Laserfiche WebLink
X <br />X <br />X <br />X X X X X X X X X X X X X X <br />X X X X X X X X X X X X X X X X X X X X X X X X <br />G1 <br />G2 <br />G5 <br />G3 <br />G4 <br />EXISTING POWER POLE <br />UNDERGROUND CONDUITS, ENCASE IN <br />CONCRETE, PER APPROVED UTILITY DRAWINGS <br />MSA <br />CONDUIT DOWN UTILITY POLE AND TRANSITION <br />TO UNDERGROUND CONDUIT PER APPROVED <br />UTILITY DRAWINGS <br />WP <br />#10 <br />PA-16 <br />1 <br />F <br />SF3 <br />SF1 <br />SF2 <br />SF2 <br />SF1 <br />SF2 <br />SF1 <br />SF3 <br />PA-32a <br />32a <br />32a <br />32b <br />32b <br />32b <br />32c <br />32c 32c <br />3 <br />E4.01 <br />(TYP AS <br />NEEDED) <br />PA-32b & PA-32c <br />3/4"C, 4#10 & 1#10GND <br />#10 <br />2 <br />2 <br />#10 <br />#10 <br />E1.00 <br /> 1/8" = 1'-0"E1.00 <br />1 ELECTRICAL SITE PLAN - PROPOSED <br />0'8'4'4' <br />Scale <br />Jen Dunbar, AIA <br />phone: 310.435.3928 <br />12314 La Maida Street <br />Valley Village, CA 91607 <br />jen@dunbararchitecture.com <br />DUNBAR <br />ARCHITECTURE <br />No.Description Date <br />AS NOTED <br />Engineering Corp <br />Mechanical Electrical Plumbing <br />1920 MAIN STREET, SUITE 820 <br />IRVINE, CA 92614 <br />TEL: 949.516.6480 <br />EFORPDERETS <br />I <br />GER RE <br />EN <br />IGNE <br />LANOISS <br />C A L I FORNIASTATEOF <br />LEC T R ICAL <br />EXP: 3-31-27 <br />EFORPDERETS <br />I <br />GER RE <br />EN <br />IGNE <br />LANOISS <br />C A L I FORNIASTATEOF <br />No. E21819 <br />E <br /> ALI S A FAIAN <br />90% CD 5/02/2024 <br />CYPRESS STREET <br />FIRE STATION <br />REHABILITATION <br />CITY OF SANTA ANA <br />625 S. CYPRESS <br />SANTA ANA, CA <br />Project number <br />Date <br />Drawn by TP/HH <br />23004 <br />1/15/2025 <br />PERMIT SET 5/17/2024 <br />BACK CHECK SET 1/15/2025 <br />BACK CHECK SET_V2 4/08/2025 <br />ELECTRICAL <br />SITE PLAN <br />GENERAL NOTES: <br />1.SOUTHERN CALIFORNIA EDISON (SCE) APPROVAL IS REQUIRED FOR METER LOCATION PRIOR TO INSTALLATION. <br />2.FIELD INSPECTORS TO REVIEW AND APPROVE UNDERGROUND SERVICE REQUIREMENTS PRIOR TO CONCRETE <br />PLACEMENT. <br />3.SERVICE EQUIPMENT AND SUBPANELS TO HAVE A MININUM 30 INCH WIDE BY 36 INCH DEEP CLEAR WORK SPACE. (CEC <br />1010.26). <br />4.CONTRACTOR TO CALL UNDERGROUND SERVICE ALERT/DIG ALERT HOTLINES PRIOR TO CONSTRUCTION. <br />5.ALL ELECTRICAL EQUIPMENT MOUNTED OUTDOORS SHALL BE WEATHERPROOF (NEMA 3R). <br />6.ALL OPEN TRENCHES SHALL BE COVERED IN HEAVY PLYWOOD AT ALL TIMES WHEN NO WORK IS BEING PERFORMED. IN <br />TRAFFIC AREAS CONTRACTOR SHALL USE ONLY HALF OF THE STREET AND THE TRENCHES SHALL BE COVERED BY 1" <br />THICK STEEL PLATES AT ALL TIMES. CONTRACTOR SHALL PROVIDE FLAG MEN TO DIRECT TRAFFIC. <br />7.ALL OUTDOOR EQUIPMENT SHALL BE WEATHERPROOF (NEMA 3R) ENCLOSURE. <br />8.ALL OUTDOOR RECEPTACLES SHALL BE PROVIDED AS GFCI AND WITH WHILE-IN-USE COVERS. <br />9.THE ELECTRICAL DRAWINGS ARE DIAGRAMMATIC ONLY. DO NOT SCALE THE ELECTRICAL DRAWINGS TO <br />DETERMINE THE LOCATION OF THE EQUIPMENT OR OUTLETS. SEE ARCHITECTURAL PLANS, WHERE PROVIDED ON <br />PROJECT FOR EXTENT OF DEMOLITION. <br />10.ALL PENETRATIONS THROUGH FIRE RATED WALLS SHALL BE PROTECTED FROM SPREAD OF FIRE WITH AN APPROVED <br />FIRESTOP SYSTEM EQUAL OR GREAT THAN THE FIRE RATING OF THE WALL. <br />11.ALL DEVICE HEIGHTS SHALL BE VERIFIED WITH THE ARCHITECT PRIOR TO ROUGH-IN. <br />12.PROVIDE ADDITIONAL J-BOX NEAR PANEL FOR MULTIPLE HOMERUN CIRCUITRY <br />13.PROVIDE DEDICATED NEUTRAL FOR EACH NEW CIRCUIT, EXCEPT WHERE OTHERWISE NOTED. HOME RUN CONDUCTORS <br />MAY BE COMBINED INTO ONE CONDUIT. NO RACEWAY OR CABLE SHALL CONTAIN MORE THAN NINE (9) CURRENT <br />CARRYING CONDUCTORS. WHERE MULTIPLE CONDUCTORS IN EXCESS OF THREE (3) ARE INDICATED ON THESE <br />DRAWINGS, THEY HAVE BEEN DERATED AS REQUIRED BY CEC ARTICLE 310 REQUIREMENTS. <br />KEYNOTES: <br />PROVIDE NEMA 3R, WEATHERPROOF, 250V, 30AS/20AF, 1ΙΈ, 3-W & GND DISCONNECT SWITCH FOR MOTORIZED GATE. <br />COORDINATE EXACT LOCATION AND REQUIREMENTS IN THE FIELD. <br />EXTERIOR LIGHTING SHALL BE ROUTED THROUGH AND CONTROLLED BY ASTRONOMIC TIMECLOCK. RELAYS ARE <br />LOCATED IN CEILING SPACE AT OFFICE/KITCHEN SPACE 10 WHERE OVERRIDE SWITCHES ARE LOCATED. COORDINATE <br />EXACT LOCATION OF TIMECLOCK AND SETTING OF TIMES IN THE FIELD. <br />1 <br />2