My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
625 S Cypress Ave - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Cypress Ave
>
625 S Cypress Ave
>
625 S Cypress Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 11:14:09 AM
Creation date
2/24/2026 11:13:50 AM
Metadata
Fields
Template:
Plan
Permit Number
20183537
30147573
40139358
101120230
Full Address
625 S Cypress Ave
Street Number
625
Street Direction
S
Street Name
Cypress
Street Suffix
Ave
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
335
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
REFLECTED CEILING PLAN GENERAL NOTES <br />1. REFER TO ADDITIONAL NOTES ON SHEET T0.01. <br />2. CONTRACTOR SHALL VERIFY THAT (E) CONDITIONS ARE AS INDICATED ON THE DRAWINGS. <br />NOTIFY THE ARCHITECT IMMEDIATELY OF VARIATIONS OR DISCREPANCIES. DO NOT PROCEED <br />WITH AFFECTED WORK UNTIL THE VARIATIONS OR DISCREPANCIES ARE RESOLVED BY THE <br />ARCHITECT. <br />3. PROTECT ALL EXISTING ITEMS THAT ARE TO REMAIN. RESTORE ALL SURROUNDING AREAS <br />AFFECTED BY THE WORK. <br />4. ALL DIMENSIONS SHALL BE VERIFIED IN THE FIELD. DIMENSIONS ARE TO FACE OF FINISHED <br />WALL, U.O.N. DIMENSIONS OF (E) CONDITIONS ARE FOR REFERENCE ONLY AND SHALL BE <br />VERIFIED BY THE CONTRACTOR IN THE FIELD. WHERE NO DIMENSION IS PROVIDED CONSULT <br />WITH THE ARCHITECT FOR CLARIFICATION BEFORE PROCEEDING WITH AFFECTED WORK. <br />5. CONTRACTOR SHALL VERIFY "CENTERLINE" AND "MATCHLINE" ALIGNMENTS OF ALL <br />ARCHITECTURAL ELEMENTS. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY <br />DISCREPANCIES BEFORE PROCEEDING. <br />6. PROVIDE CEILING ACCESS AS INDICATED AND/OR AS REQUIRED FOR EQUIPMENT MAINTENANCE. <br />VERIFY MANUFACTURER RECOMMENDATIONS. <br />7. CONTRACTOR TO COORDINATE THE WORK OF ALL TRADES TO MAINTAIN SCHEDULED CEILING <br />HEIGHTS AND REQUIRED CLEARANCES FOR FIXTURES, DUCTS, SUSPENSION SYSTEMS, PIPING, <br />ETC. <br />8. CONTRACTOR TO COORDINATE FIXTURE LOCATIONS WITH ALL (E) AND NEW CEILING FRAMING. <br />NOTIFY ARCHITECT OF ANY VARIATIONS OR DISCREPANCIES IN LOCATIONS SHOWN PRIOR TO <br />PROCEEDING. <br />PLAN LEGEND <br />EXIT SIGNAGE AND EGRESS ILLUMINATION NOTES KEYNOTES <br />1. EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED. EXIT SIGNS ILLUMINATED BY AN <br />EXTERNAL SOURCE SHALL HAVE AN INTENSITY OF NOT LESS THAN 5 FOOT CANDLES (54 IUX). <br />INTERNALLY ILLUMINATED SIGNS SHALL BE LISTED AND LABELED AND SHALL BE INSTALLED IN <br />ACCORDANCE WITH THE MANUFACTURER’S INSTRUCTIONS AND CBC SECTION 2702. <br />2. EXIT SIGNS SHALL BE ILLUMINATED AT ALL TIMES. (CBC SECTION 1013.3) <br />3. EXIT SIGNS SHALL BE CONNECTED TO AN EMERGENCY POWER SYSTEM THAT WILL PROVIDE AN <br />ILLUMINATION OF NOT LESS THAN 90 MINUTES IN CASE OF PRIMARY POWER LOSS. (CBC <br />SECTION 1013.6.3) <br />4. THE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE, SHALL BE ILLUMINATED AT ALL TIMES <br />THE BUILDING SPACE SERVED BY THE MEANS OF EGRESS IS OCCUPIED. <br />5. THE MEANS OF EGRESS ILLUMINATION LEVEL SHALL NOT BE LESS THAN 1 FOOT-CANDLE AT THE <br />WALKING SURFACE. <br />6. THE POWER SUPPLY FOR MEANS OF EGRESS ILLUMINATION SHALL NORMALLY BE PROVIDED BY <br />THE PREMISES’ELECTRICAL SUPPLY. IN THE EVENT OF POWER SUPPLY FAILURE, AN <br />EMERGENCY ELECTRICAL SYSTEM SHALL AUTOMATICALLY ILLUMINATE THE FOLLOWING AREAS: <br />A. AISLES AND UNENCLOSED EGRESS STAIRWAYS IN ROOMS AND SPACES THAT REQUIRE <br />TWO OR MORE MEANS OF EGRESS. <br />B. CORRIDORS, EXIT ENCLOSURES AND EXIT PASSAGEWAYS IN BUILDINGS REQUIRED TO <br />HAVE TWO OR MORE EXITS. <br />C. EXTERIOR EGRESS COMPONENTS AT OTHER THAN THE LEVEL OF EXIT DISCHARGE UNTIL <br />EXIT DISCHARGE IS ACCOMPLISHED FOR BUILDINGS REQUIRED TO HAVE TWO OR MORE <br />EXITS. <br />D. INTERIOR EXIT DISCHARGE ELEMENTS, AS PERMITTED IN CBC SECTION 1028.1, IN <br />BUILDINGS REQUIRED TO HAVE TWO OR MORE EXITS. <br />E. EXTERIOR LANDINGS, AS REQUIRED BY CBC SECTION 1010.1.6, FOR EXIT DISCHARGE <br />DOORWAYS IN BUILDINGS REQUIRED TO HAVE TWO OR MORE EXITS. <br />7. THE EMERGENCY POWER SYSTEM SHALL PROVIDE POWER FOR A DURATION OF NOT LESS THAN <br />90 MINUTES AND SHALL CONSIST OF STORAGE BATTERIES, UNIT EQUIPMENT OR AN ON-SITE <br />GENERATOR. THE INSTALLATION OF THE EMERGENCY POWER SYSTEM SHALL BE IN <br />ACCORDANCE WITH CBC SECTION 2702. <br />8. EMERGENCY LIGHTING FACILITIES SHALL BE ARRANGED TO PROVIDE INITIAL ILLUMINATION THAT <br />IS AT LEAST AN AVERAGE OF 1 FOOT-CANDLE (11 LUX) AND A MINIMUM AT ANY POINT OF 0.1 <br />FOOT-CANDLE (1 LUX) MEASURED ALONG THE PATH OF EGRESS AT FLOOR LEVEL. ILLUMINATION <br />LEVELS SHALL BE PERMITTED TO DECLINE TO 0.6 FOOT-CANDLE (6 LUX)AVERAGE AND A <br />MINIMUM AT ANY POINT OF 0.06 FOOT-CANDLE (0.6 LUX) AT THE END OF THE EMERGENCY <br />LIGHTING TIME DURATION. A MAXIMUM-TO-MINIMUM ILLUMINATION UNIFORMITY RATIO OF 40 TO 1 <br />SHALL NOT BE EXCEEDED. <br />LIGHT FIXTURE SCHEDULE <br />2x WOOD STUDS @ 16" O.C., MATCH ADJACENT WALL ASSEMBLY <br />EXISTING WOOD STUD WALL TO REMAIN <br />-NEW GYP BD SHEATHING ON INTERIOR SIDE(S) OF ALL (E) <br />WALLS, TYP. <br />-ALL EXTERIOR WALLS TO RECEIVE R-19 BATT INSULATION <br />ACT CEILING, REFER TO <br />SHEAR WALL SHEATHING, REFER TO STRUCTURAL DRAWINGS <br />2 <br />A5.04 <br />GYP. BD. CEILING, REFER TO <br />1 <br />A5.04 <br />DESIGN-BUILD MECHANICAL CATWALK REQUIRED FOR ACCESS <br />TO ALL FAN COIL UNITS FROM CEILING ACCESS POINT; FIELD <br />VERIFY LOCATION WITH (E) TRUSSES AND NEW CEILING FRAMING <br />SUPPLY AIR DIFFUSER, REFER TO MECHANICAL DRAWINGS <br />RETURN AIR GRILLE, REFER TO MECHANICAL DRAWINGS <br />TRANSFER AIR GRILLE, REFER TO MECHANICAL DRAWINGS <br />EXHAUST AIR GRILLE / EXHAUST FAN, REFER TO MECHANICAL DRAWINGS <br />WALL MOUNTED (EX1) OR CEILING SUSPENDED (EX2) ILLUMINATED EXIT SIGN. <br />EXIT SIGNS SHALL BE ILLUMINATED AT ALL TIMES FOR A DURATION OF NOT <br />LESS THAN 90 MINUTES IN CASE OF PRIMARY POWER LOSS. TO ENSURE THIS <br />CONTINUOUS ILLUMINATION, THE EXIT SIGN MUST BE CONNECTED TO AN <br />EMERGENCY POWER SYSTEM PROVIDED FROM STORAGE BATTERIES, UNIT <br />EQUIPMENT OR AN ON-SITE GENERATOR, CBC 1013.6.3. REFER TO ELECTRICAL <br />DRAWINGS <br />1 <br />A3.00 <br />1 <br />A3.01 <br />2 <br />A3.01 <br />MULTI-PURPOSE <br />ROOM A <br />02 <br />ENTRY / CHECK <br />IN OFFICE <br />01 <br />TRAINING ROOM <br />B <br />03 <br />HALLWAY <br />04 <br />TRAINING ROOM <br />C <br />05 <br />HALLWAY <br />06 <br />WOMENS <br />07 <br />MENS <br />09 <br />RESTROOM <br />11 <br />JANITOR <br />12 <br />OFFICE AND <br />BREAKROOM <br />10 <br />EQ EQ <br />2 <br />A3.00 <br />1 <br />2 <br />3 <br />A B C D E F <br />A.F.F. <br />GYP. BD. <br />8' - 11" <br />A.F.F. <br />GYP. BD. <br />8' - 11" <br />A.F.F. <br />GYP. BD. <br />8' - 11" <br />A.F.F. <br />GYP. BD. <br />9' - 11" <br />A.F.F. <br />GYP. BD. <br />9' - 11" <br />A.F.F. <br />GYP. BD. <br />9' - 11"A.F.F. <br />GYP. BD. <br />9' - 11" <br />A.F.F. <br />GYP. BD. <br />9' - 11" <br />A.F.F. <br />GYP. BD. <br />8' - 11" <br />EQ <br />EQ <br />2' - 0" <br />EQ EQ <br />EQ EQ EQ EQ <br />EQ <br />EQ <br />2' - 0" <br />2' <br /> <br />- <br /> <br />0 <br />" <br />2' - 0" <br />2' <br /> <br />- <br /> <br />0 <br />" <br />F3 <br />F1 F1 F1 F1 F1 <br />F2 <br />F2 <br />F2 <br />F3 <br />F3 <br />F4 <br />F4 <br />F5 <br />F5 <br />F12 F12 <br />F12 <br />F12 F12 <br />F6 <br />F6 <br />F6 <br />F6 <br />F6 <br />F3 <br />F3 <br />F3 <br />F2 <br />F8 <br />F7 <br />F9 F9 F9 F9 F9 F9 <br />F9 <br />F10 <br />F10 <br />F10F10F10F10F10 <br />8" <br />15 <br />' <br /> <br />- <br /> <br />8 <br />" <br />25 <br />' <br /> <br />- <br /> <br />0 <br />" <br />1' <br /> <br />- <br /> <br />3 <br />" <br />42 <br />' <br /> <br />- <br /> <br />7 <br />" <br />72' - 5"18' - 10" <br />26 <br />' <br /> <br />- <br /> <br />6 <br />" <br />14 <br />' <br /> <br />- <br /> <br />9 <br />" <br />1"7' - 1"10' - 9"7' - 3"22' - 6"23' - 7"18' - 6"7" <br />17' - 11"72' - 5" <br />F9 <br />A.F.F. <br />(E) PLASTER <br />12' - 8" <br />A.F.F. <br />GYP. BD. <br />8' - 11" <br />NO CEILING <br />EXPOSED STRUCTURE <br />12' -5" A.F.F. <br />EQ <br />EQ <br />EQ EQ <br />EQ EQ3' - 6 3/4"3' - 6" <br />06-03 <br />06-03 <br />NO CEILING <br />EXPOSED STRUCTURE <br />+7'-6" <br />+8'-0" <br />+8'-7" <br />+8'-7" <br />+8'-7" <br />+8'-7" <br />+10'-6" <br />+11'-5" <br />+10'-6" +10'-6" <br />+10'-6" <br />+10'-6" <br />+11'-5" <br />+8'-0" <br />+8'-0" <br />+8'-0" <br />+8'-0" <br />+8'-0" <br />+8'-0" <br />+8'-0" <br />+8'-0" <br />EQ EQ EQ <br />EQ EQ <br />2' - 6"2' - 6" <br />EQ EQ EQ <br />EQ EQ <br />F9 F9 <br />F9 <br />F9 <br />EQ EQ <br />F11 F11 F11 F11 <br />F13 <br />F11 F11 F11 F11 <br />F5 <br />F5 <br />EX1 EX1 <br />EX2 <br />EQ EQ <br />EQ EQ <br />EQ <br />EQ <br />EQ <br />EQ <br />5' <br /> <br />- <br /> <br />0 <br />" <br />16 <br />A5.03 <br />7' - 0" <br />16 <br />A5.03 <br />NOTE: <br />(E) TRUSSES AND NEW CEILING AND ROOF FRAMING <br />SHOWN FOR REFERENCE ONLY. REFER TO STRUCTURAL <br />DRAWINGS FOR MORE DETAIL INFORMATION. ALL (E) <br />CONDITIONS TO BE FIELD VERIFIED. <br />EQ EQ <br />EQ EQ <br />09-02 <br />09-02 <br />4' <br /> <br />- <br /> <br />0 <br />" <br />4' <br /> <br />- <br /> <br />0 <br />" <br />1' - 0" <br />+8'-0" <br />F2 <br />08-09 <br />TYP. <br />23-10 <br />05-06 <br />TYP. <br />TYP. <br />F14 <br />EX2 <br />EX1 <br />UNDER CABINET <br />LED LIGHT <br />Scale <br />Project number <br />Date <br />Drawn by <br />Jen Dunbar, AIA <br />phone: 310.435.3928 <br />12314 La Maida Street <br />Valley Village, CA 91607 <br />jen@dunbararchitecture.com <br />DUNBAR <br />ARCHITECTURE <br />JD/AP <br />As indicated <br />4/ <br />7 <br />/ <br />2 <br />0 <br />2 <br />5 <br /> <br />9 <br />: <br />2 <br />1 <br />: <br />3 <br />3 <br /> <br />P <br />M <br />A1.20 <br />REFLECTED <br />CEILING PLAN <br />23004 <br />CYPRESS CENTER <br />RESTORATION <br />CITY OF SANTA ANA <br />1/17/2025 <br />625 S. CYPRESS AVE. <br />SANTA ANA, CA 92701 <br />1/4" = 1'-0"A1.20 <br />1 REFLECTED CEILING PLAN - PROPOSED 0'8'4'4' <br />TYPE COUNT DESCRIPTION COMMENTS <br />F1 5 LARGE SCHOOLHOUSE <br />PENDANT <br />REFER TO ELECTRICAL DRAWINGS AND <br />CUT SHEETS FOR SELECTED PRODUCTS <br />F2 13 INDUSTRIAL PENDANT REFER TO ELECTRICAL DRAWINGS AND <br />CUT SHEETS FOR SELECTED PRODUCTS <br />F3 24 SUSPENDED LINEAR <br />PENDANT <br />REFER TO ELECTRICAL DRAWINGS AND <br />CUT SHEETS FOR SELECTED PRODUCTS <br />F4 2 SURFACE MOUNTED <br />EXTERIOR <br />REFER TO ELECTRICAL DRAWINGS AND <br />CUT SHEETS FOR SELECTED PRODUCTS <br />F5 4 SURFACE MOUNTED <br />INTERIOR - 17" DIAM. <br />REFER TO ELECTRICAL DRAWINGS AND <br />CUT SHEETS FOR SELECTED PRODUCTS <br />F6 7 6" RECESSED CAN <br />DOWNLIGHT <br />REFER TO ELECTRICAL DRAWINGS AND <br />CUT SHEETS FOR SELECTED PRODUCTS <br />F7 1 SMALL SCHOOLHOUSE <br />PENDANT <br />REFER TO ELECTRICAL DRAWINGS AND <br />CUT SHEETS FOR SELECTED PRODUCTS <br />F8 8 2x2 PANEL LIGHT REFER TO ELECTRICAL DRAWINGS AND <br />CUT SHEETS FOR SELECTED PRODUCTS <br />F9 12 EXTERIOR DECORATIVE <br />SCONCE <br />REFER TO ELECTRICAL DRAWINGS AND <br />CUT SHEETS FOR SELECTED PRODUCTS <br />F10 7 EXTERIOR WALL LIGHTS REFER TO ELECTRICAL DRAWINGS AND <br />CUT SHEETS FOR SELECTED PRODUCTS <br />F11 24 RECESSED 12" LINEAR REFER TO ELECTRICAL DRAWINGS AND <br />CUT SHEETS FOR SELECTED PRODUCTS <br />F12 5 CEILING FAN, PENDANT <br />MOUNTED <br />REFER TO ELECTRICAL DRAWINGS AND <br />CUT SHEETS FOR SELECTED PRODUCTS <br />F13 1 RECESSED 4" LINEAR REFER TO ELECTRICAL DRAWINGS AND <br />CUT SHEETS FOR SELECTED PRODUCTS <br />F14 1 SURFACE WALL MOUNTED REFER TO ELECTRICAL DRAWINGS AND <br />CUT SHEETS FOR SELECTED PRODUCTS <br />05-06 LADDER ACCESS TO ROOF <br />06-03 1x6 SHEATHING ABOVE GYP WALL FINISH AT EAST AND SOUTH WALLS OF MULTI-PURPOSE RM A <br />08-09 30"x30" CEILING ACCESS PANEL <br />09-02 PATCH AND REPAIR PLASTER FINISH, ALL NEW MATERIALS SHALL MATCH ORIGINAL AS CLOSE AS <br />POSSIBLE IN FINISH AND TEXTURE <br />23-10 DESIGN-BUILD MECHANICAL CATWALK REQUIRED FOR ACCESS TO ALL FAN COIL UNITS FROM <br />CEILING ACCESS POINT; FIELD VERIFY LOCATION WITH (E) TRUSSES AND NEW CEILING FRAMING <br />NOTE: REFER TO A0.00 FOR SITE LIGHTING FIXTURE SCHEDULE <br />No. Description Date <br />DESIGN DEVELOPMENT 1/12/2024 <br />75% CD 3/15/2024 <br />90% CD 5/14/2024 <br />PERMIT SET 5/17/2024 <br />OCFA SUBMITTAL 9/26/2024 <br />BACKCHECK SET 1/17/2024 <br />BACKCHECK SET_V2 4/8/2025