Laserfiche WebLink
Crooke Pump Station Func. Spec Dev & Programming Scope of Work ENTERPRISE <br />EA Project Number: EA23CSA090, 0.0.0 AUTOMATION <br />A A TETRA TECH COMPANY <br />also leverage standard template documents that EA has already developed as part of other <br />projects. The Functional Specification will define details such as: <br />• Narrative overview of the function and operation <br />• Identification of all physical site components <br />• Control narrative description for each component <br />• Process control strategy description <br />• Identification of 10, setpoints, commands, permissive, etc. <br />• Alarms <br />• Totalizers <br />• PLC standard device code modules to be used in programming <br />The intent of this document is to provide a high amount of detail and clarity to all groups working <br />on the controls systems at Crooke, especially the integrator responsible for programming. The <br />integrator will use this document to ensure the PLC program is consistent with those at other <br />remediated sites. <br />EA will submit the Functional Specification to the City for review. <br />5.5.5 SCADA Design Specification <br />Similar to the PLC Functional Specification, EA will develop a SCADA Design Specification to <br />detail the SCADA configuration for Crooke. This specification will be based on specifications in <br />which EA has developed for previous City projects and the City's standards and will leverage <br />standard template specification documents from other projects. <br />The SCADA Design Specification will define: <br />SCADA screens and their functions, content, operations, and navigation <br />Communication parameters <br />Tag and alarm list <br />This specification will ensure configuration by the integrator is thoroughly planned and consistent <br />with existing Dynac SCADA screens. <br />EA will submit the SCADA Design Specification to the City for review. <br />5.5.6 OIT Design Specification <br />Leveraging the City's OIT design standards and previously developed OIT Design Specification, EA <br />will develop an OIT Design Specification for Crooke. <br />The specification will define Crooke's OIT screens and popups. The screens will be designed to <br />use the graphic objects which EA has developed for previous site OITs. This specification will <br />ensure configuration by the integrator is thoroughly planned and consistent with those existing <br />OIT screens. <br />EA will submit the OIT Design Specification to the City for review. <br />