Laserfiche WebLink
<br />" <br /> <br />4. <br /> <br />:W-.;'-{ <br /> <br />,,~~~~~~p <br />\'J'~L.. <br /> <br />-.,"....;'," 1- .'n <br />'''<r i -:<:~:,,- ~~-':;. - <br />.n.'._ _ -...... '_:'>' .,-'i' - i_,:-:t:~-':'~i'~_;~':~:-*~;Ji;~'~"~~<:;'--:,::,~j;1, <br />~reCiuired as part of the;P\ojqCr. (pfrrh.e'ptp)ic.t'pl'a'ns)or whether others will perform them, such as MWD or <br />SCEf?~?!am~~e. i\Jl cohst~ucri~nel~~tswillbe clearly defined. <br /> <br />Prrpaf~~~en (~)~da(h'!caylmpiovemeit Plan. & Profile Sheets ar I" = 20' scale showing the proposed <br />roadway'widr~~g,rehabilita~ioi\'; 'ADA ramps, sidewalks and srorm drain lareral (in plan view) construcrion <br />elements ilia(conformto the approved concepts. All construction elements will be clearly defined. <br /> <br />Prepare four (4) Cul-de-sac Improvement Plan Sheets ar I" = 20' scale showing rhe proposed cul-de-sac <br />construction (with elevations in plan view only) and storm drain lateral construction (in plan view) that <br />conform ro rhe approved concepts. All construction elements will be clearly defined. <br /> <br />Prepare four (4) "Wide" Parkway Grading Plan Sheers at 1" = 20' scale showing the proposed "wide" <br />parkway grading (wirh elevations in plan view only) rhat conforms ro rhe approved conceprs. All construction <br />elements would be clearly defined. Note: Areas of "narrow" parkway grading will be addressed on the Roadway <br />Improvement Plan Sheets and per the Typical Sections (typically a 2% plane with or without retaining at join <br />point). <br /> <br />Prepare two (2) Storm Drain Lateral Profile & Detail Sheers showing rhe proposed srorm drain lareral <br />Profiles, typical trench section(s) and the various storm drain related derails required. <br /> <br />Prepare seven (7) Sound Wall Plan & Profile Sheets at 1" = 20' scale showing rhe proposed sound wall <br />(3,650' +/-) consrrucrion elements rhat conform to the approved conceprs, including the profiles of proposed <br />top of wall and top of footing and profiles of rhe existing grades at front and back of wall. Any retaining wall <br />requirements would also be addressed. All construcrion elements will be clearly defined. <br /> <br />Prepare two (2) Sound Wall Typical Section & Detail Sheets showing rhe proposed sound wall typical <br />sections and various details required. <br /> <br />Prepare four (4) Traffic Signal Modification Plan Sheets, rwo for the Bishop Street inrersecrion and rwo for <br />the McFadden Avenue intersection, consisting of plan view only sheets at 1" == 20' scale, showing the proposed <br />schedule of poles, conduits, conductors, phasing, details, poims of electrical connection, service meter, <br />controller location, construction notes, loops and general notes. Note: The additional plan sheet is typically <br />required for each intersection in order to have adequate room for the plan view, charts, tables and details. <br /> <br />Prepare four (4) Bristol Street Signing & Striping Plan Sheets, consisting of plan view only sheers ar I" = 40' <br />scale, showing the proposed signing and striping types, transition areas beyond the proposed widening at each <br />end of the project, details, applicable standard plan references, construction notes and general notes. Loop <br />replacements will be per TS modificarion plans. <br /> <br />Prepare two (2) Traffic Signal Intercounect Plan Sheets consisring of plan view only sheers at 1" " 40' <br />scale, showing the proposed Traffic Signal Inrerconnect system, conduirs, conductors, pull boxes, derails, <br />construction notes, points of connection at each end and general notes. <br /> <br />Prepare two (2) Streerlight Plan Sheets consisting of plan view only sheers at I" = 40' scale, showing the <br />proposed pedestrian and vehicular streetlight poles, conduits, conductors, pull boxes, details, construction <br />notes, points of electrical connection, service meter and general notes. <br /> <br />Prepare up to eight (8) Traffic Control & Phasing Plan Sheets consisting of plan view only sheets at 1" = <br />40' scale, showing the proposed traffic control and phasing requirements, temporary construction signage, <br />srriping and warning equipment in conformance with Federal MUTCD 2003 and California Supplemenr <br />requirements and applicable general notes. <br /> <br />Prepare six (6) Landscape Planting Plan Sheets ar 1" = 20' scale showing rhe proposed planring consrrucrion <br />elements that conform to the approved concepts. All construction elements will be dearly defined. <br /> <br /> <br />~-_::;;;<-:; <br /> <br />(a, <br /> <br /> <br />~-<'''''''''''..'...N,.'.'' <br />. . '.- --"""-. ."-'.-: . - .' <br />.,,, .,.: ...",." <br /> <br />5. <br /> <br />6. <br /> <br />7. <br /> <br />8. <br /> <br />9. <br /> <br />10. <br /> <br />11. <br /> <br />12. <br /> <br />13. <br /> <br />14. <br /> <br />15. <br /> <br />II I Harris & Associates. <br /> <br />Bristol Corridor Widening w Pnase I <br />Page-14- <br />