My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
MICHAEL BAKER, INC.
Clerk
>
Contracts / Agreements
>
M
>
MICHAEL BAKER, INC.
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2021 5:20:27 PM
Creation date
8/7/2018 12:56:56 PM
Metadata
Fields
Template:
Contracts
Company Name
MICHAEL BAKER, INC.
Contract #
A-2018-177
Agency
Public Works
Council Approval Date
7/17/2018
Expiration Date
7/17/2021
Insurance Exp Date
8/30/2021
Destruction Year
2026
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
91
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
bCtats,r <br />Civic Center 5tarmwoterLi ftStoWn Renovcsten Design Services �" <br />• Removal of three (3) existing pumps and motors and Install four (4) new vertical shaft driven <br />dry pit screw type pumps and motors equipped with flywheels. <br />• Removal of three (3) existing in-line grinders and Install 8 -inch diameter suction pipe and <br />eccentric reducers at all four (4) pump locations. <br />• Removal of existing 4 -inch and 6 -Inch discharge pipe and valves at three (3) pump locations <br />and replace with 8 -inch diameter discharge pipe, plug valves and eccentric reducers at all <br />four (4) pump locations. <br />• Removal of existing 6 -Inch swing check valves and replace with 8 -inch non -slam rubber <br />flapper swing check valves. <br />Avalon Catherine Booster Station and Pebbly Beach Lift Station CIP Projects, Avalon, <br />California. City of Avalon. Electrical Engineering Task Manager. Michael Baker provided design <br />and construction services for the Avalon Sewer CIP Electrical Improvements Project that <br />consisted of upgrades to electrical infrastructure for the Catherine Booster Station and Pebbly <br />Beach Lift Station, including City SCADA integration, The Catherine Booster Station required <br />replacement of the existing Motor Control Center (MCC) line-up with a new MCC panel and <br />included the following tasks: removing of existing MCC panel and replace with new NEMA 4X <br />rated MCC. MCC panel line-up included the control panel with Mission Communication RTU <br />and SCADA communication equipment; replacing existing cables to (2) 120 HP booster pumps; <br />replacing main 400 amp feeder incoming to the new MCC panel; reconnecting all existing <br />equipment to new panel including ATM power next to panel; reconnecting existing <br />instrumentation, control and signal wires to new panel terminal strip; providing conduits entering <br />or leaving the vault with the approved duct seal. The project also included heatertfan system to <br />prevent condensation; panes lighting and duplex 20A 110 VAC power plug; Ethernet switch; <br />phone Jack to access existing telephone connection and Sensaphone RTU; spare 1/0 cards for <br />future SCADA upgrade in panel, etc.; and providing specification and engineering cost estimate. <br />The Pebbly Beach Lift Station required removal of the existing Edison Meter Switchboard and <br />electrical distribution equipment from the vault and installing the new NEMA 4X rated meter <br />main and distribution equipment above ground level. The project included the following tasks; <br />coordination with SCE; removal of existing NEMA 1 rated Edison Meter Switchboard from the <br />dry pit and replace it with new 250 Amps NEMA 4X rated Metered Switchboard; intercepting <br />existing Edison conduit and re-routing to new meter panel; removal of NEMA 1 rated City - <br />owned Auto Transfer Switch (ATS) from the dry pit and replace it with new 250 Amps NEMA 4X <br />rated above ground ATS; removal of sub panel and step down transformer from the dry pit and <br />replaced It with NEMA 4X rated Mini Power Center (MPC) panel above ground; replacement of <br />non -explosion proof lights, receptacles, sensors and auxiliaries with the explosion proof <br />equipment in the dry pit; providing explosion proof fittings/seals for all cables entering or leaving <br />the vault (dry pit). <br />La Sierra Pipeline and Pumping Station Project, Riverside County, California. Western <br />Municipal Wafer District, Provided QA/QC for the project design for electrical and control <br />systems and evaluated project constructability. Michael Baker Is providing engineering and <br />design services for La Sierra Pipeline and Pumping Station Project. The client provides drinking <br />water to customers located within a 510 -mile district of western Riverside County. Water <br />resources include treated surface water and treated groundwater. The surface water is imported <br />from Northern California and treated at the Mills water treatment plant. The local groundwater is <br />treated at the Chino II Desaiter and the Arlington Desalter, Michael Baker assisted in designing <br />facilities to transfer treated groundwater to a residential area of the district where customers are <br />currently receiving water from the Mills water treatment plant only. <br />r�wty� aaiMarek Przywara, P. <br />
The URL can be used to link to this page
Your browser does not support the video tag.