Laserfiche WebLink
A. ADMINISTRATION OF CONTRACT: PROVIDE ADMINISTRATIVE REQUIREMENTS FOR THE PROPER <br />COORDINATION AND COMPLETION OF WORK INCLUDING THE FOLLOWING: <br />1. SUPERVISORY PERSONNEL. <br />2. PRECONSTRUCTION CONFERENCE. <br />3. PROJECT MEETINGS <br />B. SUBMITTAL SCHEDULE: PREPARE SUBMITTAL SCHEDULE; COORDINATE WITH PROGRESS <br />SCHEDULE. <br />C. SCHEDULE OF VALUES: SUBMIT SCHEDULE OF VALUES. <br />D. SCHEDULE OF TESTS: SUBMIT SCHEDULE OF REQUIRED TESTS INCLUDING PAYMENT AND <br />RESPONSIBILITY. <br />E. PERFORM SURVEYS: LAY OUT THE WORK AND VERIFYING LOCATIONS DURING <br />CONSTRUCTION. PERFORM FINAL SITE SURVEY. <br />F. EMERGENCY CONTACTS: SUBMIT AND POST A LIST OF EMERGENCY TELEPHONE NUMBERS <br />AND ADDRESS FOR INDIVIDUALS TO BE CONTACTED IN CASE OF EMERGENCY. <br />G. RECORD DOCUMENTS: SUBMIT RECORD DRAWINGS AND SPECIFICATIONS; TO BE <br />MAINTAINED AND ANNOTATED BY CONTRACTOR AS WORK PROGRESSES. <br />H. TYPES OF SUBMITTALS: PROVIDE TYPES OF SUBMITTALS LISTED IN INDIVIDUAL SECTIONS AND <br />NUMBER OF COPIES REQUIRED BELOW. <br />1. SHOP DRAWINGS, REVIEWED AND ANNOTATED BY THE CONTRACTOR - 2 COPIES. <br />2. PRODUCT DATA - 2 COPIES. <br />3. SAMPLES - 2, PLUS EXTRA SAMPLES AS REQUIRED TO INDICATE RANGE OF COLOR, <br />FINISH, AND TEXTURE TO BE EXPECTED. <br />4. INSPECTION AND TEST REPORTS - 2 COPIES. <br />5. WARRANTIES - 2 COPIES. <br />6. SURVEY DATA - 2 COPIES. <br />7. CLOSEOUT SUBMITTALS - 2 COPIES. <br />8. PROJECT PHOTOGRAPHS - 12 DIGITAL IMAGES EACH MONTH. SUBMIT CUMULATIVE <br />COPY AT EACH SUBSEQUENT SUBMITTAL. <br />I. SUBMITTAL PROCEDURES: COMPLY WITH PROJECT FORMAT FOR SUBMITTALS. COMPLY WITH <br />SUBMITTAL PROCEDURES ESTABLISHED BY ARCHITECT INCLUDING ARCHITECT'S SUBMITTAL AND <br />SHOP DRAWING STAMP. PROVIDE REQUIRED RESUBMITTALS IF ORIGINAL SUBMITTALS ARE NOT <br />APPROVED. PROVIDE DISTRIBUTION OF APPROVED COPIES INCLUDING MODIFICATIONS AFTER <br />SUBMITTALS HAVE BEEN APPROVED. <br />J. SAMPLES AND SHOP DRAWINGS: SAMPLES AND SHOP DRAWINGS SHALL BE PREPARED <br />SPECIFICALLY FOR THIS PROJECT. SHOP DRAWINGS SHALL INCLUDE DIMENSIONS AND DETAILS, <br />INCLUDING ADJACENT CONSTRUCTION AND RELATED WORK. NOTE SPECIAL COORDINATION <br />REQUIRED. NOTE ANY DEVIATIONS FROM REQUIREMENTS OF THE CONTRACT DOCUMENTS. <br />K. WARRANTIES: PROVIDE WARRANTIES AS SPECIFIED; WARRANTIES SHALL NOT LIMIT LENGTH OF <br />TIME FOR REMEDY OF DAMAGES OWNER MAY HAVE BY LEGAL STATUTE. CONTRACTOR, <br />SUPPLIER OR INSTALLER RESPONSIBLE FOR PERFORMANCE OF WARRANTY SHALL SIGN <br />WARRANTIES. <br />L. QUALITY MONITORING: MONITOR QUALITY CONTROL OVER SUPPLIERS, MANUFACTURERS, <br />PRODUCTS, SERVICES, SITE CONDITIONS, AND WORKMANSHIP, TO PRODUCE WORK OF <br />SPECIFIED QUALITY. PERFORM QUALITY CONTROL PROCEDURES AND INSPECTIONS DURING <br />INSTALLATION. <br />M. STANDARDS: COMPLY WITH SPECIFIED STANDARDS AS MINIMUM QUALITY FOR THE WORK <br />EXCEPT WHERE MORE STRINGENT TOLERANCES, CODES, OR SPECIFIED REQUIREMENTS <br />INDICATE HIGHER STANDARDS OR MORE PRECISE WORKMANSHIP. <br />N. TOLERANCES: MONITOR FABRICATION AND INSTALLATION TOLERANCE CONTROL OF <br />PRODUCTS TO PRODUCE ACCEPTABLE WORK. DO NOT PERMIT TOLERANCES TO <br />ACCUMULATE. COMPLY WITH MANUFACTURER'S TOLERANCES. <br />O. REFERENCE STANDARDS: FOR PRODUCTS OR WORKMANSHIP SPECIFIED BY ASSOCIATION, <br />TRADE, OR OTHER CONSENSUS STANDARDS, COMPLY WITH REQUIREMENTS OF THE <br />STANDARD, EXCEPT WHEN MORE RIGID REQUIREMENTS ARE SPECIFIED OR ARE REQUIRED BY <br />APPLICABLE CODES. <br />P. MANUFACTURER'S FIELD SERVICES: WHEN SPECIFIED IN INDIVIDUAL SPECIFICATION SECTIONS, <br />REQUIRE MATERIAL OR PRODUCT SUPPLIERS OR MANUFACTURERS TO PROVIDE QUALIFIED <br />STAFF PERSONNEL TO PERFORM THE FOLLOWING AS APPLICABLE, AND TO INITIATE <br />INSTRUCTIONS WHEN NECESSARY. <br />1. OBSERVE SITE CONDITIONS. <br />2. CONDITIONS OF SURFACES AND INSTALLATION. <br />3. QUALITY OF WORKMANSHIP. <br />4. START-UP OF EQUIPMENT. <br />5. TEST, ADJUST AND BALANCE OF EQUIPMENT. <br />Q. MOCK-UPS: ASSEMBLE AND ERECT SPECIFIED ITEMS WITH SPECIFIED ATTACHMENT AND <br />ANCHORAGE DEVICES, FLASHINGS, SEALS, AND FINISHES. ACCEPTED MOCK-UPS SHALL BE A <br />COMPARISON STANDARD FOR THE REMAINING WORK. <br />R. REMOVAL OF MOCK-UPS: WHERE MOCK-UP HAS BEEN ACCEPTED BY ARCHITECT AND NO <br />LONGER NEEDED, REMOVE MOCK-UP AND CLEAR AREA WHEN DIRECTED TO DO SO. <br />S. MANUFACTURES: PROVIDE PRODUCTS FROM ONE MANUFACTURER FOR EACH TYPE OR KIND <br />AS APPLICABLE. PROVIDE SECONDARY MATERIALS AS ACCEPTABLE TO MANUFACTURERS OF <br />PRIMARY MATERIALS. <br />T. PRODUCT SELECTION: PROVIDE PRODUCTS SELECTED OR EQUAL APPROVED BY ARCHITECT. <br />PRODUCTS SUBMITTED FOR SUBSTITUTION SHALL BE SUBMITTED WITH COMPLETE <br />DOCUMENTATION, AND INCLUDE CONSTRUCTION COSTS OF SUBSTITUTION INCLUDING <br />RELATED WORK. <br />U.SUBSTITUTIONS: REQUEST FOR SUBSTITUTION MUST BE IN WRITING. CONDITIONS FOR <br />SUBSTITUTION INCLUDE: <br />1.AN 'OR EQUAL' PHRASE IN THE SPECIFICATIONS. <br />2.SPECIFIED MATERIAL CANNOT BE COORDINATED WITH OTHER WORK. <br />3.SPECIFIED MATERIAL IS NOT ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION. <br />4.SUBSTANTIAL ADVANTAGE IS OFFERED TO THE OWNER IN TERMS OF COST, TIME, <br />OR OTHER VALUABLE CONSIDERATION. <br />V.SUBSTITUTION REQUESTS: SUBSTITUTIONS SHALL BE SUBMITTED PRIOR TO AWARD OF <br />CONTRACT, UNLESS OTHERWISE ACCEPTABLE. APPROVAL OF SHOP DRAWINGS, PRODUCT <br />DATA, OR SAMPLES CONTAINING SUBSTITUTIONS IS NOT AN APPROVAL OF A <br /> SUBSTITUTION UNLESS AN ITEM IS CLEARLY PRESENTED AS A SUBSTITUTION AT THE TIME OF <br /> SUBMITTAL. <br />W. SUBSTANTIAL COMPLETION: THE FOLLOWING ARE PREREQUISITES TO SUBSTANTIAL <br />COMPLETION. PROVIDE THE FOLLOWING. <br />1. PUNCH LIST PREPARED BY CONTRACTOR AND SUBCONTRACTORS AS APPLICABLE. <br />2. SUPPORTING DOCUMENTATION. <br />3. WARRANTIES. <br />4. CERTIFICATIONS. <br />5. OCCUPANCY PERMIT. <br />6. START-UP AND TESTING OF BUILDING SYSTEMS. <br />7. CHANGE OVER OF LOCKS. <br />8. METER READINGS. <br />9. COMMISSIONING DOCUMENTATION. <br />X. FINAL ACCEPTANCE: PROVIDE THE FOLLOWING PREREQUISITES TO FINAL ACCEPTANCE. <br />1. FINAL PAYMENT REQUEST WITH SUPPORTING AFFIDAVITS. <br />2. COMPLETED PUNCH LIST. <br />Y. AS-BUILT DRAWINGS: PROVIDE A MARKED-UP SET OF DRAWINGS INCLUDING CHANGES, <br />WHICH OCCURRED DURING CONSTRUCTION. <br />Z. PROJECT CLOSEOUT: PROVIDE THE FOLLOWING DURING PROJECT CLOSEOUT. <br />1. SUBMISSION OF RECORD DOCUMENTS. <br />2. SUBMISSION OF MAINTENANCE MANUALS. <br />3. TRAINING AND TURNOVER TO OWNER'S PERSONNEL. <br />4. FINAL CLEANING AND TOUCH-UP. <br />5. REMOVAL OF TEMPORARY FACILITIES. <br />AA. CUTTING AND PATCHING: PROVIDE CUTTING AND PATCHING WORK TO PROPERLY COMPLETE <br />THE WORK OF THE PROJECT, COMPLYING WITH PROJECT REQUIREMENTS FOR: <br />1. STRUCTURAL WORK. <br />2. MECHANICAL/ELECTRICAL SYSTEMS. <br />3. VISUAL REQUIREMENTS, INCLUDING DETAILING AND TOLERANCES. <br />4. OPERATIONAL AND SAFETY LIMITATIONS. <br />5. FIRE RESISTANCE RATINGS. <br />6. INSPECTION, PREPARATION, AND PERFORMANCE. <br />7. CLEANING. <br />BB. MEANS AND METHODS: DO NOT CUT AND PATCH IN A MANNER THAT WOULD RESULT IN A <br />FAILURE OF THE WORK TO PERFORM AS INTENDED, DECREASE ENERGY PERFORMANCE, <br />INCREASE MAINTENANCE, DECREASE OPERATIONAL LIFE, OR DECREASE SAFETY PERFORMANCE. <br />CC. INSPECTION: INSPECT CONDITIONS PRIOR TO WORK TO IDENTIFY SCOPE AND TYPE OF <br />WORK REQUIRED. PROTECT ADJACENT WORK. NOTIFY OWNER OF WORK REQUIRING <br />INTERRUPTION TO BUILDING SERVICES OR OWNER'S OPERATIONS. <br />DD. PERFORMANCE OF OPERATIONS: PERFORM WORK WITH WORKMEN SKILLED IN THE TRADES <br />INVOLVED. PREPARE SAMPLE AREA OF EACH TYPE OF WORK FOR APPROVAL. <br />EE. CUTTING: USE CUTTING TOOLS, NOT CHOPPING TOOLS. MAKE NEAT HOLES. MINIMIZE <br />DAMAGE TO ADJACENT WORK. INSPECT FOR CONCEALED UTILITIES AND STRUCTURE BEFORE <br />CUTTING. <br />FF. PATCHING: MAKE PATCHES, SEAMS, AND JOINTS DURABLE AND INCONSPICUOUS. COMPLY <br />WITH TOLERANCES FOR NEW WORK. <br />GG.CLEANING: CLEAN WORK AREA AND AREAS AFFECTED BY CUTTING AND PATCHING <br />OPERATIONS. <br />HH. CODES AND REGULATIONS: COMPLY WITH GOVERNING CODES AND REGULATIONS. USE <br />EXPERIENCED WORKERS. <br />II. OCCUPANCY: IMMEDIATE AREAS OF WORK WILL NOT BE OCCUPIED DURING SELECTIVE <br />DEMOLITION. THE PUBLIC, INCLUDING CHILDREN, MAY OCCUPY ADJACENT AREAS. <br />JJ. EXISTING CONDITIONS: NO RESPONSIBILITY FOR BUILDINGS AND STRUCTURES TO BE <br />DEMOLISHED WILL BE ASSUMED BY THE OWNER. <br />KK. STRUCTURE DEMOLITION: <br />1. APPLICATION: SALVAGE OF DESIGNATED ITEMS. <br />2. APPLICATION: PROTECTION OF SITE WORK AND ADJACENT STRUCTURES. <br />3. APPLICATION: DISCONNECTION, CAPPING, AND REMOVAL OF UTILITIES - IF/AS <br />REQUIRED <br />4. APPLICATION: POLLUTION CONTROL DURING BUILDING DEMOLITION, INCLUDING <br />NOISE CONTROL. <br />5. APPLICATION: REMOVAL AND LEGAL DISPOSAL OF MATERIALS. <br />6. PROTECTION: DESIGNATED SITE IMPROVEMENTS AND ADJACENT CONSTRUCTION. <br />7. SALVAGE: DESIGNATED ITEMS. <br />8. HAZARDOUS MATERIALS: NOT PRESENT. <br />1.0 GENERAL CONDITIONS LL. DEMOLITION OPERATIONS: DO NOT DAMAGE BUILDING ELEMENTS AND IMPROVEMENTS <br />INDICATED TO REMAIN. ITEMS OF SALVAGE VALUE, NOT INCLUDED ON SCHEDULE OF <br />SALVAGE ITEMS TO BE RETURNED TO OWNER, SHALL BE REMOVED FROM STRUCTURE. <br />STORAGE OR SALE OF ITEMS AT PROJECT SITE IS PROHIBITED. <br />MM.UTILITIES: LOCATE, IDENTIFY, DISCONNECT, AND SEAL OR CAP OFF UTILITIES IN BUILDINGS TO <br />BE DEMOLISHED. <br />NN. SHORING AND BRACING: PROVIDE AND MAINTAIN INTERIOR AND EXTERIOR SHORING AND <br />BRACING. <br />OO. OCCUPIED SPACES: DO NOT CLOSE OR OBSTRUCT STREETS, WALKS, DRIVES OR OTHER <br />OCCUPIED OR USED SPACES OR FACILITIES WITHOUT THE WRITTEN PERMISSION OF THE <br />OWNER AND THE AUTHORITIES HAVING JURISDICTION. DO NOT INTERRUPT UTILITIES SERVING <br />OCCUPIED OR USED FACILITIES WITHOUT THE WRITTEN PERMISSION OF THE OWNER AND <br />AUTHORITIES HAVING JURISDICTION. IF NECESSARY, PROVIDE TEMPORARY UTILITIES. <br />PP. OPERATIONS: CEASE OPERATIONS IF PUBLIC SAFETY OR REMAINING STRUCTURES ARE <br />ENDANGERED. PERFORM TEMPORARY CORRECTIVE MEASURES UNTIL OPERATIONS CAN BE <br />CONTINUED PROPERLY. <br />QQ. SECURITY: PROVIDE ADEQUATE PROTECTION AGAINST ACCIDENTAL TRESPASSING. SECURE <br />PROJECT AFTER WORK HOURS. <br />RR. RESTORATION: RESTORE FINISHES OF PATCHED AREAS. <br />5.0 METALS <br />7.2 BLANKET/BATT INSULATION <br />1. MANUFACTURER: AS SELECTED BY CONTRACTOR <br />2. APPLICATION: THERMAL INSULATION IN STUDS IN EXTERIOR WALLS. <br />3. APPLICATION: THERMAL INSULATION AT UNDERSIDE OF ROOFS, OVER HEATED <br />SPACES AND SOFFITS. <br />4. TYPE: FOIL-FACED MINERAL FIBER. <br />a. STANDARD: ASTM C 665, TYPE III (FOIL-SCRIM-KRAFT VAPOR-RETARDER <br />MEMBRANE). <br />b. ACCESSORIES: FASTENERS AND TAPES. <br />7.0 THERMAL AND MOISTURE PROTECTION <br />A. PRODUCT DATA: SUBMIT MANUFACTURER'S PRODUCT DATA AND INSTALLATION <br />INSTRUCTIONS FOR EACH MATERIAL AND PRODUCT USED. <br />B. SUBMIT FOR APPROVAL TEST REPORTS. <br />C. COMPLY WITH GOVERNING CODES AND REGULATIONS. PROVIDE PRODUCTS OF ACCEPTABLE <br />MANUFACTURERS, WHICH HAVE BEEN IN SATISFACTORY USE IN SIMILAR SERVICE FOR THREE <br />YEARS. USE EXPERIENCED INSTALLERS. DELIVER, HANDLE, AND STORE MATERIALS IN <br />ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. <br />A SUMMARY: PROVIDE JOINT SEALERS AND FILLERS. <br />B PRODUCT DATA: SUBMIT MANUFACTURER'S PRODUCT DATA AND INSTALLATION <br />INSTRUCTIONS FOR EACH MATERIAL AND PRODUCT USED. <br />C. SAMPLES: SUBMIT TWO REPRESENTATIVE SAMPLES OF EACH MATERIAL SPECIFIED <br />INDICATING VISUAL CHARACTERISTICS AND FINISH. INCLUDE RANGE SAMPLES IF <br />VARIATION OF FINISH IS ANTICIPATED. <br />1. INCLUDE MANUFACTURERS FULL RANGE OF COLOR AND FINISH OPTIONS IF <br />ADDITIONAL SELECTION IS REQUIRED. <br />D QUALITY ASSURANCE: COMPLY WITH GOVERNING CODES AND REGULATIONS. PROVIDE <br />PRODUCTS OF ACCEPTABLE MANUFACTURERS, WHICH HAVE BEEN IN SATISFACTORY USE IN <br />SIMILAR SERVICE FOR THREE YEARS. USE EXPERIENCED INSTALLERS. DELIVER, HANDLE, AND <br />STORE MATERIALS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. <br />E.MATERIALS <br />A. EXTERIOR JOINTS IN VERTICAL SURFACES: TWO COMPONENT SILICONE ,TWO- <br />COMPONENT URETHANE SEALANT. <br />C. EXTERIOR JOINTS IN VERTICAL SURFACES, PREFORMED COMPRESSION SEALS: <br />PREFORMED PRECOMPRESSED FOAM SEALANT. <br />D. EXTERIOR JOINTS IN HORIZONTAL SURFACES, URETHANE: <br />SELF-LEVELING URETHANE SEALANT, ASTM C 920. <br />F. EXTERIOR PAVING JOINT FILLERS, BITUMINOUS: <br />BITUMINOUS FIBER. <br />G. INTERIOR JOINTS, LIMITED MOVEMENT, ACRYLIC: <br />ACRYLIC-EMULSION, ASTM C 834. <br />H. INTERIOR JOINTS, SANITARY SILICONE: <br />ONE-PART MILDEW-RESISTANT SILICONE SEALANT, ASTM C 920. <br />F INSTALLATION <br />A. EXAMINE SUBSTRATE; REPORT UNSATISFACTORY CONDITIONS IN WRITING. <br />BEGINNING WORK MEANS ACCEPTANCE OF SUBSTRATES. <br />B. PROVIDE SEALANTS IN COLORS AS SELECTED FROM MANUFACTURER'S STANDARDS. <br />C. INSTALL MATERIALS AND SYSTEMS IN ACCORDANCE WITH MANUFACTURER'S <br />INSTRUCTIONS AND APPROVED SUBMITTALS. INSTALL MATERIALS AND SYSTEMS IN <br />PROPER RELATION WITH ADJACENT CONSTRUCTION AND WITH UNIFORM <br />APPEARANCE. COORDINATE WITH WORK OF OTHER SECTIONS. CLEAN AND <br />PRIME JOINTS, AND INSTALL BOND BREAKERS, BACKER RODS AND SEALANT AS <br />RECOMMENDED BY MANUFACTURERS. <br />D. DEPTH SHALL EQUAL WIDTH UP TO 1/2 INCH WIDE; DEPTH SHALL EQUAL 1/2 <br />WIDTH FOR JOINTS OVER 1/2 INCH WIDE. <br />E. CURE AND PROTECT SEALANTS AS DIRECTED BY MANUFACTURERS. REPLACE OR <br />RESTORE DAMAGED SEALANTS. CLEAN ADJACENT SURFACES TO REMOVE <br />SPILLAGE. <br />7.1 JOINT SEALANT <br />A. PRODUCT DATA: SUBMIT MANUFACTURER'S PRODUCT DATA AND INSTALLATION <br />INSTRUCTIONS FOR EACH MATERIAL AND PRODUCT USED. <br />B. SHOP DRAWINGS: SUBMIT SHOP DRAWINGS INDICATING MATERIAL CHARACTERISTICS, DETAILS <br />OF CONSTRUCTION, CONNECTIONS, AND RELATIONSHIP WITH ADJACENT CONSTRUCTION. <br />C. SAMPLES: SUBMIT TWO REPRESENTATIVE SAMPLES OF EACH MATERIAL SPECIFIED INDICATING <br />VISUAL CHARACTERISTICS AND FINISH. INCLUDE RANGE SAMPLES IF VARIATION OF FINISH IS <br />ANTICIPATED. <br />D. COMPLY WITH GOVERNING CODES AND REGULATIONS. PROVIDE PRODUCTS OF ACCEPTABLE <br />MANUFACTURERS, WHICH HAVE BEEN IN SATISFACTORY USE IN SIMILAR SERVICE FOR THREE <br />YEARS. USE EXPERIENCED INSTALLERS. DELIVER, HANDLE, AND STORE MATERIALS IN <br />ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. <br />E. FLASHING AND SHEET METAL: <br />1. MANUFACTURERS: AS SELECTED BY CONTRACTOR <br />2. APPLICATION: METAL COUNTERFLASHING AND BASE FLASHING. <br />3. APPLICATION: EXTERIOR WALL FLASHING. <br />4. APPLICATION: EXTERIOR ROOF-MOUNTED MECHANICAL & PLUMBING ELEMENTS <br />5. APPLICATION: EXPOSED METAL TRIM AND FASCIA UNITS. <br />6. FLEXIBLE SHEET MEMBRANE FLASHING: NONREINFORCED FLEXIBLE BLACK ELASTIC <br />SHEET, 50 TO 65 MILS THICK, SYNTHETIC RUBBER- VERIFY IN FIELD WITH EXISTING <br /> ROOFING SYSTEM'S MANUFACTURER AND WARRANTY <br />7. METAL WALL PANEL TRIM & FLASHING PER MANUFACTURER'S STANDARDS & SMACNA <br />7.3 FLASHING AND SHEET METAL <br />8.1 DOOR HARDWARE <br />A. SUBMITTALS: SUBMIT IN ACCORDANCE WITH CONDITIONS OF THE CONTRACT AND DIVISION 01 <br />B. SHOP DRAWINGS: SCHEDULE HARDWARE IN VERTICAL FORMAT USING THE DHI PUBLICATION <br />SEQUENCE AND FORMATTING FOR THE HARDWARE SCHEDULE. INCLUDE ABBREVIATIONS AND <br />SYMBOLS PAGE TO INCLUDE MANUFACTURERS’ ABBREVIATIONS, FINISH CODE DESCRIPTIONS, AND <br />FASTENER ABBREVIATIONS INCLUDING DESCRIPTIONS ACCORDING TO THE DHI PUBLICATION <br />ABBREVIATIONS AND SYMBOLS. DETAIL HEADINGS REFERENCING THE ARCHITECT’S HEADING, <br />OPENING NUMBER, LOCATIONS, FIRE RATING, HANDING, DEGREE OF OPENING, AND <br />DESCRIPTION OF THE OPENING ELEMENTS. INCLUDE VOLTAGE, AMPERAGE, AND OPERATIONAL <br />DESCRIPTIONS FOR OPENINGS THAT HAVE ELECTRIFIED HARDWARE.COORDINATE FINAL DOOR <br />HARDWARE SCHEDULE WITH DOORS, FRAMES, AND RELATED WORK LISTING PROPER SIZING OF <br />HARDWARE, ADDRESSING DOOR THICKNESS, HANDING, FUNCTION, MOUNTING ACCESSORIES, <br />AND FINISH OF HARDWARE. LIST RELATED DOOR DEVICES SPECIFIED IN OTHER SECTIONS FOR <br />EACH OPENING. ARCHITECTURAL HARDWARE CONSULTANT (AHC), AS CERTIFIED BY DHI, WHO WILL <br />AFFIX SEAL ATTESTING TO COMPLETENESS AND CORRECTNESS, INCLUDING THE REVIEW OF THE <br />HARDWARE SCHEDULE PRIOR TO SUBMITTAL. <br />C. PRODUCT DATA: FURNISH MANUFACTURERS’ CATALOG SHEETS ON DESIGN, GRADE, AND <br />FUNCTION OF ITEMS LISTED IN HARDWARE SCHEDULE. SUBMIT ONLY RELEVANT INFORMATION <br />AND CIRCLE OR HIGHLIGHT THE TECHNICAL INFORMATION INCLUDING: MODEL NUMBERS, SIZING <br />INFORMATION, VOLTAGE AND AMPERAGE REQUIREMENTS, OPTIONS AND ACCESSORIES <br />REQUIRED, MEANS OF FASTENING, LISTINGS OF FIRE-RATED APPLICATIONS, AND FINISHES. <br />E. TEMPLATES:WITHIN FOURTEEN DAYS OF RECEIVING APPROVED DOOR HARDWARE SUBMITTALS <br />SUBMIT COMPLETE LIST OF TEMPLATES FOR EACH HARDWARE ITEM TO THE OPENING <br />MANUFACTURERS AND THE INSTALLERS. INCLUDE DETAILED LISTS OF THE HARDWARE LOCATION <br />REQUIREMENTS FOR MORTISED AND SURFACE APPLIED HARDWARE. <br />F. CLOSEOUT SUBMITTALS: INCLUDE THE FOLLOWING INFORMATION AS WELL AS HIGHLIGHT AND <br />FLAG FIRE RATED OPENINGS FOR ANNUAL INSPECTIONS: <br />COVER PAGE WITH REQUIRED INFORMATION: <br />A.PROJECT NAME <br />B.HARDWARE SUPPLIER’S NAME AND CONTACT INFORMATION. <br />C. DATE OF SUBSTANTIAL COMPLETION. <br />2.FINAL RECORD HARDWARE SCHEDULE. <br />3.PRODUCT DATA. <br />4.KEYING SCHEDULE. <br />5.OPERATING AND MAINTENANCE MANUAL. <br />6.WARRANTY INFORMATION. <br />G. HARDWARE SUPPLIER SHALL EMPLOY AN ARCHITECTURAL HARDWARE CONSULTANT (AHC) AS <br />CERTIFIED BY DHI AND A MEMBER OF THE SEAL PROGRAM WHO WILL BE AVAILABLE AT REASONABLE <br />TIMES DURING COURSE OF WORK FOR PROJECT HARDWARE CONSULTATION. <br />H.WHERE OPENINGS ARE REQUIRED TO BE ACCESSIBLE DOOR HARDWARE SHALL CONFORM TO <br />ICC/ANSI A117.1. <br />I. DOOR HARDWARE CERTIFIED TO ANSI/BHMA STANDARDS AS NOTED, MANUFACTURER MUST <br />PARTICIPATE AND BE LISTED IN BHMA CERTIFIED PRODUCTS DIRECTORY. <br />J. INSTALLER QUALIFICATIONS: SPECIALIZED IN PERFORMING INSTALLATION OF THIS SECTION AND <br />HAVE FIVE YEARS MINIMUM DOCUMENTED EXPERIENCE. <br />K. DELIVERY, STORAGE, AND HANDLING: PACK EACH ITEM COMPLETE WITH NECESSARY PARTS AND <br />FASTENERS IN MANUFACTURER’S ORIGINAL PACKAGING. MARK HARDWARE THAT IS NOT BULK <br />PACKED WITH ARCHITECT’S OPENING NUMBER, HARDWARE SET NUMBER, AND ITEM NUMBER FOR <br />EACH TYPE OF HARDWARE. INCLUDE KEYSET SYMBOLS AND CORRESPONDING HARDWARE <br />COMPONENT FOR KEYED PRODUCTS. MARK HARDWARE THAT IS BULK PACKED WITH <br />MANUFACTURERS’ PART NUMBER AND REFERENCE ALL HARDWARE SETS ASSOCIATED. DELIVER <br />HARDWARE TO THE JOB SITE ACCORDING TO THE PHASING AGREED UPON IN THE PRE- <br />INSTALLATION MEETING. INVENTORY THE DELIVERY WITH THE SUPPLIER’S ASSISTANCE. <br />IMMEDIATELY NOTE SHORTAGES AND DAMAGES ON THE SHIPPING RECEIPTS AND BILL OF LADINGS. <br />COORDINATE REPLACEMENT OR REPAIR WITH THE SUPPLIER. DELIVER PERMANENT KEYS, CORES, <br />AND RELATED ACCESSORIES DIRECTLY TO OWNER VIA REGISTERED MAIL OR OVERNIGHT PACKAGE <br />SERVICE. ESTABLISH THE INSTRUCTIONS FOR DELIVERY TO OWNER AT “KEYING CONFERENCE.” <br />PROVIDE A CLEAN, DRY, AND SECURE ROOM FOR HARDWARE DELIVERED. SHELVE HARDWARE OFF <br />THE FLOOR AND WITH LARGER ITEMS OF HARDWARE STORED ON PALLETS. ARRANGE LOCKSETS <br />AND KEYED CYLINDERS BY OPENING NUMBER. ORGANIZE THE BALANCE OF HARDWARE BY BRAND, <br />MODEL OF HARDWARE, AND HARDWARE SET NUMBER. LEAVE THE DOOR MARKINGS OF THE <br />HARDWARE VISIBLE FOR INSTALLERS. <br />L. WARRANTY: <br />1.TEN YEARS FOR MANUAL DOOR CLOSERS. <br />2.FIVE YEARS FOR LOCKS. <br />3.FIVE YEARS FOR EXIT DEVICES. <br />M. MAINTENANCE: MAINTENANCE TOOL AND INSTRUCTIONS: FURNISH A COMPLETE SET OF <br />SPECIALIZED TOOLS AND MAINTENANCE INSTRUCTIONS FOR OWNER’S CONTINUED ADJUSTMENT, <br />MAINTENANCE, REMOVAL, AND REPLACEMENT OF DOOR HARDWARE. <br />N. MATERIALS: PRODUCE HARDWARE UNITS OF BASIC METAL AND FORMING METHOD USING <br />MANUFACTURER'S STANDARD METAL ALLOY, COMPOSITION, TEMPER, AND HARDNESS, BUT IN NO <br />CASE OF LESSER (COMMERCIALLY RECOGNIZED) QUALITY THAN SPECIFIED WITHIN THIS <br />SPECIFICATION SECTION FOR APPLICABLE HARDWARE UNITS FOR FINISH DESIGNATIONS <br />INDICATED. <br />O: FASTENERS: FURNISH SCREWS FOR INSTALLATION WITH EACH HARDWARE ITEM. USE ONLY <br />FASTENERS THAT ARE FURNISHED BY THE HARDWARE MANUFACTURER TO MEET THE <br />MANUFACTURER’S TEMPLATING REQUIREMENTS, WARRANTY AND NFPA 80 REQUIREMENTS.PROVIDE <br />PHILLIPS FLAT-HEAD SCREWS EXCEPT AS OTHERWISE INDICATED.FINISH EXPOSED SCREWS TO MATCH <br />HARDWARE FINISH OR, IF EXPOSED IN SURFACES OF OTHER WORK, TO MATCH FINISH OF THIS <br />OTHER WORK AS CLOSELY AS POSSIBLE INCLUDING "PREPARED FOR PAINT" SURFACES TO RECEIVE <br />PAINTED FINISH. USE MACHINE SCREWS WITH LEAD EXPANSION SHIELDS AT HARDWARE <br />MOUNTING TO MASONRY WALLS AND FLOORS.WOOD SCREW WITH PLASTIC ANCHORS AT <br />DRYWALL APPLICATIONS WITHOUT REINFORCEMENT AND WOOD SCREWS AT APPLICATIONS WITH <br />REINFORCEMENTS.PROVIDE CONCEALED FASTENERS FOR HARDWARE UNITS THAT ARE EXPOSED <br />WHEN DOOR IS CLOSED EXCEPT TO THE EXTENT NO STANDARD UNITS OF TYPE SPECIFIED ARE <br />AVAILABLE WITH CONCEALED FASTENERS. DO NOT USE THRU-BOLTS FOR INSTALLATION WHERE <br />BOLT HEAD OR NUT ON OPPOSITE FACE IS EXPOSED IN OTHER WORK UNLESS THEIR USE IS THE <br />ONLY MEANS OF REINFORCING THE WORK ADEQUATELY TO FASTEN THE HARDWARE <br />SECURELY.WHERE THRU-BOLTS ARE USED AS A MEANS OF REINFORCING THE WORK, PROVIDE <br />SLEEVES FOR EACH THRU-BOLT OR USE SEX NUT FASTENERS. AT EXTERIOR OPENINGS FURNISH <br />STAINLESS-STEEL FASTENERS FOR EXPOSED FASTENERS, FOR EXAMPLE THRESHOLDS AND SCREW- <br />APPLIED WEATHERSTRIPPING. <br />X. PROTECTIVE TRIM: PROTECTIVE TRIM OF ONE MANUFACTURER AS LISTED FOR CONTINUITY <br />OF DESIGN AND CONSIDERATION OF WARRANTY. <br />A.SIZE OF PROTECTION PLATE: SINGLE DOORS, SIZE TWO INCHES LESS DOOR WIDTH (LDW) <br />ON PUSH SIDE OF DOOR, AND ONE INCH LESS DOOR WIDTH ON PULL SIDE OF DOOR. FOR <br />PAIRS OF DOORS, SIZE ONE INCH LESS DOOR WIDTH (LDW) ON PUSH SIDE OF DOOR, AND 1/2 <br />INCH ON PULL SIDE OF DOOR. ADJUST SIZES TO ACCOMMODATE ACCOMPANYING <br />HARDWARE, SUCH AS, EDGE GUARDS, ASTRAGALS, AND OTHERS. <br />1. KICK PLATES 10” HIGH OR SIZED TO DOOR BOTTOM RAIL HEIGHT. <br />2. MOP PLATES 4” HIGH. <br />3. ARMOR PLATES 36” HIGH. <br />B.PRODUCTS TO BE CERTIFIED AND LISTED BY THE FOLLOWING: <br />1. ARCHITECTURAL DOOR TRIM: ANSI/BHMA A156.6. <br />2. UL. <br />C. MATERIAL AND DESIGN: <br />1. 0.050” GAGE STAINLESS STEEL. <br />2. CORNERS SQUARE, POLISHING LINES, OR DOMINANT DIRECTION OF SURFACE PATTERN <br />SO THEY RUN ACROSS DOOR WIDTH OF PLATE. <br />3. BEVEL TOP, BOTTOM, AND SIDES UNIFORMLY LEAVING NO SHARP EDGES. <br />4. COUNTERSINK HOLES FOR SCREWS. SPACE SCREW HOLES SO THEY ARE NO MORE <br />THAN EIGHT INCHES CTC, ALONG A CENTERLINE NOT OVER 1/2” IN FROM EDGE <br />AROUND PLATE. END SCREWS MAXIMUM OF 0.53” FROM CORNERS. <br />D.UL LABEL STAMP REQUIRED ON PROTECTION PLATES WHEN TOP OF PLATE IS MORE THAN 16 <br />INCHES ABOVE BOTTOM OF DOOR ON FIRE RATED OPENINGS. VERIFY DOOR <br />MANUFACTURER’S UL LISTING FOR MAXIMUM HEIGHT AND WIDTH OF PROTECTION PLATE TO <br />BE USED. <br />Y. STOPS AND HOLDERS: STOPS AND HOLDERS OF ONE MANUFACTURER AS LISTED FOR <br />CONTINUITY OF DESIGN AND CONSIDERATION OF WARRANTY. <br />A.WALL STOPS: PROVIDE DOOR STOPS WHEREVER NECESSARY TO PREVENT DOOR OR <br />HARDWARE FROM STRIKING AN ADJACENT PARTITION OR OBSTRUCTION. PROVIDE WALL <br />STOPS WHEN POSSIBLE. DOOR STOPS AND HOLDERS MOUNTED IN CONCRETE FLOOR OR <br />MASONRY WALLS HAVE STAINLESS STEEL MACHINE SCREWS AND LEAD EXPANSION SHIELDS. <br />B.PRODUCTS TO BE CERTIFIED AND LISTED BY THE FOLLOWING: <br />1. AUXILIARY HARDWARE: ANSI/BHMA A156.16. <br />C. OVERHEAD STOPS AND HOLDERS: PROVIDE OVERHEAD STOPS AND HOLDERS FOR DOORS <br />THAT OPEN AGAINST EQUIPMENT, CASEWORK SIDELIGHTS AND OTHER OBJECTS THAT WOULD <br />MAKE WALL STOPS/HOLDERS AND FLOOR STOPS/HOLDERS INAPPROPRIATE. PROVIDE SEX BOLT <br />ATTACHMENTS FOR MINERAL CORE WOOD DOOR APPLICATIONS. <br />D.PRODUCTS TO BE CERTIFIED AND LISTED BY THE FOLLOWING: <br />1. OVERHEAD STOPS AND HOLDERS: ANSI/BHMA A156.8 GRADE 1. <br />Z. THRESHOLDS: THRESHOLDS OF ONE MANUFACTURER AS LISTED FOR CONTINUITY OF DESIGN <br />AND CONSIDERATION OF WARRANTY. <br />A.SET THRESHOLDS FOR EXTERIOR AND ACOUSTICAL OPENINGS IN FULL BED OF SEALANT <br />WITH LEAD EXPANSION SHIELDS AND STAINLESS-STEEL MACHINE SCREWS COMPLYING WITH <br />REQUIREMENTS SPECIFIED IN DIVISION 07 SECTION “JOINT SEALANTS: NOTCHED IN FIELD TO <br />FIT FRAME BY HARDWARE INSTALLER. REFER TO DRAWINGS FOR SPECIAL DETAILS. <br />B.STANDARDS: MANUFACTURER TO BE CERTIFIED BY THE FOLLOWING: <br />1. THRESHOLDS: ANSI/BHMA A156.21. <br />2. AMERICAN WITH DISABILITIES ACT ACCESSIBILITY GUIDELINES (ADAAG). <br />AA. DOOR GASKETING AND WEATHERSTRIP: DOOR GASKETING AND WEATHERSTRIP OF ONE <br />MANUFACTURER AS LISTED FOR CONTINUITY OF DESIGN AND CONSIDERATION OF WARRANTY. <br />A.PROVIDE CONTINUOUS WEATHERSTRIP GASKETING ON EXTERIOR DOORS AND PROVIDE <br />SMOKE, LIGHT, OR SOUND GASKETING WHERE INDICATED ON HARDWARE SCHEDULE. <br />PROVIDE NONCORROSIVE FASTENERS FOR EXTERIOR APPLICATIONS. <br />1. PERIMETER GASKETING: APPLY TO HEAD AND JAMB, FORMING SEAL BETWEEN DOOR <br />AND FRAME. <br />2. MEETING STILE GASKETING: FASTEN TO MEETING STILES, FORMING SEAL WHEN DOORS <br />ARE IN CLOSED POSITION. <br />3. DOOR BOTTOMS: APPLY TO BOTTOM OF DOOR, FORMING SEAL WITH THRESHOLD OR <br />FLOOR WHEN DOOR IS IN CLOSED POSITION. <br />4. SOUND GASKETING: CUTTING OR NOTCHING FOR STOP MOUNTED HARDWARE NOT <br />PERMITTED. <br />5. DRIP GUARD: APPLY TO EXTERIOR FACE OF FRAME HEADER. LIP LENGTH TO EXTEND 4” <br />BEYOND WIDTH OF DOOR. <br />B.PRODUCTS TO BE CERTIFIED AND LISTED BY THE FOLLOWING: <br />1. DOOR GASKETING AND EDGE SEAL SYSTEMS: ANSI/BHMA A156.22. <br />2. BHMA CERTIFIED FOR DOOR SWEEPS, AUTOMATIC DOOR BOTTOMS, AND ADHESIVE <br />APPLIED GASKETING. <br />C. REFER TO SECTION 08 1416 WOOD DOORS FOR CATEGORY A OR CATEGORY B. <br />COMPLY WITH UBC 7-2 AND UL10C POSITIVE PRESSURE WHERE FRAME APPLIED INTUMESCENT <br />SEALS ARE REQUIRED. <br />Q. FLUSH BOLTS: FLUSH BOLTS OF ONE MANUFACTURER AS LISTED FOR CONTINUITY OF DESIGN <br />AND CONSIDERATION OF WARRANTY. MANUFACTURER TO BE LISTED BY THE FOLLOWING: <br />AUXILIARY HARDWARE: ANSI/BHMI A156.16. LABELED OPENINGS: PROVIDE AUTOMATIC OR <br />CONSTANT LATCHING FLUSH BOLTS PER HARDWARE SCHEDULE FOR INACTIVE LEAF OF PAIRS OF <br />DOORS. PROVIDE DUST PROOF STRIKES FOR BOTTOM BOLT. NON-LABELED OPENINGS: <br />PROVIDE TWO FLUSH BOLTS FOR INACTIVE LEAF OF PAIRS OF DOORS PER HARDWARE SCHEDULE. <br />PROVIDE EXTENSION RODS SO THAT THE CENTER LINE OF THE TOP FLUSH BOLT IS NOT MORE <br />THAN 78” ABOVE THE FINISH FLOOR. PROVIDE DUST PROOF STRIKE FROM BOTTOM BOLT. <br />R. HEAVY DUTY CYLINDRICAL LOCKS AND LATCHES: LOCKS AND LATCHES OF ONE <br />MANUFACTURER AS LISTED FOR CONTINUITY OF DESIGN AND CONSIDERATION OF WARRANTY. <br />A.STANDARDS: PRODUCT TO BE CERTIFIED AND LISTED BY FOLLOWING: <br />1.ANSI/BHMA A156.2 SERIES 4000 CERTIFIED TO GRADE 1. <br />2.UL/CUL LABELED AND LISTED FOR FUNCTIONS UP TO 3 HOURS FOR SINGLE DOORS UP <br />TO 48” IN WIDTH AND UP TO 96” IN HEIGHT. <br />3.UL10C/UBC 7-2 POSITIVE PRESSURE RATED. <br />4.ICC/ANSI A1117.1 <br />B.LOCK AND LATCH FUNCTION NUMBERS AND DESCRIPTIONS OF MANUFACTURER’S SERIES <br />AS LISTED IN HARDWARE SETS. <br />V.MATERIAL AND DESIGN: <br />1.LOCK AND LATCH CHASSIS TO BE ZINC DICHROMATE FOR CORROSION RESISTANCE. <br />2.KEYED FUNCTIONS TO BE OF A FREEWHEELING DESIGN TO HELP RESIST AGAINST <br />VANDALISM. <br />3.NON-HANDED, FIELD REVERSIBLE. <br />4.THRU BOLT MOUNTING WITH NO EXPOSED SCREWS. <br />5.LEVERS, ZINC CAST AND PLATED TO MATCH FINISHED DESIGNATION IN HARDWARE <br />SETS. <br />6.ROSES MADE OF WROUGHT BRASS OR STAINLESS-STEEL MATERIAL. <br />D.LATCH AND STRIKE: <br />1.STAINLESS STEEL LATCH BOLT WITH MINIMUM OF 1/2” THROW AND DEADLOCKING <br />FOR KEYED AND EXTERIOR FUNCTIONS. PROVIDE 3/4” LATCH BOLT FOR PAIRS OF FIRE- <br />RATED DOORS WHERE REQUIRED BY DOOR MANUFACTURER. STANDARD BACKSET TO <br />BE 2-3/4” AND ADJUSTABLE FACEPLATE TO ACCOMMODATE A SQUARE EDGE DOOR OR <br />A STANDARD 1/8” BEVELED EDGE DOOR. <br />2.STRIKE IS TO FIT A STANDARD ANSI A115 PREP MEASURING 1-1/4” X 4-7/8” WITH <br />PROPER LIP LENGTH TO PROTECT SURROUNDING TRIM. <br />S. INTERCONNECTED LOCKS AND LATCH: LOCKS AND LATCHES OF ONE MANUFACTURER AS <br />LISTED FOR CONTINUITY OF DESIGN AND CONSIDERATION OF WARRANTY. <br />A.STANDARDS: PRODUCT TO BE CERTIFIED AND LISTED BY FOLLOWING: <br />1.ANSI/BHMA A156.12 SERIES 5000 CERTIFIED TO GRADE 2. <br />2.UL/CUL LABELED AND LISTED FOR FUNCTIONS UP TO 3 HOURS FOR SINGLE DOORS UP <br />TO 48” IN WIDTH AND UP TO 96” IN HEIGHT. <br />3.UL10C/UBC 7-2 POSITIVE PRESSURE RATED. <br />4.ICC/ANSI A117.1 <br />B.LOCK AND LATCH FUNCTION NUMBERS AND DESCRIPTIONS OF MANUFACTURER’S SERIES AS <br />LISTED IN HARDWARE SETS. <br />C. MATERIAL AND DESIGN: <br />1.LOCK AND LATCH CHASSIS TO BE ZINC DICHROMATE FOR CORROSION RESISTANCE. <br />2.KEYED FUNCTIONS TO BE OF A FREEWHEELING DESIGN TO HELP RESIST AGAINST <br />VANDALISM. <br />3.NON-HANDED, FIELD REVERSIBLE. <br />4.LEVERS, ZINC CAST AND PLATED TO MATCH FINISH DESIGNATION IN HARDWARE SETS. <br />5.ROSES, SOLID BRASS OR STAINLESS-STEEL MATERIAL AND HAVE A MINIMUM DIAMETER OF <br />2-1/2”. <br />T. EXIT DEVICES: EXIT DEVICES OF ONE MANUFACTURER AS LISTED FOR CONTINUITY OF DESIGN <br />AND CONSIDERATION OF WARRANTY. TOUCHPAD TYPE FINISH TO MATCH BALANCE OF DOOR <br />HARDWARE. <br />A.STANDARDS: MANUFACTURER TO BE CERTIFIED AND/OR LISTED BY THE FOLLOWING: <br />1.BHMA CERTIFIED ANSI A156.3 GRADE 1. <br />2.UL/CUL LISTED FOR UP TO 3 HOURS FOR “A” LABELED DOORS. <br />3.UL10C/UBC 7-2 POSITIVE PRESSURE RATED. <br />4.UL10B NEUTRAL PRESSURE RATED. <br />5.UL 305 LISTED FOR PANIC HARDWARE. <br />B.MATERIAL AND DESIGN: <br />1.PROVIDE EXIT DEVICES WITH ACTUATORS THAT EXTEND A MINIMUM OF ONE-HALF OF <br />DOOR WIDTH. <br />2.WHERE TRIM IS INDICATED IN HARDWARE SETS PROVIDE THE LEVER DESIGN TO MATCH <br />DESIGN OF LOCK LEVERS. <br />3.EXIT DEVICE TO MOUNT FLUSH WITH DOOR. <br />8.0 DOORS AND WINDOWS 4.LATCH BOLTS: <br />A.RIM DEVICE – 3/4” THROW, PULLMAN TYPE WITH AUTOMATIC DEAD-LATCHING, <br />STAINLESS STEEL <br />B.SURFACE VERTICAL ROD DEVICE – TOP 1/2” THROW, PULLMAN TYPE WITH <br />AUTOMATIC DEAD-LATCHING, STAINLESS STEEL. BOTTOM 1/2” THROW, PULLMAN <br />TYPE, HELD RETRACTED DURING DOOR SWING, STAINLESS STEEL. <br />5.FASTENERS: WOOD SCREWS, MACHINE SCREWS, AND THRU BOLTS. <br />C. LOCK AND LATCH FUNCTIONS: FUNCTION NUMBERS AND DESCRIPTIONS OF <br />MANUFACTURER’S SERIES AND LEVER STYLES INDICATED IN DOOR HARDWARE SETS. <br />U. CYLINDERS AND KEYING:CYLINDERS OF ONE MANUFACTURER AS LISTED FOR CONTINUITY OF <br />DESIGN AND CONSIDERATION OF WARRANTY. <br />A.PRODUCTS TO BE CERTIFIED AND LISTED BY THE FOLLOWING: <br />1.AUXILIARY LOCKS: ANSI/BHMA A156.5 <br />B.CYLINDERS: <br />1.PROVIDE CYLINDERS MATCHED TO THE TYPES REQUIRED FOR HARDWARE THAT HAS A <br />LOCKING FUNCTION AND FOR KEYED ELECTRONIC FUNCTIONS. FURNISH WITH <br />APPROPRIATE COLLARS, CAMS, AND TAILPIECES TO FIT AND OPERATE ASSOCIATED <br />HARDWARE. STACKING COLLARS IS NOT ACCEPTABLE, A SINGLE COLLAR OF PROPER SIZE <br />IS REQUIRED. <br />2.MANUFACTURER’S SIX-PIN/SEVEN-PIN SMALL FORMAT INTERCHANGEABLE CORE (SFIC). <br />3.MATCH EXISTING FACILITY STANDARD. <br />C. KEYING: <br />1.KEY INTO OWNER’S EXISTING KEY SYSTEM. <br />2.PROVIDE A BITTING LIST TO OWNER OF COMBINATIONS AS ESTABLISHED AND EXPAND <br />TO TWENTY-FIVE PERCENT FOR FUTURE USE OR AS DIRECTED BY OWNER. <br />A.INCLUDE ALL THE KEYSETS AND BITTINGS OF THE ORIGINAL KEY SYSTEM CREATING <br />ONE CLEAN VERSION OF THE ENTIRE KEY SYSTEM. <br />3.KEYS TO BE SHIPPED DIRECTLY TO THE OWNER’S REPRESENTATIVE AS ESTABLISHED <br />DURING THE KEYING CONFERENCE. <br />A.PACKAGE THE KEYS IN INDIVIDUAL ENVELOPES, GROUPED BY KEYSET SYMBOL, AND <br />LABEL ENVELOPES WITH PROJECT NAME, FACTORY REGISTRY NUMBER, AND KEYSET <br />SYMBOL. <br />4.STAMP LARGE BOW KEY BLANKS WITH VISUAL KEY CONTROL (KEYSET SYMBOL) AND “DO <br />NOT DUPLICATE”. <br />5.PROVIDE INTERCHANGEABLE CORES WITH CONSTRUCTION CORES AS REQUIRED PER <br />THE KEYING MEETING. <br />V. PUSH/PULL PLATES AND BARS: PUSH/PULL PLATES AND BARS OF ONE MANUFACTURER AS <br />LISTED FOR CONTINUITY OF DESIGN AND CONSIDERATION OF WARRANTY. <br />A.STANDARDS: MANUFACTURER TO BE CERTIFIED BY THE FOLLOWING: <br />1.ARCHITECTURAL DOOR TRIM: ANSI/BHMA A156.6. <br />2.AMERICANS WITH DISABILITIES ACT ACCESSIBILITY GUIDELINES (ADAAG). <br />B.PUSH PLATES: .050” THICK, SQUARE CORNER AND BEVELED EDGES WITH COUNTERSUNK <br />SCREW HOLES. WIDTH AND HEIGHT AS STATED IN HARDWARE SETS. <br />C. ACCEPTABLE MANUFACTURERS: <br />D.PULL PLATES: 1” DIAMETER PULL, WITH CLEARANCE OF 2-1/2” FROM FACE OF DOOR. <br />E. PUSH/PULL BAR SETS: 1” ROUND BAR STOCK WITH 2-1/2” CLEARANCES FROM FACE OF <br />DOOR. CENTER TO CENTER SIZE SHOULD BE DOOR WIDTH LESS 1 STILE WIDTH. <br />F. OFFSET VERTICAL DOOR PULL: 1-1/4” ROUND BAR STOCK WITH 2-1/2” CLEARANCES FROM <br />FACE OF DOOR. <br />W. CLOSERS: CLOSERS OF ONE MANUFACTURER AS LISTED FOR CONTINUITY OF DESIGN AND <br />CONSIDERATION OF WARRANTY, UNLESS OTHERWISE INDICATED ON HARDWARE SCHEDULE, <br />COMPLY WITH MANUFACTURER’S RECOMMENDATIONS FOR SIZE OF CLOSER, DEPENDING ON <br />WIDTH OF DOOR, FREQUENCY OF USE, ATMOSPHERIC PRESSURE, ADAAG REQUIREMENT, AND FIRE <br />RATING. <br />A.STANDARDS: MANUFACTURER TO BE CERTIFIED AND OR LISTED BY THE FOLLOWING: <br />1.BHMA CERTIFIED ANSI A156.4 GRADE 1. <br />2.ADA COMPLAINT ANSI A117.1. <br />3.UL/CUL LISTED UP TO 3 HOURS. <br />4.UL10C POSITIVE PRESSURE RATED. <br />5.UL10B NEUTRAL PRESSURE RATED. <br />B.MATERIAL AND DESIGN: <br />1.PROVIDE CAST IRON NON-HANDED BODIES WITH FULL PLASTIC COVERS. <br />2.CLOSERS WILL HAVE SEPARATED STAKED ADJUSTABLE VALVE SCREWS FOR LATCH SPEED, <br />SWEEP SPEED, AND BACKCHECK. <br />3.PROVIDE TRI-PACK ARMS AND BRACKETS FOR REGULAR ARM, TOP JAMB, AND PARALLEL <br />ARM MOUNTING. <br />4.ONE-PIECE SEAMLESS STEEL SPRING TUBE SEALED IN HYDRAULIC FLUID. <br />5.DOUBLE HEAT-TREATED STEEL TEMPERED SPRINGS. <br />6.PRECISION-MACHINED HEAT-TREATED STEEL PISTON. <br />7.TRIPLE HEAT-TREATED STEEL SPINDLE. <br />8.FULL RACK AND PINION OPERATION. <br />C. MOUNTING: <br />1.OUT-SWING DOORS USE SURFACE PARALLEL ARM MOUNT CLOSERS EXCEPT WHERE <br />NOTED ON HARDWARE SCHEDULE. <br />2.IN-SWING DOORS USE SURFACE REGULAR ARM MOUNT CLOSERS EXCEPT WHERE NOTED <br />ON HARDWARE SCHEDULE. <br />3.PROVIDE BRACKETS AND SHOE SUPPORTS FOR ALUMINUM DOORS AND FRAMES TO <br />MOUNT FIFTH SCREW. <br />4.FURNISH DROP PLATES WHERE TOP RAIL CONDITIONS ON DOOR DO NOT ALLOW FOR <br />MOUNTING OF CLOSER AND WHERE BACKSIDE OF CLOSER IS EXPOSED THROUGH GLASS. <br />D.SIZE CLOSERS IN COMPLIANCE WITH REQUIREMENTS FOR ACCESSIBILITY (ADAAG). COMPLY <br />WITH FOLLOWING MAXIMUM OPENING FORCE REQUIREMENTS. <br />1.INTERIOR HINGED OPENINGS: 5.0 LBS. <br />2.FIRE-RATED AND EXTERIOR OPENINGS USE MINIMUM OPENING FORCE ALLOWABLE BY <br />AUTHORITY HAVING JURISDICTION. <br />E. FASTENERS: PROVIDE SELF-REAMING, SELF-TAPPING WOOD AND MACHINE SCREWS, AND <br />SEX NUTS AND BOLTS FOR EACH CLOSER. <br />7.4 METAL WALL PANELS <br />I. COLD-FORMED METAL FRAMING: <br />1. MANUFACTURERS: REFER TO STRUCTURAL, AS SELECTED BY CONTRACTOR <br />2. APPLICATION: EXTERIOR NON-LOAD-BEARING STEEL-STUD WALLS. <br />3. APPLICATION: INTERIOR NON-LOAD-BEARING STEEL-STUD WALLS. <br />5. STRUCTURAL FRAMING: SEE STRUCTURAL PLANS <br />6. UNITS 16 GAUGE (.0598 INCH) AND HEAVIER: ASTM A 653, YIELD POINT 50,000. <br />7. UNITS 18 GAUGE (.0358 INCH): ASTM A 653, YIELD POINT 37,000 PSI. <br />8. UNITS 20 GAUGE (.0329 INCH): ASTM A 653, YIELD POINT 33,000 PSI. <br />10. FRAMING ACCESSORIES: <br />a. SUPPLEMENTARY FRAMING. <br />b. BRACING, BRIDGING, AND SOLID BLOCKING. <br />c. WEB STIFFENERS. <br />d. GUSSET PLATES. <br />e. DEFLECTION TRACK AND VERTICAL SIDE CLIPS. <br />f. STUD KICKERS AND GIRTS. <br />g. JOIST HANGERS AND END CLOSURES. <br />h. REINFORCEMENT PLATES. <br />i. ANCHORS, CLIPS, AND FASTENERS. <br />J. INSTALL MATERIALS AND SYSTEMS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS <br />AND APPROVED SUBMITTALS. INSTALL MATERIALS AND SYSTEMS IN PROPER RELATION WITH <br />ADJACENT CONSTRUCTION. COORDINATE WITH WORK OF OTHER SECTIONS. <br />K. COMPLY WITH REQUIREMENTS OF ASTM C 1007 FOR INSTALLATION OF STEEL STUDS AND <br />ACCESSORIES AND METAL LATH/STEEL FRAMING ASSOCIATION LIGHTWEIGHT STEEL FRAMING <br />SYSTEMS MANUAL. <br />L. RESTORE DAMAGED COMPONENTS. PROTECT WORK FROM DAMAGE. <br />A. PRODUCT DATA: SUBMIT MANUFACTURER'S PRODUCT DATA AND INSTALLATION <br />INSTRUCTIONS FOR EACH MATERIAL AND PRODUCT USED. <br />B. SHOP DRAWINGS: SUBMIT SHOP DRAWINGS INDICATING MATERIAL CHARACTERISTICS, DETAILS <br />OF CONSTRUCTION, CONNECTIONS, AND RELATIONSHIP WITH ADJACENT CONSTRUCTION. <br />1. SHOP DRAWINGS SHALL BE PREPARED AND STAMPED BY A QUALIFIED ENGINEER <br />LICENSED IN THE JURISDICTION OF THE PROJECT. <br />C. ENGINEERING CERTIFICATION: SUBMIT FOR APPROVAL ENGINEERING CERTIFICATION OF <br />DEFLECTION CRITERIA. <br />D. COMPLY WITH GOVERNING CODES AND REGULATIONS. PROVIDE PRODUCTS OF ACCEPTABLE <br />MANUFACTURERS, WHICH HAVE BEEN IN SATISFACTORY USE IN SIMILAR SERVICE FOR THREE <br />YEARS. USE EXPERIENCED INSTALLERS. DELIVER, HANDLE, AND STORE MATERIALS IN <br />ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. <br />E. STANDARDS: AISI, SPECIFICATION FOR DESIGN OF COLD-FORMED STEEL STRUCTURAL <br />MEMBERS. <br />F. DEFLECTION CRITERIA FOR EXTERIOR MASONRY VENEER: L/600. <br />G. FABRICATION TOLERANCES: 1/8 INCH IN 10 FEET. <br />H. ERECTION TOLERANCES: 1/16 INCH FROM TRUE POSITION. <br />5.1 COLD-FORMED METAL FRAMING <br />8. AUXILIARY MATERIALS: <br />a. SOLDER COMPATIBLE WITH METAL. <br />b. BITUMINOUS ISOLATION COATING. <br />c. MASTIC AND ELASTOMERIC SEALANTS. <br />d. EPOXY SEAM SEALER. <br />e. ROSIN-SIZED BUILDING PAPER SLIP SHEET. <br />f. POLYETHYLENE UNDERLAYMENT. <br />g. REGLETS AND METAL ACCESSORIES. <br />h. GUTTER AND CONDUCTOR HEAD GUARDS. <br />i. ASPHALTIC ROOFING CEMENT. <br />F. FOLLOW RECOMMENDATIONS OF SMACNA SHEET METAL MANUAL. ALLOW FOR EXPANSION. <br />ISOLATE DISSIMILAR MATERIALS. <br />G. INSTALL MATERIALS AND SYSTEMS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS <br />AND APPROVED SUBMITTALS. INSTALL MATERIALS AND SYSTEMS IN PROPER RELATION WITH <br />ADJACENT CONSTRUCTION AND WITH UNIFORM APPEARANCE. COORDINATE WITH WORK OF <br />OTHER SECTIONS. <br />H. RESTORE DAMAGED COMPONENTS AND FINISHES. CLEAN AND PROTECT WORK FROM <br />DAMAGE. <br />A. DEFINITIONS <br />A.WEATHER BARRIER: A COMBINATION OF MATERIALS AND ACCESSORIES THAT DO THE <br />FOLLOWING: <br />1.PREVENT THE ACCUMULATION OF WATER AS A WATER-RESISTIVE BARRIER. <br />2.MINIMIZE THE AIR LEAKAGE INTO OR OUT OF THE BUILDING ENVELOPE AS A <br />CONTINUOUS AIR BARRIER. <br />3.PROVIDE SUFFICIENT WATER VAPOR TRANSMISSION TO ENABLE DRYING AS A VAPOR- <br />PERMEABLE MEMBRANE. <br />B. ACTION SUBMITTALS <br />A.PRODUCT DATA: FOR EACH TYPE OF PRODUCT. <br />1.FOR WEATHER BARRIER, INCLUDE DATA ON AIR AND WATER-VAPOR PERMEANCE BASED <br />ON TESTING IN ACCORDANCE WITH REFERENCED STANDARDS. <br />C. INFORMATIONAL SUBMITTALS <br />A.EVALUATION REPORTS: FROM ICC-ES. <br />B.MANUFACTURER'S INSTRUCTIONS: FOR INSTALLATION OF EACH PRODUCT SPECIFIED. <br />C. QUALIFICATION DATA: FOR INSTALLER. <br />D.SAMPLE WARRANTY: FOR MANUFACTURER'S WARRANTY. <br />E. REPORTS: FIELD TEST AND INSPECTION REPORTS. <br />F. INSTALLER'S WEATHER BARRIER MANUFACTURER-TRAINING CERTIFICATE. <br />D. QUALITY ASSURANCE <br />A.INSTALLER QUALIFICATIONS: A QUALIFIED FIRM THAT IS CERTIFIED BY WEATHER BARRIER SYSTEM <br />MANUFACTURER TO INSTALL MANUFACTURER'S PRODUCT. <br />E. DELIVERY, STORAGE, AND HANDLING <br />A.DO NOT STORE NEAR HEAT SOURCE OR OPEN FLAME. <br />F. WARRANTY <br />1.WARRANTY PERIOD: 10 YEARS FROM DATE OF PURCHASE. <br />G. MANUFACTURERS <br />A.SOURCE LIMITATIONS: OBTAIN WEATHER BARRIER ASSEMBLY COMPONENTS, INCLUDING <br />WEATHER BARRIER FLASHING FROM SAME MANUFACTURER AS WEATHER BARRIER. <br />H. PERFORMANCE REQUIREMENTS <br />A.GENERAL PERFORMANCE: INSTALLED WEATHER BARRIER AND ACCESSORIES SHALL WITHSTAND <br />SPECIFIED WIND PRESSURES, LIQUID WATER PENETRATION, AND WATER VAPOR PRESSURES <br />WITHOUT FAILURE DUE TO DEFECTIVE MANUFACTURE OF PRODUCTS. <br />I. WEATHER BARRIER <br />A.COMMERCIAL BUILDING WRAP: ASTM E2357 PASSED, ABAA (AIR BARRIER ASSOCIATION OF <br />AMERICA) EVALUATED AIR BARRIER ASSEMBLY, AND ASSEMBLY WATER RESISTANCE PER ASTM E331; <br />WITH FLAME-SPREAD AND SMOKE-DEVELOPED INDEXES OF LESS THAN 25 AND 450, <br />RESPECTIVELY, WHEN TESTED IN ACCORDANCE WITH ASTM E84; UV STABILIZED FOR NINE- <br />MONTH EXPOSURE; AND ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION. <br />1.BASIS-OF-DESIGN PRODUCT: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE <br />DUPONT DE NEMOURS, INC.; TYVEK COMMERCIALWRAP <br />J. WEATHER BARRIER FLASHING <br />1.BASIS-OF-DESIGN PRODUCT: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE <br />DUPONT DE NEMOURS, INC.; DUPONT™ FLEXWRAP™ <br />2.CONFORMABILITY: ABLE TO CREATE A SEAMLESS SILL PAN EXTENDING UP THE JAMBS <br />WITHOUT CUTS, PATCHES, OR FASTENERS. <br />3.WATER PENETRATION: NO LEAKAGE AT 15 PSF (720 PA) PER ASTM E331. <br />4.LOW TEMPERATURE ADHESION: EXCEEDS MINIMUM VALUE OF 1.5 LB./IN. (0.26N/MM) AT <br />25 DEG F (MINUS 4 DEG C) AS CLASS A (WITHOUT PRIMER USE). <br />5.ADHESION AFTER WATER IMMERSION: EXCEEDS MINIMUM VALUE OF 1.5 LB./IN. <br />(0.26N/MM), AFTER AAMA 800, SECTIONS 2.4.1.3.1/2.4.1.4.3, TEST B. <br />K. STRIP FLASHING: COMPOSITE FLASHING MATERIAL COMPOSED OF SPUNBONDED POLYETHYLENE <br />LAMINATE WITH 100 PERCENT BUTYL-BASED, DUAL-SIDED, ADHESIVE LAYER; AAMA 711, CLASS A (NO <br />PRIMER), LEVEL 3 THERMAL EXPOSURE, 176 DEG F (80 DEG C) FOR SEVEN DAYS. <br />1.BASIS-OF-DESIGN PRODUCT: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE <br />DUPONT DE NEMOURS, INC.; [DUPONT™STRAIGHTFLASH™ <br />2.WATER PENETRATION: NO LEAKAGE AT 15 PSF (720 PA) PER ASTM E331. <br />3.LOW TEMPERATURE ADHESION: EXCEEDS MINIMUM VALUE OF 1.5 LB./IN. (0.26N/MM) AT <br />25 DEG F (MINUS 4 DEG C) AS CLASS A WITHOUT PRIMER USE. <br />4.ADHESION AFTER WATER IMMERSION: EXCEEDS MINIMUM VALUE OF 1.5 LB./IN. <br />(0.26N/MM), AFTER AAMA 800, SECTIONS 2.4.1.3.1/2.4.1.4.3, TEST B. <br />L. BUILDING WRAP TAPE: PRESSURE-SENSITIVE PLASTIC TAPE RECOMMENDED BY WEATHER BARRIER <br />MANUFACTURER FOR SEALING JOINTS AND PENETRATIONS IN COMMERCIAL BUILDING WRAP. <br />1.BASIS-OF-DESIGN PRODUCT: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE <br />DUPONT DE NEMOURS, INC.; TYVEK® TAPE OR COMPARABLE PRODUCT. <br />M. EXAMINATION <br />A.EXAMINE SUBSTRATES, WITH INSTALLER PRESENT, FOR COMPLIANCE WITH REQUIREMENTS. <br />B.VERIFY THAT SUBSTRATE AND SURFACE CONDITIONS ARE IN ACCORDANCE WITH COMMERCIAL <br />WEATHER BARRIER MANUFACTURER RECOMMENDATIONS PRIOR TO INSTALLATION. <br />1.VERIFY THAT ROUGH SILL FRAMING FOR DOORS AND WINDOWS IS SLOPED <br />DOWNWARDS TOWARDS THE EXTERIOR AND IS LEVEL ACROSS WIDTH OF THE OPENING. <br />C. VERIFY THAT SURFACES TO RECEIVE WEATHER BARRIER FLASHING ARE CLEAN, DRY, AND FREE <br />OF FROST. <br />D.PROCEED WITH INSTALLATION ONLY AFTER UNSATISFACTORY CONDITIONS HAVE BEEN <br />CORRECTED. <br />N. PREPARATION <br />A.DIRECT WATER ONTO AN ACCEPTABLE WEATHER BARRIER DRAINAGE PLANE WITH AN <br />UNOBSTRUCTED PATH TO EXTERIOR OF WALL. <br />1.PROVIDE A DRAINAGE PATH FOR WATER INTRUSION THROUGH WINDOW AND DOOR <br />ATTACHMENT SYSTEM THAT COLLECTS AT WINDOW AND DOOR SILLS AND DIRECTS WATER <br />TO THE EXTERIOR OR WEATHER BARRIER. <br />O. COMMERCIAL BUILDING WRAP INSTALLATION <br />A.GENERAL: COMPLY WITH WEATHER BARRIER MANUFACTURER'S WRITTEN INSTALLATION <br />GUIDELINES AND WARRANTY REQUIREMENTS. <br />B.COVER EXPOSED EXTERIOR SURFACE OF SHEATHING WITH WEATHER BARRIER SECURELY <br />FASTENED TO FRAMING IMMEDIATELY AFTER SHEATHING IS INSTALLED. <br />1.MAINTAIN CONTINUITY OF AIR AND WATER BARRIER ASSEMBLIES. <br />2.START WEATHER BARRIER INSTALLATION AT A BUILDING CORNER, LEAVING 12 INCHES <br />(300 MM) OF WEATHER BARRIER EXTENDED BEYOND CORNER TO OVERLAP. <br />3.INSTALL WEATHER BARRIER HORIZONTALLY STARTING AT LOWER PORTION OF WALL <br />SURFACE. <br />4.PROVIDE MINIMUM 6 INCHES (150 MM) OVERLAP AT HORIZONTAL- AND VERTICAL-WRAP <br />SEAMS IN A SHINGLE MANNER TO MAINTAIN CONTINUOUS DOWNWARD DRAINAGE <br />PLANE AND AIR AND WATER BARRIER. <br />C. SEAMS: SEAL SEAMS WITH BUILDING WRAP TAPE PER MANUFACTURER'S RECOMMENDED <br />INSTALLATION INSTRUCTIONS. <br />1.SHIPLAP HORIZONTAL SEAMS IN WEATHER BARRIER TO FACILITATE PROPER DRAINAGE. <br />D.FASTENERS: USE WEATHER BARRIER MANUFACTURER'S RECOMMENDED FASTENERS TO SECURE <br />WEATHER BARRIER AND INSTALL FASTENERS ACCORDING TO WEATHER BARRIER MANUFACTURER'S <br />INSTALLATION GUIDELINES. <br />1.DO NOT USE TEMPORARY FASTENERS TO PERMANENTLY ATTACH WEATHER BARRIER. <br />2.DO NOT PLACE FASTENERS WITH GASKETING WASHERS WHERE WEATHER BARRIER <br />FLASHING WILL BE INSTALLED. <br />3.INSTALL FASTENERS WITH GASKETING WASHERS THROUGH FLASHING WHERE <br />RECOMMENDED BY MANUFACTURER. <br />E. OPENINGS: COMPLETELY COVER OPENINGS WITH WEATHER BARRIER, THEN CUT WEATHER <br />BARRIER MEMBRANE TO OPENINGS IN ACCORDANCE WITH WEATHER BARRIER MANUFACTURER'S <br />INSTALLATION GUIDELINES. <br />1.PROVIDE HEAD AND JAMB FLAPS AND SEAM OVERLAPS TO MAINTAIN CONTINUOUS <br />DRAINAGE. <br />2.REPAIR DAMAGE TO WEATHER BARRIER USING METHOD RECOMMENDED BY WEATHER <br />BARRIER MANUFACTURER. <br />3.INSTALL FLASHING IN ACCORDANCE WITH WEATHER BARRIER MANUFACTURER'S <br />INSTALLATION GUIDELINES. <br />P. WEATHER BARRIER FLASHING INSTALLATION <br />A.INSTALLATION: REMOVE WRINKLES AND BUBBLES, REPOSITION WEATHER BARRIER AS <br />NECESSARY TO PRODUCE A UNIFORM, SMOOTH SURFACE. <br />1.ENSURE THAT AMBIENT AND SUBSTRATE SURFACE TEMPERATURES ARE ACCEPTABLE IN <br />ACCORDANCE WITH MANUFACTURER INSTRUCTIONS AND RECOMMENDATIONS. <br />2.WIPE SURFACES TO REMOVE MOISTURE, DIRT, GREASE AND OTHER DEBRIS THAT COULD <br />INTERFERE WITH ADHESION. <br />3.APPLY WEATHER BARRIER MANUFACTURER'S RECOMMENDED PRIMER OVER CONCRETE, <br />MASONRY, AND GLASS-MAT GYPSUM WALL SHEATHING SUBSTRATES TO RECEIVE WEATHER <br />BARRIER FLASHING. <br />4.LAP WEATHER BARRIER FLASHING A MINIMUM OF 2 INCHES (50 MM) ONTO WEATHER <br />BARRIER. <br />5.APPLY PRESSURE OVER ENTIRE SURFACE USING ROLLER OR FIRM HAND PRESSURE <br />B.ROUGH OPENINGS: SHIPLAP FLASHING WITH WEATHER BARRIER IN A SHINGLE MANNER TO <br />MAINTAIN A CONTINUOUS DOWNWARD DRAINAGE PLANE AND AIR AND WATER BARRIER IN <br />ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS. <br />1.APPLY 6-INCH-(150-MM-)WIDE CONFORMABLE WEATHER BARRIER FLASHING AT DOOR <br />AND WINDOW SILLS. <br />2.ENSURE THAT SILL FLASHING DOES NOT SLOPE TO THE INTERIOR. <br />3.INSTALL BACKER ROD IN JOINT BETWEEN FRAME OF OPENING PRODUCT AND FLASHED <br />ROUGH OPENING ON THE INTERIOR. <br />4.APPLY SEALANT OR CLOSED-CELL POLYURETHANE FOAM INSULATION AROUND ENTIRE <br />OPENING/FENESTRATION PRODUCT TO CREATE AIR SEAL AROUND INTERIOR PERIMETER <br />OF WINDOW OPENINGS IN ACCORDANCE WITH WEATHER BARRIER MANUFACTURER'S <br />INSTRUCTIONS. <br />5.AROUND DOOR AND WINDOW OPENINGS, APPLY BUTYL-BASED FLASHING TO FLAPS OF <br />WEATHER BARRIER. <br />6.USE STRIP FLASHING WITH WRAP CAP SCREWS TO SECURE HEAD FLAP OF THE WINDOWS. <br />C. PENETRATIONS: APPLY WEATHER BARRIER MANUFACTURER'S RECOMMENDED WEATHER <br />BARRIER FLASHING PATCHES BEHIND FASTENING PLATES, SUCH AS BRICK-TIE BASE PLATES, METAL- <br />FLASHING CLIPS, AND METAL CHANNELS. <br />1.SEAL WEATHER BARRIER AROUND EACH PENETRATION WITH WEATHER BARRIER <br />MANUFACTURER'S RECOMMENDED SELF-ADHERED FLASHING PRODUCT OR SEALANT. <br />INTEGRATE PRODUCTS WITH FLANGES INTO THE WEATHER BARRIER. <br />D.TERMINATIONS: PROVIDE MINIMUM 2 INCHES (50 MM) OVERLAP USING STRIP FLASHING ON <br />ADJOINING ROOF AND BASE OF WALL SYSTEMS TO MAINTAIN CONTINUOUS DOWNWARD <br />DRAINAGE PLANE. <br />1.SECURE WEATHER BARRIER WITH FASTENERS AND WEATHER BARRIER FLASHING. <br />Q. CLEANING <br />A.IMMEDIATELY REMOVE RELEASE PAPER AND SCRAP FROM WORK AREA AND DISPOSE OF <br />MATERIAL. <br />R. PROTECTION <br />A.PROTECT INSTALLED WEATHER BARRIER FROM THE FOLLOWING: <br />1.DAMAGE FROM CLADDING, STRUCTURE, OR A COMPONENT OF THE STRUCTURE (FOR <br />EXAMPLE, WINDOW, DOOR, OR WALL SYSTEM). <br />2.CONTAMINATION FROM BUILDING SITE CHEMICALS, PREMATURE DETERIORATION OF <br />BUILDING MATERIALS, OR NONSTANDARD USE OR APPLICATION OF PRODUCTS. <br />3.FOREIGN OBJECTS OR AGENTS, INCLUDING THE USE OF MATERIALS INCOMPATIBLE <br />WITH WEATHER BARRIER PRODUCTS. <br />4.UV EXPOSURE IN EXCESS OF PRODUCTS' STATED LIMITS. <br />7.5 WEATHER BARRIERS <br />M. STEVEN <br />CAMP <br />C-18,407 <br />JUN. 30, 2027 <br />RENEWAL DATESTATEOFCALIFORNIA <br />LICENSED A RCHITECT <br />PROJECT ARCHITECT: <br />PROJECT MANAGER: <br />DRAWN BY: <br />PROJECT NUMBER: <br />All ideas, designs and plans indicated or represented <br />by these drawings are owned by and are the property <br />of Elements Architecture, Inc. and were created and <br />developed for use in connection with the specified <br />project. None of such ideas, designs, or plans shall <br />be used for any purpose whatsoever without the <br />written permission of Elements Architecture. <br />Elements Architecture, Inc. <br />PROJECT NAME: <br />NO.DESCRIPTION DATE <br />M. Steven Camp, AIA <br />Scott Holland, AIA <br />PROJECT ADDRESS: <br />SHELLEY MACDONALD <br />EA <br />SHELLEY MACDONALD <br />STAMPED/SIGNED: 04/08/2026 <br />4/ <br />9 <br />/ <br />2 <br />0 <br />2 <br />6 <br /> <br />7 <br />: <br />5 <br />2 <br />: <br />5 <br />6 <br /> <br />A <br />M <br />21.105 <br />TENANT <br />IMPROVEMENT <br />(PHASE 3) <br />2909 DAIMLER STREET <br />SANTA ANA, CA 92705 <br />A9.2 <br />SPECIFICATIONS <br />COMPASS BIBLE CHURCH, <br />TUSTIN SANTA ANA