SCOPE OF SERVICES <br />• Electrical General Sheet (1) <br />• Electrical Stormwater Pump Station Site <br />Plan (1) <br />• Electrical Stormwater Pump Station Power <br />Plan (1) <br />• Electrical Stormwater Pump Station Control <br />Plan (1) <br />• Electrical Stormwater Pump Station <br />Lighting Plan (1) <br />• Electrical Stormwater Pump Station <br />Grounding Plan (1) <br />• Electrical Stormwater Tank Power and <br />Control Plan (1) <br />• Electrical Stormwater Control Building <br />Power Plan (1) <br />• Electrical Stormwater Control Building <br />Control Plan (1) <br />• Electrical Stormwater Control Building <br />Lighting Plan (1) <br />• Electrical Stormwater Control Vault Power <br />and Control Plan (1) <br />• Electrical Stormwater Control Vault Lighting <br />Plan (1) <br />• Electrical Single Line Diagram (1) <br />• Electrical Conduit Schedules (2) <br />• Electrical Pump Control Schematic (1) <br />• Electrical Details (3) <br />• P&IDs (3) <br />• Total sheets: 80 <br />Tetra Tech will rely on geotechnical design <br />parameters provided by Mark Thomas. <br />It is assumed the Pump Station and retention <br />improvements are within properties that will be <br />affected with the Project. Therefore, Tetra Tech will <br />prepare the needed plans for relocation or <br />demolitions and re-establishment (such as <br />irrigation, landscape, electrical services, lighting, <br />gas services, communication, etc.). <br />7.3.3 Storm Drain Plans <br />Mark Thomas will prepare construction drawings <br />for the Storm Drain Plan relocations for the 35%, <br />65%, 95%, 100%, and Final submittals. It is <br />assumed that the following is required.- <br />* Plan and Profile sheets (5, 20 scale) <br />Detail sheets (2) <br />Total Sheets: 7 <br />CITY OF SANTA ANA <br />SANTA ANA BOULEVARD GRADE SEPARATION <br />HARK THOHAS <br />7.4 Water Quality <br />7.4.1 WQMP <br />Tetra Tech will prepare a WQMP for the project as <br />required for urban runoff from municipal separate <br />storm systems (MS4 Permit). The scope of the <br />WQMP shall include recommendation for post <br />construction permanent best management <br />practices (BMP's), including source control <br />(structural and non-structural) and treatment <br />BMPs. <br />Scope assumes recommendations for BMPs shall <br />be incorporated into the projects PS&E for the <br />design tasks by Mark Thomas. Base project data <br />for SWPPP preparation (areas, slopes, etc.) will be <br />provided. <br />Scope assumes SWPPP will be provided by the <br />construction contractor per the RFP. <br />7.4.2 Water QualitylBMP Plans <br />Mark Thomas will prepare construction drawings <br />for the Water QualitylBMP Plans for the 35%, <br />65%, 95%, 100%, and Final submittals. The <br />Layout and details will be included in the Storm <br />Drain Plans and Details as part of task 7.3.3. <br />7.5 Planting & Irrigation <br />Mark Thomas will prepare Planting and Irrigation <br />plans for the 35%, 65%, 95%, 100%, and Final <br />submittals. a conceptual planting layout plan and a <br />plant palette for City review prior to proceeding <br />with the 65% submittal. The following submittal <br />milestones will incorporate updates based on the <br />City's comments on the conceptual planting layout <br />plan. The planting plans will include a complete <br />plant layout, plant callouts and notes, and quantity <br />sheets. Shrubs will be shown with hatch patterns <br />in the PS&E package. <br />The irrigation layout will be prepared and will <br />include irrigation head and valve locations, valve <br />callouts, and paint -of -connection callouts and <br />notes. Lateral line sizing and notation will be <br />included at the 95% submittal. The irrigation <br />system is assumed to be a new system connecting <br />to the existing water meters. <br />If as -built drawings with sufficient information are <br />not available, planting and irrigation removal and <br />repair areas will be identified with callouts only. <br />