Laserfiche WebLink
GENERAL NOTES <br />1. REFER TO ADDITIONAL NOTES ON SHEET T0.001. <br />2. CONTRACTOR SHALL VERIFY THAT (E) CONDITIONS ARE AS INDICATED ON THE DRAWINGS. <br />NOTIFY THE ARCHITECT IMMEDIATELY OF VARIATIONS OR DISCREPANCIES. DO NOT PROCEED <br />WITH AFFECTED WORK UNTIL THE VARIATIONS OR DISCREPANCIES ARE RESOLVED BY THE <br />ARCHITECT. <br />3. RESTORE ALL SURROUNDING AREAS AFFECTED BY THE WORK. PROTECT ALL EXISTING ITEMS <br />THAT ARE TO REMAIN. <br />4. ALL DIMENSIONS SHALL BE VERIFIED IN THE FIELD. DIMENSIONS ARE TO FACE OF FINISHED WALL, <br />U.O.N. DIMENSIONS OF (E) CONDITIONS ARE FOR REFERENCE ONLY AND SHALL BE VERIFIED BY <br />THE CONTRACTOR IN THE FIELD. WHERE NO DIMENSION IS PROVIDED CONSULT WITH THE <br />ARCHITECT FOR CLARIFICATION BEFORE PROCEEDING WITH AFFECTED WORK. <br />5. WHERE ORIGINAL MATERIALS REMAIN AND ARE SALVAGEABLE, ORIGINAL MATERIALS SHALL BE <br />REPAIRED AS NEEDED. IF DETERIORATION IS BEYOND REPAIR OR ORIGINAL BUILDING FEATURES <br />ARE MISSING, ALL NEW MATERIALS SHALL MATCH ORIGINALS AS CLOSE AS POSSIBLE AND MEET <br />THE SECRETARY OF THE INTERIOR'S STANDARDS FOR REHABILITATION. <br />6. ALL DOORS AND WINDOWS PLACEMENT IS SHOWN PER THE ORIGINAL DRAWINGS AND HAVE NOT <br />BEEN VERIFIED FOR AS-BUILT LOCATIONS DUE TO THE SECURITY MEASURES IN PLACE ON THE <br />EXTERIOR OF THE BUILDING. <br />7. DOORS HAVE BEEN REMOVED AND SOME WINDOW CASING REMAINS IN SOME OF THE WINDOWS. <br />COMPLETE INTACT WINDOWS HAVE NOT BEEN VERIFIED DUE TO SECURITY MEASURES IN PLACE <br />ON SITE. <br />8. WHERE DOORS AND WINDOWS ARE NO LONGER IN PLACE, NEW WOOD DOOR AND WINDOWS ARE <br />TO BE INSTALLED TO MATCH ORIGINAL DRAWINGS. <br />9. PREP AND PAINT ALL PLASTER WALLS. PATCH AND REPAIR AREAS AS REQUIRED, FOR COST <br />ESTIMATE ASSUME 10% OF THE AREA NEEDS PATCHING. REPAIR ANY DAMAGED OR MISSING <br />MOLDINGS TO MATCH ADJACENT PROFILE. <br />10. (E) TRUSSES AND NEW CEILING AND ROOF FRAMING SHOWN FOR REFERENCE ONLY. REFER TO <br />STRUCTURAL DRAWINGS FOR MORE DETAIL INFORMATION. ALL (E) CONDITIONS TO BE FIELD <br />VERIFIED. <br />11. MECHANICAL EQUIPMENT, LIGHT FIXTURES AND UTILITY LOCATIONS TO BE COORDINATED IN THE <br />FIELD WITH (E) TRUSSES AND NEW FRAMING. <br />LEGENDKEYNOTES <br />xx <br />00 <br />WINDOW TAG, REFER TO SHEET A6.02 FOR WINDOW SCHEDULE <br />DOOR TAG, REFER TO SHEET A6.00 FOR DOOR SCHEDULE <br />LIGHT FIXTURE TAG, REFER TO SHEET A1.20 FOR FIXTURE SCHEDULE Fx <br />AREA OF DEMO <br />AREA OF PATCH AND/OR REPAIR, REFER TO KEYNOTE <br />NEW SHEAR WALL SHEATHING, REFER TO STRUCTURAL DRAWINGS <br />2x WOOD STUDS @ 16" O.C., MATCH ADJACENT WALL ASSEMBLY <br />EXISTING WOOD STUD WALL TO REMAIN <br />-NEW GYP BD SHEATHING ON INTERIOR SIDE(S) OF ALL (E) WALLS, TYP. <br />-ALL EXTERIOR WALLS TO RECEIVE R-19 BATT INSULATION <br />FINISH FLOOR <br />0" <br />ROOF <br />15' -0" <br />1 <br />A3.01 <br />2524232221 <br />2018 <br />2 <br />A3.01 <br />ABCDEF <br />F10 <br />F10 F10 F10 F10 <br />TYP. <br />23-02 <br />TYP. <br />05-08 <br />08-03 <br />TYP. <br />09-03TYP. <br />32-06 <br />TYP. <br />07-04 <br />TYP. <br />09-03 <br />09-06 09-06 <br />19.1 <br />F9 F9 <br />TYP. <br />02-47 <br />2 <br />A5.05 <br />3 <br />A5.02 <br />13 <br />A5.05 <br />3' - 0 1/2" <br />EQ EQEQEQ <br />11 <br />' <br /> <br />- <br /> <br />6 <br />" <br /> <br />T <br />Y <br />P <br />. <br />8' <br /> <br />- <br /> <br />1 <br />" <br />10 <br />' <br /> <br />- <br /> <br />3 <br />" <br />32-07 <br />32-07 <br />ABCDEF <br />TYP. <br />02-14 <br />02-07 <br />02-07 <br />.02-01 02-09 02-10 02-10 <br />TYP. <br />02-17 <br />08 09 <br />17 19 <br />21 22 23 24 <br />25 <br />Scale <br />Project number <br />Date <br />Drawn by <br />Jen Dunbar, AIA <br />phone: 310.435.3928 <br />12314 La Maida Street <br />Valley Village, CA 91607 <br />jen@dunbararchitecture.com <br />DUNBAR <br />ARCHITECTURE <br />JD/AP <br />1/4" = 1'-0" <br />4/ <br />7 <br />/ <br />2 <br />0 <br />2 <br />5 <br /> <br />9 <br />: <br />2 <br />1 <br />: <br />4 <br />2 <br /> <br />P <br />M <br />A2.01 <br />EXTERIOR <br />ELEVATIONS <br />23004 <br />CYPRESS CENTER <br />RESTORATION <br />CITY OF SANTA ANA <br />1/17/2025 <br />625 S. CYPRESS AVE. <br />SANTA ANA, CA 92701 <br />1/4" = 1'-0"A2.01 <br />2 NORTH ELEVATION - PROPOSED <br />02-01 DEMO (E) NON-ORIGINAL CARPORT STRUCTURE AND SLAB <br />02-07 (E) WINDOW TO BE RESTORED, PROTECT AS REQUIRED; REFER TO A6.00 WINDOW SCHEDULE AND <br />A6.01 WINDOW INVENTORY FOR ADDITIONAL DIRECTION <br />02-09 (E) WINDOW TO BE REMOVE AND SALVAGED FOR REINSTALLATION AT REAR ELEVATION, REFER <br />TO THE ELEVATIONS AND WINDOW SCHEDULE FOR LOCATION; REFER TO A6.00 WINDOW <br />SCHEDULE AND A6.01 WINDOW INVENTORY FOR ADDITIONAL DIRECTION <br />02-10 (E) DOOR OPENING TO REMAIN, REFER TO A1.00 FOR NEW DOOR OR WINDOW REPLACEMENT <br />02-14 ORIGINAL CLAY TILE ROOF TO BE SALVAGED, CLEANED AND RESTORED; PROTECT (E) SHEATHING <br />IN PLACE; REFER TO A1.10 FOR ADDITIONAL SCOPE <br />02-17 DEMO (E) PARAPET CAP <br />02-47 (E) PLASTER DETAIL TO REMAIN, PATCH AND REPAIR AS REQUIRED <br />05-08 PARAPET CAP <br />07-04 ORIGINAL CLAY TILE ROOF TO BE SALVAGED, CLEANED AND RESTORED, OVER PLYWOOD <br />SHEATHING PER STRUCTURAL DWGS, OVER (E) 1X6 SHEATHING; NEW REPLACEMENT TILE TO BE <br />SOURCED FROM GLADDING MCBEAN AT BROKEN TILES TO MATCH ORIGINAL SHAPE AND COLOR <br />BLEND AND INSTALL NEW BIRD STOPS AT END TILES <br />08-03 INFILL PREVIOUS WINDOW; SALVAGE WINDOW AND CASING FOR REUSE AND RELOCATE TO REAR <br />ELEVATION <br />09-03 (E) PLASTER WALL FINISH TO REMAIN, PROTECT IN PLACE; PATCH AND REPAIR AREAS AS <br />REQUIRED, FOR COST ESTIMATE ASSUME 10% OF THE AREA NEEDS PATCHING; ALL AREAS TO BE <br />PAINTED <br />09-06 INFILL WALL AT (E) DOOR OPENING, MATCH ADJACENT PROFILE AND TEXTURE, INCLUDING <br />PLASTER BASE <br />23-02 CONDITION OF ALL VENTS IS CURRENTLY UNKNOWN, TYP. SALVAGE, REPAIR, AND REINSTALL <br />WHERE POSSIBLE; NEW WORK TO MATCH ORIGINAL <br />32-06 8'-0" TALL METAL FENCE AT SIDES AND REAR PERIMETER OF SITE <br />32-07 8'-0" TALL PEDESTRIAN GATE, REFER TO SITE PLAN AND GATE SCHEDULE <br />1/4" = 1'-0"A2.01 <br />1 NORTH ELEVATION - EXISTING/DEMO <br />1 <br />No. Description Date <br />DESIGN DEVELOPMENT 1/12/2024 <br />75% CD 3/15/2024 <br />90% CD 5/14/2024 <br />PERMIT SET 5/17/2024 <br />1 PRESCREEN UPDATES 6/17/2024 <br />OCFA SUBMITTAL 9/26/2024 <br />BACKCHECK SET 1/17/2024 <br />BACKCHECK SET_V2 4/8/2025