My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
KIMLEY-HORN (2)
Clerk
>
Contracts / Agreements
>
K
>
KIMLEY-HORN (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/12/2021 4:01:57 PM
Creation date
7/20/2018 12:19:18 PM
Metadata
Fields
Template:
Contracts
Company Name
KIMLEY-HORN
Contract #
A-2018-160-01
Agency
PUBLIC WORKS
Council Approval Date
6/19/2018
Expiration Date
6/18/2021
Insurance Exp Date
4/1/2022
Destruction Year
2026
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
89
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
v <br />We will prepare a report presenting the results of field exploration, geoteohnical laboratorytesting, and engineering <br />analyses, as well as conclusions andt`abOrnMendations relative to the project. <br />Deliverables:. Draft Pavement and $oil Matarlal Roport, Final Pavement Report. and ,doll Material Report, <br />Task 4. Survey (Options A and 81 <br />+; <br />.... ......... .............................. ....... ....... ,........... <br />The Kimsey -Horn team will provide aerial mapping with supplemental ground surveys at a scale of I" = 20' with 50 feet <br />t <br />interval cross sectlons along streets as well as.tho,project area for pump stations, This enoom asses survey record <br />P <br />collection; establishment of horizontal and vertical controls; mohumant and centerlino tie prasarvatipn.; and establishment <br />Co <br />of temporary banohrnarks. Existing features such as utility covers, pavementtimits, private properly improvements, curb <br />ramps, driveways, curb andguiters, sidewalks, street lights and poles, and trafto starts and striping will be surveyed <br />where needed forthe proposed design and added to the base maps. Existing right-of-way will be Input per readily <br />available records. <br />'G <br />Deliverables; Mlcrostation V81 Files o0bpographlc Survey, XML Point File, DTM of extsting surface features. <br />Task 5: Hydra ullclHydrology (Option 8) <br />........ ....,..., ......., ............................... ... ......., .................,., <br />our team wilt prepare a Drainage Reportto address hydrology end hydraulics for the site per orange County <br />. <br />f, <br />)iydrology Manual and Prange County Locai Drainage Manual raqulrsments and will provide design recommendations. <br />r <br />Modifications are Intended to maintain existing drainage patterns and flows. Calculations will consist of comparing the <br />pre- end post -project conditions at the site, Catch basins Will be Incorporated Into design, where necessary, I.e. to limit <br />I <br />flooded width, and at low points. <br />F . <br />Deliverables: Draft hydrology and hydraulic analysis and drainago report, Final hydrology and hydraulic analysis and <br />V t <br />drainage report. <br />�t <br />Task 6: Water Quality (Options A and S) <br />Kimlay-Horn will develop a WQMP for the project in compliance with, and meeting the requirements of order.No, <br />z <br />RO-20ON030INPDES No. CAS618030, of the Santa Ana Regional Water Quality Control Board. The WQMP will <br />f <br />Incorporate low impact development best management practices to the maximum extent practical. Foroxample, the use <br />of bioretentlon facilities within landscaped parkway areas will be in accordance with the United States Environmental <br />Protection Agency Green Street standards. If proprietary items are needed, these will be Indicated in compliance with the <br />City's adopted public contracting code. <br />t <br />Deliverables: Draft WQMP, Final WQMP <br />^: <br />Task 7. Environmental Studies (Options A and 6) <br />.............................I............. ......................................................................... <br />t <br />Kimley»Horn Scope of Services assumes that an Initial Study leading to a Mitigated Negative Declaration (IS/ MND) is <br />the appropriate CEQA documentation for the proposed project. Tha I$ will provide the necessary background. Each of <br />the topics contained In the Environmental Checklist will be evaluated to document the nature and extent of any potential <br />environmental consequences and the need for mitigation. During the preparation of the IS should it be determined that <br />the project could have signiflcant Impacts that cannot be fully mlilgated, we will work with the City to identify modifications <br />to the project that could reduce anticipated Impacts. Using the City's Initial Study Checklist, KimleyHom will respond to <br />each checklist question. The analysis will use the following technical studies and data prepared by our team: Traffic Impact <br />Study, Air Quality and Greenhouse Gas Study, Noise Study, Utilities/ Infrastructure, Geotechnical Study, Drainage, Concept <br />WQMP, and a Phase I Environmental Site Assessment. All other environmental topics would be studied qualitatively. <br />Dollverables: Initial Study leading to a Mitigated Negative Declaration (IS/MND). <br />Ki mlepMorn 'le TROG77025.171 City of go On Ana <br />
The URL can be used to link to this page
Your browser does not support the video tag.