My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
19F - RFP DEMO 710 714 AND 720 E 6TH ST
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2016
>
04/05/2016
>
19F - RFP DEMO 710 714 AND 720 E 6TH ST
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/31/2016 4:09:16 PM
Creation date
3/31/2016 2:22:21 PM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Agency
Community Development
Item #
19F
Date
4/5/2016
Destruction Year
2021
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
158
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
7.2 CONDITION <br />Once the friability of the material is determined, the material is assessed as to the condition <br />of its present state. The assessment of a material considers factors such as damage, potential <br />for disturbance, and estimated exposure potential. Suspect ACMs were assessed to be in <br />good, damaged, or significantly damaged condition based on how their condition at the time <br />of the survey related to the following: <br />Good Condition - <br />No or very limited visible damage or deterioration <br />was observed. <br />Damaged Condition - Crumbling, blistering, water damage, gouges, or <br />other damage was observed over less than 25% of <br />the materials (one -tenth if evenly distributed); or <br />accumulation of suspect powder, dust or debris <br />below the material was observed. <br />Signifwantly Damaged Condition - <br />Crumbling, blistering, water damage, gouges, or <br />other damage was observed over greater than 25% <br />of the material (one -tenth if evenly distributed); <br />material is delaminating or showing adhesive <br />failure; or accumulation of suspect powder, dust <br />or debris below the material was observed. <br />8. LABORATORY RESULTS <br />POSITIVE FOR ASBESTOS <br />Asbestos was present in quantities greater than one percent ( >1 %) in the following <br />building material samples: <br />DESCRIPTION <br />LOCATION <br />SAMPLES <br />ASBESTOS ' <br />FRIABLE <br />CONDITION, <br />SIZE <br />WFP -1 <br />None Detected <br />Good <br />CONTENT <br />Dining Room <br />WFP -2 <br />S /FT <br />Roof Vent <br />Roof <br />RPM -1 <br />3% <br />No <br />Good <br /><5 <br />Penetration <br />WSR -1 <br />None Detected <br />Chrysotile <br />Rock Walls <br />Bedroom 3 <br />WSR -2 <br />Mastic -Black <br />White <br />Kitchen 2 <br />WSR -3 <br />LTE assumed the roof transite pipe (cement flue) contains asbestos. <br />NEGATIVE FOR ASBESTOS <br />The following bulk samples tested negative for asbestos: <br />DESCRIPTION <br />LOCATION <br />SAMPLES <br />COLLECTED <br />ASBESTOS <br />CONTENT <br />CONDITION <br />Interior Plaster <br />Living Room <br />WFP -1 <br />None Detected <br />Good <br />Walls <br />Dining Room <br />WFP -2 <br />Light Brown <br />Living Room <br />WFP -3 <br />Interior Sheet <br />Kitchen 1 <br />WSR -1 <br />None Detected <br />Good <br />Rock Walls <br />Bedroom 3 <br />WSR -2 <br />White <br />Kitchen 2 <br />WSR -3 <br />19F -51 <br />
The URL can be used to link to this page
Your browser does not support the video tag.