My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
CORDOBA CORPORATION 2
Clerk
>
Contracts / Agreements
>
_PENDING FOLDER
>
READY TO DESTROY IN 2020
>
CORDOBA CORPORATION 2
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2015 4:28:23 PM
Creation date
11/25/2009 11:43:31 AM
Metadata
Fields
Template:
Contracts
Company Name
CORDOBA CORPORATION
Contract #
A-2009-122
Agency
Public Works
Council Approval Date
8/3/2009
Expiration Date
12/31/2011
Insurance Exp Date
1/20/2013
Destruction Year
2018
Notes
Amended by A-2011-272, A-2012-137, -01, A-2009-122-01, -02, -03
Document Relationships
CORDOBA CORPORATION 2A
(Amended By)
Path:
\Contracts / Agreements\_PENDING FOLDER\READY TO DESTROY IN 2020
CORDOBA CORPORATION 2B
(Amended By)
Path:
\Contracts / Agreements\_PENDING FOLDER\READY TO DESTROY IN 2020
CORDOBA CORPORATION 2C
(Amended By)
Path:
\Contracts / Agreements\_PENDING FOLDER\READY TO DESTROY IN 2020
CORDOBA CORPORATION 2D
(Amended By)
Path:
\Contracts / Agreements\_PENDING FOLDER\READY TO DESTROY IN 2020
CORDOBA CORPORATION 2E
(Amended By)
Path:
\Contracts / Agreements\_PENDING FOLDER\READY TO DESTROY IN 2020
CORDOBA CORPORATION 2F
(Amends)
Path:
\Contracts / Agreements\_PENDING FOLDER\READY TO DESTROY IN 2020
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
87
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
criteria of major fixed guideway facilities/systems <br />• Selected vision concepts to illustrate station character within a typical station area <br />• Selected vision concepts that illustrate major design elements of the proposed fixed <br />guideway alignments in light of the surrounding community. <br />• Locations and functional layouts for up to two alternative maintenance & storage facility <br />site locations for the Build Alternatives. Provision of concepts and identification of <br />approximate locations of support and system facilities (e.g., substations) on the plan <br />view drawings. <br />• Assessment of utility impacts and relocation needs <br />• Identified limits and description of major surface and street modifications that would be <br />required (e.g., traffic, drainage, and other major elements) <br />• Preliminary Operating Plans, including any major transit system changes needed to <br />accommodate and interface with existing transit operations <br />Task 6.1 Corridor Mapping <br />Digitized aerial corridor mapping suitable for conceptual engineering will be provided by the City <br />of Santa Ana. High Definition Scanning (HDS) will be used to obtain detailed topographic <br />information along the project corridor with minimal impact to the motoring public. These surveys <br />will include major existing improvements, traffic configurations and other as -built street <br />conditions. The data collected will augment the existing aerial corridor mapping provided by the <br />city of Santa Ana. The data will be incorporated with existing right of way base mapping and can <br />be used throughout the design of the project. We will also conduct right-of-way mapping along <br />the entire project limits, dispatching a field crew to survey all centerline monuments, calculate <br />existing right of way from Assessor's Parcel Maps and utilize record maps in the area to <br />determine potential property takes. <br />Deliverable(s) — Enhanced Digitized Mapping of Build Alternative Alignment Stations and <br />Support Facilities <br />Task 6.2 Alignment and Station Locations <br />Task 6.2.1 Track, Roadway, Civil Structural and Systems Design Concepts <br />The Cordoba team will prepare plan sets drawings for the Build Alternatives and any remaining <br />design/alignment options. This will include definition of the alignment, along with surface, and <br />elevated stations, structures, and major surface improvements. Conceptual design drawings of <br />the alignment will be prepared at a level of detail necessary to facilitate technical feasibility, cost <br />analysis and documentation of alternatives appropriate for an Alternatives Analysis. For the <br />most part, the conceptual alignments will be portrayed at a 1" = 100' scale on 11" x 17" size <br />sheets. However, there will also be areas or certain sections that may require a more focused <br />examination (i.e., at 1" = 40' scale) in order to resolve specific design issues. <br />151 Page <br />
The URL can be used to link to this page
Your browser does not support the video tag.