Laserfiche WebLink
installed. No lateral shall be left exposed after inspection is <br />approved but shall be irm~ediately covered with earth." <br /> <br />(E) That Section 103 of said Plumbing Code is hereby amended so as to read <br /> <br />as follows: <br /> <br />"Section 103. Washin~ Machines~ and other fixtures not connected <br /> to water suppl~. <br /> <br /> Washing machines which have no direct water connee.tion with <br />the domestic water supply of the City of Santa Ana, may have their <br />waste pipes connected into the fixture side of the trap which serves <br />another fixture provided however, that such fixture trap is of the <br />design commonly known as the Los Angeles pattern. The waste inlet <br />for the washing machines into said trap shall in all cases be at <br />least one (1) inch above the water line of the trap seal and be <br />equipped with an inlet cover and chain." <br /> <br />(F) That Section 120 of said Plumbing COde is hereby amended by the addition <br /> <br />thereto at the end of the present Section 120 and as a part of said Section the <br /> <br />following: <br /> <br /> "No urinal vent pipe shall be less than two (2) inches in <br />internal diameter." <br /> <br />(G) That Section 126 of said Plumbing Code is hereby amended so as to read <br /> <br />as follows: <br /> <br />"Section 126. Galvanized and Cast Iron Vents. <br /> <br /> Every ventilating pipe or stack shall be carried through the <br />roof to the outer air, and every vent pipe shall be constructed of <br />cast iron soil pipe with cast iron soil fittings, or malleable <br />galvanized iron or steel screw pipe, with galvanized malleable iron, <br />galvanized cast iron, or galvanized "Durham" recessed fittings, pro- <br />vided however, that the building wherein such pipe shall be installed <br />is constructed with fire walls, such vents shall be carried at least <br />six (6) inches above the level of such fire walls, and shall pass <br />through the roof at a distance of not less than twelve (12) inches <br />from any fire wall. Such vents shall not terminate within eight (8) <br />feet of any property line, window, air shaft or opening into any <br />house or building, provided however, that such vent pipes may terminate <br />closer than eight (8) feet but not closer than two (2) feet to any <br />opening on the roof which is equipped with a hood, cap, Jack, or other <br />apparatus acceptable to the plumbing department, and which is so con- <br />structed to prevent reverse circulation of air through such openings, <br />provided however, that a ventilating pipe or stack shall not terminate <br />lower than the highest point of the wall against which it is erected. <br /> <br /> All ventilating pipes and stacks shall be left ~pen and unobstructed, <br />and be reamed to the full size capacity of the pipe. <br /> <br />(H) That Section 154 of said Plumbing Code is hereby ~nended so as to read <br /> <br />as follows: <br /> <br />"Section 154. Water Softeners and Other Fixtures Connected Directl~ <br /> to Water Supply. <br /> <br /> A plumbing per~it shall be required for the installation of all <br />w~ter softeners, water operated~ manual, or automatic water pumps or <br />lifts, gas operated water cooled r~frigerators, water cooled motors, <br />compressors and air conditioning units, cooling towers, hydraulic <br />elevator and all other similar fixtures, appliances, appurtenances or <br />piping for the operating of which a connection with the water system <br />of the City of Santa Aha is required or made, and a notice of inspect- <br />ion filed in the office of the Plumbing Inspector. <br /> <br /> No water softeners, water operated, manual or automatic pum~ or <br />lift, gas operated water cooled refrigerator, water cooled motor, <br />compressor, or air conditioning unit, cooling towers, hydraulic elevators <br />or any other fixture or fixtures, appliances, appurtenances or piping <br />(exeept toilets and bidets) for the mechanical operation of which, a <br />connection with the water system of the City of Santa Ana is required <br />or made, or any other similar fixture, appliance or appurtenance now <br />in use or hereafter installed shall have any outlet, inlet, supply or <br />waste pipes, or any part or parts thereof connected directly with the <br />sewer or cesspool system, but shall when wasted i~to the sewer or <br />cesspool system discharge its waters or waste waters over and above the <br />highest water line of, and into an approved open plumbing fixture <br />properly trapped, vented and supplied with water. <br /> <br /> No system of water piping containing water supplied by or from <br />the domestic water system of the City of Santa Ana shall have _any <br />connection whatever with any other water supply, nor shall it <br /> be <br />installed or connected in such a m~nner or position as to permit the <br />back flow or stphonage into the piping of the water supply of the City <br />of Santa Ana, water or liquids from any source whether in containers <br />or otherwise. <br /> <br /> <br />