Laserfiche WebLink
290 <br /> <br />such trench is excavated; the laying in each of said sewer trenches <br />of a lateral house connection sewer constructed of four (~) inch <br />inside diameter vitrified salt glazed cylindrical sewer pipe con- <br />neoted with the eaid main sewer pipe line and extending from said <br />Main sewer pipe line to the inside of said curb; and the backfilling <br />and eettii~g Cf eanh of said eewer trenches to a true and solid <br />surface on the subgrade. <br /> <br /> '(c) The proper excavation for and the construction across <br />North ~ain Street, at the intersection thereof by Tenth Street, alee <br />an open public Street in the city of Santa Ann, of a twil culvert <br />constructed of re-inforoed c'oncrete, each part thereof to be <br />twentY~four (2~) inches wide at the top and bottom and nine (9) <br /> <br /> inches in depth inside measurement. <br /> <br /> (d) The proper excavation for and the construction across <br /> <br /> North Main Street, at the intersection thereof by Washington <br /> Avenue, also an open public street in the city of Santa Ann, of <br /> a twil culvert constructed of re-inforced concrete, each part <br /> thereof to be twenty-four (2~) inches wide at the top and bottom, <br /> and Six (6) inches in depth inside measurement. <br /> <br /> (e) The proper excavation for and the construction across <br /> <br /> North Main Street, at the intersection thereof by Seventeenth <br /> Street, also an open public street in the city of Santa Ann, of a <br /> twin culvert constructed of re-inforoed concrete, each part there- <br /> of to be twenty-four (2~) inches wide at the top and bottom and <br /> eight (6) inches in depth inside measurement. <br /> <br /> (f) The construction for the purpose of lighting North ~ain <br />Street of an ornamental double eoheduled series street lighting <br />system to consist of eighty-two (62) type 1500 Marbelite con- <br />crete lighting standards, each erected on a oonarete base, the base <br />to be constructed on a levelwith , inside of, and along the line <br />of the top of the ourb~ forty-one (~1) of said light standards to <br />be erected on each eide. of North Main Street, at the points desig- <br />nated upon the detailed plane, and connected with a loop syetsm of <br />one and one-quarter (lb') inch eheradized iron conduit and two no. <br />8 insulated lead covered cables, each light standard fitted with a <br />two hundred fifty (250) candle-power Type 'C' 6.6 Ampere la~p, and <br />General Electric Form 6 Novalux Ornamental Unit on the top, and <br />one 80 candle-power Type 'C' 6.6 Ampere lamp with fourteen (1~') <br />inch round globe suspended from the end of each side arm. <br /> <br /> Excepting from the work above described any of said work al- <br />ready done upon North Main Street to the official grade. <br /> <br /> Excepting, however, from all of the afore described work <br /> <br />other than lateral house connection sewers and trenches the portion <br />thereof within any area which ia required by law to be kept in order <br />and repair by amy person or company having railroad tracks on North <br />Main Street. <br /> <br /> <br />