL DETAIL, THE LOCATIONS OF PLUMBING,
<br />MECHANICAL EQUIPMENT, DUCTS, PIPING, AND FITTING ARE ONLY APPROXIMATE. THE
<br />EXACT LOCATIONS SHALL BE DETERMINED BY THE CONTRACTOR, SUBJECT TO
<br />APPROVAL BY THE SANTA ANA ZOO REPRESENTATIVE.
<br />
<br />23. CONTRACTOR SHALL PROVIDE AND INSTALL ALL STIFFENERS, BRACING, BLOCKING,
<br />BACK-UP PLATES AND SUPPORTING BRACKETS REQUIRED FOR THE INSTALLATION OF ALL
<br />CASEWORK, TOILET ROOM ACCESSORIES, FIXTURES AND PARTITIONS AND ALL WALL
<br />MOUNTED OR SUSPENDED MECHANICAL, ELECTRICAL OR MISCELLANEOUS EQUIPMENT
<br />AND FURNISHINGS.
<br />
<br />24. MECHANICAL SUPPLY AND RETURN AIR SHAFTS SHALL BE AIRTIGHT AND SEALED.
<br />
<br />25. ALL WORK PERFORMED SHALL COMPLY WITH THE CONTRACT DOCUMENTS, DRAWINGS
<br />AND SPECIFICATIONS, INCLUDING THESE GENERAL NOTES. THE CONTRACTOR SHALL
<br />COORDINATE THE INTENT OF THE GENERAL NOTES WITH ALL TRADES.
<br />
<br />26. SPECIFICATIONS, BOUND SEPARATELY, ARE PART OF THE CONTRACT DOCUMENTS.
<br />
<br />27. THE ORGANIZATION OF THE DRAWINGS AND SPECIFICATIONS SHALL NOT CONTROL
<br />THE CONTRACTOR IN DIVIDING THE WORK AMONG SUBCONTRACTORS OR IN
<br />ESTABLISHING THE EXTENT OF WORK TO BE PERFORMED BY ANY TRADE.
<br />
<br />28. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE DRAWINGS AND
<br />SPECIFICATIONS. IF CONFLICT IS FOUND BETWEEN DRAWINGS, GENERAL NOTES AND
<br />SPECIFICATIONS, CONSULT THE ARCHITECT FOR CLARIFICATION BEFORE PROCEEDING
<br />WITH THE WORK.
<br />
<br />29. NO DEVIATION FROM CONTRACT DRAWINGS AND SPECIFICATIONS SHALL BE MADE
<br />WITHOUT WRITTEN APPROVAL OF THE ARCHITECT.
<br />
<br />30. DOORS OPENING INTO REQUIRED 1-HOUR, FIRE-RESISTIVE CORRIDORS SHALL BE
<br />PROTECTED WITH A SMOKE OR DRAFT STOP ASSEMBLY HAVING A 20-MINUTE RATING
<br />AND SHALL BE SELF-CLOSING.
<br />
<br />31. 20-MINUTE DOOR JAMBS TO BE TIGHT-FITTING, SMOKE AND DRAFT CONTROLLED.
<br />
<br />32. EXIT DOORS SHALL SWING IN THE DIRECTION OF TRAVEL WHEN SERVING 50 OR MORE
<br />PERSONS AND IN ANY HAZARDOUS AREA.
<br />
<br />33. PROVIDE FIRE DAMPERS OR DOORS WHERE AIR DUCTS PENETRATE FIRE-RATED WALLS OR
<br />CEILINGS.
<br />
<br />34. WOOD BLOCKING SHALL BE FIRE TREATED IN ACCORDANCE WITH APPLICABLE CODE
<br />REQUIREMENTS.
<br />
<br />35. IF THE SPACE ABOVE THE SUSPENDED CEILING IS USED AS A RETURN AIR PLENUM, THEN
<br />ALL EQUIPMENT AND WIRING(COMMUNICATION, POWER ETC) SHALL BE LISTED FOR
<br />INSTALLATION IN A PLENUM.
<br />
<br />36. ALL FLEXIBLE AIRDUCTS, IF USED, SHALL MEET THE REQUIREMENTS OF NFPA 90A, 2-3-2
<br />IN CONSTRUCTION AND INSTALLATION.
<br />
<br />37. PROVIDE ALL ACCESS PANELS REQUIRED FOR ALL JUNCTION BOXES, VALVES,
<br />CLEANOUTS, PLUGS, FILTERS, EQUIPMENT AND ALL OTHER ITEMS REQUIRING SERVICE
<br />AND MAINTENANCE.
<br />38. PENETRATIONS IN WALLS REQUIRING PROTECTED OPENINGS MUST BE FIRESTOPPED
<br />WITH AN APPROVED MATERIAL IN ACCORDANCE WITH CBC SECTION 714. SPACE
<br />BETWEEN PENETRATING MATERIALS (DESCRIBED BELOW) MUST BE DESIGNED TO
<br />PREVENT THE MOVEMENT OF HOT FLAME OR GASES
<br />A. STEEL, COPPER OR FERROUS PIPES OR CONDUITS MAY PENETRATE CONCRETE OR
<br />MASONRY WALLS WHERE THE PENETRATING ITEM IS A MAXIMUM 6-INCH DIAMETER AND
<br />THE AREA OF THE OPENING THROUGH THE WALL DOES NOT EXCEED 144 SQUARE
<br />INCHES.
<br />B. MEMBRANE PENETRATIONS OF MAXIMUM 2-HR. FIRE-RESISTANCE RATED WALL AND
<br />PARTITIONS BY STEEL ELECTRICAL OUTLET BOXES NOT EXCEEDING 16 SQUARE INCHES
<br />ARE PERMITTED PROVIDED OPENINGS DO NOT EXCEED 100 SQUARE INCHES FOR ANY
<br />100 SQUARE FEET OF WALL AREA. OUTLET BOXES ON OPPOSITE SIDES OF WALLS OR
<br />PARTITIONS MUST BE SEPARATED BY A HORIZONTAL DISTANCE OF 24 INCHES.
<br />C. WHERE WALLS ARE PENETRATED BY OTHER MATERIALS OR WHERE LARGER OPENINGS
<br />ARE REQUIRED THAN PERMITTED IN (B) ABOVE, THEY MUST BE QUALIFIED BY TESTS
<br />CONDUCTED IN ACCORDANCE WITH SECTION.
<br />39. SMOKE AND FIRE DAMPERS MUST BE INSTALLED IN THE FOLLOWING LOCATIONS PER
<br />CBC SECTION 717
<br />A. DUCT PENETRATIONS OF FIRE WALLS IN ACCORDANCE TO SECTION
<br />B. DUCT PENETRATIONS OF FIRE BARRIERS, EXCEPT EXIT ENCLOSURES AND EXIT
<br />PASSAGEWAYS WHERE THEY ARE NOT ALLOWED TO PENETRATE.
<br />C. DUCTS PENETRATING SHAFTS.
<br />D. DUCTS PENETRATING FIRE PARTITIONS AND FIRE-RATED CORRIDOR WALLS. SEE
<br />EXCEPTION FOR STEEL DUCTS WITH NO OPENINGS INTO CORRIDOR
<br />E. DUCTS PENETRATING SMOKE BAFFLERS
<br />F. DUCTS PENETRATING HORIZONTAL ASSEMBLIES
<br />40. INTERIOR FINISH MATERIALS APPLIED TO WALL AND CEILINGS SHALL BE TESTED AS
<br />SPECIFIED IN SECTION 803. SPECIFY THE CLASSIFICATIONS PER TABLE 803.1.2.
<br />41. ALL EXIT DOORS SHALL COMPLY WITH CBC SECTION 1010
<br />A. CLEAR WIDTH OF EACH DOOR OPENING SHALL BE MIN. 32" OR PER CBC SECTION
<br />1005, WHICHEVER IS GREATER
<br />B. MIN. DOOR HEIGHT OF 6'-8"
<br />C. SHALL BE CAPABLE OF OPENING 90 DEGREES.
<br />D. THE MAXIMUM WIDTH OF A SWINGING DOOR LEAF SHALL BE 48" NOMINAL.
<br />E. EXIT DOOR SHALL BE SIDE-HINGED SWINGING TYPE.
<br />42. BUILDING SHALL COMPLY WITH BUILDING SAFETY REGULATONS, SANTA ANA
<br />MUNICIPAL CODE CHAPTER 8 DIVISION 3.
<br />1. STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING DRAWINGS AND SPECIFICATIONS
<br />ARE SUPPLEMENTARY TO THE ARCHITECTURAL DRAWINGS, BUT TOGETHER WITH THE
<br />ARCHITECTURAL DRAWINGS FORM THE PROJECT DOCUMENTS. IT IS THE
<br />RESPONSIBILITY OF THE CONTRACTOR TO COMPLY WITH AND COORDINATE WITH THE
<br />ARCHITECTURAL DRAWINGS. BEFORE THE INSTALLATION OF STRUCTURAL,
<br />MECHANICAL, ELECTRICAL AND PLUMBING WORK. SHOULD THERE BE A DISCREPANCY
<br />DISCOVERED BETWEEN THE ARCHITECTURAL DRAWINGS AND THE CONSULTANT
<br />ENGINEER'S DRAWINGS, IT SHALL BE BROUGHT TO THE ARCHITECT AND THE SANTA
<br />ANA ZOO REPRESENTATIVE'S ATTENTION FOR CLARIFICATION PRIOR TO INSTALLATION.
<br />CONTRACTOR SHALL NOT, EITHER KNOWINGLY OR IF HE SHOULD HAVE KNOWN
<br />BASED ON INFORMATION CONTAINED IN THE CONTRACT DOCUMENTS, INSTALL
<br />WORK IN CONFLICT WITH THE ARCHITECTURAL DRAWINGS. ANY SUCH WORK SHALL
<br />BE CORRECTED BY THE CONTRACTOR AT HIS EXPENSE AND AT NO ADDITIONAL COST
<br />TO THE SANTA ANA ZOO.
<br />2. DO NOT SCALE DRAWINGS. CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATION
<br />AND ALL EXISTING CONDITIONS AT THE SITE BEFORE COMMENCING WORK AND
<br />REPORT ANY DISCREPANCIES TO THE ARCHITECT AND THE SANTA ANA ZOO
<br />REPRESENTATIVE PRIOR TO THE START OF THE WORK.
<br />3. IN THE EVENT OF CONFLICT BETWEEN THE DRAWING AND SPECIFICATIONS, OR WITHIN
<br />THEMSELVES, THE ARCHITECT WILL IN CONSULTATION WITH THE SANTA ANA ZOO
<br />DETERMINE WHICH CONFLICTING REQUIREMENT GOVERNS.
<br />4. SPECIFIC NOTES OR KEYNOTES ON DETAILS APPLY TO SIMILAR CONDITIONS ON OTHER
<br />DETAILS ON ALL DRAWINGS, UNLESS SPECIFICALLY NOTED OTHERWISE.
<br />5. ALL MANUFACTURED MATERIALS USED SHALL BEAR THE APPROPRIATE U.L. LABELS.
<br />CONTRACTOR ARE TO VERIFY DIMENSIONS, ELEVATIONS AND EXISTING CONDITIONS
<br />AT THE SITE BEFORE COMMENCING WORK AND REPORT DISCREPANCIES TO THE
<br />ARCHITECT AND THE SANTA ANA ZOO REPRESENTATIVE FOR RESOLUTION PRIOR TO
<br />THE START OF THE WORK. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CHECKING
<br />EXISTING JOB SITE CONDITIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR
<br />CHECKING ALL DIMENSIONS AND CONDITIONS AT THE JOB SITE WHICH SHOULD
<br />CHANGE THE AESTHETIC INTENT OR HINDER PROPER WORK COMPLETIONS BEFORE
<br />FABRICATING ANY MATERIAL AND SHALL REPORT ANY DISCREPANCIES TO THE SANTA
<br />ANA ZOO REPRESENTATIVE.
<br />6. VERIFY SIZES AND LOCATIONS OF ALL MECHANICAL EQUIPMENT SIZES, EQUIPMENT
<br />PADS AND BASES REQUIREMENTS, AS WELL AS POWER AND WATER OR DRAIN
<br />INSTALLATIONS WITH EQUIPMENT MANUFACTURERS BEFORE PROCEEDING WITH THE
<br />WORK. CHANGES TO ACCOMMODATE FIELD CONDITIONS OR SUBSTITUTIONS SHALL
<br />BE MADE WITHOUT ADDITIONAL COST TO THE SANTA ANA ZOO REPRESENTATIVE.
<br />7. VERIFY ALL OPENINGS IN THE FIELD PRIOR TO THE FABRICATION OF DOORS AND
<br />FRAMES.
<br />8. PROVIDE AND COORDINATE THE EXACT DIMENSIONS, SIZES, AND POSITIONS OF
<br />OPENINGS IN SLABS AND WALLS NECESSARY FOR THE INSTALLATION OF THE WORK.
<br />9. VALVES, CONTROLS AND TERMINATION SHALL BE POSITIONED FOR SAFE, DIRECT AND
<br />EASY ACCESS. PIPING AND DUCTWORK SHALL BE INSTALLED FOR CONVENIENT FUTURE
<br />ADDITIONS AND MODIFICATIONS.
<br />10. VERIFY AND COORDINATE SIZES, LOCATIONS AND CHARACTERISTICS OF ALL WORK
<br />AND EQUIPMENT TO BE FURNISHED BY OTHERS, WITH THE MANUFACTURER OR
<br />SUPPLIER BEFORE ANY CONSTRUCTION.
<br />11. CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATELY BRACING AND PROTECTING
<br />ALL WORK DURING CONSTRUCTION AGAINST DAMAGE, BREAKAGE, COLLAPSE AND
<br />MISALIGNMENT ACCORDING TO APPLICABLE CODES, STANDARDS AND GOOD
<br />CONSTRUCTION PRACTICES.
<br />12. THE CONTRACTOR IS TO BE RESPONSIBLE FOR CLEANUP OF ALL TRADES AND REMOVAL
<br />OF ALL DEBRIS. THE COMPLETED WORK SHALL BE LEFT CLEAN AND READY FOR
<br />OCCUPANCY.
<br />13. CONTRACTOR SHALL CORRECT ANY DAMAGE CREATED BY THE CONTRACTOR OR ANY
<br />OR THE CONTRACTOR'S SUBCONTRACTORS.
<br />14. FURNISH AND INSTALL EXPANSION JOINTS, CONTROL JOINTS, ETC. WHETHER OR NOT
<br />DOCUMENTED. COORDINATE WITH FINAL LOCATION OF THESE ITEMS WITH THE SANTA
<br />ANA ZOO REPRESENTATIVE PRIOR TO COMMENCING WORK.
<br />FIRE PROTECTION
<br />1. PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A OR 2-
<br />A10BC WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF THE BUILDING; ALSO
<br />DURING CONSTRUCTION. REFER TO PLANS FOR LOCATIONS
<br />2. PROVIDE ADDITIONAL FIRE EXTINGUISHERS AS REQUIRED BY THE ORANGE COUNTRY
<br />FIRE AUTHORITY FIRE MARSHALL
<br />3. THIS BUILDING MUST BE EQUIPPED WITH AN AUTOMATIC FIRE EXTINGUISHING SYSTEM,
<br />COMPLYING WITH (NFPA-13); THE SPRINKLER SYSTEM SHALL BE APPROVED BY SANTA
<br />ANA ZOO BUILDING OFFICIAL PRIOR TO INSTALLATION.
<br />MEANS OF EGRESS
<br />1. TWO EXITS ARE REQUIRED FROM EACH SPACE OR STORY. (T 1006.2.1)
<br />A. OCCUPANT LOAD > 49, (A, *B, E, F, M, U)
<br />B. OCCUPANT LOAD > 10, (R)
<br />C. OCCUPANT LOAD > 29, (S)
<br />D. COMMON PATH OF EGRESS > 75 FT.
<br />E. COMMON PATH OF EGRESS > 100 FT. (B, F, S) SPRINKLERED BUILDING
<br />* > 29 (B)
<br />2. ALL EXIT DOORS SHALL COMPLY WITH SECTION 1010.1
<br />A. CLEAR WIDTH OF EACH DOOR OPENING SHALL BE MIN. 32 ”OR PER 1005.3.2,
<br />WHICHEVER IS GREATER
<br />B. MIN. DOOR HEIGHT IS 6’-8”
<br />C. SHALL BE CAPABLE OF OPENING 90 DEGREES
<br />D. THE MAXIMUM WIDTH OF A SWINGING DOOR LEAF SHALL BE 48 ”NOMINAL
<br />E. EXIT DOOR SHALL BE SIDE-HINGED SWINGING TYPE
<br />3. PANIC HARDWARE SHALL BE PROVIDED ON EXIT DOORS HANDLING AN OCCUPANT
<br />CAPACITY OF 50 OR MORE PERSONS, FROM ANY GROUP A, E OR I OCCUPANCY; AND
<br />FOR H1, 2, 3, 6, 7,8 OCCUPANCY AND SOUND STAGES. ONLY PANIC HARDWARE
<br />APPROVED AND LISTED BY THE CAMPUS FIRE MARSHALL SHALL BE INSTALLED.
<br />4. PROVIDE A 1 HR. FIRE RATED CORRIDOR IN ACCORDANCE WITH CBC SECTION 1020.
<br />A. OCCUPANT LOAD > 30
<br />B. OCCUPANT LOAD > 10
<br />C. R OCCUPANCIES
<br />D. E OCCUPANCIES
<br />E. I OCCUPANCIES
<br />F. H OCCUPANCIES
<br />5. ALL ELECTRICAL ROOM DOORS SHALL BE 60 MINUTES. MAGNETIC HOLD OPENS SHALL
<br />BE USED WHERE ELECTRICAL ROOM DOORS OCCUR WITHIN AN ELEVATOR LOBBY.
<br />6. PROVIDE A MINIMUM CORRIDOR WIDTH OF 44 INCHES OR PER 1005.3.2, WHICHEVER IS
<br />GREATER (T 1020.2).
<br />7. FLOORS OR LANDINGS ON EACH SIDE OF DOORS TO HAVE THE SAME ELEVATION.
<br />LANDINGS SHALL BE LEVEL EXCEPT FOR EXTERIOR LANDINGS (MAX. 2% SLOPE) (CBC
<br />SECTION 1010).
<br />8. SPACES BETWEEN TWO DOORS IN SERIES SHALL BE A MIN. 48 ”PLUS THE WIDTH OF THE
<br />DOOR SWINGING INTO THE SPACE. (CBC SECTION 1010)
<br />9. WHERE TWO OR MORE EXITS ARE REQUIRED, AT LEAST TWO EXITS MUST BE SEPARATED
<br />BY 1/2 THE MAX. DIAGONAL LENGTH OF THE AREA SERVED OR 1/3 THE MAX.
<br />DIAGONAL IF SPRINKLERED (CBC SECTION 1010)
<br />10. LANDING WIDTH AT DOORS MUST HAVE A MIN. CLEAR DIMENSION OF DOORS SERVED.
<br />MIN. LENGTH OF SUCH LANDINGS IS 44" (36") (CBC SECTION 1010)
<br />11. THE MEANS OF EGRESS SYSTEM MUST HAVE A CLEAR CEILING HEIGHT OF 7'-6. (CBC
<br />SECTION 1003)
<br />12. FIRE-RATED ASSEMBLIES SHALL BE PER CBC SECTION 721, GENERIC ASSEMBLIES OF
<br />GYPSUM HANDBOOK OR ICC APPROVAL
<br />NO.DESCRIPTION DATE
<br />3 PC01 CORRECTIONS 03/28/25
<br />3
|