My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Item 26 - EIR No. 2020-03 and GPA No.2020-06 Santa Ana General Plan Update
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2022
>
02/15/2022 Regular
>
Item 26 - EIR No. 2020-03 and GPA No.2020-06 Santa Ana General Plan Update
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/3/2024 4:44:49 PM
Creation date
8/16/2023 11:49:02 AM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Agency
Clerk of the Council
Item #
26
Date
2/15/2022
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
413
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
With implementation of Mitigation Measures N-2, N-3, and N-4, coupled with adherence to <br />associated performance standards, Impact 5.12-3 would be reduced to less -than -significant <br />levels. Specifically, Mitigation Measure N-2 would reduce potential vibration impacts during <br />construction below the pertinent thresholds, and Mitigation Measures N-3 and N-4 (operations - <br />related vibration) would reduce potential vibration impacts from commercial/industrial uses and <br />proposed uses near existing railroads and facilities to less -than -significant levels. No significant <br />and unavoidable vibration impacts would remain. <br />Operational Vibration Impacts. Commercial and industrial operations within the plan area would <br />generate varying degrees of ground vibration, depending on the operational procedures and <br />equipment. Such equipment -generated vibrations would spread through the ground and diminish <br />with distance from the source. The effect on buildings in the vicinity of the vibration source varies <br />depending on soil type, ground strata, and receptor -building construction. The results from <br />vibration can range from no perceptible effects at the lowest vibration levels, to low rumbling <br />sounds and perceptible vibrations at moderate levels, to slight structural damage at the highest <br />levels. In addition, future sensitive receptors could be placed within close proximity to existing <br />railroad lines through buildout in the plan area. <br />Because specific project -level information is not available at this time, it is not possible to quantify <br />future vibration levels at vibration -sensitive receptors that may be near existing and future <br />vibration sources. <br />With implementation of Mitigation Measures N-2, N-3, and N-4, coupled with adherence to <br />associated performance standards, Impact 5.12-3 would be reduced to less -than -significant <br />levels. Specifically, Mitigation Measure N-2 would reduce potential vibration impacts during <br />construction below the pertinent thresholds, and Mitigation Measures N-3 and N-4 (operations - <br />related vibration) would reduce potential vibration impacts from commercial/industrial uses and <br />proposed uses near existing railroads and facilities to less -than -significant levels. No significant <br />and unavoidable vibration impacts would remain. <br />Mitigation Measures <br />N-2 Prior to issuance of a building permit for a project requiring pile driving during <br />construction within 135 feet of fragile structures, such as historical resources, 100 feet <br />of non -engineered timber and masonry buildings (e.g., most residential buildings), or <br />within 75 feet of engineered concrete and masonry (no plaster); or a vibratory roller <br />within 25 feet of any structure, the project applicant shall prepare a noise and vibration <br />analysis to assess and mitigate potential noise and vibration impacts related to these <br />activities. This noise and vibration analysis shall be conducted by a qualified and <br />experienced acoustical consultant or engineer. The vibration levels shall not exceed <br />Federal Transit Administration (FTA) architectural damage thresholds (e.g., 0.12 <br />inches per second [in/sec] peak particle velocity [PPV] for fragile or historical <br />resources, 0.2 in/sec PPV for non -engineered timber and masonry buildings, and 0.3 <br />in/sec PPV for engineered concrete and masonry). If vibration levels would exceed <br />Santa Ana General Plan Update <br />CEQA Findings of Fact and Statement <br />Of Overriding Considerations -34- <br />October 2021 <br />
The URL can be used to link to this page
Your browser does not support the video tag.