My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ASL CONSULTING ENGINEERS 3-2000
Clerk
>
Contracts / Agreements
>
A
>
ASL CONSULTING ENGINEERS 3-2000
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2012 3:25:51 PM
Creation date
3/19/2003 10:00:26 AM
Metadata
Fields
Template:
Contracts
Company Name
ASL CONSULTING ENGINEERS (TETRA TECH)
Contract #
A-2000-164
Agency
Public Works
Council Approval Date
10/2/2000
Expiration Date
7/1/2002
Insurance Exp Date
10/1/2001
Destruction Year
2007
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ADDITIONAL INFORMATION <br /> <br />San Carlos Reservoir <br />Seismic Rehabilitation <br /> <br />City of San Diego <br />Engineering and Capital <br />Projects Department <br />600 B Street, Suite 800 <br />San Diego, CA 92101 <br /> <br />Contact: Richard Leja <br /> 619/533-5200 <br /> <br />Construction Cost: $900,000 <br /> <br />Completion Date: 1997 <br /> <br />Seismic Evaluation of 0.20 <br />MG Bissell Elevated Tank <br /> <br />Southern California Water <br />Company <br />630 East Foothill Boulevard <br />San Dimas, CA 91773 <br /> <br />Contact: Ron Nottingham <br /> 909/394-7824 <br /> <br />Construction Cost: $538,000 <br />Completion Date: On Hold <br /> <br />Seismic .Evaluation of 0.25 <br />MG Miramonte Elevated <br />Tank <br /> <br />Southern California Water <br />Company <br />630 East Foothill Boulevard <br />San Dimas, CA 91773 <br /> <br />Contact: Ron Nottingham <br /> 909/394-7824 <br /> <br />Construction Cost: $870,000 <br /> <br />Completion Date: On Hold <br /> <br />Prepared preliminary and f'mal design for the rehabilitation and seismic <br />upgrade of this 30 year old 5.0 MG above grade, prestressed concrete <br />reservoir. Analysis included exterior and interior concrete <br />investigations to evaluate condition of prestressing wires and concrete <br />delamination; structural analysis for seismic and gravity loads; <br />Geotechnical investigations; and corrosivity investigation. <br />Recommended improvements included an interior ring wall, chemical <br />injection piping, recirculation pump, value vault, reservoir access, site <br />improvements, landscaping and tank coating. <br /> <br />This .20 MG, 125 feet high tank was constructed in 1940. The tank <br />shell consists of riveted steel plates and is supported by built-up, riveted <br />steel members. The tank and its foundation were originally designed <br />for a horizontal seismic force factor of 0.1 times the dead load of the <br />tank and contents. <br /> <br />ASL performed a seismic evaluation to determine the safe operating <br />water levels of the existing structure. ASL also performed three seismic <br />analyses for three different retrofit design alternatives in accordance <br />with current code standards. Cost estimates for each retrofit alternative, <br />as well as a replacement (new tank) cost were provided. <br /> <br />This .25 MG, 140 feet high tank was constructed in 1936. The tank <br />shell consists of riveted steel plates and is supported by built-up, riveted <br />steel members. The tank and its foundation were originally designed <br />for a horizontal seismic force factor of 0.1 time the dead load of the tank <br />and contents. <br /> <br />ASL performed a seismic evaluation to determine the safe operating <br />water levels of the existing structure. ASL also performed three seismic <br />analyses-for three different retrofit design alternatives in accordance <br />with current code standards. Cost estimates for each retrofit alternative, <br />as well as a replacement (new tank) cost were provided. <br /> <br />ASL Consultin~l En~lineers <br /> <br />City of Santa Ana <br />ELEVATED WATER TANK IMPROVEMENTS : 18 <br /> <br /> <br />