Laserfiche WebLink
SECTION 09 6513 RUBBER BASE <br />PART 1 - GENERAL <br />1.01 SUMMARY <br />A. SECTION INCLUDES: <br />1. TOPSET COVED RUBBER BASE FOR INSTALLATION WITH SURFACE FLOORING. <br />B. RELATED REQUIREMENTS: <br />1. DIVISION 01 - GENERAL REQUIREMENTS. <br />2. SECTION 09 6516 - RESILIENT SHEET FLOORING.. <br />3. SECTION 09 680 - CARPET TILE <br />1.02 SUBMITTALS <br />A. PRODUCT DATA: SUBMIT MANUFACTURER’S PUBLISHED TECHNICAL DATA DESCRIBING <br />MATERIALS, CONSTRUCTION AND RECOMMENDED INSTALLATION INSTRUCTIONS. SUBMIT <br />TECHNICAL DATA AND INSTALLATION INSTRUCTIONS FOR EACH ADHESIVE MATERIAL. <br />B. MAINTENANCE INSTRUCTIONS: SUBMIT MANUFACTURER’S RECOMMENDATIONS FOR <br />MAINTENANCE, CARE AND CLEANING OF BASE. <br />C. SAMPLES: SUBMIT SAMPLES OF TOP SET BASE IN EACH AVAILABLE COLOR. FOLLOWING <br />COLOR SELECTIONS, SUBMIT SAMPLES, NOT LESS THAN 12 INCHES LONG OF EACH <br />SELECTED COLOR AND TYPE. SUBMIT PINT CANS OF EACH TYPE ADHESIVE. <br />D. MAINTENANCE MATERIALS: BEFORE SUBSTANTIAL COMPLETION, DELIVER AT LEAST 50 <br />LINEAL FEET AND FIVE OUTSIDE CORNER UNITS OF EACH COLOR OF RUBBER BASE <br />INSTALLED. DELIVER THE MATERIALS IN UNOPENED FACTORY CONTAINERS OR IN SEALED <br />CARTONS WITH LABELS IDENTIFYING THE CONTENTS, MATCHING INSTALLED MATERIALS. <br />INCLUDE UNOPENED CANS OF ADHESIVES ADEQUATE TO INSTALL THE MAINTENANCE <br />MATERIALS. <br />1.03 QUALITY ASSURANCE <br />A. QUALIFICATIONS OF INSTALLER: MINIMUM FIVE YEARS EXPERIENCE IN SUCCESSFULLY <br />INSTALLING THE SAME OR SIMILAR FLOORING MATERIALS. <br />B. COMPLY WITH THE FOLLOWING AS A MINIMUM REQUIREMENT: <br />1. ASTM E84: STANDARD TEST METHOD FOR SURFACE BURNING CHARACTERISTICS <br />OF BUILDING MATERIALS. <br />2. ASTM F1861: STANDARD SPECIFICATION FOR RESILIENT WALL BASE. <br />3. COMPLY WITH CURRENT CHPS REQUIREMENTS, WWW.CHPS.NET. <br />4. CHEMICALLY BASED PRODUCTS SUCH AS SEALERS, PRIMERS, FILLERS, <br />ADHESIVES, ETC. MUST BE APPROVED BY OWNER’S OFFICE OF ENVIRONMENTAL <br />HEALTH AND SAFETY (OEHS). <br />5. EACH SELECTED COLOR AND CONFIGURATION SHALL BE FROM SAME DYE LOT <br />AND COLOR. <br />1.04 DELIVERY, STORAGE AND HANDLING <br />A. MATERIALS SHALL BE DELIVERED TO THE PROJECT SITE IN ORIGINAL UNOPENED <br />MANUFACTURER’S PACKAGING CLEARLY LABELED WITH MANUFACTURER’S NAME. STORE <br />MATERIALS AT ROOM TEMPERATURE, BUT NOT LESS THAN 70 DEGREES F, FOR A MINIMUM <br />OF 48 HOURS BEFORE INSTALLATION, UNLESS OTHERWISE INDICATED IN MANUFACTURER’S <br />PRINTED INSTRUCTIONS. <br />1.05 PROJECT CONDITIONS <br />A. VENTILATION AND TEMPERATURE: VERIFY AREAS THAT ARE TO RECEIVE RUBBER BASE ARE <br />VENTILATED TO REMOVE FUMES FROM INSTALLATION MATERIALS, AND AREAS ARE WITHIN <br />TEMPERATURE RANGE RECOMMENDED BY THE VARIOUS MATERIAL MANUFACTURES FOR <br />SITE INSTALLATION CONDITIONS. <br />1.06 WARRANTY <br />A. MANUFACTURER SHALL PROVIDE A FIVE YEAR MATERIAL WARRANTY. <br />B. INSTALLER SHALL PROVIDE A TWO YEAR FABRICATION AND INSTALLATION WARRANTY. <br />PART 2 - PRODUCTS <br />2.01 ACCEPTABLE MANUFACTURERS <br />A. SEE FINISH LIST FOR SPECIFIED PRODUCT <br />2.02 MATERIALS <br />A. RUBBER BASE: CONFORM TO ASTM F 861; GROUP 2, SOLID (HOMOGENEOUS); TYPE 1, TS, <br />(THERMOSET) VULCANIZED RUBBER, STYLE A, 4-INCH HIGH UNLESS OTHERWISE INDICATED, <br />INTEGRAL COLORS AS SELECTED, NON-SHRINKING, 1/8 INCH THICK, WITH MATCHING <br />MOLDED OUTSIDE CORNERS. <br />B. BASE ADHESIVE: WATER BASED, LOW ODOR TYPE, AS RECOMMENDED BY MANUFACTURER <br />OF RUBBER BASE. <br />PART 3 - EXECUTION <br />3.01 COORDINATION <br />A. COORDINATE THE WORK OF THIS SECTION WITH OTHER SECTIONS TO PROVIDE A LEVEL, <br />SMOOTH AND CLEAN FINISH SURFACES TO RECEIVE RUBBER BASE. <br />3.02 EXAMINATION <br />A. FIELD VERIFY DIMENSIONS AND OTHER CONDITIONS AFFECTING THE WORK OF THIS <br />SECTION BEFORE COMMENCING THE WORK OF THIS SECTION. <br />B. BEFORE WORK IS STARTED, EXAMINE SURFACES THAT ARE TO RECEIVE RUBBER BASE. <br />DEFICIENCIES SHALL BE CORRECTED BEFORE STARTING THE WORK OF THIS SECTION. <br />3.03 PREPARATION <br />A. DO NOT START PREPARATION UNTIL ADJACENT CONCRETE FLOOR SLABS ARE AT LEAST 90 <br />DAYS OLD AND FINISH FLOORING IS INSTALLED. <br />B. INSTALL RUBBER BASE WHEN AMBIENT TEMPERATURE IS 70 DEGREES F. OR HIGHER. <br />3.04 INSTALLATION <br />A. INSTALL TOP SET BASE AT HARD FLOORS, INCLUDING RESILIENT FLOORING, CONCRETE <br />AND WOOD, CARPET AND OTHER SOFT FLOORS. <br />B. SECURELY FASTEN CEMENT BASE TO BACKING IN LONG LENGTHS IN ACCORDANCE WITH <br />MANUFACTURER’S RECOMMENDATIONS. LAY OUT LENGTHS SO THAT NOT LESS THAN 18 <br />INCHES LONG FILLER PIECES ARE PROVIDED. ASSURE THAT TOP AND TOE CONTINUOUSLY <br />CONTACT THE WALL AND FLOOR, AND THAT ALL JOINTS ARE TIGHT. INSTALL MATCHING <br />FACTORY FORMED EXTERNAL CORNERS AT ALL OFFSETS. INSIDE CORNERS SHALL BE <br />COPED; WRAPPED CORNERS ARE NOT ACCEPTABLE. <br />C. USE OF ADHESIVE GUN IS PROHIBITED. APPLY ADHESIVE DIRECTLY TO SUBSTRATE USING <br />THE APPROPRIATE NOTCHED TROWEL OR SPREADER ACCORDING TO MANUFACTURER’S <br />INSTRUCTIONS. MAINTAIN 1/8 INCH GAP FROM TOP OF BASE TO PREVENT ADHESIVE <br />OOZING ONTO ADJACENT SURFACES. <br />D. BASE AND OUTSIDE CORNERS SHALL BE ROLLED WITH A SEAM ROLLER BEFORE ADHESIVE <br />SETS. <br />3.05 CLEANING <br />A. MAINTAIN SURFACES OF BASE CLEAN AS INSTALLATION PROGRESSES. CLEAN RUBBER <br />BASE WHEN SUFFICIENTLY SEATED AND REMOVE FOREIGN SUBSTANCES. <br />B. CLEAN ADJACENT SURFACES OF ADHESIVE OR OTHER DEFACEMENT. REPLACE DAMAGED <br />AND/OR DEFECTIVE WORK TO THE SPECIFIED CONDITION. <br />3.06 CLEAN UP <br />A. REMOVE RUBBISH, DEBRIS AND WASTE MATERIALS AND LEGALLY DISPOSE OF OFF THE <br />PROJECT SITE. <br />3.07 PROTECTION <br />A. PROTECT THE WORK OF THIS SECTION UNTIL SUBSTANTIAL COMPLETION. <br />END OF SECTION <br />B. WIRE HANGERS, BRACES, AND TIES: PROVIDE WIRES AS FOLLOWS: <br />1. STAINLESS-STEEL WIRE: ASTM A 580/A 580M, TYPE 304, NONMAGNETIC, AT <br />KITCHENS AND LAUNDRY. <br />2. SIZE: WIRE DIAMETER SUFFICIENT FOR ITS STRESS AT THREE TIMES <br />HANGER DESIGN LOAD (ASTM C 635/C 635M, TABLE 1, "DIRECT HUNG") WILL <br />BE LESS THAN YIELD STRESS OF WIRE, BUT NOT LESS THAN 0.135-INCH- <br />DIAMETER WIRE. <br />C. HANGER RODS: MILD STEEL, ZINC COATED OR PROTECTED WITH RUST-INHIBITIVE PAINT. <br />D. ANGLE HANGERS: ANGLES WITH LEGS NOT LESS THAN 7/8 INCH WIDE; FORMED WITH <br />0.04-INCH- THICK, GALVANIZED-STEEL SHEET COMPLYING WITH ASTM A 653/A 653M, <br />G90 COATING DESIGNATION; WITH BOLTED CONNECTIONS AND 5/16-INCH- DIAMETER BOLTS. <br />E. HOLD-DOWN CLIPS: MANUFACTURER'S STANDARD HOLD-DOWN. <br />F. IMPACT CLIPS: MANUFACTURER'S STANDARD IMPACT-CLIP SYSTEM DESIGNED TO ABSORB <br />IMPACT FORCES AGAINST ACOUSTICAL PANELS. <br />2.6 METAL EDGE MOLDINGS AND TRIM <br />A. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS <br />BY ONE OF THE FOLLOWING: <br />1. ARMSTRONG WORLD INDUSTRIES, INC. <br />2. CERTAINTEED CORPORATION. <br />3. CHICAGO METALLIC CORPORATION. <br />B. ROLL-FORMED, SHEET-METAL EDGE MOLDINGS AND TRIM: TYPE AND PROFILE INDICATED <br />OR, IF NOT INDICATED, MANUFACTURER'S STANDARD MOLDINGS FOR EDGES AND <br />PENETRATIONS THAT COMPLY WITH SEISMIC DESIGN REQUIREMENTS; FORMED FROM <br />SHEET METAL OF SAME MATERIAL, FINISH, AND COLOR AS THAT USED FOR EXPOSED <br />FLANGES OF SUSPENSION-SYSTEM RUNNERS. <br />1. EDGE MOLDINGS SHALL FIT ACOUSTICAL PANEL EDGE DETAILS AND SUSPENSION <br />SYSTEMS INDICATED AND MATCH WIDTH AND CONFIGURATION OF EXPOSED <br />RUNNERS UNLESS OTHERWISE INDICATED. <br />2. FOR LAY-IN PANELS WITH REVEAL EDGE DETAILS, PROVIDE STEPPED EDGE <br />MOLDING THAT FORMS REVEAL OF SAME DEPTH AND WIDTH AS THAT FORMED <br />BETWEEN EDGE OF PANEL AND FLANGE AT EXPOSED SUSPENSION MEMBER. <br />3. FOR CIRCULAR PENETRATIONS OF CEILING, PROVIDE EDGE MOLDINGS <br />FABRICATED TO DIAMETER REQUIRED TO FIT PENETRATION EXACTLY. <br />C. EXTRUDED-ALUMINUM EDGE MOLDINGS AND TRIM: WHERE INDICATED, PROVIDE <br />MANUFACTURER'S EXTRUDED-ALUMINUM EDGE MOLDINGS AND TRIM OF PROFILE <br />INDICATED OR REFERENCED BY MANUFACTURER'S DESIGNATIONS, INCLUDING SPLICE <br />PLATES, CORNER PIECES, AND ATTACHMENT AND OTHER CLIPS, COMPLYING WITH <br />SEISMIC DESIGN REQUIREMENTS. <br />1. BAKED-ENAMEL OR POWDER-COAT FINISH: MINIMUM DRY FILM THICKNESS OF <br />1.5 MILS. COMPLY WITH ASTM C 635/C 635M AND COATING MANUFACTURER'S <br />WRITTEN INSTRUCTIONS FOR CLEANING, CONVERSION COATING, AND <br />APPLYING AND BAKING FINISH. <br />2.7 ACOUSTICAL SEALANT <br />A. ACOUSTICAL SEALANT: AS SPECIFIED IN SECTION 079219 "ACOUSTICAL JOINT SEALANTS." <br />PART 3 - EXECUTION <br />3.1 EXAMINATION <br />A. EXAMINE SUBSTRATES, AREAS, AND CONDITIONS, INCLUDING STRUCTURAL FRAMING TO <br />WHICH ACOUSTICAL PANEL CEILINGS ATTACH OR ABUT, WITH INSTALLER PRESENT, FOR <br />COMPLIANCE WITH REQUIREMENTS SPECIFIED IN THIS AND OTHER SECTIONS THAT <br />AFFECT CEILING INSTALLATION AND ANCHORAGE AND WITH REQUIREMENTS FOR <br />INSTALLATION TOLERANCES AND OTHER CONDITIONS AFFECTING PERFORMANCE OF <br />ACOUSTICAL PANEL CEILINGS. <br />B. EXAMINE ACOUSTICAL PANELS BEFORE INSTALLATION. REJECT ACOUSTICAL PANELS <br />THAT ARE WET, MOISTURE DAMAGED, OR MOLD DAMAGED. <br />C. PROCEED WITH INSTALLATION ONLY AFTER UNSATISFACTORY CONDITIONS HAVE BEEN <br />CORRECTED. <br />3.2 PREPARATION <br />A. MEASURE EACH CEILING AREA AND ESTABLISH LAYOUT OF ACOUSTICAL PANELS TO <br />BALANCE BORDER WIDTHS AT OPPOSITE EDGES OF EACH CEILING. AVOID USING <br />LESS-THAN-HALF-WIDTH PANELS AT BORDERS UNLESS OTHERWISE INDICATED, AND <br />COMPLY WITH LAYOUT SHOWN ON REFLECTED CEILING PLANS. <br />B. LAYOUT OPENINGS FOR PENETRATIONS CENTERED ON THE PENETRATING ITEMS. <br />3.3 INSTALLATION <br />A. INSTALL ACOUSTICAL PANEL CEILINGS ACCORDING TO ASTM C 636/C 636M, AND <br />MANUFACTURER'S WRITTEN INSTRUCTIONS. <br />1. FIRE-RATED ASSEMBLY: INSTALL FIRE-RATED CEILING SYSTEMS ACCORDING <br />TO TESTED FIRE-RATED DESIGN. <br />B. SUSPEND CEILING HANGERS FROM BUILDING'S STRUCTURAL MEMBERS AND AS FOLLOWS: <br />1. INSTALL HANGERS PLUMB AND FREE FROM CONTACT WITH INSULATION OR <br />OTHER OBJECTS WITHIN CEILING PLENUM THAT ARE NOT PART OF SUPPORTING <br />STRUCTURE OR OF CEILING SUSPENSION SYSTEM. <br />2. SPLAY HANGERS ONLY WHERE REQUIRED AND, IF PERMITTED WITH <br />FIRE-RESISTANCE-RATED CEILINGS,TO MISS OBSTRUCTIONS; OFFSET <br />RESULTING HORIZONTAL FORCES BY BRACING, COUNTERSPLAYING, OR <br />OTHER EQUALLY EFFECTIVE MEANS. <br />3. WHERE WIDTH OF DUCTS AND OTHER CONSTRUCTION WITHIN CEILING PLENUM <br />PRODUCES HANGER SPACINGS THAT INTERFERE WITH LOCATION OF HANGERS AT <br />SPACINGS REQUIRED TO SUPPORT STANDARD SUSPENSION-SYSTEM MEMBERS, <br />INSTALL SUPPLEMENTAL SUSPENSION MEMBERS AND HANGERS IN FORM OF <br />TRAPEZES OR EQUIVALENT DEVICES. <br />4. SECURE WIRE HANGERS TO CEILING-SUSPENSION MEMBERS AND TO SUPPORTS <br />ABOVE WITH A MINIMUM OF THREE TIGHT TURNS. CONNECT HANGERS DIRECTLY <br />TO STRUCTURE OR TO INSERTS, EYE SCREWS, OR OTHER DEVICES THAT ARE <br />SECURE AND APPROPRIATE FOR SUBSTRATE AND THAT WILL NOT DETERIORATE <br />OR OTHERWISE FAIL DUE TO AGE, CORROSION, OR ELEVATED TEMPERATURES. <br />5. SECURE FLAT, ANGLE, CHANNEL, AND ROD HANGERS TO STRUCTURE, INCLUDING <br />INTERMEDIATE FRAMING MEMBERS, BY ATTACHING TO INSERTS, EYE SCREWS, OR <br />OTHER DEVICES THAT ARE SECURE AND APPROPRIATE FOR BOTH THE <br />STRUCTURE TO WHICH HANGERS ARE ATTACHED AND THE TYPE OF HANGER <br />INVOLVED. INSTALL HANGERS IN A MANNER THAT WILL NOT CAUSE THEM TO <br />DETERIORATE OR FAIL DUE TO AGE, CORROSION, OR ELEVATED TEMPERATURES. <br />6. DO NOT SUPPORT CEILINGS DIRECTLY FROM PERMANENT METAL FORMS OR <br />FLOORDECK. FASTEN HANGERS TO CAST-IN-PLACE HANGER INSERTS, POST- <br />INSTALLED MECHANICAL OR ADHESIVE ANCHORS, OR POWER-ACTUATED <br />FASTENERS THAT EXTEND THROUGH FORMS INTO CONCRETE. <br />7. WHEN STEEL FRAMING DOES NOT PERMIT INSTALLATION OF HANGER WIRES <br />AT SPACING REQUIRED, INSTALL CARRYING CHANNELS OR OTHER SUPPLEMENTAL <br />SUPPORT FOR ATTACHMENT OF HANGER WIRES. <br />8. DO NOT ATTACH HANGERS TO STEEL DECK TABS. <br />9. DO NOT ATTACH HANGERS TO STEEL ROOF DECK. ATTACH HANGERS TO <br />STRUCTURAL MEMBERS. <br />10. SPACE HANGERS NOT MORE THAN 48 INCHES O.C. ALONG EACH MEMBER <br />SUPPORTED DIRECTLY FROM HANGERS UNLESS OTHERWISE INDICATED; <br />PROVIDE HANGERS NOT MORE THAN 8 INCHES FROM ENDS OF EACH MEMBER. <br />11. SIZE SUPPLEMENTAL SUSPENSION MEMBERS AND HANGERS TO SUPPORT <br />CEILING LOADS WITHIN PERFORMANCE LIMITS ESTABLISHED BY REFERENCED <br />STANDARDS. <br />C. SECURE BRACING WIRES TO CEILING SUSPENSION MEMBERS AND TO SUPPORTS WITH A <br />MINIMUM OF FOUR TIGHT TURNS. SUSPEND BRACING FROM BUILDING'S STRUCTURAL <br />MEMBERS AS REQUIRED FOR HANGERS, WITHOUT ATTACHING TO PERMANENT METAL <br />FORMS, STEEL DECK, OR STEEL DECK TABS. FASTEN BRACING WIRES INTO CONCRETE <br />WITH CAST-IN-PLACE OR POSTINSTALLED ANCHORS. <br />D. INSTALL EDGE MOLDINGS AND TRIM OF TYPE INDICATED AT PERIMETER OF ACOUSTICAL <br />CEILING AREA AND WHERE NECESSARY TO CONCEAL EDGES OF ACOUSTICAL PANELS. <br />1. APPLY ACOUSTICAL SEALANT IN A CONTINUOUS RIBBON CONCEALED ON <br />BACK OF VERTICAL LEGS OF MOLDINGS BEFORE THEY ARE INSTALLED. <br />2. SCREW ATTACH MOLDINGS TO SUBSTRATE AT INTERVALS NOT MORE THAN <br />16 INCHES O.C. AND NOT MORE THAN 3 INCHES FROM ENDS. MITER CORNERS <br />ACCURATELY AND CONNECT SECURELY. <br />3. DO NOT USE EXPOSED FASTENERS, INCLUDING POP RIVETS, ON MOLDINGS <br />AND TRIM. <br />E. INSTALL SUSPENSION-SYSTEM RUNNERS SO THEY ARE SQUARE AND SECURELY <br />INTERLOCKED WITH ONE ANOTHER. REMOVE AND REPLACE DENTED, BENT, OR <br />KINKED MEMBERS. <br />F. INSTALL ACOUSTICAL PANELS WITH UNDAMAGED EDGES AND FIT ACCURATELY INTO <br />SUSPENSION-SYSTEM RUNNERS AND EDGE MOLDINGS. SCRIBE AND CUT PANELS AT <br />BORDERS AND PENETRATIONS TO PROVIDE PRECISE FIT. <br />1. ARRANGE DIRECTIONALLY PATTERNED ACOUSTICAL PANELS AS FOLLOWS: <br />A. INSTALL PANELS WITH PATTERN RUNNING IN ONE DIRECTION PARALLEL <br />TO SHORT AXIS OF SPACE. <br />2. FOR SQUARE-EDGED PANELS, INSTALL PANELS WITH EDGES FULLY HIDDEN <br />FROM VIEW BY FLANGES OF SUSPENSION-SYSTEM RUNNERS AND MOLDINGS. <br />3. FOR REVEAL-EDGED PANELS ON SUSPENSION-SYSTEM RUNNERS, INSTALL <br />PANELS WITH BOTTOM OF REVEAL IN FIRM CONTACT WITH TOP SURFACE OF <br />RUNNER FLANGES. <br />4. FOR REVEAL-EDGED PANELS ON SUSPENSION-SYSTEM MEMBERS WITH <br />BOX-SHAPED FLANGES, INSTALL PANELS WITH REVEAL SURFACES IN FIRM <br />CONTACT WITH SUSPENSION-SYSTEM SURFACES AND PANEL FACES FLUSH <br />WITH BOTTOM FACE OF RUNNERS. <br />5. PAINT CUT EDGES OF PANEL REMAINING EXPOSED AFTER INSTALLATION; <br />MATCH COLOR OF EXPOSED PANEL SURFACES USING COATING RECOMMENDED <br />IN WRITING FOR THIS PURPOSE BY ACOUSTICAL PANEL MANUFACTURER. <br />6. INSTALL HOLD-DOWN AND IMPACT CLIPS IN AREAS INDICATED; SPACE ACCORDING <br />TO PANEL MANUFACTURER'S WRITTEN INSTRUCTIONS UNLESS OTHERWISE <br />INDICATED. <br />A. HOLD-DOWN CLIPS: SPACE 24 INCHES O.C. ON ALL CROSS RUNNERS. <br />7. PROTECT LIGHTING FIXTURES AND AIR DUCTS ACCORDING TO REQUIREMENTS <br />INDICATED FOR FIRE-RESISTANCE-RATED ASSEMBLY. <br />3.4 ERECTION TOLERANCES <br />A. SUSPENDED CEILINGS: INSTALL MAIN AND CROSS RUNNERS LEVEL TO A TOLERANCE OF <br />1/8 INCH IN 12 FEET, NON-CUMULATIVE. <br />B. MOLDINGS AND TRIM: INSTALL MOLDINGS AND TRIM TO SUBSTRATE AND LEVEL WITH <br />CEILING SUSPENSION SYSTEM TO A TOLERANCE OF 1/8 INCH IN 12 FEET, NON-CUMULATIVE. <br />3.5 FIELD QUALITY CONTROL <br />A. SPECIAL INSPECTIONS: OWNER WILL ENGAGE A QUALIFIED SPECIAL INSPECTOR TO <br />PERFORM THE FOLLOWING SPECIAL INSPECTIONS: <br />1. PERIODIC INSPECTION DURING THE INSTALLATION OF SUSPENDED CEILING <br />GRIDS ACCORDING TO ASCE/SEI 7. <br />B. TESTING AGENCY: OWNER WILL ENGAGE A QUALIFIED TESTING AGENCY TO PERFORM <br />TESTS AND INSPECTIONS. <br />C. PERFORM THE FOLLOWING TESTS AND INSPECTIONS OF COMPLETED INSTALLATIONS <br />OF ACOUSTICAL PANEL CEILING HANGERS AND ANCHORS AND FASTENERS IN SUCCESSIVE <br />STAGES AND WHEN INSTALLATION OF CEILING SUSPENSION SYSTEMS ON EACH FLOOR HAS <br />REACHED 20 PERCENT COMPLETION, BUT NO PANELS HAVE BEEN INSTALLED. DO NOT <br />PROCEED WITH INSTALLATIONS OF ACOUSTICAL PANEL CEILING HANGERS FOR THE NEXT <br />AREA UNTIL TEST RESULTS FOR PREVIOUSLY COMPLETED INSTALLATIONS OF ACOUSTICAL <br />PANEL CEILING HANGERS SHOW COMPLIANCE WITH REQUIREMENTS. <br />1. WITHIN EACH TEST AREA, TESTING AGENCY WILL SELECT ONE OF EVERY 10 <br />POWER-ACTUATED FASTENERS AND POSTINSTALLED ANCHORS USED TO <br />ATTACH HANGERS TO CONCRETE AND WILL TEST THEM FOR 200 LBF OF TENSION; <br />IT WILL ALSO SELECT ONE OF EVERY TWO POSTINSTALLED ANCHORS USED TO <br />ATTACH BRACING WIRES TO CONCRETE AND WILL TEST THEM FOR 440 LBF OF <br />TENSION. <br />2. WHEN TESTING DISCOVERS FASTENERS AND ANCHORS THAT DO NOT COMPLY <br />WITH REQUIREMENTS, TESTING AGENCY WILL TEST THOSE ANCHORS NOT <br />PREVIOUSLY TESTED UNTIL 20 PASS CONSECUTIVELY AND THEN WILL RESUME <br />INITIAL TESTING FREQUENCY. <br />D. PREPARE TEST AND INSPECTION REPORTS. <br />3.6 CLEANING <br />A. CLEAN EXPOSED SURFACES OF ACOUSTICAL PANEL CEILINGS, INCLUDING TRIM, EDGE <br />MOLDINGS, AND SUSPENSION-SYSTEM MEMBERS. COMPLY WITH MANUFACTURER'S <br />WRITTEN INSTRUCTIONS FOR CLEANING AND TOUCHUP OF MINOR FINISH DAMAGE. <br />B. REMOVE AND REPLACE CEILING COMPONENTS THAT CANNOT BE SUCCESSFULLY CLEANED <br />AND REPAIRED TO PERMANENTLY ELIMINATE EVIDENCE OF DAMAGE. <br />END OF SECTION 09 5113 <br />SECTION 09 5113 - ACOUSTICAL PANEL CEILINGS <br />PART 1 - GENERAL <br />1.1 RELATED DOCUMENTS <br />A. DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL AND <br />SUPPLEMENTARY CONDITIONS AND DIVISION 01 SPECIFICATION SECTIONS, APPLY TO <br />THIS SECTION. <br />1.2 SUMMARY <br />A. SECTION INCLUDES ACOUSTICAL PANELS AND EXPOSED SUSPENSION SYSTEMS FOR <br />INTERIOR CEILINGS. <br />B. PRODUCTS FURNISHED, BUT NOT INSTALLED UNDER THIS SECTION, INCLUDE <br />ANCHORS, CLIPS, AND OTHER CEILING ATTACHMENT DEVICES TO BE CAST IN <br />CONCRETE. <br />1.3 ACTION SUBMITTALS <br />A. PRODUCT DATA: FOR EACH TYPE OF PRODUCT. <br />B. SAMPLES: FOR EACH EXPOSED PRODUCT AND FOR EACH COLOR AND TEXTURE <br />SPECIFIED, 6 INCHES IN SIZE. <br />C. SAMPLES FOR INITIAL SELECTION: FOR COMPONENTS WITH FACTORY-APPLIED FINISHES. <br />1.5 INFORMATIONAL SUBMITTALS <br />A. COORDINATION DRAWINGS: REFLECTED CEILING PLANS, DRAWN TO SCALE, ON WHICH <br />THE FOLLOWING ITEMS ARE SHOWN AND COORDINATED WITH EACH OTHER, USING <br />INPUT FROM INSTALLERS OF THE ITEMS INVOLVED: <br />1. CEILING SUSPENSION-SYSTEM MEMBERS. <br />2. STRUCTURAL MEMBERS TO WHICH SUSPENSION SYSTEMS WILL BE ATTACHED. <br />3. METHOD OF ATTACHING HANGERS TO BUILDING STRUCTURE. <br />A. FURNISH LAYOUTS FOR CAST-IN-PLACE ANCHORS, CLIPS, AND OTHER <br />CEILING ATTACHMENT DEVICES WHOSE INSTALLATION IS SPECIFIED <br />IN OTHER SECTIONS. <br />4. CARRYING CHANNELS OR OTHER SUPPLEMENTAL SUPPORT FOR HANGER- <br />WIRE ATTACHMENT WHERE CONDITIONS DO NOT PERMIT INSTALLATION OF <br />HANGER WIRES AT REQUIRED SPACING. <br />5. SIZE AND LOCATION OF INITIAL ACCESS MODULES FOR ACOUSTICAL PANELS. <br />6. ITEMS PENETRATING FINISHED CEILING AND CEILING-MOUNTED ITEMS INCLUDING <br />THE FOLLOWING: <br />A. LIGHTING FIXTURES. <br />B. DIFFUSERS. <br />C. GRILLES. <br />D. SPEAKERS. <br />E. SPRINKLERS. <br />F. ACCESS PANELS. <br />G. PERIMETER MOLDINGS. <br />7. SHOW OPERATION OF HINGED AND SLIDING COMPONENTS COVERED BY OR <br />ADJACENT TO ACOUSTICAL PANELS. <br />8. MINIMUM DRAWING SCALE: 1/8 INCH = 1 FOOT. <br />B. QUALIFICATION DATA: FOR TESTING AGENCY. <br />C. PRODUCT TEST REPORTS: FOR EACH ACOUSTICAL PANEL CEILING, FOR TESTS PERFORMED <br />BY A QUALIFIED TESTING AGENCY. <br />D. EVALUATION REPORTS: FOR EACH ACOUSTICAL PANEL CEILING SUSPENSION SYSTEM AND <br />ANCHOR AND FASTENER TYPE, FROM ICC-ES. <br />E. FIELD QUALITY-CONTROL REPORTS. <br />1.6 CLOSEOUT SUBMITTALS <br />A. MAINTENANCE DATA: FOR FINISHES TO INCLUDE IN MAINTENANCE MANUALS. <br />1.7 MAINTENANCE MATERIAL SUBMITTALS <br />A. FURNISH EXTRA MATERIALS, FROM THE SAME PRODUCT RUN, THAT MATCH PRODUCTS <br />INSTALLED AND THAT ARE PACKAGED WITH PROTECTIVE COVERING FOR STORAGE AND <br />IDENTIFIED WITH LABELS DESCRIBING CONTENTS. <br />1. ACOUSTICAL CEILING UNITS: FULL-SIZE PANELS EQUAL TO 2 PERCENT OF <br />QUANTITY INSTALLED. <br />2. SUSPENSION-SYSTEM COMPONENTS: QUANTITY OF EACH EXPOSED COMPONENT <br />EQUAL TO 2 PERCENT OF QUANTITY INSTALLED. <br />3. CLIPS: EQUAL TO 2 PERCENT OF QUANTITY INSTALLED. <br />1.8 DELIVERY, STORAGE, AND HANDLING <br />A. DELIVER ACOUSTICAL PANELS, SUSPENSION-SYSTEM COMPONENTS, AND ACCESSORIES <br />TO PROJECT SITE AND STORE THEM IN A FULLY ENCLOSED, CONDITIONED SPACE WHERE <br />THEY WILL BE PROTECTED AGAINST DAMAGE FROM MOISTURE, HUMIDITY, <br />TEMPERATURE EXTREMES, DIRECT SUNLIGHT, SURFACE CONTAMINATION, AND OTHER <br />CAUSES. <br />B. BEFORE INSTALLING ACOUSTICAL PANELS, PERMIT THEM TO REACH ROOM <br />TEMPERATURE AND A STABILIZED MOISTURE CONTENT. <br />1.9 FIELD CONDITIONS <br />A. ENVIRONMENTAL LIMITATIONS: DO NOT INSTALL ACOUSTICAL PANEL CEILINGS UNTIL <br />SPACES ARE ENCLOSED AND WEATHERTIGHT, WET-WORK IN SPACES IS COMPLETE <br />AND DRY, WORK ABOVE CEILINGS IS COMPLETE, AND AMBIENT TEMPERATURE AND <br />HUMIDITY CONDITIONS ARE MAINTAINED AT THE LEVELS INDICATED FOR PROJECT WHEN <br />OCCUPIED FOR ITS INTENDED USE. <br />1. PRESSURIZED PLENUMS: OPERATE VENTILATION SYSTEM FOR NOT LESS THAN 48 HOURS BEFORE <br />BEGINNING ACOUSTICAL PANEL CEILING INSTALLATION. <br />PART 2 - PRODUCTS <br />2.1 MANUFACTURERS <br />A. SOURCE LIMITATIONS: OBTAIN EACH TYPE OF ACOUSTICAL CEILING PANEL AND ITS <br />SUPPORTING SUSPENSION SYSTEM FROM SINGLE SOURCE FROM SINGLE MANUFACTURER. <br />2.2 PERFORMANCE REQUIREMENTS <br />A. SURFACE-BURNING CHARACTERISTICS: COMPLY WITH ASTM E 84; TESTING BY A <br />QUALIFIED TESTING AGENCY. IDENTIFY PRODUCTS WITH APPROPRIATE MARKINGS OF <br />APPLICABLE TESTING AGENCY. <br />1. FLAME-SPREAD INDEX: CLASS B ACCORDING TO ASTM E 1264. <br />2. SMOKE-DEVELOPED INDEX: 450 OR LESS. <br />B. FIRE-RESISTANCE RATINGS: COMPLY WITH ASTM E 119; TESTING BY A QUALIFIED <br />TESTING AGENCY. IDENTIFY PRODUCTS WITH APPROPRIATE MARKINGS OF APPLICABLE <br />TESTING AGENCY. <br />1. INDICATE DESIGN DESIGNATIONS FROM UL OR FROM THE LISTINGS OF ANOTHER <br />QUALIFIED TESTING AGENCY. <br />2.3 ACOUSTICAL PANELS <br />A. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY <br />ONE OF THE FOLLOWING: <br />1. SEE FINISH LIST FOR SPECIFIED PRODUCT <br />B. ACOUSTICAL PANEL STANDARD: PROVIDE MANUFACTURER'S STANDARD PANELS <br />ACCORDING TO ASTM E 1264 AND DESIGNATED BY TYPE, FORM, PATTERN, <br />ACOUSTICAL RATING, AND LIGHT REFLECTANCE UNLESS OTHERWISE INDICATED. <br />C. CLASSIFICATION: PROVIDE[ FIRE-RESISTANCE-RATED] PANELS AS FOLLOWS: <br />1. PER FINISH LIST <br />D. COLOR: WHITE. <br />E. LIGHT REFLECTANCE (LR): NOT LESS THAN 0.75. <br />F. CEILING ATTENUATION CLASS (CAC): NOT LESS THAN 30. <br />G. NOISE REDUCTION COEFFICIENT (NRC): NOT LESS THAN 0.65. <br />2.4 METAL SUSPENSION SYSTEM <br />A. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS <br />BY ONE OF THE FOLLOWING: <br />1. SEE FINISH LIST FOR SPECIFIED PRODUCT <br />B. METAL SUSPENSION-SYSTEM STANDARD: PROVIDE MANUFACTURER'S STANDARD, <br />DIRECT-HUNG, METAL SUSPENSION SYSTEM AND ACCESSORIES ACCORDING TO ASTM <br />C 635/C 635M AND DESIGNATED BY TYPE, STRUCTURAL CLASSIFICATION, AND FINISH <br />INDICATED. <br />C. WIDE-FACE, CAPPED, DOUBLE-WEB ALUMINUM SUSPENSION SYSTEM: MAIN AND CROSS <br />RUNNERS ROLL FORMED FROM ALUMINUM SHEET; PREPAINTED, WITH PREFINISHED <br />15/16-INCH- WIDE ALUMINUM CAPS ON FLANGES. <br />1. STRUCTURAL CLASSIFICATION: HEAVY-DUTY SYSTEM. <br />2. END CONDITION OF CROSS RUNNERS: BUTT-EDGE TYPE. <br />3. FACE DESIGN: FLAT, FLUSH. <br />4. CAP MATERIAL: ALUMINUM. <br />5. CAP FINISH: PAINTED WHITE. <br />2.5 ACCESSORIES <br />A. ATTACHMENT DEVICES: SIZE FOR FIVE TIMES THE DESIGN LOAD INDICATED IN ASTM C <br />635/C 635M, TABLE 1, "DIRECT HUNG," UNLESS OTHERWISE INDICATED. COMPLY WITH <br />SEISMIC DESIGN REQUIREMENTS. <br />1. ANCHORS IN CONCRETE: ANCHORS OF TYPE AND MATERIAL INDICATED <br />BELOW, WITH HOLES OR LOOPS FOR ATTACHING HANGERS OF TYPE INDICATED <br />AND WITH CAPABILITY TO SUSTAIN, WITHOUT FAILURE, A LOAD EQUAL TO FIVE <br />TIMES THAT IMPOSED BY CEILING CONSTRUCTION, AS DETERMINED BY <br />TESTING ACCORDING TO ASTM E 488/E 488M OR ASTM E 1512 AS APPLICABLE, <br />CONDUCTED BY A QUALIFIED TESTING AND INSPECTING AGENCY. <br />A. TYPE: POSTINSTALLED EXPANSION, OR POSTINSTALLED BONDED <br />ANCHORS. <br />B. CORROSION PROTECTION: CARBON-STEEL COMPONENTS ZINC <br />PLATED ACCORDING TO ASTM B 633, CLASS SC 1 (MILD) SERVICE <br />CONDITION. <br />2. POWER-ACTUATED FASTENERS IN CONCRETE: FASTENER SYSTEM OF TYPE SUITABLE FOR <br />APPLICATION INDICATED, FABRICATED FROM CORROSION-RESISTANT MATERIALS, WITH <br />CLIPS OR OTHER ACCESSORY DEVICES FOR ATTACHING HANGERS OF TYPE INDICATED <br />AND WITH CAPABILITY TO SUSTAIN, WITHOUT FAILURE, A LOAD EQUAL TO 10 TIMES THAT <br />IMPOSED BY CEILING CONSTRUCTION, AS DETERMINED BY TESTING ACCORDING TO <br />ASTM E 1190, CONDUCTED BY A QUALIFIED TESTING AND INSPECTING AGENCY. <br />SECTION 09 6800 CARPET TILE <br />PART 1 - GENERAL <br />1.01 SUMMARY <br />A. SECTION INCLUDES: <br />1. CARPET TILE AS INDICATED. <br />B. RELATED REQUIREMENTS: <br />1. DIVISION 01 - GENERAL REQUIREMENTS <br />2. SECTION 09 6513 - RUBBER BASE. <br />1.02 SUBMITTALS <br />A. SHOP DRAWINGS: SUBMIT DIMENSIONED LAYOUT OF CARPET SEAMING AND DETAILS <br />FOR BINDER BARS. <br />B. SAMPLES: <br />1. SUBMIT ONE LABELED SAMPLE. SAMPLES SHALL BE MINIMUM 24-INCH SQUARE <br />WITH PROPER BACKING. <br />2. TRIM AND ACCESSORIES: SUBMIT 12-INCH LONG SAMPLES OF EACH TYPE TRIM <br />PROPOSED FOR THE WORK. <br />C. PRODUCT DATA: SUBMIT THE FOLLOWING: <br />1. CARPET MANUFACTURER'S PUBLISHED TECHNICAL DATA FULLY DESCRIBING C <br />CARPET MATERIALS, CONSTRUCTION, AND RECOMMENDED INSTALLATION <br />DIRECTIONS. <br />2. TECHNICAL DATA AND INSTALLATION INSTRUCTIONS FOR EACH ADHESIVE AND <br />SEALER MATERIAL. <br />3. CARPET MANUFACTURER'S PUBLISHED INSTRUCTIONS FOR MAINTENANCE, <br />CARE, CLEANING AND REPAIR OF CARPET. <br />4. MSDS ON MANUFACTURER’S RECOMMENDED ADHESIVES, SEAM AND EDGE <br />SEALERS AND PRIMERS. <br />D. CERTIFICATE: <br />1. SUBMIT A CERTIFICATE FROM CARPET MANUFACTURER THAT MATERIALS <br />SUPPLIED COMPLY WITH FIRE HAZARD RESISTANCE STANDARDS SPECIFIED. <br />2. SUBMIT A MANUFACTURER CERTIFICATION THAT THE INSTALLER IS APPROVED <br />BY THE MANUFACTURE TO INSTALL THE SPECIFIED PRODUCT. <br />E. INSTALLER’S/SUBCONTRACTOR’S EXPERIENCE QUALIFICATIONS: SUBMIT LIST OF NOT <br />LESS THAN FIVE PROJECTS WITH SIMILAR SCOPE OF WORK, EXTENDING OVER PERIOD <br />OF NOT LESS THAN FIVE YEARS, INDICATING INSTALLER’S EXPERIENCE RECORD. <br />1.03 QUALITY ASSURANCE <br />A. COMPLY WITH THE FOLLOWING AS A MINIMUM REQUIREMENT: <br />1. MATERIALS SHALL COMPLY WITH CBC CHAPTER 11B AND ADAAG <br />REQUIREMENTS. <br />2. MANUFACTURER’S INSTALLATION INSTRUCTIONS. <br />3. COMPLY WITH CURRENT CHPS REQUIREMENTS FOR LOW EMITTING <br />MATERIALS, WWW.CHPS.NET. <br />4. CHEMICALLY BASED PRODUCTS SUCH AS SEALERS, PRIMERS, FILLERS, <br />ADHESIVES, ETCETERA MUST BE APPROVED BY KAISER PERMANENTE. <br />5. CARPET MUST BE FREE OF ANTI-MICROBIAL PROTECTION (DRY BACK SYSTEM). <br />6. COMPLY WITH ASTM F1869 FOR MOISTURE TESTING. <br />B. REQUIREMENTS OF REGULATORY AGENCIES: CARPETING SHALL MEET REQUIREMENTS <br />OF FEDERAL, STATE AND LOCAL REGULATORY AGENCIES FOR FLAMMABILITY, STATIC <br />CONTROL, OR OTHER PROPERTIES AS SPECIFIED, WITH TESTING DOCUMENTATION <br />FROM THE MANUFACTURER BY A THIRD PARTY LABORATORY. <br />C. CARPET TILE INSTALLATION: COMPLY WITH CRI 104 - STANDARD FOR INSTALLATION OF <br />TEXTILE FLOOR COVERING MATERIALS. <br />D. EACH COLOR OF CARPET SHALL BE OF THE SAME DYE LOT. <br />E. PRE-INSTALLATION AND PROGRESS MEETINGS: PRIOR TO START OF WORK OF THIS <br />SECTION AND AFTER APPROVAL OF SUBMITTALS, SCHEDULE AN ON SITE PRE- <br />INSTALLATION BETWEEN CONTRACTOR, SUPERVISING INSTALLER, OAR AND PROJECT <br />INSPECTOR TO REVIEW CONSTRUCTION DRAWINGS AND INSTALLATION PROCEDURES <br />IN ACCORDANCE WITH THE REQUIREMENTS OF THIS SPECIFICATION. <br />1.04 DELIVERY, STORAGE AND HANDLING <br />A FILL TILE PACKS PACKAGED AND IDENTIFIED BY THE FACTORY. DISTRIBUTOR, DEALER, <br />OR VENDOR CUTTING, RE-PACKAGING, AND RE-LABELING IS NOT PERMITTED. <br />B. STORE MATERIAL AT LEAST 24 HOURS AT ROOM TEMPERATURE PRIOR TO I <br />INSTALLATION AND IN ACCORDANCE TO MANUFACTURE’S INSTRUCTIONS. <br />C. DELIVER FIRE-RATED MATERIALS WITH TESTING AGENCY LABELS AND REQUIRED FIRE <br />CLASSIFICATION NUMBERS ATTACHED AND LEGIBLE. <br />1.05 JOB CONDITIONS <br />A. VENTILATION AND TEMPERATURE: VERIFY AREAS TO BE CARPETED ARE VENTILATED <br />TO REMOVE FUMES FROM INSTALLATION MATERIALS, AND AREAS ARE WITHIN TEMPERATURE <br />RANGE RECOMMENDED BY THE VARIOUS MATERIAL MANUFACTURERS FOR PROJECT SITE <br />INSTALLATION CONDITIONS. THE TEMPERATURE OF A CONCRETE SLAB MUST BE STABILIZED <br />ABOVE 65 DEGREES BOTH 12 HOURS PRIOR TO AND AFTER THE INSTALLATION. THE FOLLOWING <br />ENVIRONMENTAL CONDITIONS INSIDE THE BUILDING ARE CRITICAL FOR PROPER INSTALLATION. <br />TEMPERATURE MUST BE BETWEEN 65 DEGREES F AND 95 DEGREES F AND THE HUMIDITY <br />BETWEEN 10 PERCENT AND 65 PERCENT FOR AT LEAST 72 HOURS BEFORE AND 72 HOURS AFTER <br />INSTALLATION. IN ADDITION, ANY ADHESIVES, EDGE SEALERS AND SEAM SEALERS SHOULD BE <br />STORED UNDER THESE CONDITIONS FOR A MINIMUM OF 24 HOURS PRIOR TO INSTALLATION. <br />B. PROTECTION: PROHIBIT TRAFFIC ON CARPET FOR AT LEAST 12 HOURS AFTER <br />INSTALLATION. COVER CARPET WITH HEAVY NON-STAINING KRAFT PAPER IN AREAS WHERE THE <br />WORK OF OTHER TRADES IS TO BE PERFORMED AND IN TRAFFIC AND PASSAGE AREAS. <br />PROTECT CARPET FROM DAMAGE OR SOILING. MAINTAIN PROTECTION IN PLACE UNTIL <br />SUBSTANTIAL COMPLETION. <br />1.06 WARRANTY <br />A. INSTALLER SHALL PROVIDE A TWO YEAR INSTALLATION WARRANTY. <br />B. MANUFACTURER SHALL PROVIDE A LIFETIME COMMERCIAL LIMITED WARRANTY AS <br />DESCRIBED BELOW: <br />1. DELAMINATION WARRANTY: CARPET WILL NOT DELAMINATE FOR A MINIMUM <br />OF 30 YEARS FROM THE DATE OF INSTALLATION. <br />2. ZIPPERING WARRANTY: CARPET TILE WILL NOT ZIPPER OR DEVELOP <br />CONTINUOUS PILE YARN RUNNERS IN THE BODY OF THE CARPET FOR A <br />MINIMUM OF 30 YEARS FROM THE DATE OF SUBSTANTIAL COMPLETION. <br />3. EDGE RAVEL: CARPET TILE WILL NOT HAVE CONTINUOUS PILE YARN COMING <br />OUT AT SEAMS FOR A MINIMUM OF 30 YEARS FROM THE DATE OF <br />SUBSTANTIAL COMPLETION. <br />1.07 MAINTENANCE <br />A. EXTRA MATERIALS: PROVIDE MINIMUM 36 INCHES IN ANY ONE DIMENSION OF EXTRA <br />MATERIALS FOR EACH COLOR, PATTERN, AND DYE LOT OF CARPET. <br />. <br />9. CALCULATE AND REPORT RESULTS AS “POUNDS OF EMISSION PER 1,000 <br />SQUARE FEET PER 24 HOURS”. <br />10. MOISTURE VAPOR EMISSIONS MUST MEET MANUFACTURES <br />RECOMMENDATIONS PRIOR TO INSTALLATION. <br />D. QUANTIFYING PH LEVEL <br />1. AT EACH VAPOR EMISSION TEST SITE, AFTER REMOVAL OF TEST CONTAINMENT <br />DOME, PERFORM PH TEST. <br />A. PLACE SEVERAL DROPS OF WATER ONTO THE CONCRETE <br />SURFACE TO FORM A PUDDLE APPROXIMATELY 1 INCH IN <br />DIAMETER. <br />B. ALLOW THE WATER TO SET FOR APPROXIMATELY 60 <br />SECONDS. <br />C. DIP THE PH PAPER INTO THE WATER AND REMOVE <br />IMMEDIATELY, COMPARE COLOR TO CHART PROVIDED BY <br />PAPER SUPPLIER TO DETERMINE PH READING. <br />D. ACCEPTABLE RANGE IS PH 5 TO PH 9. EXCESSIVE ALKALINITY <br />SHALL BE NEUTRALIZED PRIOR TO INSTALLATION OF THE <br />CARPET. <br />E. RECORD AND REPORT RESULTS. <br />E. CLEANING AND DRYING: CLEAN CONCRETE FLOOR SLABS OF OIL, GREASE, WAXES, <br />CURING COMPOUNDS, DUST, DIRT, DEBRIS, PAINT, AND OTHER DELETERIOUS SUBSTANCES. <br />PROVIDE A COMMERCIAL VACUUM CLEANER TO REMOVE DUST AND DIRT. DAMP MOP TO REMOVE <br />DUST THAT MAY REMAIN AFTER FIRST VACUUMING, ALLOW SURFACE TO DRY, AND AGAIN <br />VACUUM; REPEAT PROCEDURE IF NECESSARY TO ELIMINATE DUST. DO NOT FURNISH OILED OR <br />CHEMICAL TREATED SAWDUST OR ANY SIMILAR PRODUCT FOR DUST REMOVAL. <br />F. LEVELING: VERIFY FLOOR SLABS TRUE TO LEVEL AND PLANE WITHIN A TOLERANCE OF <br />1/8 INCH IN 10 FEET. TEST FLOOR AREAS BOTH WAYS WITH A 10-FOOT STRAIGHTEDGE AND <br />REPAIR HIGH AND LOW AREAS EXCEEDING ALLOWABLE TOLERANCE. POP UPS SHALL BE <br />HAMMERED OUT AND FLOOR FILLED WITH A CEMENTITIOUS LEVELING COMPOUND. REMOVE HIGH <br />AREAS BY POWER SANDING, STONE RUBBING OR GRINDING, CHIPPING OFF AND FILLING WITH AN <br />APPROVED CEMENTITIOUS LEVELING COMPOUND, OR EQUIVALENT METHOD. FILL LOW AREAS <br />WITH A CEMENTITIOUS LEVELING COMPOUND. REPAIR AND LEVEL THE SURFACES HAVING <br />ABRUPT CHANGES IN PLANE, SUCH AS TROWEL MARKS OR RIDGES, WHETHER OR NOT WITHIN <br />THE ALLOWABLE TOLERANCE. AGAIN CLEAN AREAS WHERE REPAIRS ARE PERFORMED. DO NOT <br />SAND, STONE RUB GRIND OR POWER CHIP FLOOR ADHESIVES THAT CONTAIN ASBESTOS. <br />G. CONDITIONING OF MATERIALS: CARPET TILE AND ADHESIVES SHALL BE CONDITIONED <br />AT THE PROJECT SITE AT NOT LESS THAN 65 DEGREES F AND RELATIVE HUMIDITY BETWEEN 10 <br />PERCENT AND 65 PERCENT FOR 48 HOURS PRIOR TO INSTALLATION AND IN ACCORDANCE TO <br />MANUFACTURE’S INSTRUCTIONS. <br />3.03 CARPET TILE INSTALLATION <br />A. GENERAL: INSTALL CARPET IN ACCORDANCE WITH REQUIREMENTS OF CRI 104, EXCEPT <br />WHERE MORE STRINGENT REQUIREMENTS ARE SPECIFIED HEREIN OR RECOMMENDED B <br />BY CARPET MATERIALS MANUFACTURERS. <br />B. INSTALL CARPET ROLLS IN EACH DYE LOT IN THE NUMBER SEQUENCE AS FURNISHED BY <br />MANUFACTURER. ROLL OUT CARPET IN ONE DIRECTION AND DO NOT REVERSE <br />DIRECTION AT ANY LOCATIONS. ALIGN CARPET WITH CENTERLINE OF ROOM OR SPACE, <br />AND ADJUST AT EDGES FOR WALL VARIATIONS. <br />C. COLOR CONTROL: INSTALL DYE LOT IN THE NUMBER SEQUENCE AT LOCATIONS <br />INDICATED TO PREVENT SHADING VARIATIONS. INSTALL ONLY ONE DYE LOT FOR EACH <br />AREA OF BUILDING UNLESS OTHERWISE REVIEWED. IF MORE THAN ONE DYE LOT IS <br />REQUIRED, OBTAIN PRIOR REVIEW OF COLOR MATCH BETWEEN DYE LOTS AND, <br />OWNER’S WRITTEN APPROVAL. <br />D. CARPET RUNS: INSTALL CARPET IN ONE-PIECE LENGTHS BETWEEN PERMANENT WALLS <br />UNLESS OTHERWISE REQUIRED. SEAMS ARE PERMITTED ONLY WHERE SHOWN ON THE <br />LAYOUT SHOP DRAWINGS. INSTALL CORRIDOR CARPET IN ONE-PIECE SIZES FOR FULL <br />LENGTH AND WIDTH, CROSS SEAMING ONLY WHERE CORRIDORS CHANGE DIRECTION. <br />E. LAYING AND SEAMING: CUT CARPET FOR SEAMS BETWEEN TUFT ROWS AND PREVENT <br />DAMAGE TO TUFTS OR LOOPS, PREVENT EDGE RAVELS, AND PRESERVE UNIFORM TUFT <br />ROW ALIGNMENT AND SPACING ON BOTH SIDES AND ACROSS SEAMS. INSTALL CARPET <br />WITH TUFT OR LOOP ROWS IN STRAIGHT LINES BOTH WAYS, FREE OF OFFSETS, <br />WAVINESS, DISTORTION, OR MISALIGNMENT. CUT SEAM EDGES STRAIGHT AND SQUARE <br />WITH BACKING. TRIM CARPET AT WALLS, COLUMNS, AND PENETRATIONS FOR A <br />COMPRESSED FIT. <br />F. DOORWAYS: EXTEND CARPET INTO DOORWAYS WITHOUT PIECING IN AND SEAM TO THE <br />CARPET ON OTHER SIDE OF DOOR UNDER DOOR CENTERLINE EXCEPT WHERE METAL <br />THRESHOLDS OCCUR; NO SMALL FILLER PIECES OF CARPET WILL BE PERMITTED AT <br />DOORWAYS. <br />G. ADHESIVE INSTALLATION: DO NOT POWER STRETCH CARPET DURING INSTALLATION. <br />PROVIDE NOTCHED TROWEL AS REQUIRED BY ADHESIVE MANUFACTURER. EVENLY <br />SPREAD ADHESIVE FREE OF EXCESS OR THIN AREAS. PLACE AND ROLL CARPET WITHIN <br />OPEN TIME OF ADHESIVE. ROLL CARPET IN BOTH DIRECTIONS WITH A 75 POUNDS TO 100 <br />POUNDS TOWARDS OPEN SEAMS OR EDGES TO EXPEL TRAPPED AIR AND ASSURE THAT <br />100 PERCENT OF THE ADHESIVE TRANSFERS TO THE CARPET BACKING WHILE <br />MAINTAINING FULL COVERAGE ON THE FLOOR. <br />H. BINDER BARS: PROVIDE BARS AT EDGES OF CARPET NOT ABUTTING WALLS OR OTHER C <br />ONSTRUCTION, SECURELY FASTENED IN PLACE BY USING ALUMINUM DRIVE NAILS. <br />PRECISELY ALIGN SPLICES AND TIGHTLY MITER ANGLES. <br />3.04 PROTECTION <br />A. PROTECT THE WORK OF THIS SECTION UNTIL SUBSTANTIAL COMPLETION. PROHIBIT <br />TRAFFIC ON CARPET FOR AT LEAST 12 HOURS AFTER INSTALLATION. COVER CARPET <br />WITH HEAVY NON-STAINING KRAFT PAPER IN AREAS WHEN THE WORK OF OTHER T <br />TRADES IS TO BE PERFORMED AND IN TRAFFIC AND PASSAGE AREAS. PROTECT <br />CARPET FROM DAMAGE OR SOILING. MAINTAIN IN PLACE UNTIL SUBSTANTIAL C <br />COMPLETION. <br />3.05 CLEANING <br />A. AS EACH CARPETED AREA IS COMPLETED, CLEAN UP DIRT AND DEBRIS, REMOVE SPOTS <br />AND SOILING WITH PROPER CLEANER, TRIM OFF LOOSE THREADS WITH SHARP <br />SCISSORS, AND VACUUM ENTIRE AREA CLEAN. <br />3.06 CLEAN-UP <br />A. REMOVE RUBBISH, DEBRIS, AND WASTE MATERIALS AND LEGALLY DISPOSE OF OFF THE <br />PROJECT SITE. <br />3.07 INSTRUCTION <br />A. BEFORE SUBSTANTIAL COMPLETION OF THE WORK, PROVIDE A FOUR HOUR OWNER <br />INSTRUCTION PERIOD FOR PROPER MAINTENANCE OF CARPETING. INSTRUCTIONS <br />SHALL BE PROVIDED BY TECHNICAL REPRESENTATIVE OF MANUFACTURER. <br />END OF SECTION <br />SECTION 09 9000 - PAINTING AND COATING <br />PART 1 - GENERAL <br />1.1 SUMMARY: <br />A. WORK OF THIS SECTION INCLUDES: <br />1. TOUCHING UP OF SHOP-APPLIED PRIME COATS. <br />2. PREPARATION OF SURFACES TO RECEIVE FINISHES. <br />3. PAINTING, OR OTHERWISE FINISHING OF SURFACES, EXCEPT AS OTHERWISE <br />INDICATED. <br />1.2 DEFINITIONS: <br />A. DFT: DRY FILM THICKNESS OF THE COATING. <br />1.3 PERFORMANCE REQUIREMENTS: <br />A. DFT FOR EACH PRIMER, PAINT, SEALER AND STAIN SHALL BE AS RECOMMENDED BY <br />PRODUCT MANUFACTURER'S PRODUCT DATA. <br />B. VOC CONTENT: PAINTS, PRIMERS, AND SEALERS SHALL HAVE A VOC CONTENT LESS THAN <br />THE CURRENT VOC CONTENT LIMITS OF SOUTH COAST AIR QUALITY MANAGEMENT <br />DISTRICT (SCAQMD) RULE #1113, ARCHITECTURAL COATINGS, RULES IN EFFECT <br />JANUARY 1, 2004. <br />1.4 ACTION SUBMITTALS: <br />A. PRODUCT DATA: <br />1. SUBMIT COMPLETE LIST OF PRODUCTS PROPOSED <br />2. INDICATE MANUFACTURER, BRAND NAME, QUALITY, TYPE, AND SHEEN FOR EACH <br />TYPE OF PAINT AND FOR EACH SURFACE TO BE FINISHED. INDICATE VOC RATING <br />AND COMPLIANCE WITH APPLICABLE REGULATIONS. <br />3. INTENT OF CONTRACTOR TO USE PRODUCTS SPECIFIED DOES NOT RELIEVE HIM <br />FROM HIS RESPONSIBILITIES OF SUBMITTING PRODUCT LIST. <br />B. VERIFICATION SAMPLES: SUBMIT TWO SETS OF SELECTED COLOR SAMPLES FROM PAINT <br />MANUFACTURER FOR ARCHITECT'S REVIEW AND ACCEPTANCE. <br />1.5 QUALITY ASSURANCE: <br />A. APPLICABLE STANDARDS: <br />1. ASTM INTERNATIONAL (ASTM), AS REFERENCED HEREIN. <br />2. ENVIRONMENTAL PROTECTION AGENCY (EPA), VOLATILE ORGANIC COMPOUNDS <br />(VOC) STANDARDS AS REQUIRED BY LOCAL CODES AND REGULATIONS. <br />PART 2 - PRODUCTS <br />2.1 MANUFACTURERS: <br />A. ACCEPTABLE MANUFACTURERS: EXCEPT AS OTHERWISE NOTED, PRODUCTS SPECIFIED <br />AS A STANDARD OF QUALITY ARE MANUFACTURED BY BENJAMIN MOORE CO. <br />PRODUCTS OF THE FOLLOWING MANUFACTURERS SIMILAR IN TYPE AND QUALITY ARE <br />ACCEPTABLE FOR USE, SUBJECT TO APPROVAL OF PRODUCT LIST: <br />1. SEE FINISH LIST FOR SPECIFIED PRODUCT <br />B. WHERE PRODUCTS OTHER THAN THOSE OF THE MANUFACTURER LISTED AS THE <br />STANDARD OF QUALITY ARE SPECIFIED IN PAINTING SCHEDULE, SUCH PRODUCTS HAVE <br />BEEN SELECTED TO ACHIEVE SPECIFIC RESULTS AND SUBSTITUTIONS WILL BE ALLOWED <br />ONLY IN ACCORD WITH PRODUCT SUBSTITUTION PROCEDURES SECTION. <br />2.2 PAINTING MATERIALS: <br />A. MISCELLANEOUS MATERIALS: <br />1. PAINT THINNERS AND TINTS SHALL BE PRODUCTS OF SAME MANUFACTURER <br />AS PAINTS OR APPROVED BY HIM FOR USE WITH HIS PRODUCTS. <br />2. SHELLAC, TURPENTINE, PATCHING COMPOUNDS AND SIMILAR MATERIALS <br />REQUIRED FOR EXECUTION OF WORK SHALL BE PURE, BEST QUALITY <br />PRODUCTS. <br />B. PAINT AND STAIN COLORS SHALL BE AS INDICATED ON FINISH SCHEDULE WITH FINAL <br />APPROVAL BASED ON BRUSH-OUT SUBMITTAL. <br />PART 3 - EXECUTION <br />3.1 PREPARATION: <br />A. INCLUDE PAINTING REQUIRED BY PROJECT EXCEPT FOR PREFINISHED ITEMS AND <br />SPECIAL FINISHES AS SPECIFIED IN OTHER SECTIONS. <br />B. EXISTING SURFACES: <br />1. FOR PREVIOUSLY PAINTED SURFACES, REMOVE DIRT, DEBRIS AND CHALK BY <br />WASHING WITH DETERGENT AND WATER. <br />2. PREVIOUSLY PAINTED METAL SURFACES TO REMAIN SHALL BE WIRE-BRUSHED <br />AND CLEANED OF EXISTING PAINT AND RUST. <br />3. TREAT MILDEWED SURFACES WITH A SOLUTION OF ONE QUART <br />HYPOCHLORITE BLEACH TO A HALF CUP OF DETERGENT TO ONE GALLON <br />WATER. RINSE AND ALLOW TO DRY PRIOR TO PAINTING. <br />4. SCRAPE OR USE APPROPRIATE MEANS TO REMOVE ALL LOOSE, PEELING, <br />FLAKING, OR MARGINALLY ADHERING PAINT FROM THE SURFACE. FEATHER <br />SAND EDGES AS NECESSARY. <br />5. REPAIR OR REPLACE CAULKING WHERE NEEDED. <br />6. AFTER CLEANING, GLOSSY SURFACES SHALL BE DULLED BY SANDING. <br />REMOVE ALL SANDING DUST FROM THE SURFACE AFTER SANDING HAS TAKEN <br />PLACE. <br />7. PREPARE BARE AREAS AS NEW SURFACES, AND STOP PRIME OR FILL THOSE <br />AREAS WITH THE APPROPRIATE PRIMER OR FILLER. <br />8. PATCH OR REPAIR ALL CRACKS OR VOIDS WITH THE APPROPRIATE PATCHING <br />COMPOUND AND SAND SMOOTH AS NECESSARY. <br />9. SPOT PRIME ALL PATCHED AREAS WITH THE APPROPRIATE PRIMER PRIOR TO <br />FINISHING. <br />10. IF AFTER CLEANING CHALKY SURFACES CHALK RESIDUE IS STILL PRESENT, <br />PRIME THE ENTIRE SURFACE WITH THE PROPER BONDING PRIMER TO INSURE <br />GOOD ADHESION OF THE TOPCOAT TO THE SUBSTRATE. <br />C. WHERE FINISH MATERIALS ABUT OR ARE ABUTTED BY DISSIMILAR MATERIALS, CAULK <br />JOINTS IN ACCORD WITH JOINT SEALANTS SECTION. <br />D. GYPSUM BOARD: <br />1. FILL NARROW, SHALLOW CRACKS AND SMALL HOLES WITH PATCHING <br />COMPOUND, ALLOW TO DRY AND SAND SMOOTH WITHOUT RAISING NAP OF <br />GYPSUM BOARD PAPER. <br />2. GYPSUM BOARD SHALL BE FINISHED AS SPECIFIED IN GYPSUM BOARD <br />SECTION PRIOR TO PAINTING. <br />E. FERROUS METALS: <br />1. WIRE-BRUSH OR SANDPAPER TO REMOVE RUST AND MILL SCALE. <br />2. SOLVENT-CLEAN WITH XYLOL TO REMOVE GREASE, OIL AND CONTAMINANTS. <br />WIPE DRY WITH CLEAN CLOTH. <br />3.2 APPLICATION: <br />A. APPLY PAINT ONLY WHEN MOISTURE CONTENT OF SURFACES IS WITHIN LIMITS <br />RECOMMENDED IN PRODUCT DATA. APPLY PAINT MATERIALS USING CLEAN BRUSHES, <br />ROLLERS OR SPRAYING EQUIPMENT. <br />B. APPLY MATERIALS AT RATE NOT EXCEEDING THAT RECOMMENDED IN PRODUCT DATA <br />FOR SURFACE BEING PAINTED, LESS TEN PERCENT FOR LOSSES. <br />C. COMPLY WITH PRODUCT DATA FOR DRYING TIME BETWEEN COATS. <br />D. SAND AND DUST BETWEEN COATS TO REMOVE DEFECTS VISIBLE FROM A DISTANCE OF <br />5'-0". <br />E. FINISH COATS SHALL BE SMOOTH, FREE OF BRUSH MARKS, STREAKS, LAPS OR PILE-UP <br />OF PAINT, SKIPPED OR MISSED AREAS. <br />F. MAKE EDGES OF PAINT ADJOINING OTHER MATERIALS OR COLORS CLEAN AND SHARP <br />WITHOUT OVERLAPPING. <br />G. PRIMER COATS MAY BE OMITTED FOR SURFACES SPECIFIED TO RECEIVE FACTORY-APPLIED <br />PRIMER, IF PRIMER IS COMPATIBLE WITH FINISH COATS. IF PRIMER COATS ARE NOT COMPATIBLE, <br />SUBSTITUTE A BOND COAT AS RECOMMENDED BY PAINT MANUFACTURER FOR SPECIFIED PRIMER <br />COAT. <br />H. WHERE TWO-COAT FINISH IS SPECIFIED, PRIME COAT SHALL BE TINTED TO <br />APPROXIMATE FINISH COLOR. <br />I. WHERE PORTION OF FINISH ON GYPSUM BOARD PARTITION IS DAMAGED OR <br />UNACCEPTABLE, REFINISH ENTIRE SURFACE OF PARTITION. <br />J. SEAL TOPS AND BOTTOMS OF INTERIOR DOORS WITH PRIME COAT ONLY; SIDE EDGES <br />SAME AS FACES. <br />K. REMOVE AND PROTECT HARDWARE, ACCESSORIES, DEVICE PLATES, LIGHTING <br />FIXTURES, FACTORY-FINISHED WORK AND SIMILAR ITEMS, OR PROVIDE IN-PLACE <br />PROTECTION. UPON COMPLETION OF EACH SPACE, REPLACE REMOVED ITEMS. <br />L. PAINT EXPOSED PIPING AND DUCKWORK IN PAINTED SPACES SAME AS ADJACENT <br />WALL SURFACES. <br />M. THE FOLLOWING SURFACES DO NOT REQUIRE PAINTING: <br />1. PREFINISHED AND FACTORY-FINISHED SURFACES AND ITEMS, EXCEPT WHERE <br />INDICATED OTHERWISE. <br />2. CONCEALED DUCKWORK, CONDUIT AND PIPING. <br />3.3 PAINT SCHEDULES: <br />A. INTERIOR PAINT SCHEDULE: <br />1. GYPSUM BOARD: PROVIDE THE FOLLOWING FINISH SYSTEMS OVER INTERIOR <br />GYPSUM BOARD SURFACES: <br />A. LOW-LUSTER ACRYLIC EGGSHELL FINISH: <br />1) FIRST COAT OVER BARE DRYWALL: MOORE #023 FRESH START <br /> ACRYLIC LATEX PRIMER 50 g/L 1.3 MILS DFT. <br />2) FIRST COAT OVER PREVIOUSLY PAINTED DRYWALL: MOORE <br /> #SXA-110 STIX WATERBORNE BONDING PRIMER 40% VOL SOLIDS, <br /> 2.1 MILS DFT. <br />3) SECOND COAT: MOORE #N538 ULTRA SPEC 500, ZERO VOC,ACRYLIC <br /> EGGSHELL ENAMEL, 1.8 MILS DFT. <br />4) THIRD COAT: MOORE #N538 ULTRA SPEC 500, ZERO VOC, <br /> ACRYLIC EGGSHELL ENAMEL, 1.8 MILS DFT. <br />2. FERROUS METAL: PROVIDE THE FOLLOWING FINISH SYSTEMS OVER NEW AND <br />PREVIOUSLY PAINTED FERROUS METAL: <br />A. SEMI-GLOSS ACRYLIC ENAMEL FINISH: <br />1) FIRST COAT: MOORE #P04 SUPER SPEC HP ACRYLIC METAL <br />PRIMER 54 g/L, 2.3 MILS DFT. <br />2) SECOND COAT: MOORE #P29 SUPER SPEC HP ACRYLIC DTM <br />SEMI-GLOSS ENAMEL, 206 g/L, 2.5 MILS DFT. <br />3) THIRD COAT: MOORE #P29 SUPER SPEC HP ACRYLIC DTM <br />SEMI-GLOSS ENAMEL, 206 g/L, 2.5 MILS DFT. <br />3. ZINC-COATED METAL: PROVIDE THE FOLLOWING FINISH SYSTEMS OVER NEW <br />AND PREVIOUSLY PAINTED INTERIOR ZINC-COATED METAL SURFACES: <br />A. SEMI-GLOSS ACRYLIC ENAMEL FINISH: <br />1) FIRST COAT: MOORE #P04 SUPER SPEC HP ACRYLIC METAL <br />PRIMER 54 g/L, 2.3 MILS DFT. <br />2) SECOND COAT: MOORE #P29 SUPER SPEC HP ACRYLIC DTM <br />SEMI-GLOSS ENAMEL, 206 g/L, 2.5 MILS DFT. <br />3) THIRD COAT: MOORE #P29 SUPER SPEC HP ACRYLIC DTM <br />SEMI-GLOSS ENAMEL, 206 g/L, 2.5 MILS DFT. <br />4. ALUMINUM: PROVIDE THE FOLLOWING FINISH SYSTEMS OVER NEW AND <br />PREVIOUSLY PAINTED INTERIOR ALUMINUM METAL SURFACES: <br />A. SEMI-GLOSS ACRYLIC ENAMEL FINISH: <br />1) FIRST COAT: MOORE #SXA-110 STIX BONDING PRIMER 40% <br />VOL. SOLIDS, 2.1 MILS DFT. <br />2) SECOND COAT: MOORE #P29 SUPER SPEC HP ACRYLIC DTM <br />SEMI-GLOSS ENAMEL, 206 g/L, 2.5 MILS DFT. <br />3) THIRD COAT: MOORE #P29 SUPER SPEC HP ACRYLIC DTM <br />SEMI-GLOSS ENAMEL, 206 g/L, 2.5 MILS DFT. <br />END OF SECTION <br />PART 2 - PRODUCTS <br />2.01 MANUFACTURERS AND PRODUCTS <br />A. CARPETING: <br />1. BASIS OF DESIGN: PER FINISH LIST <br />B. ADHESIVES AND PRIMERS: AS RECOMMENDED BY TILE CARPETING <br />MANUFACTURER AND APPROVED BY KAISER PERMANENTE. <br />2.02 MATERIALS <br />A. CARPET SHALL MEET THE FOLLOWING MINIMUM STANDARDS: <br />1. GAUGE: 1/12 <br />2. FIBER: ECO SOLUTION Q NYLON – 92% SOLUTION DYED, 8% YARN DYED <br />3. CONSTRUCTION: MULTI-LEVEL PATTERN LOOP. ECOWORX TILE SECONDARY <br />BACKING. 11 STITCHES/INCH <br />4. TUFTED WEIGHT: MINIMUM 22 OUNCES PER SQUARE YARD. THIS WEIGHT <br />EXCLUDES BACKING. <br />5. WARRANTY: LIFETIME LIMITED COMMERCIAL WARRANTY <br />6. FLAMMABILITY: <br />A. FLOORING RADIANT PANEL: CLASS I- PER ASTM E648. <br />B. NBS SMOKE DENSITY: LESS THAN 450 PER TEST ASTM E662; NFPA <br />258 <br />C. FLAME RESISTANT: SHALL PASS METHENAMINE PILL TEST ASTM <br />E662. <br />D. MATERIALS SHALL MEET REQUIREMENTS OF CALIFORNIA <br />PROPOSITION 65. IN CASE OF FIRE, NO MATERIAL SHALL BE USED THAT EMIT <br />GAS AND IS PROHIBITED BY CALIFORNIA PROPOSITION 65. <br />7. RUN RESISTANT STRENGTH: NOT LESS THAN 25 POUNDS, IN ACCORDANCE <br />WITH THE LOOP PILE RUN RESISTANCE TEST (TP 155), WET OR DRY FOR A <br />MINIMUM OF 30 YEARS. <br />8. INDOOR AIR QUALITY: CARPET SHALL MEET OR EXCEED CRI AND EPA <br />GUIDELINES (GREEN LABEL CERTIFIED AND LABELED) AND MAY NOT CONTAIN <br />ANY VOCS SUCH AS: 4 PCH (4 PHENULCYCLOHEXENE), PVC (POLYVINYL <br />CHLORIDE) OR SBR LATEX (STYRENE BUTADIENE RUBBER). <br />9. RECYCLING OF EXISTING CARPET: IF PROJECT SCOPE INCLUDED REMOVAL <br />AND DISPOSAL OF EXISTING CARPET, CONTRACTOR IS RESPONSIBLE FOR <br />DELIVERY TO A CERTIFIED RECYCLING CENTER. A RECYCLING CERTIFICATE <br />MUST BE SUBMITTED TO OAR, WITH ITS NAME AND ADDRESS OF LOCATION OF <br />RECYCLING CENTER, DATE AND WEIGHT OF CARPET RECYCLED. CONTRACTOR <br />IS RESPONSIBLE FOR COSTS ASSOCIATED WITH RECYCLING. <br />B. CARPET TILE SHALL BE FROM ONE DYE LOT. <br />C. FULL AND CUT ROLLS OF CARPET SHALL BE CUT, PACKAGED, AND IDENTIFIED BY THE <br />FACTORY. DISTRIBUTORS, DEALERS AND VENDOR CUTTING, RE-PACKAGING, AND RE- <br />LABELING IS NOT PERMITTED. <br />F. ADHESIVE: WATER-RESISTANT LATEX-BASED ADHESIVE RECOMMENDED BY CARPET <br />MANUFACTURER FOR DIRECT GLUE-DOWN CARPET INSTALLATION. WHERE PRIMERS OR <br />SEALERS ARE FURNISHED, VERIFY THEIR COMPATIBILITY WITH ADHESIVE. <br />G. PATCHING COMPOUNDS: CEMENTITIOUS TYPE, ARDEX SD-F, DURABOND’S WEBCRETE # <br />95, OR EQUAL, AS RECOMMENDED BY CARPET MANUFACTURER. <br />PART 3 - EXECUTION <br />3.01 EXAMINATION <br />A. BEFORE INSTALLATION IS STARTED, EXAMINE SURFACES TO RECEIVE CARPET. <br />DEFICIENCIES SHALL BE CORRECTED BEFORE STARTING WORK OF THIS SECTION. <br />B. FIELD VERIFY DIMENSIONS AND OTHER CONDITIONS AFFECTING THIS WORK BEFORE <br />COMMENCING CARPET INSTALLATION. <br />3.02 PREPARATION <br />A. PROVIDE CONCRETE MOISTURE VAPOR EMISSION AND PH TESTING FOR CONCRETE <br />SPECIFIED TO BE COVERED WITH CARPET. INCLUDES CONCRETE PLACED BELOW, ON AND <br />ABOVE GRADE. FOR CARPET REPLACEMENT PROJECTS, CONCRETE SLABS NOT IN DIRECT <br />CONTACT WITH GROUND MAY BE EXCLUDED FROM THIS REQUIREMENT. COMPLY WITH <br />REQUIREMENTS OF ASTM F1869. <br />B. TESTING SHALL TAKE PLACE AFTER ALLOWING CONCRETE TO DRY FOR A MINIMUM OF <br />90 DAYS. TESTING TO BE SCHEDULED NO LESS THAN 1 OR MORE THAN 3 WEEKS PRIOR TO <br />SCHEDULED FLOORING INSTALLATION. <br />C. QUANTIFICATION OF CONCRETE MOISTURE VAPOR EMISSION <br />1. THE TEST SITE SHOULD BE MAINTAINED AT THE SAME TEMPERATURE AND <br />HUMIDITY CONDITIONS AS THOSE ANTICIPATED DURING NORMAL OCCUPANCY. <br />THESE TEMPERATURE AND HUMIDITY LEVELS SHOULD BE MAINTAINED FOR 48 <br />HOURS PRIOR AND DURING TEST PERIOD. IF MEETING THIS CRITERIA IS NOT <br />POSSIBLE, THEN MINIMUM CONDITIONS SHOULD BE 75 PLUS OR MINUS 10 <br />DEGREES F AND 50 PLUS OR MINUS 10 PERCENT RELATIVE HUMIDITY. WHEN A <br />BUILDING IS NOT UNDER HVAC CONTROL, A RECORDING HYGROMETER OR <br />DATA LOGGER SHALL BE IN PLACE RECORDING CONDITIONS DURING THE TEST <br />PERIOD. A TRANSCRIPT OF THIS INFORMATION MUST BE INCLUDED WITH THE <br />TEST REPORT. <br />2. THE NUMBER OF VAPOR EMISSION TEST SITES IS DETERMINED BY THE <br />SQUARE FOOTAGE OF THE FACILITY. THE MINIMUM NUMBER OF TESTS TO BE <br />PLACED IS EQUAL TO THREE IN THE FIRST 1,000 SQUARE FEET AND ONE PER E <br />ACH ADDITIONAL 1,000 SQUARE FEET. <br />3. TEST SITES ARE TO BE CLEANED OF ADHESIVE RESIDUE, CURING <br />COMPOUNDS, PAINTS, SEALERS, FLOOR COVERINGS, ETCETERA 24 HOURS P <br />RIOR TO THE PLACEMENT OF TEST KITS. <br />4. WEIGH TEST DISH ON SITE PRIOR TO START OF TEST. SCALE MUST REPORT <br />WEIGHT TO 0.1 GRAMS. RECORD WEIGHT AND START TIME. <br />5. EXPOSE CALCIUM CHLORIDE AND SET DISH ON CONCRETE SURFACE. <br />6. INSTALL TEST CONTAINMENT DOME AND ALLOW TEST TO PROCEED FOR 72 <br />HOURS. <br />7. RETRIEVE TEST DISH BY CAREFULLY CUTTING THROUGH CONTAINMENT D <br />OME. CLOSE AND RESEAL TEST DISH. <br />8. WEIGH TEST DISH ON SITE RECORDING WEIGHT AND STOP TIME. <br />R <br />No. <br />F <br />LICENSE <br />STATE <br />D <br />O <br />A RCHITECT <br />C AL IFORNIA <br />STEPHE WHITE <br />RENEWAL <br />DATE <br />C-34829 <br />N <br />08/31/27 <br />SHEET TITLE <br />PROJECT <br />FACILITY <br />FAC NO: BLDG NO: FLOOR LEV: SECTION: <br />KP PROJ. NO. <br />PERMIT NO. <br />555 W. Fifth Street Suite 2950 | Los Angeles, CA 90013 USA <br />ARCHITECT <br />CONSULTANT <br />ARCHITECT SEAL CONSULTANT SEAL <br />KAISER FOUNDATION HOSPITALS <br />NATIONAL FACILITIES SERVICES <br />1800 HARRISON STREET OAKLAND, <br />CALIFORNIA 94612 <br />ISSUE / REVISION LOG <br />NO. ISSUED DATE <br />0 <br />5' <br /> <br />5 <br />0 <br />' <br />GR <br />A <br />P <br />H <br />I <br />C <br /> <br />S <br />C <br />A <br />L <br />E <br />S <br />: <br /> <br />1 <br />/ <br />1 <br />6 <br />" <br /> <br />= <br /> <br />1 <br />' <br />- <br />0 <br />" <br />0 <br />25 <br />' <br />1/ <br />8 <br />" <br /> <br />= <br /> <br />1 <br />' <br />- <br />0 <br />" <br />5' <br />0 <br />12 <br />' <br />1/ <br />4 <br />" <br /> <br />= <br /> <br />1 <br />' <br />- <br />0 <br />" <br />1' <br />0 <br />6' <br />1/ <br />2 <br />" <br /> <br />= <br /> <br />1 <br />' <br />- <br />0 <br />" <br />1' <br />0 <br />2' <br />1- <br />1 <br />/ <br />2 <br />" <br /> <br />= <br /> <br />1 <br />' <br />- <br />0 <br />" <br />0 <br />1' <br />3" <br /> <br />= <br /> <br />1 <br />' <br />- <br />0 <br />" <br />IF <br /> <br />T <br />H <br />I <br />S <br /> <br />S <br />H <br />E <br />E <br />T <br /> <br />I <br />S <br /> <br />N <br />O <br />T <br /> <br />30 <br />" <br />x <br />4 <br />2 <br />" <br />, <br /> <br />I <br />T <br /> <br />I <br />S <br /> <br />A <br /> <br />R <br />E <br />D <br />U <br />C <br />E <br />D <br /> <br />PR <br />I <br />N <br />T <br /> <br />- <br /> <br />S <br />C <br />A <br />L <br />E <br /> <br />AC <br />C <br />O <br />R <br />D <br />I <br />N <br />G <br />L <br />Y <br />AGENCY APPLICATION NUMBER <br />AGENCY APPROVAL STAMP <br />THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS <br />NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION. <br />HZ PROJ. NO. <br />www.huitt-zollars.com <br />Phone 310.820.4600 | Fax 310.207.4215 <br />C: <br />\ <br />U <br />s <br />e <br />r <br />s <br />\ <br />l <br />r <br />o <br />b <br />i <br />n <br />s <br />o <br />n <br />\ <br />O <br />n <br />e <br />D <br />r <br />i <br />v <br />e <br /> <br />- <br /> <br />H <br />u <br />i <br />t <br />t <br />- <br />Z <br />o <br />l <br />l <br />a <br />r <br />s <br />, <br /> <br />I <br />n <br />c <br />\ <br />D <br />o <br />cu <br />m <br />e <br />n <br />t <br />s <br />\ <br />R <br />3 <br />1 <br />4 <br />4 <br />1 <br />2 <br />. <br />3 <br />5 <br /> <br />K <br />P <br /> <br />H <br />B <br />M <br /> <br />K <br />P <br />O <br />J <br />_ <br />A <br />2 <br />4 <br />_ <br />l <br />r <br />o <br />b <br />i <br />n <br />s <br />o <br />n <br />L <br />2 <br />M <br />D <br />X <br />. <br />r <br />vt <br />1 <br />1 <br />/ <br />3 <br />/ <br />2 <br />0 <br />2 <br />5 <br /> <br />3 <br />: <br />4 <br />4 <br />: <br />0 <br />3 <br /> <br />P <br />M <br />SOCC 2022 R HBM 1st Fl KPOJ <br />REMODEL <br />G0-04 <br />SPECIFICATIONS <br />CA394-1 - <br />CAP027721R314412.35 <br />HARBOR/MacARTHUR MEDICAL OFF <br />3401 S. HARBOR BLVD. <br />SANTA ANA, CALIFORNIA 92704 <br />N/ASPECIFICATIONS - DIVISION 9 CONT.09 <br />CITY SUBMITTAL 11/03/2025 <br />101125520, 20187249, 40140902