My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
FULL PACKET_2011-02-22
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2011
>
02/22/2011
>
FULL PACKET_2011-02-22
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/26/2016 2:01:55 PM
Creation date
2/17/2011 1:18:00 PM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Date
2/22/2011
Destruction Year
2016
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
456
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ATTACHMENT 2 <br />footing at least 18" deep. <br />• All new block walls shall be constructed with 6X8X16 <br />concrete block. They shall be properly supported by a <br />continuous footing and reinforced with steel bar. <br />PORCHES, STEPS, BALCONIES & RAILING <br />Minimum Standard <br />. Safe and structurally sound. <br />Rehabilitation <br />• Porches, steps, balconies and railing that do not meet <br />the minimum standard shall be replaced. Practical, cost <br />effective repairs are acceptable as long as compliance with <br />the minimum standard will be achieved. <br />Concrete <br />• 2,000 PSI (minimum). <br />Finishes <br />• Zero or low VOC primers, paint and coatings. <br />FOUNDATIONS <br />Minimum Standard <br />• Safe and structurally sound. <br />Rehabilitation <br />• Foundations that do not meet the minimum standard <br />shall be replaced. Practical, cost effective repairs are <br />acceptable as long as compliance with the minimum <br />standard will be achieved. <br />• If the project involves a gut rehab, raised foundations <br />shall be completely insulated. <br />Concrete <br />• 2,000 PSI (minimum). <br />EXTERIOR WALLS <br />Minimum Standard <br />• Safe, structurally sound and weather-tight. <br />Rehabilitation <br />• Exterior walls that do not meet the minimum standard <br />shall be replaced. Practical, cost effective repairs are <br />acceptable as long as compliance with the minimum <br />standard will be achieved. <br />• Seal all joints. <br />• If the project involves a gut rehab, all exterior walls shall <br />be insulated. <br />EXTERIOR DOORS <br />Minimum Standard • Safe, sound, weather -tight and in good working order. <br />• Five or more years of practical utility. <br />Rehabilitation • Exterior doors that do not meet the minimum standard <br />NSP3 Substantial Amendment <br />City of Santa Ana <br />20A -57 <br />Page 3 <br />