<br /> <br /> Page 95 of 111 <br /> <br />Report No.: 2410B0143SHA-001 <br /> <br />TRF No. ANSI/CAN/UL 9540A_Unit <br /> <br />Attachment 7 Heat flux measurements <br /> <br />A total of 8 water-cooled Schmidt-Boelter gauges were used to measure heat flux from the initiating module <br />and initiating unit. <br /> <br />2 gauges (HF1&HF2) were placed on the surface of instrumented wall A, 2 gauges (HF3&HF4) were placed <br />on the surface of instrumented wall B and 2 gauges (HF5&HF6) were placed on the surface of instrumented <br />wall C. <br /> <br />HF1 and HF2 were secured on the surface of instrumented wall A, collinear with vertical center line of <br />adjacent initiating unit rear surface, height is the same with upper surface of relief valves. <br /> <br />HF3 and HF4 were Secured on the surface of instrumented wall B, collinear with vertical center line of <br />adjacent initiating unit left surface, height is the same with upper surface of relief valves. <br /> <br />HF5 and HF6 were Secured on the surface of instrumented wall C, collinear with vertical center line of <br />adjacent initiating unit front surface, height is the same with upper surface of relief valves. <br /> <br />The detailed locations of heat flux are shown in below figure. <br /> <br /> <br /> <br />Location of heat flux sensors <br /> <br />